| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC 161 SADAR BAZAR SADAR BAZAR CANTT AYODHYA UP PIN 224001 | AYODHYA | AYODHYA | UP | 224001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.9 L+₹2.2 L (28.4%)Rejected-Finance D 2 36 VIBHUTI KHAND GOMATI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226010 | L2 | Rejected-Finance Not Being L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical No enlistment in category of works c(i) as per NIT |
| Sl No | Description | Qty | Unit | Lucknow Refrigeration L2 | Jairajyadav security services L1 |
|---|---|---|---|---|---|
| 1.00M&L for dismantling the cover of condensor and cooling coil, thoroughly cleaning the external surface (both side) of all the component including fins, base using de-scaling solution of chemicals mix, water etc with the help of air blower, wire brushing and reassemble all the components plate, runner, fan blade etc in original position as and when directed for following capacity of Air Conditioners: - | |||||
| 2.00 | Window Type Air Conditioner 1/1.5/2 TR capacity. | 25 | Job | 400 ₹10,000 | 220 ₹5,500 Lowest |
| 3.00 | Split type Air Conditioner 1/1.5/2 TR capacity (1 x Indoor unit and 1 x Outdoor unit) | 50 | Job | 500 ₹25,000 | 250 ₹12,500 Lowest |
| 4.00 | S&F in replacement AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit. | 5 | Each | 250 ₹1,250 Lowest | 350 ₹1,750 |
| 5.00 | S&F in repair of PCB single phase 230V for split/window AC of capacity 1.5/ 2.0 TR. | 20 | Each Job | 950 ₹19,000 | 580 ₹11,600 Lowest |
| 6.00 | S&F in replacement AC single phase 230 volts remote (Hand set) for 1.5/ 2.0 TR capacity window/split AC complete all as specified. | 15 | Each | 650 ₹9,750 | 350 ₹5,250 Lowest |
| 7.00 | M&L for replacement of blower motor for 1.5/2 TR window. | 10 | Each | 1,215 ₹12,150 Lowest | 1,400 ₹14,000 |
| 8.00 | M&L for replacement of runner motor for 1.5/2 TR split AC. | 10 | Each | 715 ₹7,150 Lowest | 850 ₹8,500 |
| 9.00 | M&L for replacement of strainer for window/split AC of any capacity. | 30 | Each | 35 ₹1,050 Lowest | 210 ₹6,300 |
| 10.00 | M&L for replacement of 4/6 mfd capacitor for blower motor of window/split AC of any capacity. | 25 | Each | 51 ₹1,275 | 40 ₹1,000 Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
18 Oct 2025, 6:00 pmClosed
AGE (I) Ayodhya Cantt
Asst Garrison Engineer (I), Military Engineer Services, Ayodhya Cantt PIN-224001
REPAIR/MAINT OF UNSERVICEABLE SUMMER APPLIANCES, REFRIGERATORS, DEEP FREEZER, WATER COOLER AND CERTAIN ALLIED WORKS UNDER AGE(I) AYODHYA
2025_MES_730977_1
8400/124/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Ayodhya
₹20,000
Yes
11 Mar 2026
15 Sept 2025
20 Oct 2025
15 Sept 2025
18 Oct 2025
29 Sept 2025
Amount
M&L for dismantling the cover of condensor and cooling coil, thoroughly cleaning the external surface (both side) of all the component including fins, base using de-scaling solution of chemicals mix, water etc with the help of air blower, wire brushing and reassemble all the components plate, runner, fan blade etc in original position as and when directed for following capacity of Air Conditioners: -
Window Type Air Conditioner 1/1.5/2 TR capacity.
Split type Air Conditioner 1/1.5/2 TR capacity (1 x Indoor unit and 1 x Outdoor unit)
S&F in replacement AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit.
S&F in repair of PCB single phase 230V for split/window AC of capacity 1.5/ 2.0 TR.
S&F in replacement AC single phase 230 volts remote (Hand set) for 1.5/ 2.0 TR capacity window/split AC complete all as specified.
M&L for replacement of blower motor for 1.5/2 TR window.
M&L for replacement of runner motor for 1.5/2 TR split AC.
M&L for replacement of strainer for window/split AC of any capacity.
M&L for replacement of 4/6 mfd capacitor for blower motor of window/split AC of any capacity.
M&L for replacment of 36/50 mfd running capacitor for compressor of window/split AC of any capacity.
M&L for replacement of 80/100 starting capacitor for compresor of window/split AC of any capacity.
M&L for replacement of thermostat for 1.5/2 TR window/split AC.
M&L for replacement of sensor for 1.5/ 2.0 TR window/split AC
M&L for replacement of fan blade of blower motor for 1/1.5/2 TR window/split AC.
M&L for replacement of over load protector for 1.5/2 TR window/split AC.
M&L for replacement of capillary copper tube of size 0.064 inch dia
M&L for replacement of runner for 1.5/ 2.0 TR window/split AC.
M&L for replacement of starting relay for 1.5/2 TR window/split AC.
M&L for replacement of air filter for 1.5/2 TR window/split AC
Disconnecting electrically and mechanically and taking out existing unserviceable sealed compressor unit from 1.5 TR AC of any make and S & F in replacement new sealed compressor suitable for 1.5 TR AC and connecting up suction and discharge pipe line with gas welding and gas charging complete all as specified. Make: LG/Blue Star/Voltas/Carrier
All as per item No 21 above but for 2 TR AC. Note:- for Item No21&22 : Compressor/sealed unit shall have one year replacement guarantee from date of installation.
S&F in replacement of swing motor as per existing size and type for 1.5/2 TR window.
S&F in replacement of swing motor as per existing size and type for 1.5/2 TR split AC
S&F in repair 20mm dia PVC pipe, heavy duty for drain out of condensing water of window/split AC including cutting of floors or making hole in wall and making good the disturbed portion after laying pipe with sadles etc to match the existing surface with original specifications complete all as specified.
S&F in repair copper pipe (hard) 5/8" dia with PUF insulation, CFC free etc as required at site complete all as specified.
S&F in repair copper pipe (hard) 3/8" dia with PUF insulation, CFC free etc as required at site complete all as specified.
M&L for nitrogen testing for leakage in cooling/condensing coil after flush out the refrigerant gas and before the test, nitrogen gas used to purge the system for any remaining refrigerant, air or moisture all as specified and directed by Engineer-in-Charge.
M&L for taking out and dismantling the existing rusted unserviceable condensor coil from existing system of 1/1.5/ 2.0 TR window/split AC located at different places after decanning refrigerent gas from the system to empty cylinder, disconnecting all electrical connection, flair nuts, valves and shut down all preventive valves properly, supply and replace with new condensing coil as per existing size and specification including necessary fixing arrangement and electrical connection and safety protection devices to the existing system and flushing the whole system by nitrogen, leak testing by 200 PSI nitrogen pressure holding of 48 hours, charging of decanning refrigerent to the system and charging of additional refrigerent as required, commisioning and testing complete all as specified.
M&L for taking out and dismantling the existing rusted unserviceable cooling coil from existing system of 1/1.5/ 2.0 TR window/split AC located at different places after decanning refrigerent gas from the system to empty cylinder, disconnecting all electrical connection, flair nuts, valves and shut down all preventive valves properly, supply and replace with new cooling coil as per existing size and specification including necessary fixing arrangement and electrical connection and safety protection devices to the existing system and flushing the whole system by nitrogen, leak testing by 200 PSI nitrogen pressure holding of 48 hours, charging of decanning refrigerent to the system and charging of additional refrigerent as required, commisioning and testing complete all as specified.
M&L for gas charging of refrigerant R-22/R-32/R-410A in window/split AC complete all as specified.
Supply and install in repair Stand / Heavy Duty for split Air Conditioner Outdoor Unit mounting bracket made up of Heavy Duty GI Steel ( For Maximum Strength ) Load Carring Capacity Upto 160 Kgs ( Best in Class ) all as specified.
S&F in repair metal clad AC plug top 32A, 230 volt complete all as specified
Material and labour for dismantling the cover of condensor and cooling coil, thoroughly cleaning the external surface (both side) of all the component including fins, base , discaling solution mixed up of chemicals, water etc with the help of air blower motor, wire brushing and reassemble all the components plate, runner, fan blade etc in original position as and when directed for refrigerator/deep freezer upto 315 ltrs capacity.
M&L for replacement of starting relay of refrigerator/deep freezer upto 315 ltrs capacity 315 ltr
M&L for replacement of capillary copper tube of size 0.36 mm of refrigerator/deep freezer upto 315 ltrs capacity
Disconnecting defective cooling coil of refrigerator/deep freezer upto 315 ltrs capacity and replacing the same with new cooling coil and fixing in original position as per existing one
Disconnecting defective condensing coil of refrigerator/deep freezer upto 315 ltrs capacity and replacing the same with new condensing coil and fixing in original position as per existing one
M&L for replacement of fan motor of refrigerator/deep freezer of any capacity.
M&L for replacment of 6/10 mfd running capacitor for compressor of refrigerator/deep freezer upto 315 ltrs capacity
M&L for replacement of 40/60 starting capacitor for compresor of refrigerator/deep freezer upto 315 ltrs capacity
M&L for replacement of 80/100 starting capacitor for compresor of refrigerator/deep freezer upto 315 ltrs capacity
M&L for replacement of thermostat of refrigerator/deep freezer upto 315 ltrs capacity
M&L for replacement of Inner lights of refrigerator/deep freezer upto 315 ltrs capacity
S&F in replacement of over load protector for refrigerator/deep freezer upto 315 ltrs capacity
M&L for replacement of AC single phase 230 volt PCB for refrigerator/deep freezer upto 315 ltrs capacity
Disconnecting electrically and mechanically refrigerator/deep freezer and taking down old unsv sealed compressor unit of refrigerator/deep freezer upto 315 ltrs capacity and replacement with new sealed unit of compressor of same size, type and capacity including connecting sealed unit and discharge pipe with gas weldind/soldering including gas charging complete all specified Note :- Compressor unit shall have one year replacement guarantee from date of installation.
M&L for dismantling the cover of condensor and cooling coil, thoroughly cleaning/servicing the external surface (both side) of all the component including fins, base , discaling solution mixed with chemicals, water etc with the help of air blower, wire brushing and reassemble all the components plate, runner, fan blade etc in original position as and when directed for water cooler upto 150 ltrs capacity
Taking down unserviceabe sealed compressor unit of water cooler upto 150 ltrs capacity and S&F in replacement new sealed compressor and connecting up suction and discharge copper pipe , gas filter, capillary etc with gas charging, welding and commissioning complete all as specified. Note :- Compressor/Sealed unit shall have one year replacement guarantee from date of installation.
M&L for leak testing of gas circulation system of water cooler upto 150 ltrs capacity and supply & charging of refrigerant Gas R-134A as per existing in entire system including supply and replacement of drier/filter and punching/providing dead plug complete all as specified.
M&L for gas charging of refrigerant R-134A/R-22 in refrigerator/deep freezer/Water Cooler complete all as specified and directed by Engr-In-Charge
M&L for replacement of fan motor of water cooler of any capacity.
S&F in repair PVC connection pipe 15mm dia and 90 cm length with PTMT nuts & washers at both ends for water connection of water coolers upto 150 ltrs capacity complete all as specified.
S&F in repair PVC drain pipe flexible heavy duty with necessary saddles and fittings for drain out water from water cooler complete all as specified.
S&F in replacement of fan blade for water cooler upto 150 ltrs capacity.
S&F in replacement of water tray stainless steel for water cooler upto 150 ltrs capacity.
M&L for replacement of 10/15 mfd running capacitor for Water Cooler upto150 ltrs capacity
M&L for replacement of 40/60 mfd starting capacitor for water cooler upto 150 ltrs capacity
M&L for replacement of 15mm bore chromium plated push cock as per existing shape suitable for water cooler upto150 ltrs capacity
M&L for replacement of thermostat for water cooler upto 150 ltrs capacity.
M&L for replacement of starting relay suitable for water cooler upto 150 ltrs capacity
M&L for replacement of over load protector suitable for Water Cooler upto 150 ltrs capacity
S&F in repair of AC DBOX alongwith MCB 20A SP complete all as specified and as directed
M&L in repair in repair/replacment submain wiring with two single core PVC insulated FRLS-H multistrand copper conductor cable of size 06 Sq mm drawn into PVC casing caping with ISI marked with all fittings / accessories and 04 Sq mm FRLS-H multistrand copper conductor cable as continuous earth wire and including colour coding of copper conductor ie for Phase-Red/Yellow/Blue, Neutral-Black and Earthing-Green colour complete all as specified. complete all as specified. Note :- Two run of single core cable and one run of earth wire will be measured as one length
Supply and fix in reapir Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 kVA Make:- V-Guard/Microtek/Turbo
Supply and fix in repair Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 kVA Make:- V-Guard/Microtek/Turbo
Supply and fix in repair Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 kVA Make:- V-Guard/Microtek/Turbo
S&F in replacement, split AC indoor unit 1.5 Ton capacity duly matching with the existing outdoor unit complete all as specified and directed by Engr-in-Charge.
S&F in replacement, split AC outdoor unit 1.5 Ton capacity duly matching with the existing indoor unit complete all as specified and directed by Engr-in-Charge.
Lucknow Refrigeration (BID ID -3454363)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
TENDERDOCS.pdf
Tender Documents • 0.83 MB
BOQ_818362.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .