| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹33.7 L+₹4.0 L (13.4%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹34.1 L+₹4.4 L (14.9%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹37.5 L+₹7.8 L (26.2%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L4 | Rejected-Finance Being other than lowest | |
| 5 | Rejected-Technical RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | - | Rejected-Technical Bidder not enlisted with appropriate category i.e c (i) |
Tender Value
₹43.3 L
EMD Value
₹86,540
Closing Date
1 Apr 2024, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
PROVN OF ALUMINIUM PARTITION, PATH TILE, DRAIN AND SPLIT AC AT P-182 NEW OPD COMPLEX AT BASE HOSPITAL UNDER GE (EAST) DELHI CANTT-10
2024_MES_645871_1
GE/DE-127/2023-24
Open Tender
Civil Works
Item Rate
120 days
GE (EAST) DELHI CANTT-10
Class D Cat c (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹86,540
Yes
12 Jun 2024
11 Mar 2024
3 Apr 2024
11 Mar 2024
1 Apr 2024
25 Mar 2024
Amount
Supply and installation of air cooled inverter based split AC unit (Hot & Cold functions) with virat mode capacity of 110% upto infinite time, Air conditioner is electric driven single phase of capacity 1.5 TR, minimum 3 star rating with charged with Eco friendly Refrigerent, and comes with special health filter and all connected accessories and copper tubing from indoor to outdoor up to 2m length and making of hole in any type of wall, including PVC drain pipe from indoor unit up to 2m length , Outdoor split AC hanging wall mounted/ floor mounted stand and flexible PVC casing pipe up to industrial skt minimum 40mm dia covered on all exposed copper insulated pipe line and PVC wire etc complete all as specified and directed by eng-in-charge. Make : LG, Model No: TS-H19VNXE or equivalent Hitachi/ Daikain/ Voltas/ Mitshubushi
Supply and fix Copper pipe of 1\4'' size as per requirement for inlet and outlet with nitrile insulation complete all as specified and directed.
Supply and fix Copper pipe of 1\2'' size as per requirement for inlet and outlet with nitrile insulation complete all as specified and directed.
Supply and fix Drain pipe flexible type of suitable size complete all as specified and directed.
Supply and fix Drain pipe hard type of suitable size complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA. Make : Bluebird/ V gaurd/ Volina/ Microtec
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium couductor of 185 X 3.5 Core complete all as specified and directed. (Note : Cable connection from exsting transformer to existing LT panel also included in price)
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium couductor of 120 X 3.5 Core complete all as specified and directed.
S&F MCCB 4 Pole 415 Volts, adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed. Make : Legrand/ L&T/ Schenider/Insoasian
S&F MCCB 4 Pole 415 Volts, adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed. Make : Legrand/ L&T/Schenider/Insoasian
S&F MCCB 4 Pole 415 Volts, adjustable type, 100 Amps with breaking capacity 25 KA complete all as specified and directed. Make : Legrand/ L&T/ Schenider
S & F VTPN DB 8way, double door (CRCA sheet), metal type, dust and vermin proof VTPN 8 way with 250 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand/ L&T/ Schenider
S & F TPN DB 4way, double door (CRCA sheet), metal type, dust and vermin proof, TPN 4 way with 100 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand/L&T/ Schenider
S & F SPN DB 8way, double door (CRCA sheet), metal type, dust and vermin proof, SPN 8 way with 100 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand/L&T/ Schenider
S & F MCB TPN, C curve, 415 volts, 63 Amps, complete all as specified and directed. Make : Legrand/L&T/ Schenider
S&F sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 25 Amps, 240 Volts complete all as specified and directed. Make : Legrand/L&T/ Schenider
S & F MCB SPN, C curve, 240 Volts, 63 Amps, 10KA complete all as specified and directed. Make : Legrand/L&T/ Schenider
S & F MCB SP, C curve, 240 Volts, 63 Amps, 10KA complete all as specified and directed. Make : Legrand/L&T/ Schenider
S & F MCB SP, C curve, 240 Volts, 32 Amps, 10KA complete all as specified and directed. Make : Legrand/L&T/ Schenider
M&L for sub main wiring with 4 runs of 16.0 sqmm single core, PVC insulated & unsheathed (FR) cable 1100 Volts grade with multi stranded, copper conductor drawn in and including PVC casing caping of suitable size as per ISS and one run of 16.0 sqmm size as earth wire PVC insulated copper conductor complete all as specified and directed.(Note. four run of cable and earth conductor shall be measured as one length) Make :Make-Havells/Finolex/Polycab.
M&L for sub main wiring with 2 runs of 10.0 sqmm single core, PVC insulated & unsheathed (FR) cable 1100 Volts grade with multi stranded, copper conductor drawn in and including PVC casing caping of suitable size as per ISS and one run of 10.0 sqmm size as earth wire ,PVC insulated copper conductor complete all as specified and directed.(Note. Two run of cable and earth conductor shall be measured as one length) Make :Make-Havells/Finolex/Polycab.
M&L for sub main wiring with 2 runs of 4.0 sqmm single core, PVC insulated & unsheathed (FR) cable 1100 Volts grade with multi stranded, copper conductor drawn in and including PVC casing caping of suitable size as per ISS and one run of 4.0 sqmm size as earth wire, PVC insulated copper conductor complete all as specified and directed.(Note. Two run of cable and earth conductor shall be measured as one length) Make :Make-Havells/Finolex/Polycab.
M&L in repair Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using GI strip 32 X 6mm as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm bore GI medium grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
M&L for GI strip 32x6 mm for earthing complete all as specified and directed.
Excavating in trenches, for soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm for soft/loose soil complete all as specified and directed.
M&L for removing excavated materials n.exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L sand filling in and around LT/HT cables 8 cm thick below and 15 cm above the cable respectively after laying the cable and gently punned down complete all as specified and directed.
Supply and laying of brick having size 230mm x 115mm x 75mm for cover LT UG cable any size complete all as specified and directed.
S & F in replacement of GI pipe of light grade of size 50mm bore with all fitting laid in trenches complete all as specified and directed.
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed.
M&L for 25mm thick PCC type B-0 using 20mm graded crushed stone aggregate as in sub base for laying floor finishes complete all as specified and directed.
M & L for Durastone heavy duty Matte of size 400 mm x 400 mm and 12mm thick Vitrified Parking tile/Pavement tile in floors, set and jointed in neat cement to match the shade over and including 20 mm thick screed bed in CM 1 : 6 complete all as specified and as directed.
S&F 4 mm thick Aluminium Composite Panel cladding of approved quality and colour as approved by GE, fixing in MS frame at any height and including MS frame of size not exc 0.36 sqm (used in rect angular tubes of size 50.8mm x 25.4mm x 2.9mm thick or square tubes 38 mm x 38 mm x 2.9mm thick are used in frame) and filling the joints with all weather silicon sealant including all mouldings, cuttings, etc complete all as specified and directed .(Make - ACP Aluedecor, Alstrong, Wonder Alu Board Overseas, VIVA , Eurobond.
M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) work for partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including clear angle, Aluminium snap beading for glazing/ paneling, C.P brass/ stainless steel screws, 5.5mm sheet glass & 12mm th Prelaminated particle board exterior grade prelaminated both sidewith decorative choice complete all as specified and as directed.
S&F Powder Coated aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door, hinges, Tower bolt 150mm,Sliding bolt 300mm, anodised snap beading screws etc powder coating of any colour (thickness or powder coating not less than 50 micron) complete all as specified and as directed.
S&F Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc (minimum thickness of powder coating 50 micron) complete all as specified and as directed.
S&F 12mm thick Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed in Alun/ timber frame work complete all as specified and as directed.
S&F Aluminium Door closer hydraulically regulated, designation No. 3, Universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and as directed. Make- Sandhu/ Plaza/ Godrej/ Hardwyn
S&F Brass Mortice lock 4 levers, vertical type, size 100 mm complete all as specified and directed. Make- Plaza/ Godrej/ Harrison
M&L for preparation of Old plastered wall surfaces & applying one coat of oil bound distemper complete all as specified and as directed.
M&L for 20 mm thick of approved shade granite stone (Zed Black) (Superior Quality) slab (table rubbed and polished as in floors, jambs,steps,cooking platform,window cills etc and the like, over & incl 15 mm thick screed in CM 1:4 incl pointed in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including two strip of line make of (Tread of stair case) granite complete all as specified and directed
M&L RCC slab type B1 1:2:4 (20 mm graded stone aggregate (nominal mix) supported on walls, beams and columns in floors, landings, balconies, shelves etc complete all as specified
M&L Formwork to suspended slab such as roof slabs , floor slab, landings and similar work not exceeding 200 mm thick ( horizontal or sloping ) for flat surfaces.& side.
M&L MS TMT bars 10mm dia and over cut to length ,bent to shape required incl cranking , bending , hooking, for lintel and binding with MS wire not less than 0.9 mm dia or securing with clips.
M & L for brick work with sub-class B brick straight or curved on plan built in cement mortar 1 : 6 complete all as specified and directed
M & L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or on concrete surfaces finished fair and even without using extra cement.
M & L for preparing new concrete surface and applying one coat of 2mm thick of wall care putty as levelling course, then scrubbing by sand paper to prepare a even surface and applying two coats of exterior emulsion paint of colour & shade as approved over one coat of priming paint complete all as specified and as directed. Make - Asian Apex Ultima or equivalent of make specified in PS.
M&L for PCC type D -2 (1:4:8) using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete.
M/L PCC 1:3:6 type C2 ( using 40 mm graded stone aggregate) as in surfaces channels,drains etc.
M&L cement concrete 1:2:4 type B0 (using 12.5mm g raded aggregate) as in lintels upto 1.5 Mtr, cills, parapets, copings, apex stones, bed plates kerb etc all as specified and as directed.
M&L for 300 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars.
M & L for PCC 1:3:6 type D2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 300 mm bore.
M&L for framed work such as grills grating, etc with ends of bars shouldered and /or riveted for forged into spikes framed guard bars, barred iron doors ladders framed balusters, walk ways, railings framework of water tanks and similar work conforming to Fe-290, Gde-E-165 all as directed by the Engr-in-Charge.
M&L for preparation of new steel surfaces & applying two coat of Synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
Saini Enterprises
M/S Rohit Enterprises
Vishal Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .