| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.8 LAdmitted-Finance | -28.50% | ₹14.8 L | L1 | Admitted-Finance |
| 2 | L2₹15.8 LAdmitted-Finance | -23.65% | ₹15.8 L | L2 | Admitted-Finance |
| 3 | L3₹16.2 LAdmitted-Finance | -22.00% | ₹16.2 L | L3 | Admitted-Finance |
| 4 | L4₹17.6 LAdmitted-Finance NIMOO | KAKCHING | MANIPUR | 795101 | -15.03% | ₹17.6 L | L4 | Admitted-Finance |
Tender Value
₹20.7 L
EMD Value
₹41,480
Closing Date
29 Nov 2025, 4:00 pmClosed
Executive Engineer construction division Leh.
Executive Engineer construction division Leh.
Expansion of corridor of Gynae ward and up gradation of Dialysis Unit (Under Capex)
2025_PWD_17881_3
133 of CDL Leh of 2025-26
Open Tender
Civil Works - Buildings
60 days
Leh
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer construction division Leh.
₹41,480
2 Mar 2026
22 Nov 2025
1 Dec 2025
22 Nov 2025
29 Nov 2025
22 Nov 2025
Earth work in excavation by mechanical means (Hydraulic excavator) in foundationtrenchesordrains(notexceeding1.5minwidthor10sqmonplan), includingdressingof sidesandrammingofbottoms, liftupto1.5m, including gettingouttheexcavatedsoilanddisposalofsurplusexcavatedsoilasdirected, within a lead of 50 m. All kinds of soil.
Dry stone pitching (any thickness) excluding cost of stones. On Horizontal
Randomrubblemasonrywithhard stone in foundation andplinth including levellingupwithcementconcrete1:6:12(1cement :6coarsesand:12graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing andreinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for a) Foundations, footings, bases of columns, etc. for mass concrete
b) Columns, piers, abutments, pillars, posts and struts
c) Lintel, beams, plinth beams, girders, bressumers and cantilevers
d) Suspended floors, roofs, landings, balconies and access platforms.
Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size)
Cement concrete flooring1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate) finished 40 mm thick with 20 mm nominal size stone aggregate
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand)
Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. Ordinary cement finish using ordinary cement
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coat
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windowscomprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profilesduly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process ofrequired length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated)casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusionwelded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixinghardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wallshall be filled with weather proof silicon sealant over backer rod of required size and of approved quality,all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes andsilicon sealant shall be paid separately). Variation in profile dimension in higher side shall be acceptedbut no extra payment on this account shall be made. Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partitionetc. with 6mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminiumspacers, desiccants, silicon sealant (Both primary and secondary sealant)etc.asperspecifications,drawingsanddirectionofEngineer-in-charge complete
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class Kail wood
French spirit polishing : Two or more coats on new works including a coat of wood filler
Providingand layingVitrifiedtiles infloorwithdifferent sizes (thickness tobe specifiedby themanufacturer), withwater absorption less than 0.08%and conformingtoIS:15622,ofapprovedbrand&manufacturer, inall coloursand shade, laidwithcement basedhighpolymermodifiedquickset tileadhesive (waterbased) conformingto IS : 15477, inaverage6mmthickness, including grouting of joints (Payment for grouting of joints to be made separately). 11.49.1 Size of Tile 600x600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
ProvidingandlayingrectifiedGlazedCeramicfloor tilesofsize300x300mmor more(thicknesstobespecifiedbythemanufacturer),of1stqualityconformingto IS :15622,ofapprovedmake,inall colours, shades,exceptWhite, Ivory,Grey, FumeRedBrown, laidon20mmthickCementMortar1:4(1Cement :4Coarse sand),[email protected]/sqmincludingpointingthejoints with white cement and matching pigments etc., complete.
Providing and fixing PVC soil waste and vent pipe of required dia including bends,Tee door bend,L bend trap jointed with addisive material ISI marked like Prince vector or equvilent brand all complete a)150.mm
Providing and fixing of material for the insulation of water storage tank of with nitrile sheet taping with cello tape, rockwool 6 inch per side, wire mesh, polythene, alluminium sheet 26 gage cladding with dia of, complete job 19mm thick nitrile sheet.
Providingandplacingonterrace(atall floor levels)polyethylenewaterstorage tank ISI :12701markedwithcoverandsuitablelockingarrangementandmaking necessary holesfor inlet,outletandoverflowpipesbutwithout fittingsandthe base support for tank
Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size betweencavity wall, complying with ISO 4898:2008 & ASTM C 578 08b- type VI, having thermal conductivity of0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed asper ASTM D 1621, density of 34-36 kg/m3 as per ASTM D 1622, water absorptions < 1% by volume as perASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) asper ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 classA, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
10cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar with bhusha @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 2 cow-dung) and covered with machine moulded tile bricks, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat. With machine moulded common burnt clay F.P.S. (non modular) brick tiles of class designation 12.5, conforming to IS 2691
Filling availableexcavatedearth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm indepth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Demolishingcementconcretemanually/bymechanicalmeansincludingdisposalof material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
DemolishingR.C.C.workmanually/bymechanicalmeans includingstackingof steelbarsanddisposalofunserviceablematerialwithin50metres leadasper direction of Engineer - in- charge. In cement mortar
Demolishingbrickworkmanually/bymechanicalmeans including stackingof serviceablematerialanddisposalofunserviceablematerialwithin50metreslead as per direction of Engineer-in-charge. In cement mortar
Providing and fixing of material for the insulation of pipe with nitrile tube , tapping with cello tape , Rockwood 6 inch per side, wire mesh, polythene , tapping with cello tape aluminum sheet 26 gauge cladding with dia . complete job including carriage.A)19 mm thick, 50 mm dia (OD) ( PPR 32 mmm)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately): For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according t
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood par
Carriage of material by MT including loading, unloading and site by complete job a) Cement /Steel an avg lead upto 02 km
c) Stone an avg lead 15 km
b) Sand avg lead of 15 km
c) Agg an avg lead 15 km
b) 3 pin 5/6 A socket outlet
stage.html
html • 0.03 MB
technical_43647.pdf
techsummary_43647.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
BOQ_43647.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid