Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 and Most reasonable | |
| 2 | L2₹4.8 L+₹7,260 (1.55%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹5.3 L+₹63,788 (13.6%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹5.6 L+₹90,515 (19.3%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L4 | Rejected-Finance Being Not L1 | |
| 5 | L5₹6.5 L+₹1.8 L (38.6%)Rejected-Finance | L5 | Rejected-Finance Being Not L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
6 Jul 2023, 6:00 pmClosed
AGE(I) DALHOUSIE PIN-176305
AGE(I) DALHOUSIE PIN-176305
REPAIR MAINTENANCE OF OLD US METER BOXES LIGHT POINTS INTERNAL WIRING SUBMAIN WIRING DBS INCL MISC WORKS AT JCOS AND ORS MD ACCN AT DALHOUSIE CANTT
2023_MES_601641_1
8941/2023-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I) DALHOUSIE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) DALHOUSIE
₹18,000
Yes
AGE(I) DALHOUSIE
12 Aug 2023
7 Jun 2023
8 Jul 2023
7 Jun 2023
6 Jul 2023
22 Jun 2023
7 Jun 2023 - 17 Jun 2023
17 Jun 2023
Amount
M & L for point wiring in replacement with copper conductor cable multistrand, PVC sheathed 1.5 Sqmm size FRLS for one light point controlled by one switch including one run of 1.5 Sqmm multistrand FRLS PVC sheathed copper conductor cable for earth continuity in and including PVC casing and capping of approved size,make and quality ISI marked, including providing suitable size of copper lugs and all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading 'Point wiring' fixed on walls/ceiling including sunk cast iron boxes concealing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover including taking down carefully existing old unserviceable copper/aluminium point wiring of any type (light/fan/socket or power) complete fixture and fittings such as switches ,ceiling rose, regulators,sockets etc all as specified and directed. Make of wire :- Havells / Polycab/ finolex / Plaza/Anchor/Grandlay
All as per item no. 1 but for one fan point, exhaust fan point.
All as per item no. 1 but for one bell point.
All as per Srl item No 2 here in before but for one 5 amps socket out let on same board.
All as per Srl item No 2 here in before but for one 5 amps socket out let on independent board,
All as per item No 2 above but for power point 3 pin switch socket 15 Amp with PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm FRLS on independent board including one run of 1.5 Sqmm multistrand FRLS PVC sheathed copper conductor cable for earth continuity in and including PVC casing and capping of appropriate size makes and best quality ISI marked, including CI/Pressed steel sunk box and providing suitable size of copper lugs and all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading "Point wiring" fixed on wall including sunk cast iron boxes concealing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed. Make of wire :- Havells / Polycab/ finolex / Plaza/Anchor/Grandlay
Supply & Fixing in replacement Switch piano, flush button, single pole one way 5 amps. Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing Bell push 6A flush type Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing in replacement Socket outlet 3 pin, 5 amps flush type. Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing in replacement Switch piano, flush button, 15 amps single pole one way.Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing in replacement Socket outlet 2 in 1,3 pin 5 and 15 amps flush type.Make :-Anchor/Cona/Plaza/SSK
Supply and fix in replacement ceiling rose 65X50 mm three terminals with back plate complete all as specified. Make :- Anchor / Cona / Plaza / SSK
S & F in replacement of unserviceable tube light fitting with wall mounted LED integrated batten fitting 20 W LED T-5, 4 feet, 6500K ,PVC extruded.Including supply and fixing square Box and all accessories complete all as specified and as directed by Engr-in- charge. Make:- Havells /Wipro /Crompton/Benlo
S & F in replacement of unserviceable tube light fitting with wall mounted LED integrated batten fitting 10 W LED T-5, 2 feet, 6500K ,PVC extruded.Including supply and fixing square Box and all accessories complete all as specified and as directed by Engr-in- charge.
S & F in replacement Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base. including 1 N x 9 W LED Lamp / 1 N x 7.5 W LED filament lamp Cat part of Havells Make LHFOAJE1TZ1I060 (Floretine WL 1LS B22 SS) or equivalent to Crompton /Bajaj / Wipro complete all as specified and as directed by Engr-in- charge.
Supply and fixing in replacement building security light 1x25 watt LED complete with tuff net glass protection IP 66, fixed to wall including with GI bracket made out of light grade 32 mm dia tubing up to 1.2 mtr lenth bend to shape with two sets of MS clamps made out of 25x3 mm flat iron with suitable nuts and bolts and testing complete all as specified and directed.
S & F Ding Dong AC. 230 volts,single pole al as specified and directed.
Supply & Fixing in in replacement sheet metal enclosure for DBs double door(When MCB,s to be used ) Tripple pole & neutral 4 way with 200 Amps rated Bus-Bar 415 volts with fixing arrangement complete all as directed by Engr-in-charge, Make:-C&S / Havells /Legrand /Indoasian/Standard/Benlo
Supply & Fixing in replacement Sheet metal enclosure for DB,s, double door (when MCB,s to be used) single pole & neutral 8 way with 200 amps rated bus bar 240 volts with fixing arrangements all as directed by Engr-in-charge,
Supply & Fixing in replacement MCB TPN 63 Amps 415 volts 10 KA complete with Fixing arrangement all as specified and as directed by Engr-in-charge,
Supply and fixing inreplacement MCB single pole and neutral 6 to 32 Amps, 240 volts complete all as specified and directed.
Supply and fixing inreplacement MCB single pole 6 to 32 Amps, 240 volts all as specified and directed.
M & L for Sub main wiring in replacement with two single core FRLS, PVC insulated and unshseathed copper wire multistrand of size 4 sqmm along with 4.0 sqmm single core FRLS, PVC insulated and unseathed copper wire as earth wire connecting to common earth including providing suitable size of Copper lugs for connections of cable with MCBs or bus bars and including PVC cancealed conduit of appropriate size and best quality ISI marked complete with removing of old U/S Sub main wiring all as specified and directed.Make of wire :- Havells / Polycab/ finolex / Plaza/Anchor/Grandlay
S&F in repair Moulded case circuit Breaker (MCCB) FP with fix thermal magnetic release capacity 100 Amps ,415 Volts 50 HZ 10 KA including making necessary connection with spreader, link and copper lugs including taking down old unserviceable MCCB/ main switch of any capacity and make complete all as specified and as directed. Make:- C&S / Havells /Legrand /Indoasian/Standard
Material and labour factory made sheet metal enclosure dust and vermin proof made out of 2.00mm thick Ms sheet of size 90x60x25 cm depth with double door hinged shutter and locking arrangement for fixing DBs,KWH meter etc flushed/semi flushed /grouting on wall as per site requirement including DIN rail channel for mounting of MCB,s SP/SPN. And provide in 4 rows TPN aluminium bus bar channel of rating 200 Amps duly mounted on 'F' class insulator with colour coded heat shrinkable sleeves and powder coated paint with suitable for one no for incoming of FP MCCB with internal connection of 16 sq mm multistrand copper wire with copper lugs from MCCB to Busbar etc. after prepration of surfaces with suitable glass vision panel complete all as directed (Note: Unit rate shall be inclusive of making good the area not exceeding 0.6 sqm and not exceeding 0.125m depth for filling the hollow existing surface with half bricks in CM (1:4) including taking down old unsv any type of sheet metal enclosure or main switch complete all as specified and as directed by Engr-in- charge.
M&L in replacement for Earthing complete with galvanised steel earth plate electrode 60 X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 5 of MES SSR Part I and testing on completion inclduing excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, with CI cover,funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs complete all as specified and directed with earth resistance not more than 1.0 OHMS. Note- In case earth resistance more than 1.0 ohms, the contractor wiil re earthing at no extra cost.
M/s Shakti Electric Works
M/S SHRI RAM BUILDERS
VIRAT CONSTRUCTIONS
M/S MALHI CONSTRUCTIONS
M/S NILESH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .