Dy.C.E.(M)/(S and D)
Office of the D.Y.CE(M)/ (S and D) SEWARAGE and DRAINAGE department Kolkata Municipal Corporation 5, S.N. Banerjee Road Kolkata-700 013 West Bengal
ARRANGEMENT OF LIGHTINING ARRESTER AT HT SWITCHGEAR ROOMS AND PUMP HOUSE UNDER KAMDAHARI DRAINAGE PUMPING STATION.
2026_KMC_1032791_1
KMC/S_D/KMPS/LA/26-27
Open Tender
Electrical Work/ Equipment
Percentage
7 days
DLPS/KMPS
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹5,100
10 Aug 2026
17 Jul 2026
30 Jul 2026
17 Jul 2026
28 Jul 2026
17 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthing Installation ... with Copper Plate electrode :Earthing with
Copper plate (6)10x610x3mm size) having weight of 9.84 Kg and 1
No. 25x5mm Copper strip (3).20 mt long) & 1 no. 6 sqmm PVC
insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI
pipe (ISI Medium) protection (4) mt. long) to be fillied with bitumen,
partly under the ground level & partly above ground level to an
average depth of 3.65 Mts. below the ground level and restoring the
surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe
(ISI Medium) FOR periodic treatment, incl. providing masonery
enclosure on the top of the earth electrode of overall size
86.36x86.36x46cm deep below Ground level) complete with
cemented brick work (1:6) of 25 cm width, duly plastered with cement
morter (inside) CI hinged inspection cover of size 36.56x35.56cm with
locking arrangement, GI reducer and treatment of soil by using salt &
charcoal or coke FOR plate electrode | - | SET | 10,466 | - |
| 2 | Extra FOR treatment of soil by using salt & charcoal or coke FOR
plate electrode | - | ITEM | 531 | - |
| 3 | Extra FOR providing masonery enclosure on the top of the earth
electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep below
Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover
of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer
including drilling of 46 nos. 12 mm dia holes on the GI pipe | - | ITEM | 915 | - |
| 4 | SCHEDULE OF RATES FOR INSTALLATION OF LIGHTNING
CONDUCTOR 14. S & F Lightning Conductor Air Terminal made of
20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge
prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16
stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate
at bottom incl. necessary holes etc. complete duly grouted on the
parapet etc. in CC mortar (4:2:1) | - | EACH | 430 | - |
| 5 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials
from K-1 to K-14 are excluding VAT)143. Copper Plate,Copper Strip | - | KILOGRAM | 510 | - |
| 6 | Earth busbar Supplying & fixing earth busbar of galvanized (HOT
Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from
wall including providing drilled holes on the busbar complete with GI
bolts, nuts, washers, spacing insulators etc. as required | - | METER | 316 | - |
| 7 | SCHEDULE OF RATES FOR INSTALLATION OF LIGHTNING
CONDUCTOR 7. Hiring charges FOR scaffolding arrangement
including dismantling at the end of work and carriage, FOR LC
installation, per storey of building per vertical run | - | EA(STORE | 155 | - |
| 8 | SCHEDULE OF RATES FOR INSTALLATION OF LIGHTNING
CONDUCTOR 4. Cutting cornices/ steps etc. including cutting recess
in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe
protection as below and mending good damages to the building
works: (b) Length above 0.5 Mtr | - | SET | 148 | - |
| 9 | SCHEDULE OF RATES FOR INSTALLATION OF LIGHTNING
CONDUCTOR 3. S & F of 4 SWG GI (Hot Dip) wire on wall FOR the
lightning conductor as required ( FOR vertical run) with GI Staples (40
mm long) spaced not exceeding 1 Mtr. apart incl. mending good the
damages to building works (excluding hire charges of scaffolding) | - | METER | 91 | - |
| 10 | SCHEDULE OF RATES FOR INSTALLATION OF LIGHTNING
CONDUCTOR 2. S & F of 4 SWG GI (Hot Dip) wire on
Parapet/Roof/Plinth/ Surface of wall FOR lightning conductor as
required ( FOR Horizontal runs) with 40 mm long GI Staples spaced
not exceeding 1300 mm apart incl. mending good all the damages to
the building works | - | METER | 79 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
BOQ_2536448.xls
BOQ • 0.29 MB
FORM.pdf
Tender Documents • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .