| Sl No | Description | Qty | Unit | Goodwill Enterprises L2 | HYDROCON ENGINEERS L4 | Premier Engineering Company L6 | RISHABH ENGINEERS L3 | Raj Engineering Co. L1 | Swarn Engineers L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.01 | Dismantling Old damaged MCCB, Disconnecting outgoing and incoming connections and cables & marking them properly. Removing connections from earthling strip Carefully unbolt and remove from the Panel using proper lifting & Safety arrangements. | 18 | Job | 27,000 ₹31,860 | 81,000 ₹95,580 | 60,300 ₹71,154 | 14,400 ₹16,992 Lowest | 27,000 ₹31,860 | 53,100 ₹62,658 |
| 1.02 | P/O MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel having rating 630A, 50KA, FPMCCB , making connections, etc. as required. Make:- L&T/ Havells/C&S/HPL/ DJB approved | 2 | No. | 81,000 ₹95,580 | 55,000 ₹64,900 | 89,180 ₹1,05,232.4 | 80,880 ₹95,438.4 | 54,000 ₹63,720 Lowest | 86,000 ₹1,01,480 |
| 1.03 | P/O MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel having rating 400A, 50KA, FPMCCB , making connections, etc. as required Make:- L&T/ Havells/C&S/HPL/ DJB approved | 7 | No. | 1,99,500 ₹2,35,410 | 1,57,500 ₹1,85,850 Lowest | 3,02,960 ₹3,57,492.8 | 2,08,530 ₹2,46,065.4 | 1,85,500 ₹2,18,890 | 2,97,500 ₹3,51,050 |
| 1.04 | P/O MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel having rating 250A,50KA,FPMCCB, making connections, etc. as required Make:- L&T/ Havells/C&S/HPL/ DJB approved | 3 | No. | 58,500 ₹69,030 | 46,500 ₹54,870 Lowest | 54,300 ₹64,074 | 70,500 ₹83,190 | 58,500 ₹69,030 | 52,500 ₹61,950 |
| 1.05 | P/O MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel having rating 125A,36KA,FPMCCB, making connections, etc. as required Make:- L&T/ Havells/C&S/HPL/ DJB approved | 6 | No. | 84,000 ₹99,120 | 75,000 ₹88,500 | 45,000 ₹53,100 | 80,400 ₹94,872 | 44,400 ₹52,392 | 42,600 ₹50,268 Lowest |
| 1.06 | Installation of above MCCB’s at site as per direction of engineer-in- charge with the help of manual labor required tools, tackles and tackles, by placing new MCCB on the frame, leveling and align the MCCB by using plumb to ensure upright position, bolt MCCB’s securely to avoid vibrations. | 1 | job | 5,500 ₹6,490 Lowest | 95,000 ₹1,12,100 | 35,000 ₹41,300 | 18,000 ₹21,240 | 43,500 ₹51,330 | 32,400 ₹38,232 |
| 1.07 | Making electric connections by connecting incoming supply cables to incomer/MCCB/MCB, connect outgoing motor cables to respective contractors / starters, connect auxiliary connections indicator lamps, ammeters, voltmeters, auto manual selectors, connect ear thing properly to the earth bus bar. | 1 | job | 8,500 ₹10,030 | 10,000 ₹11,800 | 19,200 ₹22,656 | 8,000 ₹9,440 Lowest | 19,500 ₹23,010 | 18,000 ₹21,240 |
| 1.08 | Renovation of metering / indication system of the starters as below:-
a) Dismantling the old Meter / Selector Switch / indicating lights and defected control system etc. from the MCCB chamber.
b) Providing and fixing of the new instruments etc. including making their connections by wiring as required at the newly installed starter/MCCB chamber.
c) Setting and configuring the Meters as per the CT ratio and testing the parameters display as per requirement at site.
d)Checking wiring of meters, indicating lights etc. of the other existing starters with setting and configuring the existing Meters as per the CT ratio and testing the parameters display as per requirement at site | 1 | job | 15,000 ₹17,700 Lowest | 25,000 ₹29,500 | 36,700 ₹43,306 | 35,000 ₹41,300 | 39,000 ₹46,020 | 32,300 ₹38,114 |
| 1.09 | Testing and commissioning by checking all connection are tight and properly insulated, performing insulation resistance test, checking of ear thing continuity, test operation of individual components, energize the panel and check voltage each phase, Run the motor on no load to observe current, voltages, phase sequence, and run the motor on full load after all above checks. | 1 | job | 10,200 ₹12,036 | 2,500 ₹2,950 Lowest | 18,000 ₹21,240 | 5,000 ₹5,900 | 7,500 ₹8,850 | 14,499 ₹17,108.82 |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
30 Jul 2025, 11:15 amClosed
EE ENM M III
Delhi Jal Board C-Block Near Divya Jyoti Apartment, Sector-19 BPS Rohini, Delhi-89
Replacement of Damaged MCCBs n old Meters Selector Switch Indicator Lamps defected control system in LT PaneL at Sec 07 Rohini BPS Ward No 52 Rohini F under Rohini AC13
2025_DJB_275861_29
NIT NO. 09(2025-26) M-III
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M III
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
Account No SB 50448339804
₹15,000
Yes
27 Sept 2025
23 Jul 2025
30 Jul 2025
23 Jul 2025
30 Jul 2025
23 Jul 2025
Dismantling Old damaged MCCB, Disconnecting outgoing and incoming connections and cables & marking them properly. Removing connections from earthling strip Carefully unbolt and remove from the Panel using proper lifting & Safety arrangements.
P/O MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel having rating 630A, 50KA, FPMCCB , making connections, etc. as required. Make:- L&T/ Havells/C&S/HPL/ DJB approved
P/O MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel having rating 400A, 50KA, FPMCCB , making connections, etc. as required Make:- L&T/ Havells/C&S/HPL/ DJB approved
P/O MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel having rating 250A,50KA,FPMCCB, making connections, etc. as required Make:- L&T/ Havells/C&S/HPL/ DJB approved
P/O MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel having rating 125A,36KA,FPMCCB, making connections, etc. as required Make:- L&T/ Havells/C&S/HPL/ DJB approved
Installation of above MCCB’s at site as per direction of engineer-in- charge with the help of manual labor required tools, tackles and tackles, by placing new MCCB on the frame, leveling and align the MCCB by using plumb to ensure upright position, bolt MCCB’s securely to avoid vibrations.
Testing and commissioning by checking all connection are tight and properly insulated, performing insulation resistance test, checking of ear thing continuity, test operation of individual components, energize the panel and check voltage each phase, Run the motor on no load to observe current, voltages, phase sequence, and run the motor on full load after all above checks.
Goodwill Enterprises (BID ID -1607286)
RISHABH ENGINEERS (BID ID -1607469)
HYDROCON ENGINEERS (BID ID -1607296)
Swarn Engineers (BID ID -1607479)
Premier Engineering Company (BID ID -1607403)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .