Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-Finance SHOP NO 18 1ST FLOOR NORTH LAND BUILDING SECTOR NO 1 BACK SIDE OF BANK OF MAHARASHTRA INDRAYANI NAGAR BHOSARI PUNE 411039 | PUNE | MAHARASHTRA | 411039 | ₹30.1 L | L1 | Accepted-Finance being lowest L1 |
| 2 | L2₹30.7 L+₹59,818.90 (1.99%)Accepted-Finance | ₹30.7 L+₹59,818.90 (1.99%) | L2 | Accepted-Finance not being lowest |
| 3 | L3₹32.0 L+₹1.8 L (6.13%)Accepted-Finance 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | ₹32.0 L+₹1.8 L (6.13%) | L3 | Accepted-Finance not being lowest |
| 4 | L4₹34.6 L+₹4.5 L (14.9%)Accepted-Finance | ₹34.6 L+₹4.5 L (14.9%) | L4 | Accepted-Finance not being lowest |
| Sl No | Description | Qty | Unit | vishalconstruction L3 | CHEMSTICK ENTERPRISES L4 | ARK ENTERPRISES L2 | ShreHari Civil Enginneering and Contractors L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M &L Dismantling water tanks and removing to store capacity exc 500 & n.exc 1000 ltrs complete all as specified and directed.by Engineer-in-Charge. | 7 | Each | 500 ₹3,500 | 100 ₹700 Lowest | 200 ₹1,400 | 200 ₹1,400 |
| 2.00 | S&F For rotational moulded polyethylene water storage tanks 1000 liter Capacity cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.by Engineer-in-Charge. | 7 | Each | 1,100 ₹7,700 Lowest | 8,000 ₹56,000 | 11,000 ₹77,000 | 8,500 ₹59,500 |
| 3.00 | M&L 20mm bore dia ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed.by Engineer-in-Charge. | 14 | Each | 550 ₹7,700 | 550 ₹7,700 | 450 ₹6,300 Lowest | 1,000 ₹14,000 |
| 4.00 | Demolition of cement concrete (un-reinforced) in roof/floors other than ground level beam, stair case, landing, chajjas and similar items including water proofing treatment in any layers and removal of debris to distance exceeding 250m and not exceeding 500m from the site complete all as specified and directed.by Engineer-in-Charge. | 3.35 | Cum | 550 ₹1,842.5 | 500 ₹1,675 | 200 ₹670 | 150 ₹502.5 Lowest |
| 5.00 | M&L for 25 mm thick , Plain Cement Concrete 1:2:4 nominal mix (Type B0 using 12.5 mm graded aggregate) as in levelling course to match the undulations of roof and in in coping , roof kerbs, fins including benching etc complete all as specified and directed.by Engineer-in-Charge. | 80 | Sqm | 150 ₹12,000 | 350 ₹28,000 | 100 ₹8,000 Lowest | 130 ₹10,400 |
| 6.00 | M&L for roof treatment consists of following steps including taking down of existing unserviceable membrane complete all as specified and directed:
(a) 10mm thick cement plaster 1:3 with integral WPC @3% weight of cement (not measured seperately) to be laid over the RCC roof slab when the concrete is green.
(b) Applying a uniform coat of primer at 0.70 kg/sqm over cement plaster.
(c) 3mm thick and weighing not less than 3.6kg/sqm Atactic Polypropylene Polymer(APP) modified bitumen-based prefabricated five layer water proofing membrane reinforcement with non woven polyster matt black finished over compatible primer with non woven polyster matt black finished over compatible primer at 0.40ltr/sqm of density at 25 degree centigrade 0.87-0.89 kg/litre and viscosity 70-160 cps or cold sticker and torch application of membrane with 10 cm overlap both ways after necessary preparation of surface complete as per manufacturer's instructions.
(d) Apply two coats of bitumastic-alumunium paint over the membrane.
Note : (a) The work shall be executed through authorised manufacturer applicator only. (b) PV & test certificate of APP membrane shall be submitted along with RAR for processing payment. (c) Guarantee amount and bond in an non judical stamp paper for APP membrane against efficiency shall needed to be submitted for 10 years by the successful contractor after execution of subject work. | 124 | Sqm | 550 ₹68,200 | 525 ₹65,100 | 850 ₹1,05,400 | 500 ₹62,000 Lowest |
| 7.00 | Demolition of cement concrete(unreinforced ) in ground floors and pavings not exceeding 15cm thickness(below ;or above ground level) complete all as specified and directed.by Engineer-in-Charge. | 12 | Cum | 550 ₹6,600 | 500 ₹6,000 | 200 ₹2,400 | 150 ₹1,800 Lowest |
| 8.00 | M&L for 75mm thick Plain Cement Concrete type D-2 (1:4:8) using 20mm graded aggregate as in sub base etc complete all as specified and directed.by Engineer-in-Charge. | 80 | Sqm | 200 ₹16,000 Lowest | 250 ₹20,000 | 300 ₹24,000 | 250 ₹20,000 |
| 9.00 | M&L Non skid vitrified Ceramic tiles 10 to 12 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.18sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed.by Engineer-in-Charge. | 160 | Sqm | 1,100 ₹1,76,000 | 900 ₹1,44,000 Lowest | 950 ₹1,52,000 | 1,150 ₹1,84,000 |
| 10.00 | M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor/ wall finishes in CM 1:6. complete all as specified and directed.by Engineer-in-Charge. | 160 | Sqm | 150 ₹24,000 | 120 ₹19,200 | 200 ₹32,000 | 50 ₹8,000 Lowest |
Tender Value
₹41.4 L
EMD Value
₹82,732
Closing Date
8 Jul 2026, 6:00 pmClosed
Shri Vikas Tanwar, IDSE, GE (CME) Khadki
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi, Pune
SPECIAL REPAIR TO CERTAIN TOILETS OF BLDG NO P-691 OF DIPLOMA WING FCM AT CME PUNE
2026_MES_771191_1
8691/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (CME) Khadki
₹82,732
Yes
24 Aug 2026
10 Jun 2026
10 Jul 2026
10 Jun 2026
8 Jul 2026
25 Jun 2026
11 Jun 2026 - 24 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M &L Dismantling water tanks and removing to store capacity exc 500 & n.exc 1000 ltrs complete all as specified and directed.by Engineer-in-Charge. | 7 | Each | 1 | ₹7 |
| 2 | S&F For rotational moulded polyethylene water storage tanks 1000 liter Capacity cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.by Engineer-in-Charge. | 7 | Each | 2 | ₹14 |
| 3 | M&L 20mm bore dia ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed.by Engineer-in-Charge. | 14 | Each | 3 | ₹42 |
| 4 | Demolition of cement concrete (un-reinforced) in roof/floors other than ground level beam, stair case, landing, chajjas and similar items including water proofing treatment in any layers and removal of debris to distance exceeding 250m and not exceeding 500m from the site complete all as specified and directed.by Engineer-in-Charge. | 3.35 | Cum | 4 | ₹13.4 |
| 5 | M&L for 25 mm thick , Plain Cement Concrete 1:2:4 nominal mix (Type B0 using 12.5 mm graded aggregate) as in levelling course to match the undulations of roof and in in coping , roof kerbs, fins including benching etc complete all as specified and directed.by Engineer-in-Charge. | 80 | Sqm | 5 | ₹400 |
| 6 | M&L for roof treatment consists of following steps including taking down of existing unserviceable membrane complete all as specified and directed:
(a) 10mm thick cement plaster 1:3 with integral WPC @3% weight of cement (not measured seperately) to be laid over the RCC roof slab when the concrete is green.
(b) Applying a uniform coat of primer at 0.70 kg/sqm over cement plaster.
(c) 3mm thick and weighing not less than 3.6kg/sqm Atactic Polypropylene Polymer(APP) modified bitumen-based prefabricated five layer water proofing membrane reinforcement with non woven polyster matt black finished over compatible primer with non woven polyster matt black finished over compatible primer at 0.40ltr/sqm of density at 25 degree centigrade 0.87-0.89 kg/litre and viscosity 70-160 cps or cold sticker and torch application of membrane with 10 cm overlap both ways after necessary preparation of surface complete as per manufacturer's instructions.
(d) Apply two coats of bitumastic-alumunium paint over the membrane.
Note : (a) The work shall be executed through authorised manufacturer applicator only. (b) PV & test certificate of APP membrane shall be submitted along with RAR for processing payment. (c) Guarantee amount and bond in an non judical stamp paper for APP membrane against efficiency shall needed to be submitted for 10 years by the successful contractor after execution of subject work. | 124 | Sqm | 6 | ₹744 |
| 7 | Demolition of cement concrete(unreinforced ) in ground floors and pavings not exceeding 15cm thickness(below ;or above ground level) complete all as specified and directed.by Engineer-in-Charge. | 12 | Cum | 7 | ₹84 |
| 8 | M&L for 75mm thick Plain Cement Concrete type D-2 (1:4:8) using 20mm graded aggregate as in sub base etc complete all as specified and directed.by Engineer-in-Charge. | 80 | Sqm | 8 | ₹640 |
| 9 | M&L Non skid vitrified Ceramic tiles 10 to 12 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.18sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed.by Engineer-in-Charge. | 160 | Sqm | 9 | ₹1,440 |
| 10 | M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor/ wall finishes in CM 1:6. complete all as specified and directed.by Engineer-in-Charge. | 160 | Sqm | 10 | ₹1,600 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
8691tender.pdf
Tender Documents • 0.97 MB
BOQ_863618.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .