Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Techinical Documents OK |
| 2 | Accepted-Technical | Accepted-Technical Techinical Documents ok |
| 3 | Accepted-Technical | Accepted-Technical Techinical Documents OK |
Tender Value
₹14.3 L
EMD Value
₹14,256
Closing Date
23 Apr 2026, 5:00 pmClosed
EE RWS
RWS ZP KOLHAPUR
PROVIDING 100 KVA POLE MOUNTED DISTRIBUTION TRANSFORMER WITH H.T. OVERHEAD LINE FOR For 27 HP BUT UPTO 107 H.P. OR OTHER LOAD ABOVE 20 KW I H.P, 1 NO. 3 PHASE POWER SUPPLY TO PWW GUT NO 736 GP SAINIK TAKALI TAL -SHIROL
2025_KOLHA_1248446_2
37/2025-26
Open Tender
Electrical Works
Percentage
180 days
KOLHAPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
₹14,256
19 Jun 2026
9 Apr 2026
24 Apr 2026
9 Apr 2026
23 Apr 2026
9 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Sub Work No- PROVIDING 100 KVA POLE MOUNTED DISTRIBUTION TRANSFORMER WITH H.T. OVERHEAD LINE FOR For 27 HP BUT UPTO 107 H.P. OR OTHER LOAD ABOVE 20 KW I H.P, 1 NO. 3 PHASE POWER SUPPLY TO PWW GUT NO 736 GP SAINIK TAKALI TAL -SHIROL
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws , wall fasteners supports , nuts bolts etc. complete. (0.4572X0.6096 = 0.278 SQ.Mir plywood to fix OTC Mteter in CRCA sheet box Such 1 box So 0.278x1Nos.=0.278 sq.mtr.) | - | Each | - | - |
| - | Supplying and erecting iron work , sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting , drilling and welding complete erected at the position with necessary materials duly painted with one coat of red ox ide and two coats of enamel paint to match the switchgears or as per directions by the authority. For D.P structure of 25 KVA T/ F (1) Channel 100X 50X 5mm Weight 9.2 Kgs./mtr. 2 Nos for A.B switch, 2 Nos for T/ F base of length 2.8 Mtrs. Total length 2.8mtrs.x 4 Nos.=11.20mtrs. So 11.20mtrs.x 9.2Kgs.=103.04Kgs. (2) Channel 75x 40 weight 6.8Kgs/mtr. 1 No for D.O fuse and 1 No for L.A Total length 2.8Mtrs+2.8Mtrs.= 5.60Mtrs. So 5.60Mtrs.X 6.8Kgs.=38.08Kgs. (3) Angle 50x 50x 6mm. weight 4.5Kg/mtr. 2 Nos. for D.B, length 2.8Mtrs.2.8mtrs. x 2Nos.=5.60Mtrs. So 5.60Mtrs.x 4.5Kgs.= 25.20Kgs. (4) For T/ F belting , angle 50x50x 6mm, length 2.8Mtrs.=2 X 2.80Mtrs. weight 5.6Mtrs.x4.5Kgs.=25.20.!Sa..§. ..x(5) 14 SWG CRCA sheet for Dist. Box, 4.5 sq.mtrs. Weight 15.70Kgs./Sq.Mtr.So4.5sq.mtrs. x 15.70Kgs.=70.65Kgs. (6) On pole No.'O' channel 100x 50, length
1.6 Mtrs. @9.2Kgs/mtr. So weight 1.6mtr.x 9.2Kgs=14.72 Kgs.(7) stud angle 50x 50x 6 length 1.5mtrs.x 2Nos. i.e 3 mtrs. in length So weight 3mtrs. @4.5Kg/mtrs. 3mtrs.x 4.5Kgs.=13.50Kgs. 4 sq.mtrs.x 15.70Kgs.=62.80Kgs. Total Weight 103.04Kgs+38.08Kgs. +25.20Kgs.+25.20Kgs. +70.65 Kgs. +13.50Kgs+14.72Kgs.=290.39 Kgs. | - | kg | - | - |
| - | Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy , load survey , TOD , tamper detection & logging , power ON /OFF events , instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. | - | Each | - | - |
| - | Supplying , erecting & terminating FR XLPE insulated armoured (strip ) cable 1100 V 4 core 70 sq. mm. aluminium conductor complete erected with glands& lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | - | Mtr | - | - |
| - | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ ( (10Mtrs Hight 2 stud poles and 11 mtrs Hight 6 pole for H.T.line i.e. 10mtrs x2 Nos +11 mtrs x6 Nos =86 mtrs | - | Mtr | - | - |
| - | Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm , and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/vCA | - | Each | - | - |
| - | Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PLNCA | - | Each | - | - |
| - | Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 75x40x6mm. erected on pole complete as per specification no. OH-PLNCA | - | Each | - | - |
| - | Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. | - | Each | - | - |
| - | Supplying and erecting Inline D.P. Structure for 11/415 kV 63 KVA Transformer with R.S.J. Pole 2 Nos of size 100x116x11m long with suitable distribution box Of C.R.A. Sheet 16SWG with 4pole MCCB 100 A as incomer & 6 nos ,63amps Kitkat /MCCB for outgoing circuits Transformer D.P. Structure includes the A.B. switch 200amps ,D.O. fuse set L.A. set 2Nos of top channel of size 100 mmx50mm for erection of A.B. switch and 2 nos base channel of size 100x50mm for erecting Transformer channel of size 75x40mm for erecting D.O. fuse set L.A. ,A.B. switch handle etc Angle of size 50x50x6mm for erecting distribution box Transformer belts etc as per drawing (min124kg iron work ) with necessary clamps nut bolts Vee cross arms top clip insulators etc with caution bord and barbed wire D.P. Structure shall be erected in c.c. foundation complete as per specification no OH-PL/VCA | - | Each | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.43 MB
NIT.pdf
Tender Documents • 1.33 MB
BOQ_2223123.xls
BOQ • 0.31 MB
SBD.pdf
Other Document • 1.11 MB
Corrigendum_23042026.pdf
PDF • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .