Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance N A | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹5,939
Closing Date
22 Dec 2023, 12:00 pmClosed
Ex. Engineer (Elect)-II
OFFICE OF THE Ex. ENGINEER (ELECT)-II, SHAHDARA (N) ZONE, KeshavChowk, Delhi-110053
Provision of Electrical Installations in Newly Constructed Malaria Circle Office in Ward No. 246, 249 and 250 Under Shahdara (North) Zone
2023_MCD_178035_1
EE(E)-II/SNZ/MCD/23-24/TC-29/3
Open Tender
Electrical Works
Item Rate
120 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹5,939
4 Jan 2024
15 Dec 2023
22 Dec 2023
15 Dec 2023
22 Dec 2023
15 Dec 2023
Amount
OD14071/2023-2024:(1.10.3) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required.. Group C
OD14072/2023-2024:(1.5) Wiring for light/ power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
OD14073/2023-2024:(1.14.22) Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x2.5 sqmm + 1x2.5 sqmm earth wire
OD14074/2023-2024:(1.14.4) Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x6 sqmm + 1x6 sqmm earth wire
OD14082/2023-2024:(1.24.1) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections etc. as required. 5/6 amps switch
OD14083/2023-2024:(1.24.4) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections etc. as required.3 pin 5/6 amp socket outlet
OD14084/2023-2024:(1.32)Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and 15/16 A modular socket outlet and 15/16 A modular switch connections etc as required.
OD14085/2023-2024:(2.3.1) Supplying and fixing following way, single pole and neutral , sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, double door
OD14086/2023-2024:(2.12.2)Supplying and fixing following rating, double pole 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amp
OD14087/2023-2024:(2.10.1)Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD14088/2023-2024:(2.14.2)Supply and fixing 25A rating double pole,(single phaseand neutral) 240 volts, residual current circuit breaker(RCCB) having a sensitivity current 30mA in the existing MCB DB complete with connection testing and commissioning etc as required.(40 amp)
OD14089/2023-2024:(19.1)supply, installation, Testing and commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Currect (BLDC) Motor, class of insulation:B, 3 nos blades, 30 cm down rod, 2 nos. canopies, shackle kit, safety ropr, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, Earthng etc. complete as required.
OD14090/2023-2024:(1.50.1) Installation of exhaust fan in the existing opening, including making good the damage, connection testing, commissioning etc as required.(upto 450 mm sweep)
OD14091/2023-2024:DSR-22(5.1) Earthing with G.I. earth pipe 4.5 mtr long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) as required.
OD14092/2023-2024:DSR-22(5.12) Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
OD14093/2023-2024:(7.7.1)Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.28:SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.176:Supplying & Installation of Hot Cold & Normal Floor Standing Top Loading Water dispenser with Cooling Cabinet Fridge cold water storage capacity up to 3.5 ltr with hot water storage capacity up to 1 ltr as required.
122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .