| 1 | L1₹12.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹14.6 L+₹2.0 L (15.9%)Rejected-Finance NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Other than lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
27 Oct 2022, 6:00 pmClosed
GE (AF) Utarlai
GE (AF) Utarlai PB No. 11 Barmer 344001
REPAIR TO GEYSERS, SOLAR WATER HEATING SYSTEM AT AF STN UTARLAI
2022_MES_555019_1
8338/E8
Open Tender
Civil Works
Item Rate
180 days
Utarlai
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹30,000
Yes
15 Dec 2022
29 Sept 2022
3 Nov 2022
30 Sept 2022
27 Oct 2022
13 Oct 2022
Amount
Disconnecting of electric connection and dismantling complete solar water heating system FPC/ETC type of capacity 500 ltrs per day installed at single/double/triple storey building including hot & cold water pipes and hot water tank complete and refixing after servicing/repairing the system fixing back in position and testing complete all as specified and directed by Engineer-in-charge. Note : Rates quoted by the contractor shall deemed to be included for :- (a) Replace the worn out nuts bolts, washers, union, sockets, flanges and screws etc. (b) Descaling/ desludging, cleaning and washing of the solar FPC panel/ ETC pipes, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and re-assembling the panel.
All as per items No. 1 here in before but of capacity 300 ltrs per day complete all as specified and directed by Engineer-in-charge.
All as per items No. 1 here in before but of capacity 200 ltrs per day complete all as specified and directed by Engineer-in-charge.
All as per items No. 1 here in before but of capacity 100 ltrs per day complete all as specified and directed by Engineer-in-charge.
S&F in repair gun metal float valve assembly of size 15mm for solar water heater system all as directed by Engr-in-Charge.
S&F in repair make up tank capacity 10 Ltr made out of stainless steel all as per existing sample & shape, including connection nipple for incoming and delivery as per existing complete for solar water heater all as specified and directed by Engr-in-Charge. Note:- Make up tank shall be ISI marked.
S & F in repairs of heating element suitable for solar water heating system of capacity 2 KW ISI marked as per existing shape all as directed by Engr-in-Charge.
S & F in repairs of heating element suitable for solar water heating system of capacity 3 KW ISI marked as per existing shape all as directed by Engr-in-Charge.
S & F in repairs of thermostat of capacity 0 to 80 degree suitable for upto 3 KW heating element of capacity all as directed by Engr-in-Charge.
Supply and fix as in replacement, solar panel toughened glass having thickness 3.2 mm all as per the existing model of system complete gasket made out of fine rubber to make system air tight, dust and water proof all as specified and directed by Engineer-in-charge.
S&F in repairs hot water storage tank of food grade stainless steel 100 ltrs capacity with heat exchanger having thermic fluid / Anti - freeze solution complete suitable ETC (Evacuated Tube Collector) solar water heating system including opening the outer body removing the glass wool, fixing the tank and filling the glass wool as before, re-installing the outer body, connecting the inlet and outlet connection, air vent, replacing the inlet/ outlet nipple complete all as specified and directed by Engineer-in-charge.
S&F in repairs hot water storage tank of food grade stainless steel 200 ltrs capacity with heat exchanger having thermic fluid / Anti - freeze solution complete suitable FPC (Flat Plate Collector) solar water heating system including opening the outer body removing the glass wool, fixing the tank and filling the glass wool as before, re-installing the outer body, connecting the inlet and outlet connection, air vent, replacing the inlet/ outlet nipple complete all as specified and directed by Engineer-in-charge.
S&F in repairs hot water storage tank of food grade stainless steel 500 ltrs capacity with heat exchanger having thermic fluid / Anti - freeze solution complete suitable FPC (Flat Plate Collector) solar water heating system including opening the outer body removing the glass wool, fixing the tank and filling the glass wool as before, re-installing the outer body, connecting the inlet and outlet connection, air vent, replacing the inlet/ outlet nipple complete all as specified and directed by Engineer-in-charge.
Supply and fix as in replacement, solar evacuated glass tube including water seal gasket (top and bottom) suitable for 100/200/300 Ltrs Solar water heater complete all as per existing size and shape as specified and directed by Engineer-in-charge.
S&F in repairs of rotational moulded polyethylene water storage tank 500 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position including fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line including dismantling old PVC storage tank, all as specified. Note:- PVC tank shall be ISI marked & having two layers.
S & F as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 2.5 Sqmm stranded copper conductor drawn in existing conduit with and including PVC FRLS insulated 2.5 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
S &F as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4.0 Sqmm stranded copper conductor drawn in existing conduit with and including PVC FRLS insulated 4.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4.0 Sqmm stranded copper conductor drawn in PVC conduit fixed on walls/ceilings with and including PVC FRLS insulated 4.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : PVC cables two single core, one single core of sizes and one RM of PVC conduit as mentioned will considered as one unit.
S & F as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 6.0 Sqmm stranded copper conductor drawn in PVC conduit fixed on walls/ceiling with and including PVC FRLS insulated 6.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : PVC cables two single core, one single core of sizes and one RM of PVC conduit as mentioned will considered as one unit.
S & F in repairs of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20mm dia.(minimum weight 20mm-210 grms)
S & F in repairs of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 15mm dia (minimum weight 15mm-142 grms)
Supply and fix, in repairs of Gun - metal globe or gate valve with iron wheel head, screwed both ends for iron pipes and for unions and fixing including taking down existing unserviceable valves complete all as specified and directed for the size 20mm dia
Supply and fix, in repairs of Gun - metal globe or gate valve with iron wheel head, screwed both ends for iron pipes and for unions and fixing including taking down existing unserviceable valves complete all as specified and directed for the size 15mm dia
Fabrication of stand for hot water storage tank /FPC (Flat Plate Collector) panel stand by using 60mmx60mmx6mm angle iron, bracings, supports, fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling old rusted stand all as directed by Engr-in-Charge
M &L for cement concrete PCC 1:2:4 type B1 (using 20 mm aggregrate) as coping and incliding form work complete all as specified and directed
Taking up or down steel water tubing and connections complete all as specified and directed for the size 20mm bore.
Taking up or down steel water tubing and connections complete all as specified and directed for the size 15mm bore.
Taking up or down steel water tubing and connections complete all as specified and directed for the size 25mm bore.
Supply and lay of GI pipe, "medium grade" ISI mark with all fittings laid in wallcomplete all as specified and as directed for the sizes 20mm bore
Supply and lay of GI pipe, "medium grade" ISI mark with all fittings laid in wallcomplete all as specified and as directed for the sizes 15mm bore
Supply and lay of GI pipe, "medium grade" ISI mark with all fittings laid in wallcomplete all as specified and as directed for the sizes 25mm bore
S&F in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 450 mm long complete all as specified.
S&F in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 600 mm long complete all as specified.
S&F in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 900 mm long complete all as specified.
Taking down geysers of any make & size from existing position of any height for repair, maintenance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced and shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts, indicator lamps, mounting bolt & nut etc shall be deemed to be included in the above item.
S&F in replacement heating element 2.0 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.
S&F in replacement heating element 1.5 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.
S&F in replacement thermostat (ISI marked) suitable for existing make of the geyser under repair of cap 50/25 Ltrs complete all as specified.
S&F in replacement geyser safety valve (pressure release valve) for the existing make & capacity of geyser complete all as specified.
M&L for painting of geyser of any cap 25/50 Ltr with 2 coats of synthetic enamelled paint after scraping the existing old painted surface complete all as directed.
S&F in replacement syphon assembly suitable for 25 ltr geyser
S&F in replacement syphon assembly suitable for 50 ltr geyser
S&F in replacement inner tank made up of stainless steel conforming to IS suitable for 25 ltrs geyser vertical type including rubber gasket complete all as specified and directed.
S&F in replacement inner tank made up of stainless steel conforming to IS suitable for 50 ltrs geyser vertical type including rubber gasket complete all as specified and directed.
S&F in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 25 ltrs geyser complete all as specified and directed.
S&F in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 50 ltrs geyser complete all as specified and directed.
S&F in replacement Glass wool filling in between inner tank and outer body of geyser of any make and type complete all as specified and directed.
S&F in replacement 3 core PVC insulated PVC sheathed flexible copper wire multistranded of size 2.5 sqmm complete all as specified and directed.
S&F in replacement plug top 3 pin, 15 Amp rating ISI Marked
M/S TANUSHREE CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .