| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | ₹32.6 L Quoted ₹33.7 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹40.2 LRejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | ₹40.2 L | L2 | Rejected-Finance Rejected being higher than L1 bidder. |
| 3 | L3₹40.4 LRejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 UDYAM WB 14 0036716 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | ₹40.4 L | L3 | Rejected-Finance Rejected being higher than L1 bidder. |
| 4 | L4₹40.5 LRejected-Finance | ₹40.5 L | L4 | Rejected-Finance Rejected being higher than L1 bidder. |
| 5 | L5₹40.5 LRejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | ₹40.5 L | L5 | Rejected-Finance Rejected being higher than L1 bidder. |
| Sl No | Description | Qty | Unit | UNIVERSAL TRADING CENTRE | UNIVERSAL TRADING CENTRE L6 | RADHA ENTERPRISE L3 | MS AP CONSTRUTION AND CO L7 | INDIA ELECTRICAL EQUIPMENTS L5 | SK CONSTRUCTION SYNDICATE & ENGG CO L8 | ARATI TRADING CO L2 | NIRMAL DAS AND CO. L4 | R T BUILDERS L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5 mtr wide and not excedding 1.5 mtr in depth for laying GI/CI pipes and gettings insoft /loose soil complete all as specified and directed.
Note :- Rate includes removing any type of tiles and PCC refixing after repair and making good as per existing. | 138.15 | Cum | 368 ₹50,839.20 | 368 ₹50,839.20 | 371 ₹51,253.65 | 373 ₹51,529.95 | 375 ₹51,806.25 | 381 ₹52,635.15 | 371 ₹51,253.65 | 364 ₹50,286.60 | 335 ₹46,280.25 |
| 2.00 | Returning filling including spreading levelling watering and wellramming inlayers not exceeding 25cm complete all as specified and directed. | 136.51 | Cum | 119 ₹16,244.69 | 119 ₹16,244.69 | 120 ₹16,381.20 | 124 ₹16,927.24 | 120 ₹16,381.20 | 122 ₹16,654.22 | 120 ₹16,381.20 | 118 ₹16,108.18 | 105 ₹14,333.55 |
| 3.00 | Removal of excavated soil to a distance not exc 50 metre away from starting point where directed at a level not exc 1.5m above the starting point complete all as specified and directed. | 1.64 | Cum | 240 ₹393.60 | 240 ₹393.60 | 239 ₹391.96 | 236 ₹387.04 | 240 ₹393.60 | 242 ₹396.88 | 239 ₹391.96 | 236 ₹387.04 | 235 ₹385.40 |
| 4.00Taking out existing pipe line of any type mentioned here-in-after from trenches, walls, floors etc for refixing or removal of unserviceable pipe from site all as directed. | ||||||||||||
| 5.00 | 150mm Bore | 62 | RM | 62 ₹3,844 | 62 ₹3,844 | 66 ₹4,092 | 70 ₹4,340 | 58 ₹3,596 | 63 ₹3,906 | 65 ₹4,030 | 65 ₹4,030 | 50 ₹3,100 |
| 6.00 | 100mm bore | 80 | RM | 44 ₹3,520 | 44 ₹3,520 | 48 ₹3,840 | 50 ₹4,000 | 48 ₹3,840 | 41 ₹3,280 | 45 ₹3,600 | 47 ₹3,760 | 35 ₹2,800 |
| 7.00 | 80mm bore | 94 | RM | 39 ₹3,666 | 39 ₹3,666 | 42 ₹3,948 | 41 ₹3,854 | 39 ₹3,666 | 44 ₹4,136 | 41 ₹3,854 | 34 ₹3,196 | 30 ₹2,820 |
| 8.00 | 50mm bore | 252 | RM | 38 ₹9,576 | 38 ₹9,576 | 41 ₹10,332 | 43 ₹10,836 | 41 ₹10,332 | 40 ₹10,080 | 39 ₹9,828 | 34 ₹8,568 | 29 ₹7,308 |
| 9.00 | 40mm bore | 172 | RM | 41 ₹7,052 | 41 ₹7,052 | 42 ₹7,224 | 49 ₹8,428 | 48 ₹8,256 | 45 ₹7,740 | 38 ₹6,536 | 44 ₹7,568 | 25 ₹4,300 |
| 10.00 | 25mm bore | 236 | RM | 36 ₹8,496 | 36 ₹8,496 | 39 ₹9,204 | 41 ₹9,676 | 39 ₹9,204 | 39 ₹9,204 | 35 ₹8,260 | 38 ₹8,968 | 22 ₹5,192 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
9 Jan 2026, 6:00 pmClosed
SHRI RAKESH KUMAR
GARRISON ENGINEER (CENTRAL) KOLKATA NAPIER ROAD HASTINGS 700022
REPAIR / REPLACEMENT TO EXTERNAL WATER SUPPLY WORK INCL REPAIR TO VALVE PITS AND CLEANING OF UG SUMPS, PUMP MOTORS AT BMC AREA UNDER GE (C) KOLKATA
2025_MES_745325_1
8894/E8
Open Tender
Miscellaneous Works
180 days
Kolkata
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(CENTRAL) KOLKATA
₹60,000
Yes
14 Mar 2026
19 Dec 2025
10 Jan 2026
19 Dec 2025
9 Jan 2026
3 Jan 2026
19 Dec 2025 - 2 Jan 2026
Excavation in trenches n.exc 1.5 mtr wide and not excedding 1.5 mtr in depth for laying GI/CI pipes and gettings insoft /loose soil complete all as specified and directed.
Returning filling including spreading levelling watering and wellramming inlayers not exceeding 25cm complete all as specified and directed.
Removal of excavated soil to a distance not exc 50 metre away from starting point where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Taking out existing pipe line of any type mentioned here-in-after from trenches, walls, floors etc including cleaning for refixing or removal of unserviceable pipe from site all as directed.
100mm bore
50mm bore
40mm bore
25mm bore
20mm bore
Supply & laying GI tubing medium grade galvanised with all fittings laid in trenches complete all as specifed and as directed for the size mentioned here-in-after:-
80mm bore
50mm bore
40mm bore
25mm bore
20mm bore
15mm bore
All as per item No. 13.00 but on floor/walls using necessary arrangement for scaffolding upto building of 12 storey height any type complete all :-
50mm bore
40mm bore
Each Job
Supply and Laying CI Pipe with flanged ends of size 150 mm bore centrifugually cast Class-A testing , commisioning complete all as specified and directed.
Supply and laying in trenches ductile iron pipe spigot and socketed (suitable for tyton joints gaskets) centrigugally cast class K-7, 100 mm bore including taking out unserviceable one complete all as specified and directed.
S&F gun metal gate valve screwed down high pressure with handle ironwheel (ISI marked) including taking down the unserviceable one all as specified and directed for the size mentioned here-in-after:-
Supply of bleaching powder of approved quality for cleaniang /washing the balanceing time, areation tower during descanning , refillling of fresh water in interval as directed by Engr-in-Charge for better cleaningness of valancing tank/areation tower are indicated places completed all as specified and directed.
Supply only Calcium based High strength Chlorination chemical contains chlorine contents not less than 65% with water in proportionate way for maintaining adequate chlorine at all time at Pump Houses as directed by competent authority for water Disinfection complete all as specifed & as Directed.
Supply and laying UPVC pipes of pressure rating 10 KGA per CM2 of dia 15 mm with all tube fittings (such as bend, elbows, tees, short pieces of medium grade, connectors, back nuts, caps , plugs and unions etc) laying in trenches/floor/ducts and also cutting pipes, screwing and for making bends on piping as required after taking down old pipe and complete all as specified and directed by Engr-in-charge.
Supply and laying UPVC pipes of pressure rating 10 KGA per CM2 of dia 20 mm with all tube fittings (such as bend, elbows, tees, short pieces of medium grade, connectors, back nuts, caps , plugs and unions etc) laying in trenches/floor/ducts and also cutting pipes, screwing and for making bends on piping as required after taking down old pipe and complete all as specified and directed by Engr-in-charge.
Supply and laying UPVC pipes of pressure rating 10 KGA per CM2 of dia 25 mm with all tube fittings (such as bend, elbows, tees, short pieces of medium grade, connectors, back nuts, caps , plugs and unions etc) laying in trenches/floor/ducts and also cutting pipes, screwing and for making bends on piping as required after taking down old pipe and complete all as specified and directed by Engr-in-charge.
Repairing the submersible pump 12.5/15 HP by cleaning, derusting, and replacement of minior spares i.e impealer key, neck ring, coupling bush and key,nuts bolts, washer etc. reassembling the pump after m/c work of servicable spares and replacment of new spare parts, testing and commissioning complete all as specified and directed by Engr-in-charge. (Notes :- (1) Replacement of major parts will be measured & paid separately; (2) Any minor part if required will be provided by contractor without any extra cost.
Supply only following spare parts for Pump and motor :-
Suction Bush
Stage Casing Bush
SS Shaft
SS Sleevs
Impeller
Sort piece with flange
Diffuser
Lifting and lowering of submersible pump and motor from bore well of any capacity upto depth of 50 metres including all T & P complete all as specified and directed by Engr-in-charge. Note:- One lifting and one lowering shall be measued as one job.
Material and Labour for rewinding of submersible motor upto 15 HP by taking out old/ burnt out winding from motor and cleaning the stator, rewinding with super enamelled water proof copper wire of original size/ gauge to produce required power, reassembling back including replacement of bush/bearing complete all as specified and directed.
Dismantling the channel base and taking out the pump & motor of capacity 75-100HP AC 3 phase 415 volt disconnecting the pump motor opening the pump, cleaning derusting thoroughly machining inside body of the pump & repairing by replacement collar rings gaskets, Impeller locknuts shaft key etc re-assembling the pump installtion & testing commissioning complete. (Notes :- (1) Replacement of major parts will be measured & paid separately; (2) Any minor part if required will be provided by contractor without any extra cost.
Supply and fixing only following spare parts for Pump and motor :-
( a) SS Shaft
(b) Impeller
(c) Impeller Bush
(d) Pump Bearing
(e) Motor Bearing
(f) Coupling of Pump motor
Supply and fix in repairs Fully automatic star delta controller with steel enlosure AC 3 phase, 415 volt 50 Hz, relay range 75-110 Amps coil volatge 380V suitable for 75-100 hp pump motor including dismantling the old unsv complete all as directed . Make:- L&T/Schneider / Siemens / ABB.
Supply and fix in repairs Fully aut
omatic star delta controller with steel enlosure AC 3 phase, 415 volt 50 Hz, relay range 6-16Amps coil volatge 380V suitable for 7.5-15 hp pump motor including dismantling the old unsv complete all as directed . Make:- L&T/Schneider / Siemens / ABB.
Supply and fix in repairs Fully automatic star delta controller with steel enlosure AC 3 phase, 415 volt 50 Hz, relay range 10-32 Amps coil volatge 380V suitable for 20-30 hp pump motor including dismantling the old unsv complete all as directed . Make:- L&T/Schneider / Siemens / ABB.
Supply and fixing only following spare parts for Pump and motor :-
Dismantling the channel base and taking out the pump & motor of capacity 5-12.5HP AC 3 phase 415 volt disconnecting the pump motor opening the pump, cleaning derusting thoroughly machining inside body of the pump & repairing by replacement collar rings gaskets, Impeller locknuts shaft key etc re-assembling the pump installtion & testing commissioning complete (Note : Major parts/spares of the pump will be measured & separately) (Notes :- (1) Replacement of major parts will be measured & paid separately; (2) Any minor part if required will be provided by contractor without any extra cost.
(a) SS Shaft
(b) SS Shaft Sleevs
(c) Impeller
(d) Impeller Bush
(e) Pump Bearing
(f) Motor Bearing
(g) Coupling of Pump motor
(h) delivery casing
Supply, installation and commissioning of mono block centrifugall pump set with base channel of capcaity 7.5kw/10HP , having suction discharge 65x50mm 415V 50Hz 2900RPM head range 42-72m , discharge 3.2-7.5lps with warranty of 12 months including necessary pcc work for fondation all as specified and directed.
Supply only following spare parts for Pump and motor :-
SS Shaft
Dismantling the channel base and taking out the pump & motor of capacity 22.5-30 HP AC 3 phase 415 volt disconnecting the pump motor opening the pump, cleaning derusting thoroughly machining inside body of the pump & repairing by replacement collar rings gaskets, Impeller locknuts shaft key etc re-assembling the pump installtion & testing commissioning complete (Note : Major parts/spares of the pump will be measured & separately) (Notes :- (1) Replacement of major parts will be measured & paid separately; (2) Any minor part if required will be provided by contractor without any extra cost.
Impeller
SS Shaft Sleevs
Impeller Bush
Pump Bearing
Motor Bearing
Coupling of Pump motor
Delivery casing
Supply and fix in repairs 3 pole contactor ML4, 45-70A capacity, 415 V ratings complete all as specified and as directed. Make:- L&T /Schneider / Siemens / ABB.
Supply and fix in repairs 3 pole contactor ML 3, 30-45A, capacity 360V complete all as specified and as directed.
Supply and fix in repairs 3 pole contactor ML 2, 20-32A, capacity 360V complete all as specified and as directed.
Supply and fix in repairs 3 pole contactor ML 1.5,10-16A, capacity 360V complete all as specified and as directed.
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
TENDER8894.pdf
Tender Documents • 1.40 MB
BOQ_834571.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid