Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹28.1 L+₹68,718.50 (2.51%)Rejected-Finance 51 HANUMAN COLONY GALI NO 4 CHAK 5 E CHHOTI SRI GANGANAGAR RAJ | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹29.3 L+₹1.9 L (6.88%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹30.1 L+₹2.7 L (10.0%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
13 Nov 2020, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
PROVN OF 06 X BATHROOMS INCLUDING WC WITH WATER CONNECTION SEWAGE LINE AND SPECIAL REPAIR TO JCOs MD ACCN WITH CERTAIN RW AT LGJ MIL STN
2020_MES_386317_1
8931-34/20-21
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
Class D Cat (a)(i)(a)(ii) (b)(i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹54,000
Yes
13 Jan 2021
14 Oct 2020
16 Nov 2020
14 Oct 2020
13 Nov 2020
29 Oct 2020
Amount
B/R Portion : Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) complete all as specified and directed by Engr-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificlly provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engr-in-charge.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engr-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed by Engr-in-charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engr-in-charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engr-in-charge.
M&L for glazed ceramic coloured tiles of size 350 X 250 X 7 mm / 450 x 350 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engr-in-charge.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-charge.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and directed by Engr-in-charge.
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and directed by Engr-in-charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engr-in-charge.
M&L for 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub-base complete all as specified and directed by Engr-in-charge.
M&L for 100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in kerb stones size 300mm x 300mm x 100mm with plain fair faces, including chamfers, weathering, throating etc setting in CM 1:4 complete all as specified and directed by Engr-in-charge.
M&L Machined pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-40 grade over 50mm thick Fazilka sand cushion complete all as specified and directed by Engr-in-charge.
Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-charge
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200 mm thick (horizontal or sloping) rough finish surface of concrete flat all as specified and directed.
M&L for reinforced cement concrete M20 grade (1:1.5:3) type A-1 using 20mm graded stone aggregrate in Chajjas complete all as specified and directed by Engr-in-charge. Note : Reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete M20 (1:1.5:3) type A-1 using 20mm graded stone aggregrate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like; all as specified and directed. Note : Reinforcement shall be measured and paid seperately.
S&F mild steel TMT bars (Fe500D) 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip complete all as specified and directed by Engr-in-charge.
S&F mild steel TMT bars (Fe500D) 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip complete all as specified and directed by Engr-in-charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for rendering, 10 mm thick on brick work or concrete surfaces in cement mortar 1:4 on ceiling finished even and fair complete all as specified and directed by Engr-in-charge.
M&L for rendering, 5 mm thick on brick work or concrete surfaces in cement mortar 1:4 on ceiling finished even and smooth without using extra cement all as sepecified and directed.
M&L for two coats of oil bound distemper on newly plastered surfaces of walls paint over 3mm thick wall care putty including preparation of surfaces complete all as specified and directed by Engr-in-charge.
M&L for complete removal of existing treatment and two coats of oil bound distemper over 3 mm thick wall care putty on plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engr-in-charge.
M&L for 3 coats of white wash on newly / old plastered surfaces incl preparation etc. on wall complete all as specified and directed by Engr-in-charge.
M&L for 3 coats of white wash on newly / old plastered surfaces incl preparation etc. on ceiling complete all as specified and directed by Engr-in-charge..
M&L for two coats of cement base paint on newly / old plastered surfaces incl preparation etc. on wall complete all as specified and directed by Engr-in-charge.
M&L for broken brick boulder hard core of gauge, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed by Engr-in-charge.
M&L continous brick edging with fly ash bricks old size bricks, with width equal to the width of the brick; liad dry on end vertically complete all as specified and directed by Engr-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. and getting out hard/dense soil complete all as specified and directed by Engr-in-charge.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth and n exc 10 SQM on plan and getting out in soft / loose soil complete all as specified and directed by Engr-in-charge.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation, filling & mass concretecomplete all as specified and directed by Engr-in-charge.
M&L for brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engr-in-charge.
M&L for brick work with fly ash bricks, old size bricks straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed by Engr-in-charge.
M&L for PCC 1:2:4 type B2 using 40mm graded aggregates as in benching / haunchig of manholes including forming channels including necessary formwork etc. complete all as specified and directed by Engr-in-charge.
M&L for PCC 1:2:4 type B1 using 20mm graded aggregates as in coping and the like including weathering slightly rounded or chamfered angles and throating, as directed including necessary formwork etc. complete all as specified and directed by Engr-in-charge.
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engr-in-charge.
M&L for PCC 1:2:4 type B2 using 40mm graded stone aggregate in foundation, filling & mass concrete all as specified and directed.
M&L Rendering 10mm thick on fair face of brick work in cement mortar 1:4 and finished surfaces even and smooth with using extra cement as specified including WPC complete all as specified and directed by Engr-in-charge. Note : - (WPC shall be measured and paid seperately)
M&L moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engr-in-charge.
Supply and laying DWCPE (SN8) drain pipes 150mm inner dia as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all assessories / fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge. Make :- Rex Polyextrusion Limited/ Dura line / Alom Poly Extrusions Ltd / Jain Irrigation
Supply and laying DWCPE (SN8) drain pipes 180mm(OD)/163mm(ID) as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all assessories / fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge. Make :- Rex Polyextrusion Limited/ Dura line / Alom Poly Extrusions Ltd / Jain Irrigation
Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm any type of soil allcomplete all as specified and directed by Engr-in-charge.
Removing excavated material n.exc 50m and depositing where direcrted at a level n.exc 1.50 m above the starting point complete all as specified and directed by Engr-in-charge.
Removing excavated materials exc 250 mtr but not exc 500 mtr and depositing where directed complete all as specified and directed by Engr-in-charge.
Cutting into existing manholes for connection of new drain making pipes and rendering cutting out existing benching & forming branch channel in PCC 1:2:4 type B1 smooth finished & forming benches as reqd etc for 150 mm bore complete all as specified and directed by Engr-in-charge.
M&L preparation of new steel surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer all as specified.
Dismantling of brick tiles in floor laid dry and pointed in cement morter complete all as specified and as directed by engineer-in-Charge.
Demolition mud in roofs, any thickness, including plastering and leeping complete all as specified and directed by Engr-in-charge.
M&L applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm as in roof including cleaning surfaces all as specified and directed by Engr in charge.
M & L APP based membrance minimum weighing 3 KG per sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than150 gms/sqm) laid on primed surface by torced application with APP membrane covered with 40mm thick brick tiles (manufactured with canal water) over and including 10mm thick screed bed in CM 1:4 complete all as specified & directed by Engineer-in-charge. Note : Brick tiles shall be measured & paid separately under respective item of this BOQ
M&L preparation of new bituminious of any description not otherwise described over 10 cm width or girth and apply two coats of aluminium paint all as specified.
M&L PCC (1:7:12) using 40mm graded stone aggregate as filling of sunken floors/bottom and side of drain complete all as specified & directed by Engr-in-charge.
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 and finished fair and even including mixing of WPC in mortar complete all as directed by Engr-in-charge. Note : - (WPC shall be measured and paid seperately)
Supply only integrated water proofing compound complete all as directed by Engr-in-charge. Make:- Dr Fixit/Fosroc/BASF/STP
Material and labour for creating fillet caving 50x50mm with polymer modified mortar on the junction of slab and wall as per manufacture instructions, Material and labour Providing for applying two coats of two component (1 part Liquid: 2 part Powder) ready to use cementitious waterproof coating on properly prepared surface by brush having elongation of >50% for the applying water proofing treatment as per following and complete all as directed by the EIC. (i) Applying 1st coat of two components modified polymer coating on horizontal and verticle surfaces. (ii) Provn of glasses fiber mess of 2x2mm immediately on alone coating. (iii) Applying 2nd coat of two components modified polymer coating after 72hrs on horizontal and verticle surfaces. NOTE:- Complete treatment to be carried out by authorised applicatior of waterproofing manufacture. Make : Dr Fixit/Fosroc/BASF/STP
Taking down chowkhats or frames n.exc 1.5 sq. m each with shutters (without taking off shutters from the frame) complete all as specified & directed by Engr-in-Charge.
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame)complete all as specified & directed by Engr-in-Charge.
Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each complete all as specified & directed by Engr-in-Charge.
S&F framed work as in chowkats of doors windows of angle iron ,gates or other section with gusset plates, rails, braces etc conforming to Gde Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S&F hold fast of flat iron 25 x 3 mm conforming to Fe-290 or Fe 330 including preparing the surfaces & treated with two coats for coaltar & sanded with clean sharp sand complete all as specified & directed by Engr-in-Charge.
Supply & fixing, factory made steel windows all as per IS 1038/83, with side hung shutters including box type hinges, MS handle, peg stay, 02 Nos MS tower bolt 100mm long for each leaf complete with glazing bars dovetailed or welded, including cutting holes in brick wall, fixing in PCC (1:2:4 type B-1 and making good complete all as specified & directed by Engineer-in-Charge.
Supply & fixing, factory made steel windows all as per IS 1038/83, with side hung shutters including box type hinges, MS handle, peg stay, 02 Nos MS tower bolt 100mm long for each leaf complete without glazing bars dovetailed or welded, including cutting holes in brick wall, fixing in PCC (1:2:4 type B-1 and making good complete all as specified & directed by Engineer-in-Charge.
Supply & fixing, factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, steel peg stay, fixing lugs in PCC (1:2:4) type B-1 and making good complete all as specified & directed by Engineer-in- charge.
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates.
M&L for Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc.conforming Fe 410-W (Gde E-250) quality A all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for Cement concrete 1:3:6 type C–1 (using 20mm graded crushed stone aggregate) as in coping, hold fast, bed blocks or similar block etc complete all as specified and directed by Engineer - in - Charge.
Supply and fixing of Fibre glass Reinforced plastic (FRP) door frame of required built in colour in three legged of cross-section 90mm x 45mm having single ribate of 32mm x 15mm to recieve shutter of 30mm thick including laminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood in all three legs frame shall be covered with fibreglass from all sides MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specified and as directed by Engineer-in- charge.
Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) paneled doorshutter conferming to IS:14856-2000 of required colour and made with fire retardant grade unsaturated polyster resin,moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings,cast molithically with 5mm thick FRP laminated for panels including fixing to frames, complete all as specified and as directed by Engineer-in- charge.
S&F Fibre glass reinforced translucent (Polycarbonate sheet) fixed having thickness 2mm with coach screws and washer in roof,wall etc complete all as specified and as directed by Engineer-in- charge.
S&F 100 mm long butt hinge, extruded aluminium alloy with galvanised mild steel hinge pin, anosied and fixed type B-21 complete all as specified & directed by Engr-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections complete all as specified & directed by Engr-in-Charge.
S&F 150 mm long aluminium anodised handle, cast type complete all as specified & directed by Engr-in-Charge.
Taking down existing shutter and refixing in same opening shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each complete all as specified & directed by Engr-in-Charge. (Note:- 'Refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.)
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as directed.
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) all as directed.
S&F flush shutter 25mm thick solid core construction with block board core and plywood face panels; commercial type on both sides as cupboard and kitchen shutters complete all as specified & directed by Engineer-in- charge.
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel complete all as specified & directed by Engr-in-Charge.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed by Engr-in-Charge.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt type not less than 16mm dia fixed complete all as specified & directed by Engr-in-Charge.
S&F as 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed by Engr-in-Charge.
M&L Block board, 19/20mm thick, grade 1 quality, exterior grade, decorative type with decorative face veneer on both face, fixed with screws to timber frame work complete all as specified & directed by Engr-in-Charge.
M&L plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc 3 & n.exc 6 Sq.cm of 2nd class hard wood complete all as specified & directed by Engr-in-Charge.
S&F continous (piano) hinges, mild steel, bright finish or electrogalvanised (width of flaps 30mm ) acomplete all as specified & directed by Engr-in-Charge.
S&F 125mm hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified & directed by Engr-in-Charge.
S&F 125 mm long aluminium anodised handle, cast type complete all as specified & directed by Engr-in-Charge.
S&F stainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified & directed by Engr-in-Charge.
,--ditto-- all as per item No 93 above but fixed in repairs complete all as specified & directed by Engr-in-Charge..
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified & directed by Engineer-in- charge.
S&F 4mm thick figured glass pin head type and glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified & directed by Engineer-in- charge.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified & directed by Engr-in-Charge.
M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer all as specified.
M&L preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint all as specified.
S&F drapery rods, coloured, standrad quality, powder coated not less than 25mm dia with heads at both ends and middle support, rings, etc. complete all as specified & directed by Engr-in-Charge.
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified & directed by Engr-in-Charge.
S&F in repair brass hat pegs, solid body, 125 mm to 175 mm (4 legs) complete all as specified & directed by Engr-in-Charge.
S&F in repair towel rails 20mm dia 600mm long brass chromium plated superior quality brass chromium plated fancy type complete all as specified & directed by Engr-in-Charge.
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified & directed by Engr-in-Charge.
S&F soap dish vitreous china white, approximate size 160 x 160 x 90mm fixed to plugs with chromium plated brass screw complete all as specified & directed by Engr-in-Charge.
S&F in repairs vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot rests (excl flushing cistern) but including CI 'P' trap set in and including concrete fixed complete all as specified & directed by Engr-in-Charge.
S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe and connection to pipe and flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern complete all as specified & directed by Engr-in-Charge.
S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including conncetion to flushing pipe and waste pipe providing and fixing plugs bedding urinal against wall all as specified .
S&F in repair vitreous china wash hand basin coloured Flat back of size 550x400mm, long screwed shank fly nut flange end including cutting for and pinning in ends of brackets in 1:3 CM including 32mm dia chromium plated waste coupling/trap complete all as specified & directed by Engr-in-Charge.
S&F pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified & directed by Engr-in-Charge. Note : Minimum Wt should not be less than 450 gms
S&F in repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, hand operated, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engr-in-Charge.
S&F Self-closing flush taps for urinal, cast copper alloy, chromium plated, screwed for iron pipe and fixed 15mm bore pipe complete all as specified & directed by Engr-in-Charge.
S&F in repair CP brass stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup complete all as specified & directed by Engr-in-Charge.
S&F in repair CP brass stop valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) complete all as specified & directed by Engr-in-Charge.
S&F 15 mm dia stop valve, fancy type chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified & directed by Engr-in-Charge.
,--ditto-- all as per serial item No 115 above but fancy type, chromium plated with long shank and cup (concealed type) complete all as specified & directed by Engr-in-Charge.
S&F in repair, shower rose, 125 mm size, brass chromium plated with sweivel joint complete all as specified & directed by Engr-in-Charge.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified & directed by Engr-in-Charge.
Dismentling of water tanks of capacity exc 500 and n.exc 1000 ltrs and removing from site complete all as specified & directed by Engr-in-Charge.
S&F rotational moulded polythene water storage tank (ISI marked) 500 ltr capacity vertical with closed top hoisted and fixed in position all as specified in SSR part-I.complete all as specified & directed by Engr-in-Charge.
S&F rotational moulded polythene water storage tank 2000 ltr capacity vertical with closed top hoisted and fixed in position all as specified in SSR Part - I all as directed.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed in repair complete all as specified and as approved by GE/Engineer-in-Charge.
,---ditto--- all as per serial item No. 123 above but 25 mm bore complete all as specified and as approved by GE/Engineer-in-Charge.
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe complete all as specified & directed by Engr-in-Charge.
S&F ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 25mm dia bore pipe all as specified and directed.
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe complete all as specified & directed by Engr-in-Charge.
,---ditto--- all as per serial item No 127 above but 20mm dia pipe complete all as specified & directed by Engr-in-Charge.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling or laid in floors complete all as directed.
,---ditto--- all as per serial item No 129 above but 15mm dia pipe, fixing only complete all as specified & directed by Engr-in-Charge.
,---ditto--- all as per serial item No 129 above but 20mm dia pipe complete all as specified & directed by Engr-in-Charge.
,---ditto--- all as per serial item No 129 above but 20mm dia pipe, fixing only complete all as specified & directed by Engr-in-Charge.
,---ditto--- all as per serial item No 129 above but 25mm dia pipe complete all as specified & directed by Engr-in-Charge.
Dismantling of cast iron pipes, jointed in cement mortar and tabing out of trenches if required upto 100mm dia complete all as specified and as directed by engineer-in-Charge.
Dismantling of cast iron pipes, jointed in cement mortar and tabing out of trenches if required 75mm dia complete all as specified and as directed by engineer-in-Charge.
Supply & fixing 100 mm bore cast iron hubless pipe waste and vent pipe in any length with or without ears laid in trenches/floor/wall including clamps, jointing with necessary coupling complete all as specified & directed by Engr-in-charge.
S&F in repairs cast iron type hubless P trap/CPWD floor trap 100mm bore with CP grating including jointing to waste pipe fixed with necessary coupling arrangement complete all as specified and directed by Engineer-in-charge.
S&F in repair 100mm bore cast iron hubless type door T equal/uneqal branch pieces (any radius) diminishing pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engineer-in-charge.
S&F in repair 100mm bore cast iron hubless type plain bends (any radius) dimining pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engr-in-Charge.
Supply only 100 mm bore sheilding (ss) coupling (with epdm rubber as per requirement complete all as specified and directed by Engineer-in-charge.
Supply & fixing 75 mm bore cast iron hubless pipe waste and vent pipe in any length with or without ears laid in trenches/floor/wall including clamps, jointing with necessary coupling complete all as specified & directed by Engr-in-charge.
S&F in repairs cast iron type hubless P trap/CPWD floor trap 75 mm bore with CP grating including jointing to waste pipe fixed with necessary coupling arrangement complete all as specified and directed by Engineer-in-charge.
S&F in repair 75mm bore cast iron hubless type door T equal/uneqal branch pieces (any radius) diminishing pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engineer-in-charge.
S&F in repair 75mm bore cast iron hubless type plain bends (any radius) dimining pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engr-in-Charge.
Supply only 75 mm bore sheilding (ss) coupling (with epdm rubber as per requirement complete all as specified and directed by Engineer-in-charge.
Supply & fixed Clamp for hanging/ fixed of 75mm/100mm hubless pipes complete all as specified and directed by Engineer-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store complete all as specified and directed by Engineer-in-charge. Note : Measured overalll as fixed along the cente line over fittings and accessories)
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer-in-charge.
S&F 110 mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door any radius complete all as specified and directed by Engineer-in-charge.
S&F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-charge.
S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) branch piece double (single Y) equal or unequal complete all as specified and directed by Engineer-in-charge.
S&F 110 mm dia PVC (SWR) bend any radius complete all as specified and directed by Engineer-in-charge.
S&F 75 mm dia PVC (SWR) bend with access door any radius complete all as specified and directed by Engineer-in-charge.
S&F PVC (SWR) floor trap, 75 mm dia with grating including jointing with solvent cement etc complete all as specified and directed by Engineer-in-charge.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-charge.
S&F in repairs 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engineer-in-charge.
S&F 40 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engineer-in-charge.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed by Engineer-in-charge.
M&L for damp proof course 20mm thick in CM 1:2 to horizontal or vertical surfaces including necessary formwork complete all as specified and directed by Engineer-in-charge.
M&L for reinforced cement concrete, type B1 1:2:4 using 20 mm graded stone aggregates in lintels upto 1.5m span, cills steps, seismic and other similar bands, plinth courses, copings, bed plates, and the like including weathering, slightly rounded or chamfered angles and throating, incl formworks complete all as specified and directed by Engineer-in-charge. Note : Reinforcement shall be measured and paid seperately.
M&L for sand filling in floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-charge.
M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick,watered and rammed to a true surface in Broken stone or boulders (15cm compacted thickness) complete all as specified and directed by Engineer-in-charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-charge.
S&F factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails frame shall be covered with heat moulded plain coloured PVC `C' channel having a PVC sheet strip of 20 mm width stuck and plain colour PVC sheets for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame complete all as specified and directed by Engineer-in-charge.
Surface excavation N.exc. (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
M&L for RCC Hume pipe Septic tank design to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation ,RCC M-30 Design mix in walls,Base slab,baffle walls and roof slab including beams etc with vent shaft ,manhole opening with cover connection etc complete with effective depth of 1.5 m and overall depth of 3 m for 50 users capacity (conventional type) complete all as specified and directed by Engineer-in-charge. Drg No. : TD/STR/10 sheet No. 1/1 dated 02/09/2001
Soakage well excavation, in any type of soil, foundation in PCC 1:3:6, Walls of honey combed masonary with top ring of M-25 concrete including intersepting chamber and screen chamber made of brick masonary in CM, RCC Cover slab in M-25/SFRC Cover interconnecting pipes of RCC/DWC Complete filled withbrick bats of size3m dia x4.5m effective depth complete all as specified and directed by Engineer-in-charge. Drg No. : ST/BPL/06 of sheet No. 1/1 dated 14/10/2005 (Details of soak well)
S&F Framed work such as grills,gratings,etc. With ands of bar shouldered or riveted or forged into spikes framed guard bars barred iron doors, any section of window and ventilator, ladders framed balusters walk ways railings frame work of watertanks and similar works conforming to fe. 290 Gde-E-165 all as spefified and directed by Engr-in-Charge.
E/M Portion Taking down carefully copper/aluminium point wiring (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately), and making good disturbed surfaces of walls, floors etc to match with existing surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down sub main wiring of any size/capacity complete all as specified and directed by Engineer-in-Charge.
M&L for concealed point wiring with two single core PVC insulated, unsheathed multistranded copper conductor cable of size 1.5 Sqmm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 Sqmm (FRLS) including MS shunk sheet metal box with 3 mm thick hylam sheet top cover of required size for mounting switches, sockets etc complete for One Light / fan point controlled by one, one way switch complete all as specified and directed by Engineer-in-Charge Note - Quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour.
,--ditto--- all as per Serial item no 173 above, but for one ceiling/exhaust fan point controlled by one switch and regulator complete all as specified and directed by Engineer-in-Charge.
,--ditto--- all as per Serial item no 173 above, but for one bell/buzzer point controlled by one bell push complete all as specified and directed by Engineer-in-Charge.
,--ditto--- all as per Serial item no 173 above, but for one 3 pin switch socket outlet, 5 Amp on the same board with other switches complete all as specified and directed by Engineer-in-Charge.
,--ditto--- all as per Serial item no 173 above, but for one 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed by Engineer-in-Charge.
,--ditto--- all as per Serial item no 173 above, but for Two way point controlled by two way switch complete all as specified and directed by Engineer-in-Charge.
,---ditto--- All as per serial item No 173 above but wiring with 4 Sqmm multistranded cable and earth wire with copper conductor of size 2.5 Sqmm for 15 Amps power point complete all as specified and directed by Engineer-in-Charge.
Supply and fixing piano switch flush button single pole one way 5 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix piano socket 2 in 1, 2/3 pin 6 Amp flush type 250 Volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fixing piano socket 2 in 1, 3 pin 5 Amp and 15 amp flush type 240 Volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fixing piano switch 15 Amp flush type 240 Volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fixing switch piano flush button single pole two way 6 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting 1 x 18 W, 230 Volts integral sleek polycarbonate LED Channel (composite type) with white acrylic cover including making connection complete all as specified and directed by Engineer-in-Charge.
S&F lamp holder insulated body with back plate for angle /batten fitting with LED of 9 watt complete all as specified and directed by Engineer in charge.
Supply and fixing piano bell push flush type 6 Amp complete all as specified and directed by Engineer-in-Charge.
S&F bell AC 230 volt single pole complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite two to three terminals/plate 5 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing fan regulator electronic solid state with steps suitable for 1200/1400mm sweep ceiling fan working on 230 volt AC complete all as specified and directed by Engineer-in-Charge. Make : Legrand/Anchor/Usha.
S&F sheet metal enclosure DB single pole and neutral for 240 Volt 8 way with 200 Amps rated busbar flush/surface mounting double door including wooden board complete all as specified and directed by Engineer-in-Charge.
S&F MCB single pole 240 volt 5-32 Amp 10 KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB SPN 240 Volt 32 Amps 10 KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB SPN 240 Volt 40 Amps 10 KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC Blanking Plates one way with internal lock complete all as specified and directed by Engineer-in-Charge.
M&L for Sub Main Wiring with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 4 Sqmm copper green colour earth wire complete all as specified and directed by Engineer-in-Charge. Note : Two run of 6 Sqmm & one run of 4 Sqmm & one run of PVC conduit with accessories shall be measured as one length.
M & L for Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level connected to GI strip 32x6 mm dia by means of bolts, nuts, check nuts and washers complete including earthing pit, chemical compound, earthing lead 32 x 6 mm dia up to 7.5 mtr, 20 mm dia medium grade GI watering pipe, GI protection pipe 40mm dia eath pit in PCC 1:2:4 type B-1 using 20 mm graded stone agggragate RCC pit cover including earth work complete all as shown Electrical Plate No - 5 of SSR-2009 (Part-I). Note : The unit rate shall include for excavation & earth work in any type of soil/strata, PCC 1:2:4 type B-I for pit & RCC 1:2:4 type B-I for cover with 8mm dia CTD Bar @150mm C/C both way, funnel with watering pipe 20 mm dia medium grade, 15mm dia light grade GI pipe up to 7.5 mtr long wiremesh complete all as specified and directed by Engineer-in-Charge.
Supply and fixing sheat metal including single pole and neutal with 2 Pin and earth plug and socket complete with 1 single pole 20 Amps 240 Volt, MCB complete including necessary fixing arrangement and all incoming and outgoing electric connection complete all as specified and directed by Engineer-in-Charge.
Taking down Exhaust fan 300 mm sweep single phase 240 V 50Hz and refixing the same including all electrical connection, fastners of required size complete all as specified and directed by Engineer-in-Charge.
S& F fresh air fan 300 mm sweep, suitable for operation on 230/240 volt, 50 Hz AC supply including louvers, grouting with fasteners, nuts/bolts etc, making hole/opening in wall complete all as specified and as directed by Engineer-in-charge.
S& F in replacement fresh air fan 300 mm sweep, suitable for operation on 230/240 volt, 50 Hz AC supply, plastic body including louvers, grouting with fasteners, nuts/bolts etc, making hole/opening in wall complete all as specified and as directed by Engineer-in-charge.
S& F ceiling fan 1200 mm sweep, suitable for operation on 230/240 volt, 50 Hz AC supply including canopy, fan blade, fan rod, flexible wiring for connection complete all as specified and as directed by Engineer-in-charge.
S&F fan hook suitable for hangingceiling fan and fixing in existing size of iron frame workincluding nut, bolt, washers etccomplete all as specified and as directed by Engineer-in-charge.
Taking down Hot water heater (Geyser) storage type AC 230 volts of capacity 25 Ltrs ISI marked and refixing the same after repair /replacement of element, thermostate, indicating lamp etc incl making connection and 02 Nos PVC pipe complete all as specified & directed by Engineer in charge.
Taking down existing ceiling fan and refixing at same location after servicing /repairing replaced of bush/ball bearing, condenser, wire, hanging clamp, rubber, lock, nut bolts, washers complete all as specified & directed by Engineer in charge.
Supply, laying and testing of Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and as directed by Engineer-in-charge.
M&L sand cushioning with dry coarse sand to underground cable protection complete all as specified and as directed by Engineer-in-charge.
Supply and laying best quality locally availble Sub class 'B' bricks(oldsize) for cable protection cover, laid flat and lay in trenches over tge cable complete all as specified and as directed by Engineer-in-charge.
M&L for repair to door hinges of MS housing of size 0.90X 0.60 m including necessary welding and painting the panel with two coat of synthetic enamelled paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F sheet metal enclosures MCB distribution box 3 phase TPN 4 ways single door complete all as specified and as directed by Engineer-in-charge.
S&F 4 pole isolator having current capacity 63 Amp complete all as specified and as directed by Engineer-in-charge.
S&F 25 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc laid in trenches complete all as directed.
Providing connection from existing pipe line by 25mm ferrule complete all as specified and as directed by Engineer-in-charge.
Supply and fixing factory made, sheet distribution boards DB, double door, protection class IP-30 suitable for mounting MCB/MCCB, confirming IS-13032 to IS-8623, BS-5484 with min 200 Amps rated copper bus bar, working on 240 Volt AC, SP & N 4 Ways complete all as specified and directed by Engineer-in-Charge.
S&F SPN 10 Amps-01 Nos (Incoming) MCBs in SPN DB 4 Way complete all as specified and directed by Engineer in Charge.
,--ditto--- all as per Serial item no 215 above, but SP 6 amp - 01 Nos (out going) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size 10 sqmm complete all as specified and as directed by Engineer-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and as directed by Engineer-in-charge.. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position.
Supply and fixing LED building security light fitting 25 Watt with epoxy powder coated sheet aluminium housing, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover and accessories complete incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer after taking down old u/s one complete all as specified and directed by Engineer-in-Charge.
M&L wiring for circuit/submain wiring along with earthwire 2 X 2.5 Sqmm and 1 X 2.5Sqmm earth wire of FR PVC insulated copper conductor, single core cable in PVC concealed conduit complete with making good the disturbed surfaces of wall and matching with adjoining surfaces all as directed by Engr-in-charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
SHIVA CONSTRUCTION COMPANY
Dashmesh Construction Company
Aggarwal brothers and company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .