Karnataka Wine Board
Munegowda
CONSTRUCTION OF ESSENTIAL BASIC INFRASTRUCTURE FOR EXISTING COLD STORAGE AT WINE PARK, THORVI VILLAGE, TIKOTA TALUK, VIJAYAPURA DISTRICT UNDER RIDF 31.
KWB/2026-27/BD/WORK_INDENT3
KWB/2026-27/BD/WORK_INDENT3
Open
Buildings
Two Tender Document System(Two Cover)
Karnataka Wine Board Head Office Bangalure
3 documents required · 2 mandatory · 1 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
Constitution or legal status of Tenderer
Work performed as Prime Contractor (in the same name) on works of similar (building/road) nature over during the five years specified in 1.2 above.
Quantities of work executed as prime contractor (in the same name) during the last five years specified in 1.2 above
Existing commitments and on-going works
Works for which Tenders already submitted
The following items of equipment are considered essential for successfully carrying out the works. The tenderer should furnish all the information listed below.
Name, address, and telephone, telex, and fax numbers of the Tenderers bankers who may provide references if contacted by the Employer
Evidence of access to financial resources to meet the qualification requirement specified in ITT Clause3.3 (b): Cash in hand, Letter of Credit etc. List them below and attach certificate from the Banker in the suggested format as under
SECTION 3: QUALIFICATION INFORMATION
SECTION 4: FORMS OF TENDER, LETTER OF ACEPTANCE, NOTICE TO PROCEED WITH THE WORK AND AGREEMENT FORM
all Technical documents should be uploaded as per tender document
To qualify for award of this contract, each Tenderer in its name should have in the last five years(2021-2022 to 2025-2026) 1.achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only)of Rs. 20.60 crores. 2.satisfactorily completed(at least 90% of the contract value), as prime contractor, at least one similar work comprising construction of buildings and/or infrastructure works including roads, drainage, sheds, compound wall and other allied civil works, of value not less than Rs. 8.24 Crore. 3.The Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works and should have executed similar electrical works totalling Rs. 38.00 lakh in any one year. 4.The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works and should have executed similar water supply/sanitary engineering works totalling Rs.60.00 lakh in any one year
liquid assets and /or availability of credit facilities of no less than Rs.257.50 Lakhs (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc.
Total value of civil engineering construction works executed and payments received in the last five years ((in Rs. Lakhs) (Attach certificate from charted Accountant)
Reports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five years
BANKERS CERTIFICATE
₹5,000
₹11.5 L
9 Sept 2026
9 Sept 2026
5 Oct 2026
22 Sept 2026
22 Sept 2026
Fabricating, supplying, and erection of .. hot-dip galvanized octagonal pole with BS EN 10025 grade S355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet, and MCBs as per IS specifications suitable to withstand the wind speed of 47 mors for ... m pole in single section and single joint welded as per IS 9595orIS 10178 AW, having dimensions bottom ... mm, top ... mm with 3 mm thick, suitable base plate and 4 nos of ... long J bolts along with template. The pole shall be hot-dip galvanized in single dipping with not less than 65 microns as per ASTM-A123 and 153, etc. (excluding foundation) as per drawing appended. 8 m - Top 70 mm and Bottom 135 mm dia
Fabricating, supplying, and erection of .. hot-dip galvanized octagonal pole with BS EN 10025 grade S355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet, and MCBs as per IS specifications suitable to withstand the wind speed of 47 mors for ... m pole in single section and single joint welded as per IS 9595orIS 10178 AW, having dimensions bottom ... mm, top ... mm with 3 mm thick, suitable base plate and 4 nos of ... long J bolts along with template. The pole shall be hot-dip galvanized in single dipping with not less than 65 microns as per ASTM-A123 and 153, etc. (excluding foundation) as per drawing appended10 m - Top 70 mm and Bottom 175 mm dia
Fabrication, Supplying, Erection, Testing and Commissioning of 16 m - Top 150 mm and Bottom 410 mm dia ms long Polygon high mast with SingleorMultiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JOorASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 mors as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062orASTM A572-50. The mast shall be Galvanized in single Hot- dip as per BSEN ISO 1461orASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7or19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manualorpower tool (Suitable reversible geared motor operating on 230or415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data.
Supplying and fixing of hot-dip galvanized M.S. bracket suitable for outdoor luminaires and mounted on octagonal pole using necessary bolts, nuts, etc., complete.Single Arm Bracket with 1000 mm Standard 40or50 mm dia
Supplying and fixing of hot-dip galvanized M.S. bracket suitable for outdoor luminaires and mounted on octagonal pole using necessary bolts, nuts, etc., complete Double Arm Bracket with 1000 mm Standard 40or50 mm dia
Supply of LED streetlight luminaire with pressure die-cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti-glare clear diffuser with injection-moulded polycarbonate material, delivering superior light output. Rated life burning hours: 50,000 hrs at Lumen Maintenance of 70percentage. Maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power factor greater than 0.9 with mains. Surge protection - Min 5 kV along with overvoltageoroverload, short circuitormiss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50 mm. Universal voltage driver to operate wide voltage range from 100V to 270V, 50or60 Hz application. Compliance to IS 10322orIEC 60598, LM79 and LM80. Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the site location with minimized minimal tools. LED light fixture with ........ W system power consumption. LED efficiency greater than 130 lmorw, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABLorCPRI and any government certified agency and design and development facility certified by ISO 9001:2008. Housing with supplier wordmarkorname shall be engravedorembossed on the die-cast housingorbody part. Warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaorLumiledsorOsram make LED source.LED Streetlight 70W
Supply of LED streetlight luminaire with pressure die-cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti-glare clear diffuser with injection-moulded polycarbonate material, delivering superior light output. Rated life burning hours: 50,000 hrs at Lumen Maintenance of 70percentage. Maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power factor greater than 0.9 with mains. Surge protection - Min 5 kV along with overvoltageoroverload, short circuitormiss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50 mm. Universal voltage driver to operate wide voltage range from 100V to 270V, 50or60 Hz application. Compliance to IS 10322orIEC 60598, LM79 and LM80. Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the site location with minimized minimal tools. LED light fixture with ........ W system power consumption. LED efficiency greater than 130 lmorw, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABLorCPRI and any government certified agency and design and development facility certified by ISO 9001:2008. Housing with supplier wordmarkorname shall be engravedorembossed on the die-cast housingorbody part. Warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaorLumiledsorOsram make LED sourceLED Streetlight 150 W
"Supply of LED pole mounting type post-top lantern with pressure die-cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti-glare clear diffuser with injection-moulded polycarbonateorclear glass material, delivering superior light output. Rated life burning hours: 50,000 hrs at Lumen Maintenance of 70percentage, CCT greater than 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power factor greater than 0.9 with mains. Surge protection - Min 5 kV along with overvoltageoroverload, short circuitormiss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50 mm. Universal voltage driver to operate wide voltage range from 100V to 270V, 50or60 Hz application. Compliance to IS 10322orIEC 60598, LM79 and LM80. Adherence with RoHS. UL approved MCPCB. LED efficiency greater than 130 lmorw, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABLorCPRI and any government certified agency and design and development facility certified by ISO 9001:2008. Housing with supplier wordmarkorname shall be engravedorembossed on the die-cast housingorbody part. Warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaorLumiledsorOsram make LED source. LED Post Top Lantern with 25or30 W
LED Flood Light: Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonateorclear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, CCT greater than 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltageor Overload, short circuitor miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50or60Hz application. Compliance to IS 10322or IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than 1301morw, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL or CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark or name shall be Engraved or Embossing on the die cast housing or Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaor LumiledsorOsram make LED Source .LED Floodlight 70W
LED Flood Light: Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonateorclear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, CCT greater than 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltageor Overload, short circuitor miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50or60Hz application. Compliance to IS 10322or IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than 1301morw, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL or CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark or name shall be Engraved or Embossing on the die cast housing or Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaor LumiledsorOsram make LED Source LED Floodlight 100W
Supply of LED bollard light fitting of ... W with pressure die-cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti-glare clear diffuser with injection-moulded polycarbonateorclear glass material, delivering superior light output. Rated life burning hours: 50,000 hrs at Lumen Maintenance of 70percentage, CCT greater than 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power factor greater than 0.9 with mains. Surge protection - Min 5 kV along with overvoltageoroverload, short circuitormiss-wiring protection. Universal voltage driver to operate wide voltage range from 100V to 270V, 50or60 Hz application. Compliance to IS 10322orIEC 60598, LM79 and LM80. Adherence with RoHS. UL approved MCPCB, with 2 years warranty against any manufacturing defect working under standard electrical conditions. 8W 1 m Height
ELECTRICALS:Open Conduit System :- Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wallor stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19or20 mm dia 2 mm thick.
ELECTRICALS:Open Conduit System :- Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wallor stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick
ELECTRICALS:Open Conduit System :- Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wallor stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 32 mm dia 2.5 mm thick
ELECTRICALS:Open Conduit System :- Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wallor stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 40 mm dia 2.5 mm thick
Concealed Conduit System:- Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25 mm dia 2 mm thick
Concealed Conduit System:- Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessar 32 mm dia 2.5 mm thick
Concealed Conduit System:- Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessar40 mm dia 2.5 mm thick
Supplying and fixing PVCormetal conduit Deep junction box 25 mm deep Junction box
Supplying and fixing PVCormetal conduit Deep junction box 32 mm deep Junction box
Extra for Groove cutting in brick wallorCC floor to the suitable depth for concealing of ConduitorGI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit in brick wall
Extra for Groove cutting in brick wallorCC floor to the suitable depth for concealing of ConduitorGI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit CC Floor
Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5mSqm (Phase and Neutral) and 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet Short point upto 3m from tapping point to out let via switch box
Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5mSqm (Phase and Neutral) and 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet Medium point above 3m upto 6m from tapping point to out let via switch box
Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5mSqm (Phase and Neutral) and 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet Long point above 6m upto 10m from tapping point to out let via switch box
Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1 mSqm
Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mSqm
Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mSqm
Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mSqm
Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 Sqm (metering panel to TPN DB )
Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 10 Sqm
Supplying and fixing surfaceorflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickorC.C wall, including necessary rawl plugs, MachineorNF screws etc., complete- 3 Way
Supplying and fixing surfaceorflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickorC.C wall, including necessary rawl plugs, MachineorNF screws etc., complete- 6 Way
Supplying and fixing surfaceorflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickorC.C wall, including necessary rawl plugs, MachineorNF screws etc., complete- 8 Way
Supplying and fixing surfaceorflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickorC.C wall, including necessary rawl plugs, MachineorNF screws etc., complete 10-12 Way
Supplying and fixing surfaceorflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickorC.C wall, including necessary rawl plugs, MachineorNF screws etc., complete 16-18 Way
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box 10-12 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box 16-18 Module
Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way Switch
Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Two Way Switch
Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A socket
Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One Way Switch
Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A Bell Push
Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6or16A Universal Socket
Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 mors for .......m Pole in single section and single joint welded as per IS 9595orIS10178AWS having dimensions bottom ..... mm , top.... mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended 8 m - Top 70 mm and Bottom 135 mm dia-7 mtr pole
Supplying, and fixing of Hot dip Galvanized M.S.Bracketsuitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete Single Arm Bracket with 1500 mm Standard 40or50 mm dia
Supplying, and fixing of Hot dip Galvanized M.S.Bracketsuitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete Double Arm Bracket with 1500 mm Standard 40or50 mm dia
Supplying and fixing retrofit type-PL- LED Lamp ...... W LED linear source with CCT 6500 degree K, CRIgreater than 70percentage. efficacy greater than80 lumen per W, lifegreater than 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5percentage of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20percentage, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. -9 watts
Supplying of .....feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percentage lumen maintenance with CRI greater than 80. Power Input: 220-240Vat 50or60Hz and Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED LIGHT FITTING, 1X2' -9or10W.
Supply of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater than 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire Greater than IK08. Power Factor Greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltageor Overload, short circuitor miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50or60Hz application. Compliance to IS 10322orIEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency Greater than 1301morw, nominal CRI Greater than75. Luminaire manufacturer should have in-house facility accredited by NABLorCPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark orname shall be Engraved or Embossing on the die cast housingor Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 70W
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltageor Overload, short circuitor miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50or60Hz application. Compliance to IS 10322orIEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than1301morw, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABLorCPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark orname shall be Engraved or Embossing on the die cast housingor Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaor LumiledsorOsram make LED Source.- - LED 40 watts
Supplying and fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI Greater than 70percentage. efficacy Greater than 80 lumen per W, life Greater than 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater than 0.95, power loss should less than 5percentage of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 18W-20W (T8)
Fixing all types and all capacities of fluorescent orfalse ceiling or spot light or CFL or -12watts LED fittings indoor on the wallor ceiling or rafters or girders using 23or0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA On wallor ceiling or Rafter or Girders
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374or79 and also comply with IS: 1709or1984 with latest amendment, Rated voltage 220 Vor50 Hz, Rated power input 48 W +or- 10 percentage, Rated current As per IS:374or79, Rated power factor 0.9 lagging(min), Rated speed 350 +or- 10percentage RPM, Rated air delivery 210 +or- 10percentage Cubic Mtr Minimum, Rated service value 4.2 CMM or W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, Wand current, Air Delivery and Fan Speed as per IS:374or1979 with latest amendment, 2 year manufacturer Warranty 48" Sweep 5 Star (1200 mm)
Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23or0.0076 inch PVC insulated twin core wire.
Supply, Transportation unloading, installation, testing and commissioning of Metering Panel comprising of the followings and including all other accessories etc., Incomer : 1 No 160A TPN MCCB with three phase indication lamp and Outgoing : 7 No 63A 4P MCB and 7 nos 60Amps Digital Energy Meter -Kwhr meter Bus bars: 160A TPN Aluminium Busbars 25KA per 1 Sec. All the neutral busbars shall have 100percentage capacity of phase busbars Wall mounting type fabricated with 16 SWG CRCA sheet enclouser, Door and partition 18 SWG CRCA sheet. The Panel shall be complete with iterconnections and two earthing etc., All door should have proper lockingor sealing arrnements. For flats power supply panel .
Supply, Transportation unloading, installation, testing and commissioning of Metering Panel comprising of the followings and including all other accessories etc., Incomer : 1 No 63Amps MCCB with indication lamp and Outgoing : 3 No 40A DP MCB with 40Amps Digital Energy meter (Kwhr meter) and Bus bars: 80A TPN Aluminium Busbars 25KA per 1 Sec. All the neutral busbars shall have 100percentage capacity of phase busbars Wall mounting type fabricated with 16 SWG CRCA sheet enclouser, Door and partition 18 SWG CRCA sheet. The Panel shall be complete with iterconnections and earthing etc., All door should have proper lockingor sealing arrnements. For Shop power supply panel
Supplying and fixing regular MCB distribution boards on wallorood board or flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phaseor3 phaseorsingle door with powder coated painting Made out of 14 SWG MS enclosure.4 Way TP and N
Supplying and fixing regular MCB distribution boards on wallorood board or flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phaseor3 phaseorsingle door with powder coated painting Made out of 14 SWG MS enclosure8 Way SP and N
Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240or450V upto 300mA sensitivity on existing woodor panel board.32-40A 4 pole
Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240or450V upto 300mA sensitivity on existing woodor panel board.32-40A 2 pole
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP
Supplying fixing and wiring earth electrode for grounding of metering Panel, shop panel, etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.
Supply, Installation, testing and commissioning of Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc.but with charcoal or coke and salt as required. (Electrical DSR: Item No:5.4)
Supply , Installation, testing and commissioning of 4.00 mm dia copper wire on surface or in recess for loop earthing as required (Electrical SOR: Item No:5.17)
Supply , laying , termination and commissioning of following XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I).or1554-I , Makes: Torent or Universal or Unicab or Havells or KEI or Gloster or Polycab orRR Kabel 31or2 x 95 Sqmm (Cable from power control room to flat metering panel -Approximate quantity) Cost including required end termination material.
Supply , Installation, testing and commissioning of following XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I).or1554-I Makes: Torent or Universal or Unicab or Havells or KEI or Gloster or Polycab orRR Kabel 4 x 16 Sqmm ( Cable from Metering room to Flat TPN DB and Street light work) Cost including required end termination material.
Supply and transportation of following XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I).or1554-I Makes: Torent or Universal or Unicab or Havells or KEI or Gloster or Polycab orRR Kabel 2 x 10 Sqmm
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 kV grade as required - 2 X 10 sq.mm (19mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X16 sq.mm (28 mm)
Supplying, installing, testing and commissioning of 320 kVAor256 kW Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514orISO 3046or ISO 8528 and IS 1002orISO 3046 Generator set specification
Supply, Erection, testing and commissioning of AMF panel suitable for 250kVA DG set. The panel is of cubical type baseorfloor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal OorL relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine startorstop logic, Mainsorgenerator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperatureorLube oil pressureor engine speed, VoltageorampereorFrequencyor kVA, Running-hour count, No of starts, Fault indication, over or under speed, Fails to start, Low oil pleasure, High engine temperature, Underorover voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt AutoorManual and FlatorBoost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rule
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction
Plant Mix Method: Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401- For Grading -II Material
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kgor m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing
Construction of M40 Grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base in recommended proportions, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a slip form paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing OPC at 420 kgorm3
Providing and fixing in position 12 mm thick bitumen impregnated fiber board conforming to IS:1838, including cost of primer, sealing compound Grade-A in expansion joints.
Laying Reinforced cement concrete pipe NP4orprestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.1000 mm dia
Laying Reinforced cement concrete pipe NP4orprestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets 1200 mm dia
Laying Reinforced cement concrete pipe NP4orprestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets .1500 mm dia
Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401- For Grading -II Material
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kgor m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and including Centering and shuttering)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 and IS 15658 for Cycle Tracks and Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMMorWBM Base to be paid separately if necessary as per relevant technical specification)
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction
Plant Mix Method: Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401- For Grading -II Material
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kgor m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing
Construction of M40 Grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base in recommended proportions, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a slip form paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing OPC at 420 kgorm3
Providing and fixing in position 12 mm thick bitumen impregnated fiber board conforming to IS:1838, including cost of primer, sealing compound Grade-A in expansion joints.
Laying Reinforced cement concrete pipe NP4orprestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.1000 mm dia
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and including Centering and shuttering) .Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Bottom Raft
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Wall
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesTop Slab
Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
Providing and laying 100mm thick pre-cast cover slabs over Road side drains or utility ducts or Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 at 6kgor m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.
Providing and fixing Steel work welded in built up sectionsor framedwork, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer using structural steel etc. as required. Ingratings, frames, guard bar, ladder, railings, brackets, gates and similarworks including cost of materials, labour, usage charges of machinerycomplete as per specifications and as per directions of the Engineer-inCharge.
Providing and constructing dry rubble stone pitching with pin headers at 2 per m2 using stones and stone chips from approved source including cost of all materials, labour, hand packing or wedging stonechips, finishing and all other ancillary operations complete 250 thk
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling available approved GravelorMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work.
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. or Lindane 20percentage E.C. at 3.19 lorm2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
Providing and Filling in foundation with granite or trap broken metal 100mm. And down size and with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footing
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesColumnorPedastrals
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPlinth Beam
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Column
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground FloorRoof Beam and Lintel
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground FloorRoof Slab
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates First floor Columns
Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brickorstone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer- in-charge.
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Finishing walls with 100percentage Premium acrylic emulsion paint having VOC less than 50 gmorlitre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied at 1.43 litreor 10 m². Over and including priming coat of exterior primer applied at 0.90 litreor10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percentage and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kgor m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring, Staircase Tread and Riser in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
Providing and fixing ball bearing for rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge.
Extra for providing mechanical device chain and crank operation for operating rolling shutters: including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge.
Extra for providing Manually operated Bevel Gear Box for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings or wooden frames with rawl plugs screws etc.
Providing and fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made)
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised ironor steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge
Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percentage integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
Supplying and Providung Pre moulded Joint filler, 25 mm thick for expansion joint including all cost 0f materials and labours etc..
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling available approved GravelorMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work.
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. or Lindane 20percentage E.C. at 3.19 lorm2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
Providing and Filling in foundation with granite or trap broken metal 100mm. And down size and with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and including Centering and shuttering)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and including Centering and shuttering)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footing
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Columnor Pedastrals
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth Beam
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Column
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Roof Beam and Lintel
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Roof Slab and Staircase
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Sunshade
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering))M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates First Floor Column
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates First Floor Roof Beam and Lintel
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates First Floor Roof Slab and Staircase
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates First Floor Sunshade
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering))M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Second Floor Column
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering))M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesSecond Floor Roof Beam and Lintel
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Second Floor Roof Slab and Staircase
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Second Floor Sunshade
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering))M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Third Floor Column
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Third Floor Roof Beam and Lintel
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Third Floor Roof Slab and Staircase
Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work
Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge
Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brickorstone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof including cost of material, labour, scaffolding etc as per specifications and as per directions of the Engineer-in-Charge.
Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment
Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Finishing walls with 100percentage Premium acrylic emulsion paint having VOC less than 50 gmorlitre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied at 1.43 litreor 10 m². Over and including priming coat of exterior primer applied at 0.90 litreor10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08percentage and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling or grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring, Staircase Tread and Riser in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceorChajjasorSunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percentage and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.
Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percentage integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.
Providing Honne wood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
Providing and fixing cramps of required size and shape in RCCor CC or Brick masonry backing with cement mortar 1:2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps
Providing and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)
Providing and fixing flush door shutter made out of solid core block board type, well seasoned, chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick both side commercial
Providing and fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom
Providing and fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for forming hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS 14856 Including fixing to frames
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.
Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete
Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm
Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 100 mm with plate 150x32 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x70x4 mm (ordinary type)
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100x70x4 mm (ordinary type)
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing chromium plated brass curtain rod with ISI mark having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete 20mm dia
Providing and fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made)
Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL- 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size – 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings or wooden frames with rawl plugs screws etc.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, iorc fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
Providing and fixing double action hydraulic floor spring of approved brand manufacture conforming to IS : 6315, having brand logo embossed on the body or plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge: With stainless steel cover plate minimum 1.25 mm thickness including cost of materials, labour, usage charges of machinery complete as per specifications.
Providing and fixing Steel work welded in built up sectionsor framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied at 0.90 ltror10 m² over an under coat of primer applied at0.75 ltror10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised ironor steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Supplying and fixing SFRC frame and cover conforming to IS 12592 (partI)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete. Heavy Duty
Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for ductorshaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powderorrice huskorwheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kgorm3 and screw withdrawal strength of 1800 N (Face)minimumcompressive strength 50 Normm2 , modulus of elasticity 850 Normm2 and resistance to spread of flame of Class A category with properties of being termiteorborer proof, waterormoisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately).
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 32 mm nominal bore - Vertical
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore - Vertical
Providing and fixing toilet paper holder : C.P. brass Paper Holder Make -TOTO or Kohler or Jaguar
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mmhigh and 112 mm distance from wall of standard shape with bracket ofthe same materials with snap fittings of approved quality and colour,weighing not less than 105 g
Providing and fixing Stainless Steel A ISI 304 (18or8) kitchen sink as perIS:13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the wallswherever required : 510x1040 mm bowl depth 225 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe - 40 mm dia
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality and make as approved by Engineer in charge.
450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g.
Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 600X850 mm internaldimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slabwith 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finishedsmooth with a floating coat of neat cement on walls and bed concrete etc.
Providing and fixing square-mouth S.W. gully trap class SP-1 completewith C.I. grating brick masonry chamber with water tight C.I. cover 180x 150 mm size P type and With Non Modular common burnt clay bricksof designation 3.5 and frame of 300 x300 mm size (inside) the weight ofcover to be not less than 4.50 kg and frame to be not less than 2.70 kg asper standard design:
Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, forcold water supply including all uPVC plain and brass threaded fittingsThis includes jointing of pipes and fittings with one step uPVC solventcement, trenching, refilling and testing of joints complete as per directionof Engineer in Charge. External work.150 mm nominal dia Pipes
Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, forcold water supply including all uPVC plain and brass threaded fittingsThis includes jointing of pipes and fittings with one step uPVC solventcement, trenching, refilling and testing of joints complete as per directionof Engineer in Charge. External work .100 mm nominal dia Pipes
Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, forcold water supply including all uPVC plain and brass threaded fittingsThis includes jointing of pipes and fittings with one step uPVC solventcement, trenching, refilling and testing of joints complete as per directionof Engineer in Charge. External work . 80 mm nominal dia Pipes
Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, forcold water supply including all uPVC plain and brass threaded fittingsThis includes jointing of pipes and fittings with one step uPVC solventcement, trenching, refilling and testing of joints complete as per directionof Engineer in Charge. External work.40 mm nominal dia Pipes
Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0cm X 4.0 cm with all fitting arrangements and all necessary accessoriescomplete
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : * 100 mm inlet and 100 mm outlet * Sand cast iron SandS as per IS: 3989
Supply and Fixing Chlorinated Polyvinyl Chloride pipes (CPVC) of SDR 11 and fittings as per ASTM D 2846 and specials such as tees, elbows, couplers etc with CPVC brass threaded combinationortransition specials such as male adopters brass threaded, female adopters brass threaded, brass MABTorFABT tee, brass MABTorFABT elbow etc where connection with metal is to be made including cutting holes and chases in walls and floors and refilling it by cement mortar of 1:3 mix (1 Portland Cement : 3 hard settling cement compound) and making good the walls etc as directed by the Engineer in charge. Joints to be made with CPVC solvent as per ASTM F 493 with necessary fittings etc., complete.20 mm nominal dia pipes
Supply and Fixing Chlorinated Polyvinyl Chloride pipes (CPVC) of SDR 11 and fittings as per ASTM D 2846 and specials such as tees, elbows, couplers etc with CPVC brass threaded combinationortransition specials such as male adopters brass threaded, female adopters brass threaded, brass MABTorFABT tee, brass MABTorFABT elbow etc where connection with metal is to be made including cutting holes and chases in walls and floors and refilling it by cement mortar of 1:3 mix (1 Portland Cement : 3 hard settling cement compound) and making good the walls etc as directed by the Engineer in charge. Joints to be made with CPVC solvent as per ASTM F 493 with necessary fittings etc., complete.25 mm nominal dia pipes
Supply and Fixing Chlorinated Polyvinyl Chloride pipes (CPVC) of SDR 11 and fittings as per ASTM D 2846 and specials such as tees, elbows, couplers etc with CPVC brass threaded combinationortransition specials such as male adopters brass threaded, female adopters brass threaded, brass MABTorFABT tee, brass MABTorFABT elbow etc where connection with metal is to be made including cutting holes and chases in walls and floors and refilling it by cement mortar of 1:3 mix (1 Portland Cement : 3 hard settling cement compound) and making good the walls etc as directed by the Engineer in charge. Joints to be made with CPVC solvent as per ASTM F 493 with necessary fittings etc., complete.32 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including all CPVCplain and brass threaded fittings, including fixing the pipe with clamps at1.00 m spacing. This includes jointing of pipes and fittings with one stepCPVC solvent cement and testing of joints complete as per direction ofEngineer in Charge.Internal work - Exposed on wall 50 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply including all CPVCplain and brass threaded fittings This includes jointing of pipes and fittingswith one step CPVC solvent cement, trenching, refilling and testing of jointscomplete as per direction of Engineer in Charge. External work.65 mm nominal outer dia .pipes
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore
Supplying, installing , testing and commissioning of PN16 CI butterfly valvesof confirming to IS 13039 with necessary nuts and bolts etc., complete ---- etc.,complete as per specificaiton with all lead and lift, loading unloading, labour,hire charges of machineries and all such incidental charges necessary forsuccessful completion of work and as per directions of the Engineer-incharge of the work .65 mm
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling available approved GravelorMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work.
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. or Lindane 20percentage E.C. at 3.19 lorm2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
Providing and Filling in foundation with granite or trap broken metal 100mm. And down size and with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteor trapor basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and including Centering and shuttering) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates.
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footing
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Columnor Pedastrals
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth Beam
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Column
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Roof Beam and Lintel
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Roof Slab and Staircase
Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work
Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge
Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brickorstone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Finishing walls with 100percentage Premium acrylic emulsion paint having VOC less than 50 gmorlitre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied at 1.43 litreor 10 m². Over and including priming coat of exterior primer applied at 0.90 litreor10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
Providing and fixing Ceramic Cool tiles of size 254x254x15mm thickness thermal insulation properties as per GRIHA guidelines with satisfactory SRI greater than 70percentage and R value laid on 12mm insulated Mortar mix using heat proof sand complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percentage integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
Providingand fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2Dor3D hinge and Multi point locking system with Handle. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size – 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor TandP'
Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
Providing and fixing cramps of required size and shape in RCCor CC or Brick masonry backing with cement mortar 1:2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps
Providing and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)
Providing and fixing flush door shutter made out of solid core block board type, well seasoned, chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick both side commercial
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.
Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)
Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL- 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size – 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, iorc fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied at 0.90 ltror10 m² over an under coat of primer applied at0.75 ltror10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 32 mm nominal bore - Vertical
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore - Vertical
Supplying of special moulded variety PVC couplers as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark and with its latest amendments to walk site etc. complete. PVC couplers25mm dia PVC couplers
Supplying of special moulded variety PVC couplers as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark and with its latest amendments to walk site etc. complete. PVC couplers32mm dia PVC couplers
Supplying of special moulded variety PVC couplers as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark and with its latest amendments to walk site etc. complete. PVC couplers50mm dia PVC couplers
Supplying of special moulded variety PVC couplers as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark and with its latest amendments to walk site etc. complete. PVC couplers75mm dia PVC couplers
Supplying of special moulded variety PVC couplers as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark and with its latest amendments to walk site etc. complete. PVC couplers90mm dia PVC couplers
Supplying of special moulded variety PVC couplers as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark and with its latest amendments to walk site etc. complete. PVC couplers110mm dia PVC couplers
Supplying of special moulded variety PVC couplers as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark and with its latest amendments to walk site etc. complete. PVC couplers160mm dia PVC couplers
Supply and delivery at site special moulded variety PVC elbows as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Elbows25mm dia PVC Elbows
Supply and delivery at site special moulded variety PVC elbows as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Elbows32mm dia PVC Elbows
Supply and delivery at site special moulded variety PVC elbows as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Elbows50mm dia PVC Elbows
Supply and delivery at site special moulded variety PVC elbows as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Elbows75mm dia PVC Elbows
Supply and delivery at site special moulded variety PVC elbows as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Elbows90mm dia PVC Elbows
Supply and delivery at site special moulded variety PVC elbows as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Elbows110mm dia PVC Elbows
Supply and delivery at site special moulded variety PVC elbows as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Elbows160mm dia PVC Elbows
Supply and delivery at site special moulded variety PVC bend as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Bend25mm dia PVC Bend
Supply and delivery at site special moulded variety PVC bend as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Bend32mm dia PVC Bend
Supply and delivery at site special moulded variety PVC bend as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Bend50mm dia PVC Bend
Supply and delivery at site special moulded variety PVC bend as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Bend75mm dia PVC Bend
Supply and delivery at site special moulded variety PVC bend as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Bend90mm dia PVC Bend
Supply and delivery at site special moulded variety PVC bend as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Bend110mm dia PVC Bend
Supply and delivery at site special moulded variety PVC bend as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments PVC Bend160mm dia PVC Bend
Supply and delivery at site special moulded variety PVC tee as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 25mm dia PVC Tee
Supply and delivery at site special moulded variety PVC tee as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 32mm dia PVC Tee
Supply and delivery at site special moulded variety PVC tee as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 50mm dia PVC Tee
Supply and delivery at site special moulded variety PVC tee as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 75mm dia PVC Tee
Supply and delivery at site special moulded variety PVC tee as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 90mm dia PVC Tee
Supply and delivery at site special moulded variety PVC tee as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 110mm dia PVC Tee
Supply and delivery at site special moulded variety PVC tee as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 160mm dia PVC Tee
Supply and delivery at site special moulded variety PVC reducer as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 25 mm dia PVC Reducer
Supply and delivery at site special moulded variety PVC reducer as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 32 mm dia PVC Reducer
Supply and delivery at site special moulded variety PVC reducer as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 40 mm dia PVC Reducer
Supply and delivery at site special moulded variety PVC reducer as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 50 mm dia PVC Reducer
Supply and delivery at site special moulded variety PVC reducer as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 63 mm dia PVC Reducer
Supply and delivery at site special moulded variety PVC reducer as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 75 mm dia PVC Reducer
Supply and delivery at site special moulded variety PVC reducer as per IS 7834or 1987 and fabricated as per IG124or 1984 with ISI mark with its latest amendments 90 mm dia PVC Reducer
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe - 40 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc15 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc20 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc32 mm nominal dia pipes
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g.
Providing and fixing 100 mm sand cast Iron grating for gully trap.
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : * 100 mm inlet and 100 mm outlet * Sand cast iron SandS as per IS: 3989
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 100mm x 100mm size P type with Non Modular common burnt clay bricks of designation 3.5and water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay (non modular) bricks of class designation 3.5
Making soak pit 2.5 m diameter 3.0 m deep with 45 x 45 cm dry brick honey comb shaft with bricks and PVC S.W.R drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay (non modular) bricks of class designation 3.5
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. or Lindane 20percentage E.C. at 3.19 lorm2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
Filling available approved GravelorMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling,water,all materials,usageand all other appurtenaces required to complete the work.
Providing and Filling in foundation with granite or trap broken metal 100mm. And down size and with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footing
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesColumnorPedastrals
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPlinth Beam
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Column
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground FloorRoof Beam and Lintel
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground FloorRoof Slab
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground FloorRoof Sunshade
Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brickorstone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer- in-charge.
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Finishing walls with 100percentage Premium acrylic emulsion paint having VOC less than 50 gmorlitre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied at 1.43 litreor 10 m². Over and including priming coat of exterior primer applied at 0.90 litreor10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percentage and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kgor m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring, Staircase Tread and Riser in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.
Providing and fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made)
Providingand fixing of Openable window made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 75mm and GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 5mm plain float glass, Standard hardware with friction hinge and Multi point locking system with Handle. Wall thickness of frame and sash shall be of 2mm-2.5mm.Maximum possible size – 900mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made)
Providing and fixing flush door shutter made out of solid core block board type, well seasoned, chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick both side commercial
Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.
Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete
Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :125x70x4 mm (ordinary type)
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings or wooden frames with rawl plugs screws etc.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied at 0.90 ltror10 m² over an under coat of primer applied at0.75 ltror10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percentage integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and Filling in foundation with granite or trap broken metal 100mm. And down size and with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and including Centering and shuttering)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footing
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ColumnorPedastrals
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering)M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth Beam
Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering))M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Column
Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
Stone tile (polished) of 8mm thickness granite stone of any color and shade work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry at 3.3 kgorm2 including pointing in white cement complete.
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings or wooden frames with rawl plugs screws etc.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied at 0.90 ltror10 m² over an under coat of primer applied at 0.80 ltror10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Fencing with G.I. barbed wire R.C.C. post or Angle iron post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used.
Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and Filling in foundation with granite or trap broken metal 100mm. And down size and with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and including Centering and shuttering) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Wall
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteor traporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and including Centering and shuttering) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Slab
Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
Supplying and fixing SFRC frame and cover conforming to IS 12592 (partI)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete. Heavy Duty
Providing and Applying Crystalline waterproofing slurry coat RCC structure like Retaining wall, Underground tank. The material having chemical resistance properties, seals shrinkage cracks up to 0.4 mm width, capable of preventing water dampness and seepages, Water permeability is Nil confirms to BS EN 12390 Part 8: 2000. Powder to water mixed at a ratio (5:2) 5 parts powder and 2 parts water, applied at 1.5kgorm2 in 2 coats to achieve 1.0mm DFT on a cleaned surface free from all loose materials etc., complete. The finished cost to include surface preparation completely as per specification.
Ladder inside the container: Providing anodized aluminium ladder using 65mm x 32mm x 3.0mm ‘C’ section for ladder side channel x 25mm dia., flutal pipe for Rungs at 250mm corc ladder fixed at an angle of 70 degrees to horizontal including necessary 25mm dia., G.I. shutters with necessary G.I. fasteners for bracing the ladders to the Tank walls to prevent buckling of the ladder with necessary (M-15) bed for embedding the ladder bottom complete. aluminium ladder
Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl and Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of Work. for 3HP etc. Complete. 6.50 HP - 120 LPM at 112 m = 14 STG Outlet Dia - 2.00"
Excavation in foundations, trenches etc. in earth work in all kinds of soils such as pick work, jumper work, blasting work and chiselling or wedging out of hard or soft rock upto all heights stacking the excavated soil not more than 3 meteres clear from the edge of excavation and than returning the stacked soil in 15 cms layers, when required into plinths, sides of foundations etc.consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth in all leads and lifts. Earth work in all kinds of soils
Excavation in foundations, trenches etc. in earth work in all kinds of soils such as pick work, jumper work, blasting work and chiselling or wedging out of hard or soft rock upto all heights stacking the excavated soil not more than 3 meteres clear from the edge of excavation and than returning the stacked soil in 15 cms layers, when required into plinths, sides of foundations etc.consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth in all leads and lifts .Ordinary rock
Extra for every additional lift of 1.50 metre or part thereof for:
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Disposal of moorumorbuilding rubbishor malbaor similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movementor plying of load carrying motor vehicle of 3.5 cum or more
Supplying of high-quality perforated plastic crates with handles with dimensions of 600mm x 400mm x 325mm. Having capacity of approximately 20kg and are made from HDPEorPP material with additives for enhanced durability. Shall be available in vibrant redor blue colorsorany other color as requested by the client. Lightweight with a weight of just 1.7kg and easy to handle made from virgin food-grade material, ensuring the highest quality and safety standards. Grade-A crates are perfect for food and logistics. The rate are at site price i.e: including the packing, tranportation, loading and unloading, charges towards quality testing and other misc charges for clearance and supply of material
Supplying and installing heavy-Duty wooden duckboards manufactured from seasoned hardwood (Mikasa or equivalent approved make) for cold storage chamber flooring, comprising modular panels of size 1000 mm × 1000 mm (or manufacturer's standard size) with an overall thickness of 70–75 mm, consisting of 75 mm × 25 mm top slats fixed over 75 mm × 50 mm bottom runners, maintaining a clear spacing of 20–25 mm between slats and maximum 300 mm corc spacing between bottom runners, complete with SS304 fasteners, all necessary accessories, cutting, fitting, and fixing in position, suitable for pedestrian movement and hand pallet truck operation in cold storage applications. The rate shall include all materials, labour, packing, transportation, loading, unloading, installation, and all incidental charges required for complete execution at site
Design, engineering, manufacture, supply, transportation, unloading, erection, installation, testing and commissioning of Continuous Vertical Chain Conveyor Lift of circulatingorpaternoster type, having a minimum capacity of 2 TPH and minimum load capacity of 25 kg per carrier, for vertical transportation of carton boxes between designated floor levels, complete with heavy-duty continuous chain, carriersorplatforms, guide rails, sprockets, shafts, bearings, chain tensioning arrangement, drive motor, reduction gearbox, VFD, brakeoranti-runback arrangement, structural steel supporting frame, loadingorunloading arrangements, electrical control panel, PLCorcontrol system, sensors, limit switches, emergency stop devices, safety guards, interlocks, cabling, earthing and all necessary mechanical, structural, electrical, control, safety and ancillary components, including all labour, tools, tackles, lifting arrangements, alignment, testing, performance testing and commissioning, complete in all respects as per the Technical Specification, approved drawings and directions of the Engineer-in-ChargeorConsultant.
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. Cement morter 1:6 (1 cement : 6 coarse sand)
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal and 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations at 100 to 125 mm corc, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, iorc disinfection of tubewell, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-charge.
Supplying, filling, spreading andleveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge.
Supplying, filling, spreading andleveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer in-charge.
Supplying, filling, spreading and leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 41O plain slotted (having slot of size 1.613.2 mm) mild steel threaded and socketedor plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of antlcorroslve bltumastlc paint of approved brand and manufacture, lncluding usage and labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer -in-charge.100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 41O plain slotted (having slot of size 1.613.2 mm) mild steel threaded and socketedor plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of antlcorroslve bltumastlc paint of approved brand and manufacture, lncluding usage and labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer -in-charge.150 mm nominal size dia
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housingor casing pipe, removable as per requirement, all complete for borewell of:150 mm dia
Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fineor mediumor coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer in-charge.
Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl and Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of Work. for 3HP etc. Complete. 3.00 HP - 90 LPM at 66 m = 10 STG Outlet Dia - 2.00"
Supply of the following IP Based Closed Circuit Television System (IP CCTV) as per Tender Specificaitons , Installation, Commissioning, Testing and providing Reports, Certifications and Handover as per authority requirements including necessary authority inspections as requried.4MP at 25or30fpsat1440P (2560x1440) Dome Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens along with all mounting accessories
Supply of the following IP Based Closed Circuit Television System (IP CCTV) as per Tender Specificaitons , Installation, Commissioning, Testing and providing Reports, Certifications and Handover as per authority requirements including necessary authority inspections as requried.Mounting brackets for cameras including junction box and accessories as per OEM mounting requirements for Mounting Bullet Cameras in the process areas
Rack Mount Network Video Recorder upto 64 Channels with storage for 30 days for normal cameras recording at 30 FPS, 1080P (HD) resolution, 24 Hrs a day ( consider with 80percentage scene activity)., H.265 compression, including all rack mount accessories, ONVIF S and G Profile for third party camera interface. Embedded VMS Software for Video Management and Video recoding for all cameras plus 20percentage spare capacity. 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1or4or8or9or16or25or36or64, 2nd screen: 1or4or8or9or16
Serveillance grade Hard Disk with upto 256MBors Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003orNNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. . Number of Hard disc drive shall be proposed by the vendor considering 30 days of recording at 4 MP resolution, 24 frames per second, high scene activity. 10TB
Fully Mechanical Keyboard and Optical Mouse ( Dell or HPor Lenovo) to connect to NVR for CCTV monitoring and Control
LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity. Size 32 inch.
24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min.
Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required. 1G SFP Module, Single Mode Duplex, LC Type
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETLorUL verification program certificate for compliance with ANSIorTIA-568.2-D etc. complete as required.
Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETLorUL verification program certificate for compliance with ANSIorTIA-568.2-D etc. complete as required. Copper Patch Cords of length 1m (3ft)
Supply and fixing following port loaded LIU 6 Port with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single or Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. ( to be placed in camera Junction Box for other building cameras)
Supply and fixing following port Rack Mount loaded LIU 12 Port with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single or Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required.
Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset less than 50 µm, Fiber Height + 100 nm, End-face radius of Curvature 7mm less than R less than25mm, Repeatability less than 0.2 db, Working ambient Temperature – 5 0C to +50 0C, StorageTemperature – 10 0C to +50 0C, Length -- 2meter,Type -- LC-LC Duplex etc complete as required
Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.25mm Powder Coated CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 5nos two line cable entryorexit provision at top.
Supplying and fixing of Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entryorexit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL and RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U
CCTV Network Room Accessories including network cables, patch cords, power junction box, closed raceways, cables and conduit, MCB etc, Velco for cable management etc for CCTV equipment
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduitor on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per ULorETL verification program for compliance with ANSIorTIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : less than 4 X Cable Diameter at –5°C ± 1°C and Pulling Force
25 mm Dia MS Conduit in True Ceiling or above false ceiling areas
Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990( to floor network switch and Outdoor PTZ Camera), CCTV NVR, Display and Keyboard 3 core 2.5 Sqmm.
Single Mode 12 Core Optical fiber cable
Supplying and fixing Wall mount 6U Rack or Junction Box, IP55, Front Door with Filter, Louver and Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. etc complete as required.
220 V or 24 V Power Supply Unit for Cameas
Surge Protection Device for External Camera
Supply, Installation, Testing and Commissioning of 10or100 Mbps Ethernet-to-Fiber Media Converter, with one RJ45 copper port and suitable single-modeormultimode OFC fiber port, compliant with IEEE 802.3 or 802.3u standards.Supports 10or100 Mbps auto-negotiation, fullorhalf duplex, Auto MDIorMDIX, LED status indication and suitable industrialorcommercial operating temperature range.Complete with matched pair of media converters, power adapters, connectors and accessories, suitable for CCTVorELV network applications; Moxa or Planet or Allied Telesis or Hirschmann or approved equivalent.
Rack or Junction Box Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations. 12 port LIU
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Polyvinyl Lubricated Bond (PLBorHDPE) pipe OD 40 mm to be laid inside the 120 OD dia DWC HDPE pipe
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, end, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 120 mm dia (OD-120 mm and ID-103 mm nominal)
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cableor pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Providing RCC Chambers with Airtight Cover for underground cables with minimum dimensions 600mm (W) x 600mm (L), 1000mm (D) with airtight covers as required at site.
Supply of AC Distribution Boards with MCB, 3 Pin Plug Points and Enclosures with Lock and Key arrangements as per site conditions.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5percentage, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders iorc base of suitable size GI angle, GI bolts and nuts, fastner etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5percentage, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders iorc base of suitable size GI angle, GI bolts and nuts, fastner etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Online UPS - Input supply: Single Phase, Output Supply: Single Phase. Supplying, installation, Testing and Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS Rating 2 KVA
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe (Above and Under Ground Pipe) as per IS 1239 to withstand a developing pressure of 10 bar ,kg. or sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers and joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. 80mm dia
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe (Above and Under Ground Pipe) as per IS 1239 to withstand a developing pressure of 10 bar ,kg. or sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers and joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. 65mm dia
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe (Above and Under Ground Pipe) as per IS 1239 to withstand a developing pressure of 10 bar ,kg. or sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers and joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. 50mm dia
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe (Above and Under Ground Pipe) as per IS 1239 to withstand a developing pressure of 10 bar ,kg. or sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers and joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. 40mm dia
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe (Above and Under Ground Pipe) as per IS 1239 to withstand a developing pressure of 10 bar ,kg. or sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers and joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. 25mm dia
Supply ,Installation, Testing and Commissioning of UL listed and FM approved standard response Glass bulb sprinkler pendent orUpright type rated 79 Deg. C. 115 K-Factor
Supply, Installation, Testing and Commissioning of 25mm Ball valve with necessary nipple and other fittings
Supplying, Installing, testing and commissioning of PN 16 lever operated Butterfly valve with required flanges, nuts, bolts etc. complete.32dia
Supplying, Installing, testing and commissioning of PN 16 lever operated Butterfly valve with required flanges, nuts, bolts etc. complete.65dia
Supplying, Installing, testing and commissioning of PN 16 lever operated Butterfly valve with required flanges, nuts, bolts etc. complete.50dia
Supply, Installation, Testing and Commissioning of UL listed and FM approved Flow Switches with two NO and two NC contacts with necessary nipple and other fittings65dia
Supply, Installation, Testing and Commissioning of UL listed and FM approved Flow Switches with two NO and two NC contacts with necessary nipple and other fittings50dia
Supply, Installation, Testing and Commissioning of Dial type pressure guage ( Industrial type) with necessary nipple and other fittings65dia
Supply, Installation, Testing and Commissioning of Dial type pressure guage ( Industrial type) with necessary nipple and other fittings50dia
Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of followings and complete in all respects as required. a) 1 No. horizontal split casing centrifugal type fire pump capable of delivering 2850or171m3hr LPM LPM against a total head of 70metres,Suitable head so as to ensure a minimum pressure of 3.5 kg. per sq.cm at the farthest top most hydrant or outlet with pump casing of cast iron to grade FG 200, IS 210-1978 and parts like impeller, shaft sleeve, bearing ring etc., of non-corrosive metal either like bronze, brass or gun metal and shaft of stainless steel. b) 190 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS and IS standard complete. c) Auto starting mechanism, 12 volts or 24 volts electric starting equipment like self motor, dynamo, solenoid switches, etc. d) 110 litres capacity diesel tank mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre-filter, after filter etc.
The panel will be powder coated of approved (RED) colour both inside abd out side. The panel shall have both bottom and top cable entry provisions
Supply and laying of following sizes of Armoured Aluminium or Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification a3.5 core 300 sq.mm. armoured aluminium cable
Supply and laying of following sizes of Armoured Aluminium or Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification a4 C x 16 Sqmm. armoured aluminium cable
Supply and laying of following sizes of Armoured Aluminium or Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification a12 C x 1.5 Sqmm. Copper
Supply and laying of following sizes of Armoured Aluminium or Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification a2 C x 1.5 Sqmm. Copper
Supply and laying of following sizes of Armoured Aluminium or Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification a3 C x 1.5 Sqmm. Copper
Supply and laying of following sizes of Armoured Aluminium or Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification a14C x 2.5 Sqmm. Copper Armoured Cable for Diesel Pump
Supply and laying of following sizes of Armoured Aluminium or Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification a2 C x 2.5 Sqmm. Copper Armoured Cable for instrumentations
Supply and laying of following sizes of Armoured Aluminium or Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification a1R x 4 Core 25 Sq.mm PVC Copper Armoured Cable for Jockey Pump
Supply and erection of GI Hot Dip or Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height
Supply and erection of GI Hot Dip or Powder Coated 16 SWG Cable Tray with 150mm width and 50mm height
Supply and run of 1 of No.8 SWG GI wire for earth connection
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps or supports on wall or floor or ground for earth connection
Supplying, installing, testing and commissioning of G.I Pipes confirming to IS-1239, with specials such as Tees, elbows, flanges. Including cutting, Painting, Welding, fixing in or on walls, ceiling by using suitable supports etc., 250mm Nominal dia
Supplying, installing, testing and commissioning of Heavy grade G.I. Pipes confirming to IS :1239 part - I with butt welded specials confirming to IS:1239 part - II, such as Tees, elbows, check nuts, unions, flanges, nipplesetc. Including cutting,painting Welding, fixing in or on walls, ceiling by using suitable supports, including pipes travelling under ground etc, as per drawings. 200mm Nominal dia
Supplying, installing, testing and commissioning of Heavy grade G.I. Pipes confirming to IS :1239 part - I with butt welded specials confirming to IS:1239 part - II, such as Tees, elbows, check nuts, unions, flanges, nipplesetc. Including cutting,painting Welding, fixing in or on walls, ceiling by using suitable supports, including pipes travelling under ground etc, as per drawings. 150mm Nominal dia
Supplying, installing, testing and commissioning of Heavy grade G.I. Pipes confirming to IS :1239 part - I with butt welded specials confirming to IS:1239 part - II, such as Tees, elbows, check nuts, unions, flanges, nipplesetc. Including cutting,painting Welding, fixing in or on walls, ceiling by using suitable supports, including pipes travelling under ground etc, as per drawings. 100mm Nominal dia
Supplying, installing, testing and commissioning of Heavy grade G.I. Pipes confirming to IS :1239 part - I with butt welded specials confirming to IS:1239 part - II, such as Tees, elbows, check nuts, unions, flanges, nipplesetc. Including cutting,painting Welding, fixing in or on walls, ceiling by using suitable supports, including pipes travelling under ground etc, as per drawings. 80mm Nominal dia
Supplying, installing, testing and commissioning of Heavy grade G.I. Pipes confirming to IS :1239 part - I with butt welded specials confirming to IS:1239 part - II, such as Tees, elbows, check nuts, unions, flanges, nipplesetc. Including cutting,painting Welding, fixing in or on walls, ceiling by using suitable supports, including pipes travelling under ground etc, as per drawings. 50mm Nominal dia
Supplying, installing, testing and commissioning of Heavy grade G.I. Pipes confirming to IS :1239 part - I with butt welded specials confirming to IS:1239 part - II, such as Tees, elbows, check nuts, unions, flanges, nipplesetc. Including cutting,painting Welding, fixing in or on walls, ceiling by using suitable supports, including pipes travelling under ground etc, as per drawings. 25mm Nominal dia
Supply and erection of Exhuast pipe for Diesel engine of with mineral wool insulation with aluminum sheet.- M.S. 'B' class pipe - 150 mm dia
Supplying, Installing, testing and commissioning CI Butterfly valvesorGate ValveorSluice Valve (PN 16) steam rising operated type with required flanges, nuts, bolts etc. complete.200mm nominal dia
Supplying, Installing, testing and commissioning CI Butterfly valvesorGate ValveorSluice Valve (PN 16) steam rising operated type with required flanges, nuts, bolts etc. complete.150 mm nominal dia
Supplying, Installing, testing and commissioning CI Butterfly valvesorGate ValveorSluice Valve (PN 16) steam rising operated type with required flanges, nuts, bolts etc. complete.100 mm nominal dia
Supplying, Installing, testing and commissioning CI Butterfly valvesorGate ValveorSluice Valve (PN 16) steam rising operated type with required flanges, nuts, bolts etc. complete.80mm nominal dia
Supplying, Installing, testing and commissioning CI Butterfly valvesorGate ValveorSluice Valve (PN 16) steam rising operated type with required flanges, nuts, bolts etc. complete.50mm nominal dia
Supplying, Installing, testing and commissioning CI Butterfly valvesorGate ValveorSluice Valve (PN 16) steam rising operated type with required flanges, nuts, bolts etc. complete.25mm nominal dia
Supplying, Installing, testing and commissioning NRV (Non Return Valve) (PN 16) steam rising operated type with required flanges, nuts, bolts etc. complete.150 mm nominal dia
Supplying, Installing, testing and commissioning NRV (Non Return Valve) (PN 16) steam rising operated type with required flanges, nuts, bolts etc. complete.100 mm nominal dia
Supplying, Installing, testing and commissioning NRV (Non Return Valve) (PN 16) steam rising operated type with required flanges, nuts, bolts etc. complete.80mm nominal dia
Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valves with fittings of screwed end type. . 25mm dia
Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valves with fittings of screwed end type. . 15mm dia
Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification
Supply, Installation, Testing and Commissioning of Flow meter (150mm) size with required flanges, nuts, bolts etc. complete.
Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original conditionwherever found neccessary, etc., complete as per standard specification
Providing, fixing, testing and commissioning of air vessel (size 450 mm dia and 1500mm HOS) fabricated from 10 mm thick shell and dished end 12 mm thick M.S. Plate for pressurization of hydrantor sprinklerorwater curtain system complete. 50 dia. socket for drain, 65 dia. socket for inlet, 25 dia. sockets for pressure relief valve, pressure switches and pressure gauges, 450 mm dia manholes, M.S legs, epoxy painted from inside and enamel paint from outside after grit blasting complete.
Supply, Erection, Testing and Commissioning of Metallic-Rubber bellow flexible connections of suitable pressure rating to be installed at equipments suction and discharge.with necessary fittings and accessories like flanges, GI bolts, nuts and washers, painting etc.150 NB
Supply, Erection, Testing and Commissioning of Metallic-Rubber bellow flexible connections of suitable pressure rating to be installed at equipments suction and discharge.with necessary fittings and accessories like flanges, GI bolts, nuts and washers, painting etc.100 NB
Supply, Erection, Testing and Commissioning of Metallic-Rubber bellow flexible connections of suitable pressure rating to be installed at equipments suction and discharge.with necessary fittings and accessories like flanges, GI bolts, nuts and washers, painting etc.80 NB
Supply, Installation, Testing and Commissioning of Y stainer as follows250mm dia
Supply, Installation, Testing and Commissioning of Y stainer as follows200mm dia
Supply, Installation, Testing and Commissioning of Y stainer as follows100mm dia
Supply, Installation, Testing and Commissioning of Puddle Flange orFootvalve as follows250mm dia
Supply, Installation, Testing and Commissioning of Puddle Flange orFootvalve as follows200mm dia
Supply, Installation, Testing and Commissioning of Puddle Flange orFootvalve as follows100mm dia
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe (Above and Under Ground Pipe) as per IS 1239 to withstand a developing pressure of 10 bar ,kg. or sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers and joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.150mm dia
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe (Above and Under Ground Pipe) as per IS 1239 to withstand a developing pressure of 10 bar ,kg. or sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers and joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.100mm dia
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe (Above and Under Ground Pipe) as per IS 1239 to withstand a developing pressure of 10 bar ,kg. or sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers and joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.80mm dia
Supply, Erection, Testing and Commissioning of Cast Iron Body Butterfly Isolation ValvesorSluice Valve (PN:16) with necessary fittings and accessories like flanges, GI bolts, nuts and washers, painting etc. The Valves shall be of Lever operated valves for 150NB and below and gear operated valves for 200NB and above.150mm dia
Supply, Erection, Testing and Commissioning of Cast Iron Body Butterfly Isolation ValvesorSluice Valve (PN:16) with necessary fittings and accessories like flanges, GI bolts, nuts and washers, painting etc. The Valves shall be of Lever operated valves for 150NB and below and gear operated valves for 200NB and above.100mm dia
Supply, Erection, Testing and Commissioning of Cast Iron Body Butterfly Isolation ValvesorSluice Valve (PN:16) with necessary fittings and accessories like flanges, GI bolts, nuts and washers, painting etc. The Valves shall be of Lever operated valves for 150NB and below and gear operated valves for 200NB and above.80mm dia
Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification
Supply, erection, testing and commissioning of Fire Fighting 2 Way Fire Brigade Inlet with necessary gun metal 63mm dia non-return spring shutter arrangements so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification
Supply and fixing of Fire fighting application oblique type Stainless steel or Gun Metal Single Headed Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts and nutswith washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever foundneccessary etc complete as per standard specification
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portionsto its original condition wherever found neccessary etc complete as per standard specification
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
Supply ,installation, testing and commissioning of Fire Hose Reel (as per ISI) wall mounted, swinging type18 SWG MS sheet, fitted with 19 mm dia x 30 M long, high pressure hose with 5 mm outlet GM nozzle with shut off valve (IS: 884-1969) includes GateorBall valve. and chrome plated nozzle with all necessary fixing materials complete.
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification
Supply and installation of RCC HUME Pipe of 300mm dia, with collars for road or below floor crossing of fire pipe. The rate shall include excavation, soil leveling for bed and ends shall be closed with brick masonry, work as directed by site Engineer.
Supplying, fabricating, structural steel supports such as MS channels, angles, flats, rods as required at site with anchor fasteners, clamps, threaded rods, nuts, bolts, washers etc. complete with painting for pipe support.
Supply, Installation, Testing and Commissioning of Dial type pressure guage80dia Industrial type with necessary nipple and other fittings
SITC of On-Grid Solar PV Power Plant Supply, Installation, Testing and Commissioning of on-grid Solar PV Power Plant conforming to MNRE specifications. Includes:
Earthing Station (Plate Type) CopperorGI Plate earthing 600x600x3mm with watering pipe, charcoalorchemical treatment, and masonry chamber (For LA, DC, and AC neutral pits).
Earthing Strip Supplying and laying 25x5 mm GI strip on surface or in recess for interconnection of earth pits.
External AC Cabling (Plant to Main Panel) Laying and supplying of 3.5 Core, 300 sq. mm XLPE insulated, PVC sheathed Aluminium conductor armoured cable (1.1 KV).
Cable Tray (Perforated) Supplying and fixing of hot dip galvanized perforated cable tray (300-450mm width) for safe cable routing.
Lightning Conductor (ESE) Installation of Advanced Early Streamer Emission (ESE) Lightning Arrestor with mast (if extra coverage is needed beyond standard scope).
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Cold Stroage _ 10000 MT Phase-2 BOQ.xlsx
Others - Estimate • 0.09 MB
RIDF Tranche-31 Tender Document Final.pdf
Tender Document • 1.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .