Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-AOC 23 6 C LAL VIHAR EAST END BAMRAULI PRAYAGRAJ 211012 U P | PRAYAGRAJ | UTTAR PRADESH | 211012 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹42.9 L+₹2.7 L (6.83%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹56.6 L+₹16.5 L (41.1%)Rejected-Finance 245A 7A 1 JAYANTIPUR GOKUL AVAS YOJANA SULEM SARAI ALLAHABAD PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹63.6 L+₹23.4 L (58.4%)Rejected-Finance HIG 40 TYPE B DEV PRAYAGAM ADA COLONY JHALWA PRAYAGRAJ U P 211015 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211015 | L4 | Rejected-Finance Being not lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) BAMRAULI
HQ CWE(AF) BAMRAULI PRAYAGRAJ 211012
PROVN OF WORK SERVICES FOR KU BAND AND SATCOM EQUIPMENT AT HQ CAC AT AF STN BAMRAULI
2023_MES_622899_6
87304/C/E8
Open Tender
Civil Works
Item Rate
182 days
BAMRAULI
MES Enlisted contractor of class D category b i
8 documents required · 8 mandatory
₹500
GE (AF) BAMRAULI
₹70,000
Yes
9 Oct 2024
11 Jul 2024
19 Sept 2024
11 Jul 2024
12 Sept 2024
25 Jul 2024
11 Jul 2024 - 18 Jul 2024
Amount
Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches , not exceeding 1.5 m wide and not exceeding 1.5 m in depth for founddation etc and getting out in soft/loose soil complete all as specified and as directed.
M&L cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concerete complete all as specified and as directed.
M&L reinforced cement concrete nominal mix 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation , rafts footings , plinth beam and similar other work complete all as specified and as directed.
Use and waste of form work to sides of concrete foundations,footing bases of columns rafts and rafts beam, rough finished surfaces flat complete all as specified and as directed.
M&L Mild steel TMT bar 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for column hooking end and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M&L Mild steel TMT bar 5mm dia and over upto and including 10 mm dia as in stirrups, cut to length bent to shape required including cranking bending spirally for hooping for column hooking end and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M&L reinforced cement concrete nominal mix 1:2:4 type B-1 using 20 mm graded stone aggregate as in columns, pillars, piers, post and struts etc complete all as specified and as directed.
Use and waste of form works to sides of pillar, strut, piers, columns and stanchions similar surface to concrete flat , rough finished surfaces of concrete complete all as specified and as directed.
Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance exceeding 250 m but not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed
M&L treating the backfill in contact with foundation at the rate of 7.5 litre of emulsion per square meter of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
M&L treating the top surface of filled earth @ 5 litres of emulsion per sqm for floor complete all as specified and as directed.
M&L treating the soil under plinth protection at the rate of 5 litres of emulsion per square meter of surface area complete all as specified and as directed.
M&L treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per meter of the perimeter wall complete all as specified and as directed.
M&L cement concrete 1:5:10 type E-2 using 40 mm graded stone aggregate as in foundation and mass concrete complete all as specified and as directed.
M&L for brickwork with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L reinforced cement concrete nominal mix 1:2:4 type B-1 using 20 mm graded stone aggregate as in beams, cantilever, bressummers, lintels over 1.50 m span and similar work complete all as specified and directed
M&L reinforced cement concrete nominal mix 1:2:4 type B-1 using 20mm graded aggregate in roof slabs supported walls, beam and columns in floors, roofs, landing,shelves etc complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floors or roof beam, beam haunching, girders, bressummers,lintels,cantilevers,shelves including supports,overhangs,etc also splays between floors and beams etc, rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formworks to soffits of suspended slab such as roof slabs,floor slabs,landing and similar works not exceeding 200 mm thick horizontal or sloping , rough finished surfaces of concrete complete all as specified and as directed.
M&l water proofing treatment to roof as per per manufacturer's instructions with the following specification:-. (a) 15 mm thick plastering in cement mortar 1:4 mixed with and including water proofing compound @3% by weight of cement including preperation of roof surfaces. (b) Applying evenly a coat of bitumineous primer @ 0.5 litre per Sqm (c) Applying evenly a coat of hot blow bitumen 85/25 grade @ 1.2 Kg per Sqm (d) Applying APP based polymeric membrane minimum 3 mm thick and minimum weighing 3kg/sqm laid on primed surface by LPG forced torch application with a side & end overlaps of minimum 100 mm. (e) Applying evenly a coat of hot blown bitumen 85/ 25 grade @ 1.2 Kg per Sqm over water proofing membrane (f) Applying a coat of bituminous based aluminium primer @ 100 gm/Sqm on top including sealing all joints by thermo fusion complete all as per manufacturer's instructions (g) Testing for water tightness by water ponding at least 72 hours
M&L 25 mm thick cement concrete1:2:4 type B-0using 12.5 mm graded stone aggregate as in levelling course, surface finished even and fair complete all as specified and as directed.
M&L 18-20 mm thick mirror polished machine cut kota stone slab flooring over and including 15mm thick cement screed bed in cement mortar 1:4 , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L 18-20 mm thick mirror polished machine cut kota stone slab as in risers of steps, skirting,dado and pillar laid over and including 10 mm thick rendering in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces of walls, surface finished even and fair complete all as specified and directed.
M&L 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surfaces of walls, surface finished even and fair complete all as specified and directed.
M&L 5 mm thick rendering in cement mortar 1:3 on ceiling , surface finished even and fair complete all as specified and directed
M&L applying three coats of white wash on ceiling including preparation of newly plastered surface of ceiling complete all as specified and as directed
M&L applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 1mm thick birla white wall care putty including preperation of plastered surfaces complete all as specified and as directed.
M&L applying two coats of cement base paint over one coat cement wash with white cement including preperation of plastered surface of wall complete all as specified and as directed.
M&L powder coated anodised aluminium doors (thickness of powder coating not less than 50 micron) sliding or hanging type with frame size 101.60mmX44.45mmX 2.00 mm thick and shutter aluminium anodised with top rail 47.62mmX 44.45mm X 1.50mm and style 47.5mm x 44.5 mmx1.5 mm , lock rail 83.50mmX 44.45mm X 1.50 mm and bottom rail150.00 mmX 44.50mm X 2.50 mm including necessary aluminium fittings like aluminium butt hinges 04 Nos , aluminium handles 150mm 02 Nos,aluminium tower bolts 200mm 01No, mortice lock 4 lever MS, hydraulic door closer of suitable capacity 01 No, aluminium door stopper 01 Nos, jointing cleats,glazing cleats,rubber packing , anodised aluminium snap beading, screws etc with panelling in two parts with 12mm thick MDF board with both side decorative lamination of approved texture in lower panel and 5mm thick tinted glass in upper panels including required all fittings and fixtures complete all as spesified and directed.
S&F premium sand textured finished mineral fibre acoustical ceiling tiles of size 600mmx600mmx16mm thick and placed on galvanised iron grid module consisting of wall angle section 24mmx24mm and tee section with web height of 38mm and flange 24mm and cross Tee 24mmx24mm size with suspension system complete all as per TD Drg No-CWE/BAM/TD-34 dated 29 Sep 2016 Note :- Ceiling tile shall be of Armstrong Brand "DUNE RH99" (Bevelled/Tegular) or equivalent make as approved.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavating in post holes ( or similar holes ) each not exc 0.5 cum , gettng out in hard/dense soil and removing the soil to a distance not exceeding 50 m complete all as specified and as directed.
M&L Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensil strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed.
M&L structrual steel work as in frame work of angle Iron as in vertical post fixed with cleat and connecting plate etc including necessary welding, drilling etc conforming to FE-410 W grade E-250 quality complete all as specified and as directed.
M&L structural steel work as in rolled mild steel angle iron framed work for roof trusses as in main and cross beams hip and jack rafter, purlin including distance pieces ,cleats or other connecting plates including necessary welding, drilling as required complete all as specified and as directed.
M&L broken stone hardcore of gauge not exceeding 63mm, deposited , spread and levelled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified and as directed.
M&L cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation filling and mass concrete to post holes or other similar works complete all as specified and as directed.
M&L applying two coats of synthetic enamel paint over one coat of red oxide primer including preparation of steel and iron surfaces over 10cm in width or girth,not otherwise described complete all as specified and as directed.
M&L cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, benching, bed block, cills, filling holes in wall like including weathering and slightly rounded or chamfered angle and throating as required including necessary use and waste form work. complete all specified and directed.
M&L applying three coats of white wash on wall including preparation of newly plastered surface of wall complete all as specified and as directed.
Excavating in post holes ( or similar holes ) each not exc 0.5 cum , gettng out in soft/loose soil and removing the soil to a distance not exceeding 50 m complete all as specified and as directed.
M&L cement concrete 1:3:6, type C-2 using 40 mm graded stone aggregate in foundation and mass concrete complete all as specified and as directed.
M&L mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wireetc,flat iron fillets for securing wire mesh etc including all necessary drilling, bolting or riveting, etc and other similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L mild steel work as in tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts confomiing to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L mild steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F mild steel screw bolts (machine made) 5 to 10 mm diameter of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm long complete all as specified and as directed.
Supply only 4 mm dia galvanised steel wire 50 mm X 50 mm mesh,chain link mild steel fencing complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standard, rails, straining bolts etc including provn of binding wire complete all as specified and as directed.
M&L applying two coats of black Japan paint over one coat of red oxide primer including preperation of steel and iron surfaces over 10cm in width or girth not otherwise described complete all as specified and as directed.
M&L reinforced cement concrete Design mix M-25 using 20 mm graded stone aggregate as in foundation , rafts footing,plinth beam, bases of column and other similar work complete all as specified and as directed.
M&L reinforced cement concrete Design mix M-25 using 20 mm graded stone aggregate as in columns, pillars, piers, post and struts etc complete all as specified and directed
M&L mild steel work as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M&L Granite(of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as directed.
M&L point wiring with single core FRLSH PVC sheathed multi stranded copper conductor of size 1.5 Sqmm drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia with GI saddles GI screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof ) including Tee, Junction boxes and provision of 3 mm thick plastic laminated sheet cover of suitable size ,mild steel terminal boxe with brass screws for mounting switchs, sockets,regulators etc including 1.5 Sqmm FRLSH PVC sheathed stranded copper conductor cable as continuous earth wire and connected to main earth dolly complete all as specified and directed for one light/Fan/exhaust fan point/ bell point controlled by one Switch.
Description same as per item No 57 above but for one 3 pin 5 Amps socket out let point on the same board with other switch complete all as specified and directed .
Description same as per item No 57above but for 3 pin 5 Amps socket out let on independent board complete all as specified and as directed .
Description same as per item No 57 above but for one power point 3/5 pin 15 Amps socket out let independent board using 2.5 Sqmm multi stranded FRLSH PVC insulated copper conductor cable with 2.5 Sqmm multi stranded FRLSH PVC insulated copper conductor cable as earth wire complete, all as specified and directed.
S&F 5 Amp switch piano, flush type , single pole one way complete, all as specified and directed .
S&F socket out let 2 in 1, 3 pin, 5 Amp flush type complete, all as specified and directed .
S&F 15 Amp switch piano, flush type,single pole one way complete, all as specified and directed .
S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and as directed .
S&F ceiling rose, 1 phase PVC or polycarbonate, isolated body complete all as specified and as directed .
S&F Factory made epoxy powder coated Vertical load line distribution boards (VTPN) 4 ways 415 Volt grade with double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall suitable for universal mounting and including 250 Amp copper bus bar netrual bar standard DIN rail, Earth bar and cable ties for cable manangement with top and bottom removable gland plates and knockouts complete all as specified and directed. Note:- MCB/MCCBs shall be measured and paid seperatly under respective item.
S&F MCCB 4 pole,415 V,40 Amp with breaking capacity 25 KA including connection and testing complete all as specified and directed ,
S&F MCB single pole, 6-32A ,10KA 'C' Series complete all as specified and as directed.
S&F submain wiring with four single core 6.0 sqmm FRLSH PVC insulated multistrand copper conductor cable drawn in and including concealed rigid non metallic PVC conduit dia not less than 20 mm , medium grade ISI marked with all fittings and fixing accessories and one single core 6.0 Sqmm FRLSH PVC insulated multistrand copper conductor cable as continuous earth wire complete all as specified and as directed. Note:- Four run of 6.0 sq mm copper cable,one run of PVC conduit and one run of 6.0 sq mm copper cable earth wire shall be measured as one unit.
M&L Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel ,filling adequate quantity of charcol dust and common salt all as shown in electrical plate No 3 of SSR Part-2009, connected to earthing with DBs all as specified including excavation and earth work in any type of soil, PCC 1:3:6 type C-1 using 20mm graded stone aggregate in chamber & cast iron earthing pit cover having size 250mmx250 mm, weight not less than 7.5 Kg as per relevant IS including frame, 15mm dia GI pipe light grade for earth lead protection, 20mm dia GI medium grade pipe for watering , water funnel etc complete all as specified and testing on completion.
S&F LED street light fitting 35 watt, 230 V, 6000k new generation energy saving and environmental friendly long life made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening seperate driver compartment with IP-66 protection and impact resistance of IK07 roadway luminaries with electronic driver including necessary connection with three core copper cable of suitable size of required length including mounting bracket made out of 40mm dia GI pipe light grade having length not less than 1 M with suitable size of mild steel clamp, nuts,bolts and washers etc complete all as specified and as directed. Make:- Crompton/ Philips/Bajaj/Havells as approved.
S&F 2 Zone Conventional Fire Alarm Control panel complying with BS EN 54/IS-15902-2011 Single loop panel of capacity 6 detector (ISI marked) complete all as specified and as directed.
S&F Detectors complying with multisensor detector with heat and smoke combination above false ceiling (ISI marked) complete all as specified and as directed.
S&F Detectors complying with multisensor detector with heat and smoke combination below false ceiling (ISI marked) complete all as specified and as directed.
S&F addressable intelligent fault isolator module (ISI marked) complete all as specified and as directed.
S&F manual call point break glass type with alarm LED (ISI marked) complete all as specified and as directed.
S&F Fire Alarm sounders / Sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 meter with sound output variation of + 5 DB for 1000 meter range (ISI marked) complete all as specified and as directed.
S&F Submain wiring with two run of 1.5 Sqmm FRLSH PVC insulated stranded copper conductor with one run of 1.5 Sqmm FRLSH PVC insulated, stranded copper conductor in and including mild steel conduit dia not less than 20 mm complete all as specified and as directed.
Supply, installation, commissioning and testing Inverter split type air conditioner of capacity 2.0 TR, 5 star rated invertor with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, star rated suitable for wall mounted, single phase, 230/250 Volt AC including cutting hole in existing wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar 1:2 after commissioning, making necessary connections, unplasticised 20 mm dia PVC pipe medium grade for draining out condensed water of required length as per site requirement including necessary connection with 2.5 Sqmm multistranded copper cable of suitable length,copper tube with insulation, fixing bracket and other accessories as required at site complete all as specified and directed. Make:-Carrier/Daikin/Voltas/Blue Star as approved. Note :- Installation and commissioning is to be carried out through OEM or authorised service centre / dealer.
S&F 5 KVA Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and as directed.
M&L for sub main wiring with two single core 4 Sqmm stranded copper conductor cable FRLSH PVC insulated and unsheathed drawn in including concealed PVC conduit dia not less than 25 mm with necessary fittings such as bend,tee , junction etc including 4 Sqmm FRLSH PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and as directed. Note:- Two run of 4 sq mm copper cable, one run of PVC conduit and one run of copper cable as earth wire shall be measured as one unit.
S& F single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps 230 V complete all as specified and as directed .
S&F AC controller for controlling four AC at a time consisting LCD display,metal body with wall mountings,temprature sensor,alarm system for any error,auto and manual facility for all AC complete all as specified and as directed.
Supply, laying ,jointing & testing 95 Sqmm cross sectional area , 3 core XLPE insulated , screened,PVC bedded, galvnised steel strip or wire armoured, electric power cable(heavy duty) with aluminum conductor, 11000 Volts Earthed conforming to IS-7098 Part -I 2011 with upto date amendment laid in trenches or through pipes or in ducts or on poles complete all as specified and as directed.
Supply, insatllation , testing and commissioning of step down transformer of capacity 100 KVA outdoor type complete with standard fitting accessories, HT 11 KV, 3 Phase 4 wire, LT 433 Volt, 3 Phase 4 wire with off load changer on primary side to carry secondary voltage + 7.5 % with tappings at every 2.5 % all as per latest IS 1180-2014 level 2 (ISI marked), copper wound oil cooling with fins vector Group: DYN 11, including initial oil filling complete all as specified and as directed including the following accessories:- (a) One cable box HT side consisting of 03 Nos porcelain with brass bushing rod complete with nuts and wahsers suitable for run of 03 core HT UG cable (b) one cable box LT side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT under ground cables (c) Oil conservator with filter type drain valve and oil level gauge (d) Dehydrating breather with first fill of dehydrating agent (e) Explosion vents (f) Thremometer pocket on tank cover (g) one number 100 mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centrigrade (h) Rating plate and terminal marking plate (j) Earthing arrangement (k) Oil drain filter valve (l) Oil drain valve (m) Lifting hook (n) Oil conservator with filling hole cap (o) Air release valve Plug (p) Four plate solid cast steel detachable rollers
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised earth strip 32mmx6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I - 2009, connected to earthing point of outdoor panel boards all as specified including excavation and earth work any type of soil, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for chamber and cast iron earthing pit cover having size 250mmx250mm, weight not less than 7.5 Kg as per relevant IS inclduing frame, 50mm dia GI pipe light grade for ptotection, 20mm dia GI medium grade pipe for watering , funnel etc complete all as specified and testing on completion.
S&F Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for cross sectional area 95 sqmm, 3 core XLPE armoured aluminium conductor cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 25 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 10 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for natural river sand as cushioning of cables including spreading and punning down complete all as specified and as directed. Note : Punned thickness shall be measured for payment purpose
Supply and laying old size bricks of size 230mmx115mmx75mm, designation 75 for cable protection complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover (ISI marked) class HV type 1,flat of size 300 mm x 180 mm x 40 mm complete all as specified and as directed.
S&F cable path indicator made of cast iron plate 150 mm dia ,6 mm thick rebated to spot welding with galvanised iron having 15 mm dia,450 mm long embedded in and including cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate of size 150mmx150mmx300mm below GL complete all as specified and as directed.
S&F Sheet metal chamber single door made of 3.15 mm thick sheet factory made of size 30cmx30cmx15 cm to be inside the existing wall with , 4 Nos copper bus bar 200 Amps mounted on insulator with incomming MCCB 100 Amp, 25 KA including all incomming and out going connections with lugs of required size including applying two coats of synthetic enamel paint over one coat of primer on exposed surfaces of steel and PCC 1:2:4 Type B-1 uding 20 mm graded stone aggregate as in fixing etc including testing complete all as specified and as directed.
Supply, installation,commissioning and testing 57 to 58.50 KVA Diesel Engine driven Generating set, static, silient (sound proof enclosure), water cooled, 415 volts ,AC, 3 phase, 4 wire system of supply, 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable for conditions prevalent at Bamrauli (capacity of engine, alternators shall worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height), anti-vibration pads complete all as specified and directed, including all feature to comply with latest CPCB-IV guidelines and comprising of followings accessories:-
(A) DIESEL ENGINE:- Diesel engine 1500 RPM, direct injection, 4 cylinder, four stroke, conforming to conforming to IS:100001/ISO3046/BS:649/BS:5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 58.5 KVA at outdoor atmospheric conditions at AF station Bamrauli ,taking all derating factor into consideration.The engine generally confirm to BS-5514, IS : 10002 : 1981 and including RECD device as per latest CPCB-IV norms for noise and emission limits and necessary certificate from NAL to the effect shall be submitted and complete of required fitting with the following accessories subject to the design of manufacturer :-
(i) Dynamically balanced fly wheel. (ii) Air cleaner oil bath type (iii) Electronic Governor class 1 A with back up Mechanical governor class 1A, flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level including RECD device as per CPCB-IV guideline (v) Radiator cooling (vi) Radiator fan with guard (vii) Vaccum indicator (viii) Fuel filter and fuel houses (ix) Fuel injection pump (FIP) (x) Fan and water pump assesembly (xi) Lub oil filter and pump
(xii) Electric starting system with battery charging alternator and axial type started motor including adequate number of high capacity maint free lead acid bty as per manufacturer recommendation including inter connecting cables/leads with terminals complete with starting/stopping switch voltmeter, etc 01 set (xiii) Engine safety shut down system against low oil pressure and high water pressure (xiv) Exhaust gas driven turbo charge (xv) Oil filter (xvi) Lub oil cooler (xvii) Engine main manual with spare part list (xviii) Suitable designed acoustic enclosure as per CPCB-IV regulations (xix) Any other item not included / specified but is a standard design of the manufacturer.
(B) ENGINE INSTRUMENT PANEL :- Engine instrument panel shall comprising of the following:- (i) Starting on /off switch. (ii) water temp auge. (iii) Hour meter cum RPM indicator (iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure. (viii) Any other item not included/specified but is a standard design of the manufacturer.
(C) ALTERNATOR:- Alternator shall be self excited, self regulated, brush less for rated capacity of DG Set continuous operation at the speed of 1500RPM at 415 volts, 50Hz three phase, 4 wire system with advance electronic voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible couping and conforming to IS-4722 complete-01 No. Note:- Alternator shall be able to deliver output rating at actual site condition. (D) MOUNTING ARRANGEMENT:-Common fabricated base frame for engine and alternator made from structural channel, jerk proof PCC 1:2:4 mix type B1 foundation including adequate number of suitable anti-vibration pads all as per manufacture recommendations is deemed to be included in the unit rate quoted by the contractor Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continous operation inside canopy with fuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per engineering practice complete all as specifided and directed.
Bypass arrangement by providing separate panel made out of 3mm thick CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R, Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 160 Amp is to be installed near AMF panel complete all as specified and directed. (i) Hour run meter. (ii) Any other item not included/ specified but is a standard design to the manufacturer. (E) AMF CONTROL PANEL:- Supply, fabricating and testing of factory mounted cubical automatic main failure panel with degree of protection IP-42 conforming to IS-2147, suitable for rated capacity of DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories:- (i) Master switch for auto/manual/reset/off-01 No. (ii) Ammeter digital type, 96X96 mm with CT's-03 Nos aux supply 230 vlts, AC, acuracyclass 1. (iii)Voltmeter digital type 96x96 mm to read 0-500 volts supply 230 volts, accuracy class 1.0. (iv) Digital frequency meter-01 No aux supply 230 volts, AC
(v) Push button start, stop, reset-01 No. (vi) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (vi) Battery charger connected to load. (vii) Transformer of adequate rating. (viii) Ractifiers (ix) DC ampere meter and voltmeter. (x) Fault accept / reset push button. (xi) Set of relays and contactor suitable for rated capacity of DG Set for automatic start and automatically shut down of suitable rating and capacity adjustable to 70 to 100% and 2 Nos MCCB 4 pole, 160 Amp, 25 KA fixed on main supply and DG set supply. (xii) Make of AMF control panel shall be as per OEM recommendations.
(F) Notes : (i) PCC foundation for DG Set and panel boards shall deemed to be included in unit rate quoted. PCC foundation of adequate/required size extending to 1.0 M all round more than the size of DG set, as per manufacturer design. (ii) DG set shall be tested as type test, routine test as per IS in the presence of GE and rep as decided by the Accepting Officer. (iii) The contractor shall submit QAP (Quality Assurance Programme) with in the 15 days from placement of order for DG set testing at factory premises. DG set shall be dispatched after inspection clearance by inspecting officer. (iv) The contractor shall get the approval of GE for the make of the DG set as they plan to procure. (v) Prior to manufacturing the general arrangement drawing Design details of the DG set shall be got approved by GE.
(G) Testing of DG Set (i) The DG set will be tested at manufacturer premises/factory in presence of authorized representative of Accepting officer. (ii) The DG set will be tested on load of unity power factor (PF=1) for the rated KW rating of the DG set. During testing the DG set will be run for a period of 12 hrs non-stop at full rated capacity on full load and one hr on 10% extra load above the rated capacity after 12 hrs of continuous run. (iii) The contractor has to arrange external load for the testing of DG sets at his own cost. The cost deemed to be included in the quoted amount. (iv) The contractor has to arrange POL/Diesel/Staff/Technician at his own cost for the testing. The cost deemed to be included in the quoted amount.
(a) High conductivity copper busbar having set of 4 strips, 4 Nos TPN of suitable for 200 Amps rating , Indicating lamp (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-200) Amps with CTs etc including rotary switch to measure load of each phase : L&T/Seimens (d) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase Make : L&T/AE (e) OFF load Change Over of capacity 200 Amp, 4 Pole, 415 volt: 01 Nos.
(f) INCOMMING: MCCB 4 Pole 200 Amp 415 volt thermal adjustable ,type with 36 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos g) OUTGOING: MCCB 4 Pole 100 Amp 415 volt thermal adjustable ,type with 25 KA breaking capacity & spreader both side as outgoing cotrol device : 02 Nos (h) MCCB 4 Pole 63 Amp 415 volt thermal adjustable ,type with 16 KA breaking capacity & spreader both side as outgoing control device : 01 No Note:-Contractor to submit the drawing of panel with name of manufacturer for prior approval of GE before placing of order for procurement.
M/S Krishna Electronic (BID ID -3085408)
R K CONSTRUCTION COMPANY (BID ID -3084172)
R.K.ASSOCIATES (BID ID -3084369)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .