| Sl No | Description | Qty | Unit | NEW INDIA ELECTRICAL AND ENGINEERING WORKS L1 | SREEKRISHNA ENGINEERING ENTERPRISE L3 | ELECTRICAL ASSOCIATES L2 |
|---|---|---|---|---|---|---|
| 1.00Fabrication,Supplying, Installation, Testing & Commissioning of cubical construction floor mounted type, fabricated in compartmentalized design CRCA sheet ( thickness at sheet 3.0 mm) with hinged lockable doors, dust and vermin proof powder coated of approved shade after 7 tank treatment process panel board (Min IP-42), having size (1700 mm x 1800mm x 250 mm), suitable for 415V 3phase ,4wire,50Hz ,AC supply, busbar of 600A capacity ,detachable gland plate,with suitable size MS channel frame at the bottom,with adequate size cu wire ,copper bar ,cu link cable connector etc along with necy nuts,bolts,clamps,grounting bolts incl providing and fixing the following accessoried etc complete as required .(Make to be approved by E.I.C).The panel should construct as per G.T.P in annexure [ In separate sheet] . [ An Auto Cad Drawing of the panel has to approved by EIC before making of panel.] | ||||||
| 1.10Incoming: a) 400A rating 4 pole 415V, 36kA MCCB - 1 Nos with accessories like spreader link and rotory handle L&T/ABB/Schneider/Seimens. b) 600A (40x 10 mm2), 500V; 4 bar Electrolytic copper busbar. | ||||||
| 1.20 | Outgoing:
a)100 A TPN SFU with necessary accessories - 1 nos L&T/ABB/Siemens
b)125 A TPN SFU with necessary accessories - 6 nos L&T/ABB/Siemens
c)250A TPN SFU with necessary accessories - 1 nos L&T/ABB/Siemens c)CT ratio 500/5Amp - 3 nos [M: Kappa] L&T/Schneider
e)Multifunctional Meter (Legrand/ABB/Siemens) - 1 nos (Accuracy Class 1.0) f)LED indication lamp with 6A SPMCB - 3 nos [L&T/ABB/Legrand/Schneider] g)Danger Notice Board | 1 | Each Item | 2,47,000 ₹2,47,000 Lowest | 2,48,000 ₹2,48,000 | 2,47,500 ₹2,47,500 |
| 2.00 | Carefully dismantling 2 nos. of existing cubical LT panels from their installed positions. Take proper precautions to avoid damage to reusable parts and surrounding structures. Disconnect and remove all associated power and control cables, including cable sockets, glands etc. Ensure safe termination of insulation of exposed cable ends as per safety standards. Dispose all non-reusable or damaged components as per applicable norms.
Installation of 1 No. Cubical Panel:
Reinstall 1 no. cubical panel at the designated location as per the layout and instruction of the Engineer-in-Charge (EIC) by Wall Grouting and Fixing: Perform necessary civil work, such as drilling, grouting, and wall anchoring to mount the panel securely. Use appropriate anchor bolts, frames, and grouting compounds for sturdy and vibration-free installation. Reinstall all Switch Fuse Units (SFUs). Ensure proper alignment and mechanical fixing inside the panel compartments. Carry out internal wiring within the panel as per the approved schematic. Connect incoming and outgoing power cables, control wires, and earthing connections as directed. Use proper size cables, lugs, glandings, and insulating sleeves per standards. Perform continuity, insulation, and phase sequence checks. Ensure tightness of all terminations and phase identification tagging. Carry out testing of functionality of the panel and devices post-installation. | 1 | Each Item | 8,000 ₹8,000 Lowest | 8,200 ₹8,200 | 8,050 ₹8,050 |
| 3.00 | Supply & Laying of cable 4 core 95 sqmm Armoured Aluminium cable (Make - Polycab / Havells / Gloster/RR/KEI/Finolex) on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting | 20 | Per Mtr. | 1,030 ₹20,600 Lowest | 1,100 ₹22,000 | 1,120 ₹22,400 |
| 4.00Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables incl. finishing by dowells solderless socket as to GS as below : | ||||||
| 4.10 | 3½ core 185 sq mm | 2 | Per Set | 800 ₹1,600 Lowest | 820 ₹1,640 | 800 ₹1,600 Lowest |
| 4.20 | 3½ core 95 sq mm | 2 | Per Set | 400 ₹800 Lowest | 420 ₹840 | 415 ₹830 |
| 4.30 | 3½ core 70 sqmm | 14 | Per Set | 300 ₹4,200 Lowest | 320 ₹4,480 | 315 ₹4,410 |
| 4.40 | 3½ core 50 sqmm | 4 | Per Set | 200 ₹800 Lowest | 220 ₹880 | 215 ₹860 |
Tender Value
Refer Docs
EMD Value
₹5,880
Closing Date
22 Aug 2025, 12:00 pmClosed
AEWBESDPWD
Block I First Floor Writers Buildings Kolkata 700001
Supply, Installation, Testing and commissioning of a new cubical type panel including dismantling of one old cubical Panel and shifting another cubical panel at Writers Building Block-I, Ground Floor.
2025_WBPWD_887924_1
WBPWD/AE/WBESD/eNIQ-18 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Writers Buildings
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,880
4 Aug 2026
6 Aug 2025
25 Aug 2025
6 Aug 2025
22 Aug 2025
11 Aug 2025
Amount
Fabrication,Supplying, Installation, Testing & Commissioning of cubical construction floor mounted type, fabricated in compartmentalized design CRCA sheet ( thickness at sheet 3.0 mm) with hinged lockable doors, dust and vermin proof powder coated of approved shade after 7 tank treatment process panel board (Min IP-42), having size (1700 mm x 1800mm x 250 mm), suitable for 415V 3phase ,4wire,50Hz ,AC supply, busbar of 600A capacity ,detachable gland plate,with suitable size MS channel frame at the bottom,with adequate size cu wire ,copper bar ,cu link cable connector etc along with necy nuts,bolts,clamps,grounting bolts incl providing and fixing the following accessoried etc complete as required .(Make to be approved by E.I.C).The panel should construct as per G.T.P in annexure [ In separate sheet] . [ An Auto Cad Drawing of the panel has to approved by EIC before making of panel.]
Incoming: a) 400A rating 4 pole 415V, 36kA MCCB - 1 Nos with accessories like spreader link and rotory handle L&T/ABB/Schneider/Seimens. b) 600A (40x 10 mm2), 500V; 4 bar Electrolytic copper busbar.
Outgoing: a)100 A TPN SFU with necessary accessories - 1 nos L&T/ABB/Siemens b)125 A TPN SFU with necessary accessories - 6 nos L&T/ABB/Siemens c)250A TPN SFU with necessary accessories - 1 nos L&T/ABB/Siemens c)CT ratio 500/5Amp - 3 nos [M: Kappa] L&T/Schneider e)Multifunctional Meter (Legrand/ABB/Siemens) - 1 nos (Accuracy Class 1.0) f)LED indication lamp with 6A SPMCB - 3 nos [L&T/ABB/Legrand/Schneider] g)Danger Notice Board
Carefully dismantling 2 nos. of existing cubical LT panels from their installed positions. Take proper precautions to avoid damage to reusable parts and surrounding structures. Disconnect and remove all associated power and control cables, including cable sockets, glands etc. Ensure safe termination of insulation of exposed cable ends as per safety standards. Dispose all non-reusable or damaged components as per applicable norms. Installation of 1 No. Cubical Panel: Reinstall 1 no. cubical panel at the designated location as per the layout and instruction of the Engineer-in-Charge (EIC) by Wall Grouting and Fixing: Perform necessary civil work, such as drilling, grouting, and wall anchoring to mount the panel securely. Use appropriate anchor bolts, frames, and grouting compounds for sturdy and vibration-free installation. Reinstall all Switch Fuse Units (SFUs). Ensure proper alignment and mechanical fixing inside the panel compartments. Carry out internal wiring within the panel as per the approved schematic. Connect incoming and outgoing power cables, control wires, and earthing connections as directed. Use proper size cables, lugs, glandings, and insulating sleeves per standards. Perform continuity, insulation, and phase sequence checks. Ensure tightness of all terminations and phase identification tagging. Carry out testing of functionality of the panel and devices post-installation.
Supply & Laying of cable 4 core 95 sqmm Armoured Aluminium cable (Make - Polycab / Havells / Gloster/RR/KEI/Finolex) on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables incl. finishing by dowells solderless socket as to GS as below :
3½ core 185 sq mm
3½ core 95 sq mm
3½ core 70 sqmm
3½ core 50 sqmm
4 core 35 sqmm
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Fabricating & installing of ladder type M.S cable trays incl. horizointal& vertical bends reducers,tees,cross members and other accessoriesas required and duly suspended from ceilling with M.S suspenders and incl painting with powder coating etc. as reqd. (300 mm width X 50mm depth x1.6mm thickness)
ELECTRICAL ASSOCIATES (BID ID -6851788)
SREEKRISHNA ENGINEERING ENTERPRISE (BID ID -6860573)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .