| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.6 CrAccepted-Finance E 29 A ROAD NO 2 I P I AREA KOTA RAJASTHAN 324005 | KOTA | RAJASTHAN | 324005 | ₹1.6 Cr | 1 | Accepted-Finance Price quoted in their BoQ. |
| 2 | 2₹1.7 Cr+₹5.4 L (3.37%)Accepted-Finance 4 1309 NEW SIR SYED NAGAR ALIGARH ALIGARH UTTAR PRADESH 202002 | ALIGARH | UTTAR PRADESH | 202002 | ₹1.7 Cr+₹5.4 L (3.37%) | 2 | Accepted-Finance Price quoted in their BoQ. |
| 3 | Not Admitted-Fee/PreQual/Technical 403 404 DELPHI B WING HIRANANDANI BUSINESS PARK POWAI MUMBAI MAHARASHTRA 400076 | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | - | - | Not Admitted-Fee/PreQual/Technical Others-As per our RFP, you do not fulfil the mandatory criteria of experience of installing, monitoring, commissioning of minimum 6 air monitoring station in last 3 financial years. |
| Sl No | Description | Qty | Unit | Analyser Instrument Co. Pvt. Ltd. L1 | ENGINEERING AND ENVIRONMENTAL SOLUTIONS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.01 | CAAQM SYSTEM – HOUSING/ CONTAINER Housing /Container including sampling system (GAS and PM), internal, electrical and gas-line fitting, instrument racks, tools (electrical and mechanical etc.) RCC foundation (Monitoring Station Foundation), pillars miscellaneous works including Caging, civil & electrical work (for CAAQM stations) and beautification of the sites. | 1 | unit | 10,00,000 ₹10,00,000 | 8,00,000 ₹8,00,000 Lowest |
| 1.02 | CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER/ SYSTEM Sampling system for gas and PM | 1 | unit | 50,000 ₹50,000 Lowest | 2,00,000 ₹2,00,000 |
| 1.03 | CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER/ SYSTEM 19” Rack cabinet to accommodate all Analyzers & System | 3 | units | 15,000 ₹45,000 Lowest | 1,50,000 ₹4,50,000 |
| 1.04 | CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (PM) Automatic PM10 Particulate Matter Monitor pre-calibrated filter disc for particulate matter analyzer flow calibration. | 1 | unit | 10,00,000 ₹10,00,000 | 7,00,000 ₹7,00,000 Lowest |
| 1.05 | CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (PM) Automatic PM2.5 Particulate Monitor | 1 | unit | 10,00,000 ₹10,00,000 | 7,00,000 ₹7,00,000 Lowest |
| 1.06 | CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous Ambient Oxides of Nitrogen (NO-NO2- NOx) analyzers | 1 | unit | 9,00,000 ₹9,00,000 | 7,00,000 ₹7,00,000 Lowest |
| 1.07 | CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous Ambient Ammonia (NH3) Analyzer | 1 | unit | 4,50,000 ₹4,50,000 Lowest | 7,00,000 ₹7,00,000 |
| 1.08 | CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous Ambient Sulphur Dioxide (SO2) Analyzer | 1 | unit | 9,00,000 ₹9,00,000 | 7,00,000 ₹7,00,000 Lowest |
| 1.09 | CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous Ambient Carbon Monoxide (CO) Analyzer | 1 | unit | 9,00,000 ₹9,00,000 | 7,00,000 ₹7,00,000 Lowest |
| 1.10 | CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous Ambient Ozone (O3) analyzer | 1 | unit | 6,00,000 ₹6,00,000 Lowest | 8,00,000 ₹8,00,000 |
Tender Value
₹1.8 Cr
EMD Value
₹5.3 L
Closing Date
1 May 2025, 4:00 pmClosed
Regional Director LPCC UT of Ladakh
Regional Director LPCC UT of Ladakh Skara Yokma Near DIET and SIDCO office Leh
Supply, installation commissioning and operation and maintenance service of Continuous Ambient Air Quality Monitoring Station (CAAQMS)
2025_FEE_15840_2
e-Tender No 01 of RDLPCC of 2024-25
Open Tender
Civil Works - Others
Works
360 days
Leh
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
Regional Director LPCC UT of Ladakh
₹5.3 L
3 Sept 2025
17 Apr 2025
3 May 2025
17 Apr 2025
1 May 2025
17 Apr 2025
Amount
CAAQM SYSTEM – HOUSING/ CONTAINER Housing /Container including sampling system (GAS and PM), internal, electrical and gas-line fitting, instrument racks, tools (electrical and mechanical etc.) RCC foundation (Monitoring Station Foundation), pillars miscellaneous works including Caging, civil & electrical work (for CAAQM stations) and beautification of the sites.
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER/ SYSTEM Sampling system for gas and PM
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER/ SYSTEM 19” Rack cabinet to accommodate all Analyzers & System
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (PM) Automatic PM10 Particulate Matter Monitor pre-calibrated filter disc for particulate matter analyzer flow calibration.
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (PM) Automatic PM2.5 Particulate Monitor
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous Ambient Oxides of Nitrogen (NO-NO2- NOx) analyzers
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous Ambient Ammonia (NH3) Analyzer
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous Ambient Sulphur Dioxide (SO2) Analyzer
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous Ambient Carbon Monoxide (CO) Analyzer
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous Ambient Ozone (O3) analyzer
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Continuous BTEX Monitor/ Analyzer
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Multi calibration System for Gaseous monitor comprising of gas supply/generation and automated calibration with ozone generation system from Original Equipment Manufacturer (OEM)
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Calibration gas cylinders (NIST Traceable)
CONTINUOUS AMBIENT AIR QUALITY MONITORING ANALYSER (GAS) Sampling System having 10 port manifolds
METEOROLOGICAL SYSTEM Meteorological Sensors for Wind Direction, Wind speed, Ambient temperature, Relative humidity, Solar Radiation, and Rainfall, mounted on and telescopic Crank- up meteorological tower.
ONLINE UNINTERRUPTED POWER SUPPLY (UPS) UPS systems have a capacity of 10 kVA 3 phase I/P and single-phase O/P each for air conditioner/heater with 4 hrs back-up.
ONLINE UNINTERRUPTED POWER SUPPLY (UPS) Single phase input, single phase output 5 kVA UPS for analyzers with 4 hrs backup
SPLIT AIR CONDITIONERS 5-star rated 2 Ton capacity inverter AC with time change over feature and heater to maintain shelters inside temperature at 25°C with timer facility during cold season
SPLIT AIR CONDITIONERS Split Air Conditioners (1 Ton capacity) / heater for UPS room to maintain temperature 25°C
DATA ACQUISITION AND COMMUNICATION SYSTEM Local data acquisition system (DAS) with PC monitor with key board, mouse and black and white laser jet printer to fetch the data from Analyzer and transfer to LPCC HO and CPCB, Delhi.
DATA ACQUISITION AND COMMUNICATION SYSTEM Software should be capable of accepting remote calibration commands from CPCB and LPCC Head Office
DATA ACQUISITION AND COMMUNICATION SYSTEM Rack Server with rack 1 no with central acquisition software for data analysis to be installed at LPCC HO with 5kva UPS single phase input and single-phase output, (access point, Unified Threat Management Device (UTM) station and central 24-point COSCO switch and laser printer (Rack mountable) Note: Any accessories not mentioned above, if required, must be provided by the vendor.
DATA ACQUISITION AND COMMUNICATION SYSTEM Data Display Board with minimum 8mm pitch multicolor measuring 10ft x10ft, capable of running video messages in 4 languages. The structure is to be provided by the vendor.
DATA ACQUISITION AND COMMUNICATION SYSTEM Display Board Data transmission device station and HO
DATA ACQUISITION AND COMMUNICATION SYSTEM LED T.V. 16” with all accessories (Mouse, keyboard)
DATA ACQUISITION AND COMMUNICATION SYSTEM Ptz Camera compatible with data transmission system to display the status of LED Board at HO, UT Ladakh
DATA ACQUISITION AND COMMUNICATION SYSTEM Continuous Automatic Monitoring Station with Sampling Line, Internal fitting, Instrument racks, Electrical fittings and Gas line fittings, Tools (electrical and mechanical), and Data display system. The roof should be designed in such a way that snow slides off easily.
DATA ACQUISITION AND COMMUNICATION SYSTEM Internet and Broadband (for the station) and Data Card as mode Communication System (for display board) and any other advanced upgraded communication system and other incidental charges such as monthly bill of electricity and internet charges.
Fire extinguisher (Clean Agent)
Thermometer and hygrometer for measuring temperature (25±2°C) and humidity (45±5%) inside the station
Annual Operation & Maintenance of CAAQMS for five years (05)
ENGINEERING AND ENVIRONMENTAL SOLUTIONS PRIVATE LIMITED (BID ID -155683)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .