| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC | ₹44.9 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹45.6 LRejected-Finance | ₹45.6 L | L2 | Rejected-Finance Quoted High Rates |
| 3 | L3₹46.1 LRejected-Finance | ₹46.1 L | L3 | Rejected-Finance Quoted High Rates |
| 4 | L4₹49.5 LRejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | ₹49.5 L | L4 | Rejected-Finance Quoted High Rates |
| 5 | L5₹52.1 LRejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹52.1 L | L5 | Rejected-Finance Quoted High Rates |
| Sl No | Description | Qty | Unit | MSR INFRATECH L1 | PACHAR BROTHERS L3 | M/S BUDHRAM BISHNOI L5 | AABIA CONSTRUCTION L2 | M/S Shree Ram Enterprises L6 | PAREEK AND COMPANY L4 | J AND K CONSTRUCTION CO L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement including taking down cement plaster of any description, any thickness from internal surface complete all as specified and as directed. | 590 | Sqm | 220 ₹1.3 L | 180 ₹1.1 L | 199 ₹1.2 L | 185 ₹1.1 L | 210 ₹1.2 L | 150 ₹88,500 | 230 ₹1.4 L |
| 2.00 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement including taking down cement plaster of any description, any thickness from internal surface complete all as specified and as directed. | 2,000 | Sqm | 220 ₹4.4 L | 200 ₹4 L | 229 ₹4.6 L | 145 ₹2.9 L | 212 ₹4.2 L | 150 ₹3 L | 240 ₹4.8 L |
| 3.00 | M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement including taking down cement plaster of any description, any thickness complete, all as specified and directed. | 250 | Sqm | 210 ₹52,500 | 200 ₹50,000 | 199 ₹49,750 | 155 ₹38,750 | 210 ₹52,500 | 150 ₹37,500 | 240 ₹60,000 |
| 4.00 | M&L for complete removal of old existing treatment on walls on external surfaces upto 10 mtr height including roof projection, facia, cornices etc by scrapping with mechanical sander/paint remover machine (having mechanical vaccum mechanism), loose paint etc by skilled labour complete all as specified and as directed. | 24,500 | Sqm | 3 ₹73,500 | 5 ₹1.2 L | 11 ₹2.7 L | 6 ₹1.5 L | 6 ₹1.5 L | 10 ₹2.5 L | 9 ₹2.2 L |
| 5.00 | M&L for applying acrylic resistant readymade wall care putty of average 1mm thickness over the plastered/old prepared painted surfaces of external walls/ RCC surfaces/ soffits of chajjas/ roof projections/ cantilevers/ balcony etc (thickness vary as required for desired smoothness and levelling of surfaces in one or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and as directed.
Notes: (i) The prepared surface after wall putty, the contractor shall inform to the GE as well as to the Engineer-in Charge for site inspection before applying further external finishes. Please note that the further external finishes work shall start only after approval of the prepared surface from the GE as well as to the Engineer in-Charge through site order. | 26,500 | Sqm | 20 ₹5.3 L | 25 ₹6.6 L | 23 ₹6.1 L | 28.5 ₹7.6 L | 27 ₹7.2 L | 30 ₹8.0 L | 25 ₹6.6 L |
| 6.00 | M&L for one coat of acrylic water based exterior grade primer (undulated surfaces) diluted with water in ratio primer and water in (1:1) and applied with roller for painting of subsequent coats complete all as specified and as directed. | 26,500 | Sqm | 15 ₹4.0 L | 15 ₹4.0 L | 11 ₹2.9 L | 23 ₹6.1 L | 17 ₹4.5 L | 10 ₹2.6 L | 14 ₹3.7 L |
| 7.00 | M&L for applying two coats of 100% Premium acrylic smooth exterior emulsion of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, two coats with water as per manufacturer's instructions applied over primed surfaces with roller of paint application complete all as specified and as directed. | 26,500 | Sqm | 40 ₹10.6 L | 40 ₹10.6 L | 49 ₹13.0 L | 48.5 ₹12.9 L | 63 ₹16.7 L | 50 ₹13.3 L | 58 ₹15.4 L |
| 8.00 | M&L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and as directed. | 250 | Sqm | 10 ₹2,500 | 15 ₹3,750 | 19 ₹4,750 | 17 ₹4,250 | 18 ₹4,500 | 40 ₹10,000 | 20 ₹5,000 |
| 9.00 | M&L for preparation of old decorated plastered surface of walls by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts , treating oil and greasy spots and applying two coats of white wash complete all as specified and as directed. | 5,000 | Sqm | 12 ₹60,000 | 15 ₹75,000 | 19 ₹95,000 | 5 ₹25,000 | 12 ₹60,000 | 20 ₹1 L | 14 ₹70,000 |
| 10.00 | M&L for preparation of old decorated plastered surface of ceiling by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts , treating oil and greasy spots and applying one coat of white wash complete all as specified and as directed. | 1,000 | Sqm | 10 ₹10,000 | 10 ₹10,000 | 11 ₹11,000 | 7 ₹7,000 | 12 ₹12,000 | 10 ₹10,000 | 10 ₹10,000 |
Updated dates
Tender Value
₹59.6 L
EMD Value
₹1.1 L
Closing Date
9 Dec 2025, 6:00 pmClosed
Col Shery Goel
HQ CWE Bikaner Bikaner Military Station
Smart Periodical services of OTM Accn Zone-A under AGE B R-II at Suratgarh Mil Stn
2025_MES_738404_1
CA No CWE BKN-Token No 70/2025-2026
Open Tender
Civil Works
270 days
Suratgarh
Please refer tender documents
7 documents required · 7 mandatory
₹1,000
GE (A) Suratgarh
₹1.1 L
12 Jan 2026
4 Nov 2025
16 Dec 2025
4 Nov 2025
9 Dec 2025
25 Nov 2025
4 Nov 2025 - 11 Nov 2025
Amount
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement including taking down cement plaster of any description, any thickness from internal surface complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement including taking down cement plaster of any description, any thickness from internal surface complete all as specified and as directed.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement including taking down cement plaster of any description, any thickness complete, all as specified and directed.
M&L for complete removal of old existing treatment on walls on external surfaces upto 10 mtr height including roof projection, facia, cornices etc by scrapping with mechanical sander/paint remover machine (having mechanical vaccum mechanism), loose paint etc by skilled labour complete all as specified and as directed.
M&L for applying acrylic resistant readymade wall care putty of average 1mm thickness over the plastered/old prepared painted surfaces of external walls/ RCC surfaces/ soffits of chajjas/ roof projections/ cantilevers/ balcony etc (thickness vary as required for desired smoothness and levelling of surfaces in one or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and as directed. Notes: (i) The prepared surface after wall putty, the contractor shall inform to the GE as well as to the Engineer-in Charge for site inspection before applying further external finishes. Please note that the further external finishes work shall start only after approval of the prepared surface from the GE as well as to the Engineer in-Charge through site order.
M&L for one coat of acrylic water based exterior grade primer (undulated surfaces) diluted with water in ratio primer and water in (1:1) and applied with roller for painting of subsequent coats complete all as specified and as directed.
M&L for applying two coats of 100% Premium acrylic smooth exterior emulsion of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, two coats with water as per manufacturer's instructions applied over primed surfaces with roller of paint application complete all as specified and as directed.
M&L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of old decorated plastered surface of walls by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts , treating oil and greasy spots and applying two coats of white wash complete all as specified and as directed.
M&L for preparation of old decorated plastered surface of ceiling by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts , treating oil and greasy spots and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel and steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified and as directed.
M&L for complete removal of old existing treatment on walls on internal surfaces including pillars etc by scrapping with mechanical sander/paint remover machine (having mechanical vaccum mechanism), loose paint etc by skilled labour complete all as specified and as directed.
M&L for applying acrylic resistant readymade wall care putty of average 1mm thickness over the plastered/old prepared painted surfaces of internal walls (thickness vary as required for desired smoothness and levelling of surfaces in one or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving interior painting complete all as specified and as directed. Notes: (i) The prepared surface after wall putty, the contractor shall inform to the GE as well as to the Engineer-in Charge for site inspection before applying further external finishes. Please note that the further external finishes work shall start only after approval of the prepared surface from the GE as well as to the Engineer in-Charge through site order.
M&L for one coat of acrylic water based interior grade primer (undulated surfaces) diluted with water in ratio primer and water in (1:1) and applied with roller for painting of subsequent coats complete all as specified and as directed.
M&L for applying two coats of 1st quality acrylic interior emulsion distemper (Ready mixed) of approved colour with low VOC content, two coats with water as per manufacturer's instructions applied over primed surfaces with roller of paint application complete all as specified and as directed.
M&L for Acrylic polymer base damp proof coating system with two components ready to use acrylic polymer modified damp proof coating:- (a) Surface preparation: Remove the existing plastered surfaces with efflorescence/seepage area. Non-moving cracks having width upto 5mm shall be filled with polymer based crack filler. (b) Application: Apply acrylic polymer base damp prrof coating by brush roller over SSD surafce. Apply first coat of damp proof coating with a paint brush directly on the surfaces. A llow to dry for a minimum 2-3 hrs, apply subsrquent second coat after drying. The first coat and second coat shall be applied in perpendicular direction. The coverage shall be atleast 1.2 Sqm/Kg/coat. The mixing for two components, if required shall be done as per manufacturer's specifications. Rendering to be carried out after approval of Engr-in-charge and shall be paid seperately. Make: Asian Paints Damp proof Ultra 2K/Fosroc Damp Protect/Dr Fixit Dampguard. Note: Treatment shall be carried out through Authorised applicators.
M&L for preparation of old decorated plastered or unplastered surface of walls by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts , treating oil and greasy spots and applying one coat of cement base paint complete all as specified and as directed.
M&L for preparation of old decorated plastered or unplastered surface of walls by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts , treating oil and greasy spots and applying two coats of cement base paint complete all as specified and as directed.
M&L for writing letters obliterating old writing of any description, not exc 0.10 Sqm with paint to match with existing work complete all as specified and as directed.
Material and labour for jodhpur stone slab challas laid to slope supported at ends with mild steel angle iron framed sections of size 45x45x6mm fixed in wall including dismantling existing RCC chajjas and making good existing surfaces complete all as specified and as directed.
S&F in repair 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces and hacking out old broken glasses complete all as specified & as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
NOTES FOR SERIAL ITEM NO. 4.00 to 7.00 & 13.00 to 17.00 of BOQ (Contd). (k) GUARANTEE OF PERIODICAL SERVICES : Periodical services against serial item No 4.00 to 7.00 & 13.00 to 17.00 of BOQ using mechanized equipment’s only executed under this contract are under the guarantee of contractor for 05 (Five) Years after the certified physical completion of work. Contractor is fully liable under this guarantee to rectify and redo all defective work intimated to him during this period including all type of materials and labour to the specifications catered for in the contract. In case contractor fails to rectify the defective work, Accepting Officer shall get the rectification done as necessary at the risk and cost of contractor and recover the cost in full from the contractor. If the contractor consider that any additional treatment is required over and above that specified here in before in Schedule ‘A’, the same shall be carried out by the contractor without any extra cost to the Government.
AABIA CONSTRUCTION (BID ID -3487672)
PACHAR BROTHERS (BID ID -3486137)
PAREEK AND COMPANY (BID ID -3492967)
M/S BUDHRAM BISHNOI (BID ID -3487202)
M/S Shree Ram Enterprises (BID ID -3487934)
J AND K CONSTRUCTION CO (BID ID -3492759)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_826806.xls
BOQ • 0.33 MB
Tender70.pdf
Tender Documents • 0.76 MB