Near Fort, MMC Office, Malegaon
Shifting of HT / LT Line network due to Proposed Road widening work at Old Aagra Road from Ansar Patra Depot To Owadi Nala along the Left side of road under USD I s/dn in 1.3 perc Shifting work.(PART I )
2021_MMC_743782_1
MMC/ELE/TEN-3/21-22
Open Tender
Electrical Works
Percentage
90 days
MMC Office
Please refer Tender documents.
8 documents required · 8 mandatory
₹6,124
₹40,000
13 Apr 2022
4 Dec 2021
27 Dec 2021
4 Dec 2021
25 Dec 2021
4 Dec 2021
Amount
Part A Shaifting of DTC 200 KVA: Supplying & erecting inline D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG (size 4 SqMtr.) with 4 Pole MCCB 300 Amps as incomer & 6 Nos. 100 Amps Kitkat for outing circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos.Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O.Fuse Set, L.A., A.B. Switch handle etc.Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with neccessary clamps, Nut-bolts. Vee cross arm, top clip, insulators etc. complete with caution board & barbed wire.D.P. Structure shall be erected in c.c. foundation complete. DSR / 8-4-20 / 21-22
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials. DSR / 9-1-4 / 21-22
Supplying and erecting G.l. stay set for poles,including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation. DSR / 8-7-2 / 21-22
Providing C.C. foundation including excavation for stay 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20x25mm.stone metal) with necessary curing and finishing in an approved manner. DSR / 16-3-6 / 21-22
Supplying & erecting single pole cut point channel set of for 11 kV HT OH line, two channel of size 100 x 50 x 6 mm 1.6 m long having stud angle of size 50 x 50 x 6 mm 1.5 m long with necessary clamps, nut bolts etc. complete. DSR / 8-4-17 / 21-22
A.B.Switch Fabrication set (M.S.Channel 75x40x6 mm) (as per MSEDCL estimate rate)
Supplying and erecting ACSR conductor of size -6/1-4.72 mm (Dog) complete. (394 kg/km) complete. (318.00 kg/km). DSR / 8-5-11 / 21-22
Supplying and erecting hard drawn G.I. wire 6 / 8 SWG complete erected for overhead line with -- etc. (As per MSEDCLs Rate)
PART - B Shifting HT line: Supplying and erecting Rolled steel Joist (Girder) pole 100 x 116 mm (23 kg/m) with provided base plate in provided foundation. DSR / 8-1-12 / 21-22 25 Nos. X 11 mtrs = 275 Mtrs. 12 Nos. X 10 mtrs = 120 Mtrs. TOTAL = 395 Mtrs.
Providing cement concrete foundation including excavation for the poles 60 cm x 60 cm x deep 1/6 of pole length in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered and with necessary curing and finishing in an approved manner. (for above 9 m poles) DSR / 16-3-4 /21-22
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials. DSR / 9-1-4 / 21-22
Supplying and erecting G.l. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.l. stay wire 7/10 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation. DSR / 8-7-1 / 21-22
Providing C.C. foundation including excavation for stay 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20x25mm.stone metal) with necessary curing and finishing in an approved manner. DSR / 16-3-6 / 21-22
Supplying and erecting ACSR conductor of size -6/1-4.72 mm (Dog) complete. (394 kg/km) complete. (318.00 kg/km). DSR / 8-5-11 / 21-22
Supplying and erecting porcelain pin type insulator suitable for 11kV line, complete. DSR / 8-6-9 / 21-22
Supplying pole bracket, for OH conductor fabricated from ISMC channel, 75x40x6.8 mm 1100mm long for 4 insulators and erecting on pole with 50x6 mm clamp as per approved method of construction and complete. DSR / 8-4-8 / 21-22
Supplying and erecting Vee cross arm for 11kV HTOH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220 mm bent at angle of 60 degree keeping base 305 mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts,washers complete. DSR / 8-4-12 / 21-22
Supplying and erecting 75x40 mm with 4.4 mm thick web and 7.3 mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065 mm for 11 kV,1320 mm for 22 kV between insulators for erection of top pin insulators complete. DSR / 8-4-14 / 21-22
Supplying and erecting enamel iron G.I. sheet 1.25mm (18 gauge) caution board of size 200 x 150 mm. as per I.S.2551 of 1982 in Marathi and Hindi erected at position. DSR / 6-1-17 / 21-22
Supplying and erecting porcelain disc type insulator suitable for 11kV line, complete. DSR / 8-6-6 / 21-22
Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials. (6.044 meters/kg.). DSR / 10-2-21 / 21-22
Supplying and erecting hard drawn G.I. wire 8 SWG complete erected for overhead line with proper size of G.I. wire for binding with jumpering etc. (As per MSEDCLs Rate)
Supplying & erecting single pole cut point channel set of for 11 kV HT OH line, two channel of size 100 x 50 x 6 mm 1.6 m long having stud angle of size 50 x 50 x 6 mm 1.5 m long with necessary clamps, nut bolts etc. complete. DSR / 8-4-17 / 21-22
PART - C Shifting of L.T. line: Supplying and erecting Rolled steel Joist (Girder) pole 125 x 70 mm (13.3 kg/m) with provided base plate in provided foundation. DSR / 8-1-13 / 21-22 09 mtr. X 30 nos. = 270 Mtrs.
Providing cement concrete foundation including excavation for the poles 60 cms. x 60 cms. x 1.5 mtr. deep in 1:3:6 cement concrete (20 x 25 mm.stone metal) and 45 cm x 45 cm x 45 cm /45 cm. dia. x 45 cm. height plinth duly plastered and with necessary curing and finishing in an approved manner. (for above 9 m poles) DSR / 16-3-4 / 21-22
Supplying and erecting MS pole bracket, fabricated from ISMC Channel 75x40x 6.8 mm and 550 mm long for vertical guarding for 2 insulators,complete. DSR / 8-4-3 / 21-22
Supplying and erecting MS pole bracket, fabricated from ISMC Channel 75x40x 6.8 mm and 1100 mm long for vertical guarding for 5 insulators,complete. DSR / 8-4-4 / 21-22
Supplying and erecting pole clamp made from 50 x 10 mm MS flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. DSR / 8-7-11 / 21-22
Supplying and erecting G.l. stay set for poles,including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation. DSR / 8-7-2 / 21-22
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials. DSR / 9-1-4 / 21-22
Providing C.C. foundation including excavation for stay 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20x25mm.stone metal) with necessary curing and finishing in an approved manner. DSR / 16-3-6 / 21-22
Supplying and erecting all aluminium stranded conductors 7/3.10 mm. complete. (Ant.) (145.0 kg/km) DSR / 8-5-5 / 21-22
Supplying and erecting hard drawn G.I. wire 10 SWG complete erected for overhead line with proper size of G.I. wire for binding with jumpering etc. (As per MSEDCLs Rate)
Supplying and erecting porcelain shackle type LT medium insulator 75x115 mm dia. with G.l.strips, nuts and bolts, complete. DSR / 8-6-2 / 21-22
PART - D Dismantling / Labour Charges: Erecting approved make 200 kVA,3 phase, 50 c/s Oil immersed and naturally cooled indoor / outdoor type,copper wound transformer with delta connected. on HV side & star connection on LV side with additional neutral brought out on load side, voltage rating 11/ 0.415 kV with--complete. DSR / 10-1-5 / 21-22
Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. DSR / 8-8-2 / 21-22
Dismantling the existing Distribution Transformer of any capacity from the plinth / foundation safely without any damages and storing in safe place. DSR / 10-3-1 / 21-22 06 Nos. X 200 KVA = 1200 KVA
Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. DSR / 8-8-3 / 21-22
Dismantling existing DO / AB switch set complete from D.P. structure in an approved manner. DSR / 10-3-3 / 21-22
Dismantling the existing W.T. fluorescent fitting/ S.V./ M.V/MH lamp fitting from pole with brackets complete. DSR / 2-14-3 / 21-22
Dismantling existing lightning arrestor set, insulator complete from DP structure in an approved manner. DSR / 8-8-4 / 21-22
Dismantling the existing cables of all types & size upto 10 sq mm. DSR / 7-12-1 / 21-22
Reconnection - 1 & 3 Phase. (As per MSEDCLs Rate)
Reconnection - 1 & 3 Phase. (As per MSEDCLs Rate)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .