| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹24.6 L+₹2.5 L (11.3%)Rejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹26.9 L+₹4.8 L (21.9%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹31.4 L+₹9.3 L (42.2%)Rejected-Finance H NO 861 SECTOR 1 4 HOUSING BOARD COLONY NEAR POLY CLINIC HISAR HARYANA | HISAR | HARYANA | 125001 | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
2 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE HISAR
GE HISAR
CA NO GE(H)-75/2023-24 REPAIR / MAINT OF ROAD LIGHTS, PANELS, POLES, AND OTHER CONNECTED ITEMS IN WESTERN AREA AT HISAR MIL STN UNDER GE HISAR
2024_MES_640573_1
CA NO GE(H)-75/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
HISAR
AS PER NIT
6 documents required · 6 mandatory
₹500
GE HISAR
₹70,000
Yes
30 Apr 2024
3 Feb 2024
4 Mar 2024
3 Feb 2024
2 Mar 2024
18 Feb 2024
Amount
M&L for checking street light, junction box connection including MCB, MCCB, street light timer connection, cable to overhead lines, overhead conductor jumper and other connected items of street light of any type and any capacity fixed in any position i.e. on wall/pole/watch tower/High mast for repairing in presence of MES rep to ascertain defective parts of the fitting and preparing list of defective parts to be repalced for making the fitting fully functional testing and refixing the fitting in its original position after repairs complete all as specified & directed. Notes for Item No 1.00 :- (a) Items required for repair / replacement work will be measured and paid for separately as "S&F in replacement". (b) Scope of work includes for minor stores e.g. PVC insulation tapes, screws, insulation sleeves, nuts, bolts, washers and flexible cable 23/0.0076 (for internal wiring) etc as required at site. (c) Any complained measured one time in same locatin/pole/light/panel during contract period : no extra payment will be made for repeating complaint on same location during contract period. (d) Contractor shall depute daily two Nos electrician in MES office for receiving and rectify the complaints. (e) The rate inclusive of all the T&P i.e ladder, vehicle required for execution of works shall be arranged by the contractor. (f) Complaint register and Complaint slip shall be maintained by the department at MES power house/MES office and complaint slip shall be issued to electrician by the JE E/M or MES staff. The cost of the complaint register and comlaint slip is deemed to be included in the quoted rates. (g) The contractor shall fully responsible for entry /exist of electrician in the station. (h) Contractor shall take all preventive measures to avoid any accident/mishap due to negligence of his workman. Contractor shall be responsible for any mishap, accident and loss to life of the workmen engaged in the work and nothing extra shall be admissibe on this account by the department. (j) At all day including sunday and holiday 02 persons should be present for attending complaints, complaints should be attinded with in day or penality of Rs 500/ day will be imposed for non attinding complaints.
S&F in replacement LED flood light fitting of cap 120 Watt, 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed. Make: Crompton Cat Part No. TFS-504-120-57-60D-HL2-GL-NSG, Orient cat Part No LFSMP-120-C, Havells Cat Part No. JETAIRISFLS120WLED757PASYMLTG, WIPRO Cat uar
S&F in replacement LED flood light fitting of cap 100 Watt, 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed. Make : Crompton Cat Part No. CFS-504-100-57-60D-HL2GL-NSG, Orient cat Part No LFSMP-100-C, Havells Cat Part No. JETAIRISFLS100WLED757PASYMLTG, WIPRO Cat Part No. LF20-122-060-57-G2 Surya Cat No SLE FL 100W IP66 LMS NEO, Jaquar Cat No LFLDSLM100XC
S&F in replacement LED flood light fitting of cap 70Watt, 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed. Make: Crompton Cat Part No. TFS-504-70-57-60D-HL2GL-NSG, Orient cat Part No LFSMP-070-C, Havells Cat Part No. JETANEOFL70WLED757LTG, WIPRO Cat Part No. LF20-102-060-57-G2, Surya Cat No SLE FL 80W IP66 LMS NEO, Jaquar Cat No LFLDSLM070XC
S&F in replacement post top LED lantern of capacity 40 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and LED lamp all all as specified & as directed Make : Cat Part No LPTO-40CDL-M of Crompton , Cat Part No SLE PT 40W ETPP of Surya , Cat Part No LGTP06X040XC of Jaquar
S&F in replacement post top LED lantern of capacity 20 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and LED lamp all all as specified & as directed Make : Cat Part No CBP-610-25-57-SL-CA-NBK of Crompton , Cat Part No SLE PT 30W-HARY of Surya , Cat Part No LGTP02X030XW of Jaquar
S&F in replacement LED drivers 35 to 100 watt cap complete all as specified & directed. Make:- Crompton , Surya , Jaquar
S&F in replacement surge protection device 10 KV for LED light fitting complete all as specified & directed.
S&F in replacement street light bracket made to shape out of GI pipe 25 mm bore light grade, 1.5 meter length fixed with & including necessary MS Clamps of size 40x5mm including nuts, bolts and washers on pole etc complete all as specified and directed.
S&F in replacement cable FRLS, PVC insulated and PVC sheathed size 2.5sqmm three core multistranded copper conductor cable including PVCwire connection complete all as specified & directed.
S&F in replacement rigid non-metallic PVC conduit 20mm dia with fittings like tees , bends, elbow, reducer, bell mouth tube ends and fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc complete fixed on wall / ceiling all as specified and as directed.
S&F in replacement cable FRLS, PVC insulated and PVC sheathed size 1.5sqmm three core multistranded copper conductor cable including PVCwire connection complete all as specified & directed
Prunning / trimming the branches of trees if any along overhead line, 3 mtr on all side below/ above/ sides of overhead line and removing the same upto 150 mtr away each span not exceeding 70 mtr etc complete all as specified and directed. Note :- The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required.
M&L for preparation of old painted surface of steel tubular LT poles 9m / 11m long and applying two coats of synthetic enamel paint with black and white or yellow strips 30cm wide each upto 1.5m height from top of PCC foundation block and on remaining surface of steel pole applying one coat of aluminium paint after preparation of old steel surfaces including marking of numbering of poles with synthetic enamel paint white in colour in 80mm high letters over 150mm x 230mm yellow base and applying one coat of cement base paint on PCC pedestal complete all as specified and directed.
Labour only for disconnecting, taking out defective under ground LT cable of length not more than 3 meter and of size 10 sqmm to 25 sqmm including excavation, taking out bricks cover and relaying the old cable in loop and making connection with proper new thimbles with cut out boxes,Feeder pillar box, MCBs etc including refilling of sand, relaying old bricks and returning, filling in soil etc complete all as specified and directed.
S&F in replacement PVC junction box suitable for street light of size not less than 350mm x 250mm x 150mm, made out of polycarbonate having front side openable shutter duly provided with locking arrangement and provided with 04 Nos aluminium bus bar of rating 200 Amp alongwith 01 No MCB 6 Amp SP and provision of 02 Nos cable entries of size upto 16 sqmm 4 core, fixed on any type of street light pole with proper size MS clamp with nut & bolt and connected assessories complete all as specified and directed. Note:- MS streep, nuts, bolts and washers will be measured and paid separetaly
Re-stringing / Re-stretching including jointing in situ of each span not more than 45 Mtrs between two electric poles having 3 to 5 Nos of ACSR conductors including GI earth continuity wire, with/ without guarding wires on electric poles of any size at different locations all as ordered manually or by telephonically means to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete as ordered.
Taking out the old unserviceable LT underground cable upto 16 sqmm 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc complete all as specified and directed . Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ.
Supply , laying , jointing, testing and commissioning of size 6 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed.Note : Excavation, earth work, sand cushion & brick protection shall be paid separately.
Supply , laying , jointing, testing and commissioning of size 10 sqmm 4core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed.Note : Excavation, earth work, sand cushion & brick protection shall be paid separately.
Supply , laying , jointing, testing and commissioning of size 16 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed.Note : Excavation, earth work, sand cushion & brick protection shall be paid separately.
Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part - I of size 50mm outer dia and 38 mm inner dia complete all as specified and as directed
S&F in replacement twin core flat 6 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed complete all as specified and directed.
S&F in replacement twin core flat 10 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed complete all as specified and directed.
Excavation in trenches in soft/loose soil n exc 1.50 meter wide and n exc 1.50 meter in depth for foundation of pole, laying cable etc and getting out etc complete all as specified and directed.
All as per Serial item No 25.00 (here-in-before) but in soft disintegreted rock / laterite rock / bituminous road.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
Taking up bricks laid as cable covers and stacking serviceable brick for reuse at site etc complete all as specified and directed.
Laying only old bricks retrieved from item srl No. 28.00 as cable covers in trenches etc complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point etc complete all as specified and directe.
Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm thick etc complete all as specified and directed.
M&L for Boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine complete all as specified and directed.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed.
M&L for 150mm thick PCC 1:2:4 type B2 using 40mm graded crushed stone aggregate as in sub base as directed) all as specified and as directed.
S&F in replacement MCB SP of capacity 6A to 40A , 10 KA, type 'C', 240 volts complete all as specified and directed. Make:- Havells, L&T, Legrand, Simens
S&F in replacement MCB TPN of capacity 40A to 100A,10 KA, type 'C',240 volts complete all as specified and directed.Make:- Havells, L&T, Legrand, Simens
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles complete all as specified and directed.
Supply, install, testing and commissioning of LT Feeder pillar distribution panel board CPRI approved outdoor type, horizontal type, double door system, weather proof, dust and vermin proof, made out of 40x40x6mm angle iron frame and 3.15mm thick CRCA sheet duly powder coated of suitable size with push type locking arrangement, factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type, 3 phase 4 wire system including wiring with suitable size rated current carrying capacity aluiminium bus bar with epoxy insulated coating with colour code and insulated support, complete with following accessories and suitable for accomodate the following MCB's etc complete and mounting the panel board on ground with PCC(1:3:6) bedding upto height of 30 cm above ground level complete all as specified and as directed (a) 200 Amps aluminium bus bar for all three phases and neutral - 01 set. (b) MCCB 63A as incoming - 01 No (c) MCB TPN 32 Amp - 05 Nos (v) Indicating lamps R, Y, B : 01 set of three (d) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples
Dismantling unserviceable concrete pole/struts of any size removing from site etc complete all as specified and directed.
Supply, erecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 9 mtr long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class 10 complete all as specified and directed by Engineer- in-charge. Note :- (i) The rate quoted shall deemed to included taking out conductors, earthwire from existing pole and refixing to newly errected pole. (ii) Earth work & PCC shall be measured and paid separately.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete.
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles complete all as specified and directed.
Dismantling insulator any type/ any size from LT poles complete all as specified and directed by.
S&F pin type insulators LT 1100 Volts grade porcelain vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washers, one galvanised iron nut, 100 mm height, 65 mm dia all as specified and directed.
M&L for providing shackle type insulator LT 1100 volt grade porcelain vitreous white or brown including galvanised insulator bolts, nuts 12 mm dia and washer including 31x3mm galvanised mild steel straps, 75 mm height and 90 mm dia of insulator complete all as specified and directed.
S&F in replacement of MCCBs of capacity 100 Amps, FP, 25 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed
S&F in replacement of MCCBs of capacity 63 Amps, FP, 16 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed
M&L in replacement of PVC separator in position to keep ACSR conductor as equal spacing complete all as specified and directed by Engineer-in-Charge suitable for 2 Wire of ACSR conductors
All as per Srl item No '49.00' (here-in-before) but 5 Wire complete all as directed
Supply and fixing in replacement Aluminium conductor steel reinforced (ACSR) of any size for LT OH lines on poles including stringing ,binding with aluminium wire 14 SWG or aluminium tape incl jumpers complete connecting of disconnected cable, service cable and street light connection complete all as specified and directed.
M/s Devendera construction
M/S SURJIT CONSTRUCTION COMPANY
Natwadia Electrical Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .