GEMC-511687752337385
Awarded to SPI ENGINEERS PVT LTD
₹2.4 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| GWINSTEK SPECTRUM ANALYZER 9 kHz - 3 GHz, MODEL: GSP 9300B | GWINSTEK MODEL: GSP 9300B | - | 1 NOS | ₹2.4 L | 237,500 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.4 LQualified Make: GWINSTEK
Model: GWINSTEK MODEL: GSP 9300B 506 701 SIDDARTH BUILDING 96 NEHRU PLACE NEW DELHI 110019 | NEW DELHI | NEW DELHI | DELHI | 110019 | Make: GWINSTEK
Model: GWINSTEK MODEL: GSP 9300B | L1 | Qualified | |
| 2 | L2₹2.9 L+₹47,500 (20.0%)Qualified Make: RIGOL
Model: RIGOL DSA832 111 1ST FLOOR LAXMI DEEP TOWER LAXMI NAGAR DISTT CENTRE LAXMI NAGAR DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: RIGOL
Model: RIGOL DSA832 | L2 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
15 Oct 2018, 6:00 pmClosed
spectrum analyzers vector network analyzers Spectrum Analyzers Vector Network Analyzers ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Description of the itemuu Spectrum analyzers Spectrum analyzers
Two port vector network analyzers(with spectrum analyser) GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Markers Normal
delta * Trigger Free run
video
External * Display TFT Colour display * Interface USB
LAN * Software for transfer of screen shot/measurement data to PC Yes * SPECTRUM ANALYZER FEATURES Frequency Range 9 kHz to 3 GHz 9 kHz to 3 GHz Aging rate of spectrum analyzer frequency: Better than 1x10-6 Year Yes * 1/5 Frequency counter Resolution(minimum) (Hz) 1 * Frequency Span 100Hz to 3GHz 100Hz to 3GHz
1kHz to 3GHz Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz Yes * Spectral purity:Harmonics @ -40dBm level <=60 dBc yes * Sweep time @span >or= 1 KHz 2.5mS to 1000S * Sweep time @span = 0 Hz 10 micro S to 2000 S * Resolution Bandwidth (-3dB) 10 Hz to 3 MHz in steps * Video Bandwidth 10Hz to 1 MHz in steps * Amplitude : Max input level for protection (dBm) +30 * Amplitude : Max input level for measurement (dBm) 20 * Amplitude :level measurement uncertainity (dB) <=1 * Average noise level dis played(@300HzRBW
10 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Average noise level dis played(@100HzRBW
1 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Average noise level dis played(@300HzRBW
1 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Measurement features C/N ratio
AM%
time domain power measurement
channel power measurement
Phase noise measurement
TOI (THIRD ORDER INTERC EPT)
OBW(occupied bandwidth) * VECTOR NETWORK ANALYZER FEATURES Frequency Range for 2port vector network NA * 2/5 analyzer Frequency Resolution (CW ON) (Hz) NA * Return Loss (dB) NA * VSWR (dB) NA * Cable Loss (dB) NA * Calibration with Precision calibration components-open
short
load should be included to achieve directivity >35 dB NA * Abilty to locate Distance-to-fault in Co- axial cables NA * Phase Range (degree) NA * Phase Resolution (deg) NA * RF output port NA * Dynamic Range NA * Nominal port power output: Hi Power/Lo- Power selectable NA * Power levels corresponding to Hi and Lo levels - * Measurement of S11 and S21 and Smith Chart NA * Vector Voltmeter for comparision and verification of the phase of the phase- matched cables NA * Group Delay measurement - * OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C '5 to 40 degree C & 80% RH @ 40 degree C Operating Humidity 80% RH @ 40 degree C 80% RH @ 40 degree C POWER REQUIREMENT Power requirement 230 +- 10 VAC
50Hz 230 +- 10 VAC
50Hz
Rechargeable battery chemistry of the battery lithium ion * Voltage of rechargeable Battery 10.8 * capacity of rechargeable battery 5200 * 3/5 (millAh) Suitable charger adaptor provided Yes * WARRANTY Warranty 3 3.0 (or higher) ACCESSORIES Details of Standard accessories covered in the scope of supply - * GENERIC Other features - * CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest no * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest no * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH no * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vikash Siddhu 461111
Govt. Polytechnic College Itarsi
Sankheda Road
Near Canal
Itarsi
1 15 4/5 District Hoshangabad Madhya Pradesh
Pincode 461111
695311
GEM/2018/B/98380
GeM Contract
spectrum analyzers vector network analyzers
GeM Contract
Madhya Pradesh; Hoshangabad
PRODUCT
Awarded to SPI ENGINEERS PVT LTD
₹2.4 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| GWINSTEK SPECTRUM ANALYZER 9 kHz - 3 GHz, MODEL: GSP 9300B | GWINSTEK MODEL: GSP 9300B | - | 1 NOS | ₹2.4 L | 237,500 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| spectrum analyzers vector network analyzers Spectrum Analyzers Vector Network Analyzers ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Description of the itemuu Spectrum analyzers Spectrum analyzers | - | - | - |
| Two port vector network analyzers(with spectrum analyser) GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Markers Normal | - | - | - |
| delta * Trigger Free run | - | - | - |
| video | - | - | - |
| External * Display TFT Colour display * Interface USB | - | - | - |
| LAN * Software for transfer of screen shot/measurement data to PC Yes * SPECTRUM ANALYZER FEATURES Frequency Range 9 kHz to 3 GHz 9 kHz to 3 GHz Aging rate of spectrum analyzer frequency: Better than 1x10-6 Year Yes * 1/5 Frequency counter Resolution(minimum) (Hz) 1 * Frequency Span 100Hz to 3GHz 100Hz to 3GHz | - | - | - |
| 1kHz to 3GHz Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz Yes * Spectral purity:Harmonics @ -40dBm level <=60 dBc yes * Sweep time @span >or= 1 KHz 2.5mS to 1000S * Sweep time @span = 0 Hz 10 micro S to 2000 S * Resolution Bandwidth (-3dB) 10 Hz to 3 MHz in steps * Video Bandwidth 10Hz to 1 MHz in steps * Amplitude : Max input level for protection (dBm) +30 * Amplitude : Max input level for measurement (dBm) 20 * Amplitude :level measurement uncertainity (dB) <=1 * Average noise level dis played(@300HzRBW | - | - | - |
| 10 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Average noise level dis played(@100HzRBW | - | - | - |
| 1 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Average noise level dis played(@300HzRBW | - | - | - |
| 1 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Measurement features C/N ratio | - | - | - |
| AM% | - | - | - |
| time domain power measurement | - | - | - |
| channel power measurement | - | - | - |
| Phase noise measurement | - | - | - |
| TOI (THIRD ORDER INTERC EPT) | - | - | - |
| OBW(occupied bandwidth) * VECTOR NETWORK ANALYZER FEATURES Frequency Range for 2port vector network NA * 2/5 analyzer Frequency Resolution (CW ON) (Hz) NA * Return Loss (dB) NA * VSWR (dB) NA * Cable Loss (dB) NA * Calibration with Precision calibration components-open | - | - | - |
| short | - | - | - |
| load should be included to achieve directivity >35 dB NA * Abilty to locate Distance-to-fault in Co- axial cables NA * Phase Range (degree) NA * Phase Resolution (deg) NA * RF output port NA * Dynamic Range NA * Nominal port power output: Hi Power/Lo- Power selectable NA * Power levels corresponding to Hi and Lo levels - * Measurement of S11 and S21 and Smith Chart NA * Vector Voltmeter for comparision and verification of the phase of the phase- matched cables NA * Group Delay measurement - * OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C '5 to 40 degree C & 80% RH @ 40 degree C Operating Humidity 80% RH @ 40 degree C 80% RH @ 40 degree C POWER REQUIREMENT Power requirement 230 +- 10 VAC | - | - | - |
| 50Hz 230 +- 10 VAC | - | - | - |
| 50Hz | - | - | - |
| Rechargeable battery chemistry of the battery lithium ion * Voltage of rechargeable Battery 10.8 * capacity of rechargeable battery 5200 * 3/5 (millAh) Suitable charger adaptor provided Yes * WARRANTY Warranty 3 3.0 (or higher) ACCESSORIES Details of Standard accessories covered in the scope of supply - * GENERIC Other features - * CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest no * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest no * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH no * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vikash Siddhu 461111 | - | - | - |
| Govt. Polytechnic College Itarsi | - | - | - |
| Sankheda Road | - | - | - |
| Near Canal | - | - | - |
| Itarsi | - | - | - |
| 1 15 4/5 District Hoshangabad Madhya Pradesh | - | - | - |
| Pincode 461111 | - | - | - |
Exempted
6 Nov 2018
4 Oct 2018
contract_GEMC-511687752337385.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_695311.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .