SUPREINTENDING ENGINEER
ELECTRICITY DISTRIBUTION CIRCLE, MEERUT
11 KV LINE SHIFTING AND RELEASING 8 KW COMMERCIAL LOAD UNDER EDD I MEERUT
2022_PVVNL_737424_2
96/2022-23
Open Tender
Electrical Works
Lump-sum
60 days
WORKS
11 KV LINE SHIFTING AND RELEASING 8 KW COMMERCIAL LOAD UNDER EDD I MEERUT
2 documents required · 2 mandatory
₹1,180
SUPREINTENDING ENGINEER
₹1,000
Yes
7 Nov 2022
22 Oct 2022
4 Nov 2022
22 Oct 2022
4 Nov 2022
22 Oct 2022
Amount
iw.kZ tek ;kstuk esa Jh jkds'k dqekj iq= Jh jes'k pUn lkbZV ikapyh] ckxir jksM] esjB dh lkbZV ij fLFkr Mcy iksy ,oa IykV ds Åij ls xqtj jgh 11 dsoh ykbZu dks f'k¶V djuk%&
Cartage of following material from store center Meerut to JE Store including loading & unloading at both ends :-
PCC Pole 8.5 mtr. Long/ST Pole 11 Mtr. Long
Line material such as 11 KV Cross arms 11 KV pin, 11 KV pin insulator, 11 KV Disc, Stay rod, Stay wire ACSR weasel conductor, GI Wire, MS angle iron & MS Channel etc.
Cartage of following material from JE, Store to site of work including loading & unloading at both ends :-
PCC Pole 8.5 mtr. Long/ST Pole 11 Mtr. Long
Line material such as 11 KV Cross arms 11 KV pin, 11 KV pin insulator, 11 KV Disc, Stay rod, Stay wire ACSR weasel conductor, GI Wire, MS angle iron & MS Channel etc.
Erection of PCC Pole 8.5 mtr. Long/STP Pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of Soil including back filling of the pole with proper ramming after completion of work.
Fabrication and fixing of all 11 KV HT/LT Line
Making a section pole to exist pole jumpring of HT side and all 11 kv accessories
Erection of stay rod complete after digging a pit of size 1.20 x0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming.
Laying lifting stringing of proper sagging of ACSR weasal/rabbit conductor for 3 phase, 3 wire 33 KV line including binding & jumpering properly.
Dissmentling of Damaged & Broken PCC/ST pole/R.S. Joist by digging the pits & removel of complete HT/LT line accessories for double pole
Grouting of PCC/STP Pole as per respo
Dismentling of ACSR Conductor removal of complete HT/LT line accessories
providing and fixing stay clamps.
Providing and fixing Holding clamps.
Providing and fixing LT Clamps
Providing stay insulator
Providing and fixing bolts and nuts
Dismentling of 25 KVA T/F
Cartage of 25 KVA T/F site to JE store
Cartage of line material site to JE store
Cartage of RS Joist/Rail Pole site to JE store
Jh vfer ftUny iq= Jh egs'k ftUny lkbZV [kljk la[;k 83] xzke uaxyk tekyiqj ckxir jksM] esjB dks 08 fd0ok0 Hkkj dk okf.kT; la;kstu fuxZr djuk%&
Cartage of following material from store center Meerut to JE Store including loading & unloading at both ends :-
PCC Pole 8.5 mtr. Long/ST Pole 11 Mtr. Long
Line material such as 11 KV Cross arms 11 KV pin, 11 KV pin insulator, 11 KV Disc, Stay rod, Stay wire ACSR weasel conductor, GI Wire, MS angle iron & MS Channel etc.
25 KVA T/F including complete related material required for transformer
Cartage of following material from JE, Store to site of work including loading & unloading at both ends :-
PCC Pole 8.5 mtr. Long/ST Pole 11 Mtr. Long
Line material such as 11 KV Cross arms 11 KV pin, 11 KV pin insulator, 11 KV Disc, Stay rod, Stay wire ACSR weasel conductor, GI Wire, MS angle iron & MS Channel etc.
25 KVA T/F including complete related material required for transformer
Erection of PCC Pole 8.5 mtr. Long/STP Pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of Soil including back filling of the pole with proper ramming after completion of work.
Fabrication and fixing of all 11 KV HT/LT Line
Erection of Double pole on PCC/STP after digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of Soil for each pole including back filling of the pole with proper ramming after completion of work.
Fabrication and fixing of MS angle and MS channel, fixing all 11 kv accessories TPMO, Fuse set, 11 kv pin insulators as per double pole
Mounting of 25 KVA T/F with proper jumpring of HT side and fixing of cable on LT side of T/F
Making a section pole to exist pole jumpring of HT side and all 11 kv accessories
Erection of stay rod complete after digging a pit of size 1.20 x0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming.
Laying lifting stringing of proper sagging of ACSR weasal/rabbit conductor for 3 phase, 3 wire 33 KV line including binding & jumpering properly.
Earthingh of each 11 KV line & T/F properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GL wire.
Grouting of PCC/STP Pole as per respo
Cutting & chopping tree branches near side of line for making the clearance between line and tree
Providing and fixing Holding clamps.
Providing and fixing LT Clamps
Providing stay insulator
Providing and fixing bolts and nuts
SHASHI ENTERPRISES
Hi-tech power transmission
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .