Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹50.9 L+₹95,155.90 (1.91%)Rejected-Finance 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹52.4 L+₹2.4 L (4.87%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹52.8 L+₹2.8 L (5.68%)Rejected-Finance A 3 257 2ND FLOOR JANAKPURI ASALATPUR ROAD JANAKPURI WEST DELHI DELHI 110058 UDYAM DL 11 0007281 | WEST DELHI | DELHI | 110058 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹56.0 L+₹6.1 L (12.1%)Rejected-Finance KRISHNA NAGAR BOOTY RANCHI 835217 | RANCHI | JHARKHAND | 835217 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
31 Jul 2021, 6:00 pmClosed
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT P.O. HOTWAR RANCHI - 834012
REPAIR AND MAINT OF LT UG CABLE, LT OH LINE, LT SWITCHGEAR AND ASSOCIATED WORKS IN MAHAR, FD HOSP, FPO IN DIPATOLI MIL STN UNDER GE DIPATOLI
2021_MES_456671_1
8000/1713/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dipatoli
Class E
Category b(i)
8 documents required · 8 mandatory
₹500
Yes
GE Dipatoli
₹50,000
Yes
24 Aug 2021
10 Jul 2021
2 Aug 2021
10 Jul 2021
31 Jul 2021
27 Jul 2021
Amount
Taking down MCCB/Change over switch by disconnecting all connections very carefully of any size and capacity and deposit to MES Store complete all as specified and directed at site by Engr-in-charge.
Supply and fix in replacement MCCB TPN 415 volts with microprocessor based release 50 Hz , 630 Amps with breaking capacity 50 KA complete all as specified and directed at site. Make : legrand/Schenider/siemens
Supply and fix in replacement MCCB TPN 415 volts with thermal magnetic release 50 Hz 500 Amps with breaking capacity 36 KA complete all as specified and directed at site. Make :legrand/Schenider/siemens
Supply and fix in replacement MCCB 4 Pole 415 volts 350 Amps 50 Hz Adjustable type, with breaking capacity 36 KA complete all as specified and directed at site. Make : legrand cat no 4220 02 /Schenider/siemens
Supply and fix in replacement MCCB TPN 415 volts 250 Amps 50 Hz Adjustable type, with breaking capacity 36 KA with breaking capacity 36 KA complete all as specified and directed at site. Make : legrand cat no 4202 39 /Schenider/siemens
Supply and fix in replacement MCCB TPN 415 volts 160 Amps 50 Hz Adjustable type, with breaking capacity 36 KA with breaking capacity 36 KA complete all as specified and directed at site. Make : legrand cat no 4200 87 /Schenider/siemens
S&F in replacement change over switch on load type 4 pole 400 Amp,415 V,50 Hz by addition/alteration to existing panel board including making all electrical connection with all materials required at site all as directed by Engineer-in- Charge. Make:- C&S/legrand/L&T
S&F in replacement change over switch on load type 4 pole 200 Amp,415 V,50 Hz by addition/alteration to existing panel board including making all electrical connection with all materials required at site all as directed by Engineer-in- Charge. Make:- C&S/legrand/L&T
M&L for disconnecting of LT Out door/Indoor panel board of any size in Dipatoli Mil Stn by taking proper electric shut down servicing and powder coated painting of LT Panel by Skilled Electric service Engineer, cleaning the indoor surface, removing dust particles by using high speed blower , tightening nut, bolts,washer etc and checking all control wire and opening aluminium/Copper cables from MCCBs/Main switches/Bus Bar and cutting of unserviceable/Burnt out/overheated cable / thimbles etc and re- fixing of new aluminium/Copper thimbles with help of crampting tool /Cable Gland /Nut,Bolts,Washer etc as per site requirement , insulation of all necked wires as per existing colour code, re-fixing/re-assembling as per existing connection complete all as specified and directed at site. Note :- (i) Cost of any addition/alteration ,welding,jointing work painting etc equired will deemed to be included in quoted rates. (ii) All consumable items such as Alu/Copper thimbles/Cable Glands, ,nut,bolts,washer etc are deemed to be included in the quoted rate. (iii) Cutting machine and painting machine or any other T&P required for the same will be arranged by the contractor at no extra cost.
M&L Heat Resistant Flame Retardant HRFR PVC Insulated Industrial flexible Cables Single Core Copper Conductor (Unsheathed) 1100 Volts of size 50 Sqmm conforming to IS:94 (Colour : Red, yellow, Blue, Black and Green as per requirement) including suitable size of copper thimbles fixed by cramping tools complete all as specified and directed at site. Make : Havells/Polycab/Plaza
Taking down old unserviceable/burn out LT cable of any size and capacity from the pole/wall/trenches after disconnecting of all electric connections etc Note:- Excavation and earth work will be measured and paid separately.
Supply,laying,jointing,testing and commissioning XLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 240 sqmm 4 core connected with aluminium lugs connected by cramping tools all as specified and directed at site.
All as per Srl items No.12 here-in-before but of size 150 sqmm x 3.5 core complete all as specified and directed at site.
All as per Srl items No.12 here-in-before but of size 120 sqmm x 3.5 core complete all as specified and directed at site.
All as per Srl items No.12 here-in-before but of size 70 sqmm x 3.5 core complete all as specified and directed at site.
All as per Srl items No.12 here-in-before but of size 50 sqmm x 3.5 core complete all as specified and directed at site.
All as per Srl items No.12 here-in-before but of size 35 sqmm x 4 core complete all as specified and directed at site.
All as per Srl items No.12 here-in-before but of size 25 sqmm x 4 core complete all as specified and directed at site.
All as per Srl items No.12 here-in-before but of size 16 sqmm x 4 core complete all as specified and directed at site.
All as per Srl items No.12 here-in-before but of size 10 sqmm x 4 core complete all as specified and directed at site.
Supply,laying,jointing,testing and commissioning PVC tape/Extruded innersheathed Aluminium unarmoured service wire, 650/1100 volts grade cross sectional area 16 sqmm 4 core connected with aluminium lugs connected by cramping tools all as specified and directed at site.
Supply,laying,jointing,testing and commissioning PVC tape/Extruded innersheathed Aluminium unarmoured service wire, 650/1100 volts grade cross sectional area 16 sqmm 2 core connected with aluminium lugs connected by cramping tools all as specified and directed at site.
Taking down/dismantling LT PCC/steel tubular poles ,studs,insulator including V clamp,cross arms , earth wire support etc and deposit to MES store complete all as specified and directed at site by Engr-in-charge.
M&L Steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410 SP-31 ( 9.00 Meters long) complete all as specified and directed at site.Note : Excavation ,earth work & PCC work shall be measured paid separately.
M&L for trenchless boring under road crossings/foot paths by manual / Boring machine complete all as specified and directed at site.
Supply and fix in replacement of 50 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc all as specified and directed at site.
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and depth beyond the first 1.5 mtr for foundation ect. Or for shafts, well, cesspits, mainholes ect. In any type of soil for foundation and getting out and levelling of bottom surface to required level all as specified and directed by engineer-in-charge
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Demolition of cement concrete in ground floor and paving built in cement concrete (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as directed..
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggaregate in kerbs/coping /bed plates and like including weathering slightly rounded or chamfered complete with necessary use and waste fo form work complete all as specified and directed at site.
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundation mass concrete and filling including weathering slightly rounded or chamfered complete with necessary use and waste fo form work complete all as specified and directed at site.
Dismantling cross- arms of MS ,channel or angle sections & Earth Wire etc complete all as specified and directed at site.
M&L mild steel as in cross arms bracing supports clamps and back planes fabricated from structural steel section including nut, bolts washers welding welding drilling holes for bolts in any shape and size as indicated or directed and inclusive of one proimer coat one under coat one finishing coat of aluminium paint complete. paint complete to support the cables all as specified.
Dismantling of ACSR conductor from OH lines any size carefully and deposited to MES store comliete all as specified and directed by Engr-in-Charge.
M&L for ACSR conductor any size for LT over head line incl stringing land fixing on pole and binding etc complete all as specified and directed at site. Note : Size of conductor will be as per site requirement as directed by Engr-in-Charge.
Dismantling of LT insulator any type any capacity all as directed by Engr-in-Charge.
M&L for shackle type porcelain vitreous white, brown or green insulator of size 100mm height 115mm dia incl nut of size 100 mm height 1100 volt grade shackle insulator all as specified.
M&L Pin type insulator porcelain vitreous white, brown or green incl one galvanized mild steel sprindle two galvanized iron washer and one galvanized iron nut 100 mm height 65 mm dia for 1100 volts grade all as specified and directed by EIC
M & L for GI stay assembly set comprising of 16mm dia 380mm iron stay bow 1800mm long stay rod 20 mm dia 300 x300x 6mm stay plate thimble GI stay wire 7/8 SWG of required length ,inclu.loop insulator,earth work and PCC complete with accessories as shown in Electrical plate No-1 all as specifies and directed by EIC.
Restringing of ACSR over head conductor including GI wire of any size/type on LT over head line with the help of rope/line wise and tighting the conductor to permissiable sag, including aluminium tape/aluminium wire complete and including trimming/cutting of tree branches of not more than 150mm dia upto the clearance of two meters all around of OH line all as specified and directed.
Supply and Fix Battery bank of 30 volt for relay operation of VCB having 15 nos battery of each capacity 2 Volts 100 Ah including compatible charing unit as directed and specified by engr-in- charge. MAKE :- Exide/Amaron/Okaya
Supply and Fix Aluminium lugs of different capacity and size as directed and specified by engr-in- charge.
Supply only tinned copper fuse wires of different current rating as directed and specified by engr-in- charge.
Supply only bronze nut, bolts and washers of different sizes as directed and specified by engr-in- charge.
M&L for painting of LT poles 9 mtr with synthetic enamel paint upto 2 mtr height with black and white paints with two coats and painting of cross arm/channel/clamp and street light bracket with aluminium paint incl making good to receive the paint incl base paint strips with synthetic enamel paint of approved colour all as shown & directed.
Material and labour for painting to existing LT steel tubular poles of sizes 9 mtr including bracket and other accessories as per site requitrement after preparing/ scraping the metal surface with emery sheet in all respect for making smooth surface and painted with one coat coat of aluminium paint including writing pole No/ feeder No and supply and fix of superior quality self adhesive water proof photo reflective tape in two lines on poles as directed (tape size and tint shall be as approved by Department) as per site requirement complete all as specified as directed.
M&L for cutting of tree branches including cutting of trunk branches & stacking of serviceable material and disposal of unsv materials to a distance not exc 50 mtr & clearing site all as specified and directed at site. Note : up to 50 mtr length to be measured as one span
Bush cutting / cleaning of grass with proper tools and equipments in various AGE E/M installations, clearing the bushes & grass below OH line and removal of waste material from the site 50 mtr away and as directed and specified by engr-in- charge.
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 32 x 6 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I filling with charcoal dust , and common salt , including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate.
M & L , hardcore of gauge n-exc. 40mm, deposited ,spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface. Note:- Hardcore of gauge not exceeding 40mm shall executed near base of electric poles, LT/HT panels, 02 and 04 pole structures etc.
S&F GI earth strip (32x6) mm strip with and including necessary clamps, nut bolts laid in ground complete all as specified and as directed.
M & L Attending day to day Street light/bldg security light/High mast light complaints (Street lights /building security light /Hight mast light fitted on poles/buildings at height up to 10-20 mtr from ground level), repair/replacement of unserviceable accessories like LED driver, acrylic covers, nuts, bolts, GI clamps,GI Bracket,cables, wires, MCB's, earthing, earthing strip, earth wire, Feeder Pillar, MCB, MCCB's, bus bars, HRC fuses, rewirable fuses, contactor, timers, connector, wires, cables glands, thimbles etc and making the street light fully functional complete all as per the instruction of JE E&M / Engineer in Charge including excavation,returning filling,removing and cost of Tower wagon, cable fault locator equipment and all required tools, ladders, safety belt, labour and all other incidental operations required for execution of street light light maintenance work are included for smooth operation. Note: - (i) Cost of spares and accessories will be measured and paid seperatly under relevent items. (ii) Cost for taking down and re-fixing new parts shall be deemed to be included in the unit rate quoted. (iii)Recovery shall be made from Contractor @ Rs. 50/- per complaint/ Hours, if he fails to attend and rectify the complaint within 48 hours of lodging the complaint either personally / telephonically/Email. In this regard the decision of the Engr-in-Charge shall be final & binding.
Dismantling and taking down old unserviceable street light fitting/bldg security light fittings/High Mast Light fitting/Post top laltern of any capacity from upto 20 mtr height of pole /wall incl disconnecting the cable connections complete all as specified and directed.
Disconnecting electrically and taking out unserviceable nature switch box, feeder pillar box any type and size and removing material from site including making good of disturbed surfaces complete all as specified and directed.
Taking down carefully copper/aluminium wiring of size 1.5/2.5 sqmm from surface at any height of pole and removing the materials from site and making good the disturbed surfaces etc complete all as specified and directed.
Taking down XLPE cable and high mast cable from any height of pole and removing the materials from site and making good the disturbed surfaces etc complete all as specified and directed.
S & F Pressure die cast aluminum alloy housing LED street light fitting 72 Watt comprises of pressure die cast Aluminium housing & having system efficiency>110 lumens/Watt i.e 6670 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto 440 v for 8 hr,IP66 Protected, THD<10%,CRI>70 CCT 5700+/-300K, PF>0.9, Driver efficiency>85%,LM79 report require from NABL Accediated lab all as directed by Engr-in-Charge. Make : Crompton cat part No. LSTP-72-CDL-M or equivalent in Jaguar /Philips.
S & F Pressure die cast aluminum alloy housing LED street light fitting 90 Watt comprises of pressure die cast Aluminium housing & having system efficiency>110 lumens/Watt i.e 6670 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected,THD<10%,CRI>70CCT 5700+/-300K, PF>0.9, Driver efficiency>85%,LM79 report require from NABL Accediated lab all as directed by Engr-in-Charge. Make : Crompton cat part No. LSTP-90-CDL-M or equivalent in Jaguar /Philips.
Supply & Fix LED flood light ftg 150 Watts , Incl Driver unit assy with surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected, Make : crompton Cat part No LFNL-150-CDL/60-M or equivalent in Havells /Philips
Supply and fix in replacement garden light lantern cast aluminium tripod type LED Bollard with soft 360 deg with clear acrylic cover with LED lamp complete all as specified and directed at site. Make : crompton /Havells/ HPL
Supply and fix in replacement post top lantern cast aluminium spigot,spun aluminium canopy with clear acrylic cover with 20 Watt LED lamp including all accessories such as Bracket,GI Pipe and prewired complete all as specified and directed at site. Make : Bajaj /Havells/ HPL
Nature Switch street light controller three phase 5 KW of automatic street light switch using infrared sensor based NATURAL SWITCH for automatic switching of street lights, required illuminance for switching on is ≤30 Lux and for switching off ≥10 Lux also having part night operation 4 to12 hour with contactors and outgoing and incoming MCBs connected with min 10sqmm FLRS multistranded circuit all these must be enclosed in a pole/wall mounted enclosure made of rust proof, electric shock proof and termite proof conforming to IP54 complete all as specified and directed by engineer in charge
S&F power conactor type 1P auxilary contact 1NO 1 NC coil voltage 230V AC,32 A, 50 HZ suitable for timer switch of street light complete all as specified and directed complete all as specified and directed at site. Make : L&T/Schneider/Siemens
M & L Unsheated 5 core of 6 sqmm insulated, Unarmoured, heavy duty electric cable with Copper conductor, 1100 Volts grade suitable for High Mast light, all as directed by Engineer-in-Charge. Make: Havell's/Poly Cab/RR cable
Supply,laying,jointing,testing and commissioning PVC tape/Extruded innersheathed Aluminium unarmoured service wire, 650/1100 volts grade cross sectional area 10 sqmm 4 core connected with aluminium lugs connected by cramping tools all as specified and directed at site.
Supply fixing and fabricating tray holding cross arms FI clamps support U clamps strips and back plates fabrication from structural steel section incl nut bolts washer bars etc of required size and thickness for supporting of cable tray by welding incl bending or welding cold or hot,drilling holes for bolt in any shape or size indicated or included of one coat primer coat under one finishing coat of black paint complete to support the cables all as specified.
Supply and fixing in replacement of street light cable junction box of size 155x155x100 mm with terminals fixing on pole with 25x4 mm aluminium strip clamp with nut,bolts and washer etc Make : Hensel or equivalent as per list of makes
S&F in replacement service bracket for street light fitting made out of 40 mm bore light grade GI pipe of length 1.5 mtr long (approx) bend to shape 115 degree and fix to pole for fixing of street light fitting on pole/wall etc fixed with 2 Nos 32x 6 mm GI clamp, Nut,bolts,washer etc complete all as specified and directed.Make:JINDAL/BST/TATA
Supply and fix 1.5 Sqmm, single core Two runs PVC insulated and unsheathed FR cable 1100 Volts grade with multistranded copper conductor and one run of 1.5 Sqmm cable for common earth dolly drawn through heavy duty PVC conduit for street light pole including connection from kiosk box to street light fittings complete all as specified and directed. Make- Polycab/Havells/Anchor
All as per ser item No.34 here-in-before but 2X 2.5 Sqmm and 1X 2.5 Sqmm for Earth wire complete all as specified and directed.
Supply only single core copper conductor PVC insulated unsheathed FR 1100 Volt grade 1.5 Sqmm size,multistranded unsheathed complete all as specified and as directed. Make : Polycab/Havells/Anchor
Supply only LED driver unit suitable for 60 watt LED Fitting complete all as specified and directed at site.Make : Havells /Jaguar/HPL
Supply only LED driver unit suitable for 72 watt LED Fitting complete all as specified and directed at site.Make : Havells /Jaguar/HPL
Supply only LED driver unit suitable for 90 watt LED Fitting complete all as specified and directed at site.Make : Havells /Jaguar/HPL
Supply only LED driver unit suitable for 120 watt LED Fitting complete all as specified and directed at site.Make :Havells /Jaguar/HPL
Supply only MCB SP 06 to 32 Amp 10 KA, 'C' curve 230 Volt complete all as specified and directed at site.Make : Havells Cat Part No.DHMGCSPF006-032 or equivalent in Schenider/Legrand
Supply only MCB DP 63 Amp complete all as specified and directed at site.Make : Havells Cat Part No.DHMGCDPF063 or equivalent in Schenider/Legrand
Supply only MCCB capacity 63 Amps , 415 V, 16 KA 3 pole with thimbles/lugs and nut,bolts complete all as specified and directed at site. Make : INDOASIAN Cat Part No.830006 or equivalent in Havells/Schneider
Supply only Heavy duty PVC Non metallic conduit of external dia 20 mm complete all as specified and directed at site.Make : Anchor/Polycab/Plaza
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of depth not less than 0.90x 0.60 x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 25x4 mm, 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth lead protection pipe light gade GI of size 32/40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I connected to earthing lead with Main switch/main control board,filling with charcoal dust, and common salt, including necessary excavation and earth work in any type of soil ,perforated watering pipe,funnel with wire mesh,earth lead protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm top of GI Plate.
S&F GI strip of size 25x4 mm connected both ends with necessary bolts, nuts & washrs complete all as specified and directed.
Supply only copper wound Ballast 250 watt 230 volt suitable for 250 watt MH/SV lamp complete all as specified and directed at site.Make : Havells Cat Part No.LHGMCJENEAC1250 or equivalent in Crompton/Philips
Supply Metall hallide lamp 250 watt E-40, 230 volt complete all as specified and directed at site.Make : Havells Cat Part No.LHLQABIGUC8O250 or equivalent in Crompton/Philips
Supply only T-5 electronic ballast suitable for 2x24 watt Fitting, complete all as specified and directed at site.Make : Havells Cat Part No.LHBTO1224034 or equivalent in Crompton/Philips
Supply Only T-5 FTL 24 watt 230 volt, suitable for 2x24 /4x24 Watt fitting complete all as specified and directed at site.Make : Havells Cat Part No. LHST 27 124699 or equivalent in Crompton/Philips
Supply only CFL 4 pin 36 watt 230 volt, 2 ft long complete all as specified and directed at site.Make : Havells /HPL/ Crompton
M K Enterprises
A P ENTERPRISES
Capital Construction Company
M/S OMANIA ENTERPRISES
M/s Ray construction
M/S C L GUPTA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .