| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.1 LAccepted-AOC | ₹98.1 L Quoted ₹98.4 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.1 Cr+₹10.3 L (10.5%)Rejected-AOC 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹1.1 Cr+₹10.3 L (10.5%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹1.1 Cr+₹11.9 L (12.0%)Rejected-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | ₹1.1 Cr+₹11.9 L (12.0%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹1.1 Cr+₹15.7 L (15.9%)Rejected-AOC | ₹1.1 Cr+₹15.7 L (15.9%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹1.2 Cr+₹19.5 L (19.8%)Rejected-AOC | ₹1.2 Cr+₹19.5 L (19.8%) | L5 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
10 Jun 2021, 6:00 pmClosed
CE R and D Secunderabad
CE R and D Picket Opp Jublee bus station Secunderabad
REPAIR REPLACEMENT OF CENTRAL PACKAGE AC PLANT AGAINST SPECIAL REPAIR BER DRDL COMPLEX UNDER GE I R AND D KANCHANBAGH HYDERABAD
2021_MES_438529_1
CA NO.CERD/SEC/TOKEN/17 OF 2020 -2021
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
HYDERABAD
As per NIT
7 documents required · 7 mandatory
₹1,000
GE I R and D Kanchan bhag
₹2.0 L
Yes
19 Jul 2021
26 Apr 2021
15 Jun 2021
26 Apr 2021
10 Jun 2021
12 May 2021
Amount
Supply, installation, testing & commissioning of central air conditioning plant of water cooled scroll chillers with multiple scroll compressors, water cooled condenser shell and tube, chiller working on Ozone friendly R-410a/R-407c, capacity not less than 3x32TR (2x32TR working and 1x32TR standby) complete to achieve the inside temperature 22 + 2⁰C and RH 55 + 5% with and including the provision of following equipments and accessories, complete all as specified and directed. (i) Water cooled chiller package comprising of multi-compressors with automatic slide wall-03 Nos (02 Working and 01 Standby) each driven with inbuilt electric motor operating on 400Volts + 10%, 50Hz, 3 Phase AC supply with in-built BMS compatible microprocessor control panel with fault diagnostics including all safety control complete with suitable capacity contactors duly pre-wired and interconnected water cooled shell and tube condensers, oil and refrigerant charged chiller of suitable capacity as directed by OEM including interconnection of refrigeration line and control and accessories with independent circuits, mounted and assembled on common base frame MS sections of suitable capacity as per OEM recommendations with anti vibration pads, complete all as specified and directed.
Make: Blue Star / Voltas / Daikin / Hitachi. Note: The ratings are based on 44⁰F, chilled water inlet and outlet temperature of 7⁰C and 12⁰C with fouling factor of 0.0001FPS and condenser water inlet and outlet temperatures of 30⁰C and 35⁰C with fouling factor of 0.00025FPS. (ii) Civil works such as modification to existing foundation or provision of new foundation in PCC 1:3:6, making good the disturbed surfaces etc are deemed to include in quoted rate. (iii) Perforated GI sheet cable tray of width as per the cable size and runs duly fixing on angle iron supports grouted in walls for carrying all cables. (iv) Any Item of work not included in above details, but is inescapable, technical requirement for the above AC plant performance and smooth functioning of the plant shall be clearly specified and it should be included in the rate quoted.
Supply, installation, testing & commissioning of factory made chilled water monoblock end suction short coupled pump - 3 nos (2 working + 1 standby) with TEFC squirrel cage motor, base frame, vibration rubber pad, for the chilled water working on 3 phase, 415Volts, 50Hz , 100% capacity with bronze impeller capable of discharging not less than 115 USGPM - primary pump including foundation as per OEM recommendations complete all as specified and directed. Make: Kirlosker / Crompton Greaves / Grundfoss.
Supply, installation, testing & commissioning of factory made condenser water monoblock end suction short coupled pump - 2 nos (1 working + 1 standby) with TEFC squirrel cage motor, base frame, vibration rubber pad, for the chilled water working on 3phase, 415Volts, 50Hz , 100% capacity with bronze impeller capable of discharging not less than 256 USGPM at 30m head - primary pump including foundation as per OEM recommendations complete all as specified and directed. Make: Kirlosker / Crompton Greaves / Grundfoss. Note for Item Nos 2 & 3: Quoted rates are deemed to include neccesary MS channel base frame for installing the pumps as required at site.
Condenser water piping of MS "C" Class cut to required length and installed with welded joints including all necessary fittings such as elbows, tees, bends, short pieces etc and conforming to the specifications and painting with one coat of red oxide primer and two coats of synthetic enamel paint of colour as approvedcomplete including providing necessary steel supports, complete all as specified and directed. The pipes shall be of the following sizes: - Make: TATA/ Zindal / Ispat
125mm dia
100mm dia
Chiller water piping of MS "C" class cut to required length and installed with welded joints including all necessary fittings such as elbows, tees, bends, short pieces etc and conforming to the IS specifications and painting with one coat of red oxide primer and two coats of synthetic enamel paint of approved colour, complete including providing necessary steel supports, also including pipe insulation with 50mm thick 48 Kg/cum density IF polystyrene with 26 gauge aluminium cladding sheet complete all as specified and directed. The pipes shall be of the following sizes: - Make: TATA / Zindal / Ispat.
100mm dia
65mm dia
Balancing valves of size 100mm dia complete with companion flanges, nuts, bolts, washers and gaskets etc., conforming to relevant IS complete all a specified and directed.
Balancing valves of size 65mm dia complete with companion flanges, nuts, bolts, washers and gaskets etc., conforming to relevant IS complete all a specified and directed.
Water flow switch suitable for the 65 mm dia size complete all as specified and directed. Make: Siemens / Honeywell.
Ball valve for drain and air removal 20 mm size complete all as specified and directed. Make: Zoloto / Audco.
Required auto air vents in the chiller pipe line of suitable size as required at site complete all as specified and directed.
3 way modulating valve for AHUs for the size 100 mm dia complete with all accessories & all as per manufacturer design complete all as specified and directed. Make: Siemens / Honeywell / Rapid controls.
Butterfly valves in the chiller water pipe line for the size of 100mm dia with necessary special fittings and supports duly insulated complete with all accessories & all as per manufacturer design complete all as specified and directed. Make: Saint / Audco / Castle.
Butterfly valves in the chiller water pipe line for the size of 65mm dia with necessary special fittings and supports duly insulated complete with all accessories & all as per manufacturer design complete all as specified and directed. Make: Sant / Audco / Castle.
Non-return valves of size 65mm dia complete with companion flanges, nuts, bolts, washers and gaskets etc conforming to relevant IS, complete all as specified and directed. Make: Sant / Audco / Castle.
Butterfly valves in the condenser water pipe line for the size of 100 mm dia with necessary special fittings and supports complete with all accessories & all as per manufacturer design complete all as specified and directed. Make: Sant / Audco / Castle.
Butterfly valves in the condenser water pipe line for the size of 125 mm dia with necessary special fittings and supports complete with all accessories & all as per manufacturer design complete all as specified and directed. Make: Sant / Audco / Castle.
Y-strainer duly insulted for chilled water pipe lines of size 65mm dia with necessary special fittings and supports complete with all accessories all as per the manufacturer design complete all as specified and directed .Make: Sant /Kartar/ Audco / Castle.
Y-strainer for condenser water pipe lines of size 100mm dia with necessary special fittings and supports complete with all accessories all as per the manufacturer design complete all as specified and directed.
Dual plate check valve of size 65 mm dia in the condenser water pump discharge line with necessary special fittings and supports complete with all accessories & all as per manufacturer design complete all as specified and directed .Make: Sant / Kartar/Audco / Castle.
Dual plate check valve of size 100 mm dia in the chilled water pump discharge line duly insulated with necessary special fittings and supports complete with all accessories & all as per manufacturer design complete all as specified and directed.
Rubber expansion joints for chillers and pumps of size 100 mm dia with necessary special fittings and supports complete with all accessories & all as per manufacturer design complete all as specified and directed.
Dial type pressure gauges in the chiller & AHU water pipe line complete with all fittings and gun metal valves for isolation for ease of maintenance and operation all as per manufacturer design complete all as specified and directed. Make: H Guru.
Dial type temperature gauges of 100mm dia in the chiller & AHU water pipe line complete with all fittings and gun metal valves for isolation for ease of maintenance and operation all as per manufacturer design complete all as specified and directed. Make: H Guru.
Dial type temperature gauges of 80mm dia in the chiller & AHU water pipe line complete with all fittings and gun metal valves for isolation for ease of maintenance and operation all as per manufacturer design complete all as specified and directed. Make: H Guru.
Supply, installation, testing make up tank of PVC including 50 mm thick of 48Kg/Cum density TR expanded polystyrene insulation, expanded polyesterene pre formed pipe sections and26 gauge aluminium cladding with top side access door - 500 ltr capacity incuding Brass float valve (CHILLED WATER MAKE UP) complete all as specified and directed.
Supply, installation, testing PVC make up tank incuding Brass float valve of with top side access door - 2000 ltr capacity (CONDENSOR WATER MAKE UP) complete all as specified and directed.
Supply, installation, testing and commissioning of sectionalised construction double skin draw thru type air handling unit suitable for chilled water system made out of extruded aluminum structural frame / aluminium corners and intermediate connecting places and panels of 06mm thick galvanised steel sheet on both sides with 25mm thick PUF of density (38 + 2) kg/cn.m injected panels having pre-painted panel outside and laid inside the panel.The fan section shall be mounted on anti-vibration spring isolators and free from main structure, the fan shall be backward curved centrifugal fan with air discharge upbase, blower housing , belt driven with induction motor conforming IE-2 specifications of suitable capacity. The coil section shall consist of 06 row deep coil with minimum 12 fins/inch . The filter sections consits of pre-filter with 10micorn,fine filter with 5 micron 95% efficiency. The other accessories are view port, limit switch, stainless steel drain pan volume control damper, 75mm static pressure with energy efficient motor of suitable capacity. AHU shall be provided with UVC emitters and fixtures in sufficient quantity so as to provide equal distribution of UVC energy on the coil and in the drain pan as per the specifications of capacity: 29600CFM @ 65 mm static WG all as specified and directed. Make: Zeco / Sagar Air / Voltas / Edgetech.
Pan type humidifier comprising of stainless steel pan with 6KW heater, wiring, water piping GI pipe medium grade 15mm bore and 100Ltr rotational moulded polyethylene loft tank including provision of float valve and brass stop cock and inlet pipe, all of suitable size complete all as specified and directed.
Strip heater bank not less than 6KW (in three banks of 2KW each)including suitable starter panel with Auto/ manual controls and necessary copper conductor wiring for banking complete all as specified and directed.
Humidistat and Thermostat in AHU room for controlling humidifier & strip heater neccesary control wiring as per the OEM recommendations, complete all specified and directed.
Supply, installation, testing and balancing of air distribution system consists of factory fabricated as per IS-655 galvanised iron sheet zinc coating 120 grade as per IS-277 metal ducting with TDF flanges complete with 4mm thick self adhesive neoprene rubber gasket, stiffeners, elbows, splitters, vanes, bolts, nuts and including provision of mild steel angle iron frames for fixing of ducts, supports duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed of the following sizes: - Note: The size and layout of duct shall be approved by the accepting officer before execution.
20 gauge.
22 gauge.
24 gauge.
Supply & installation of thermal insulation of air ducting with 12 mm thick closed cell Nitrile rubber insulation of density minimum 43kg/m3, anti-microbial with EPA approved and fire performance to pass and suffixed using synthetic contact adhesive of approved make, complete all as per specifications and approved drawings, complete all as specified and directed. Make: Supreme / K-flex.
Supply, installation, testing and commissioning Acoustic insulation of supply air ducting with 19mm thick OPEN cell electrometric nitrile rubber with density minimum 43kg/m3, anti - microbial with EPA approved and fire performance to pass, class - 1 as per BS 476 Part-7 and class O as per BS 476 Part 6 and use recommended adhesives / SR 505 grade Fevicol and covered with 7mm thick chemically treated woven glass cloth having density 205 + 10gram / sqm and affixed using synthetic contact adhesive of approved make complete all as per specifications and approved drawings complete all as specified and directed.
Supply, installation, testing and commissioning of fire dampers automatic type with fusible link (CPRI Certified) and operated with stainless steel spring made out of 16SWG GI sheet to be provided in main supply duct interlocked with AHU motor to cut-off circulation of air in case of fire for each AHU complete all as specified and directed. Make: System Air / Navjyoti Airflow / Sagar air / Breeze air.
Supply, installation, testing and commissioning of multi-blade type louver volume control damper of GI sheet for collars shall be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution complete all as specified and directed.
Supply, installation, testing and commissioning alluminium powder coated fresh air grill with MS powder coated volume control dampers of size as per the site requirement confirming complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required galvanised iron or steel wire 32x6mm galvanised iron strip all as specified and as directed.
S&F, earth continuity conductor of size 4mm dia GI earth lead wire complete all as specified and directed.
Supply, lay, testing and commissioning in trenches / fixed to walls / poles etc, XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 3.5 Core 50 Sqmm complete all as specified and as directed. Note: Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item No. 40 above, but 3.5 Core 25 Sqmm for AHU.
All as per item No. 40 above, but 4 Core 10 Sqmm for PUMP.
All as per item No. 40 above, but 3.5 Core 35 Sqmm.
Supply, install, test and commissioning of air cooled package type air conditioner not less than 11 TR capacity with single/twin compressor, weather proof with hermetically sealed scroll compressor air cooled type, operating on R-410a/R-407c refrigerant to achieve the inside temperature 22° ± 2°C with RH of 55 ± 5%, comprising of all standard things and accessories along with microprocessor panel, protection relays, cooling coil, centrifugal blower fan condenser in built, thermal protector, internal pressure relief valves, HP/LP cut outs, complete connected electrical wiring and connection from the main and necessary civil work for foundation of package unit with necessary bolts and nuts grouted suitable to operate on 3-phase, 415V, 50Hz (each package unit shall comprise of scroll compressor - 11 TR capacity, hermetically sealed type directly coupled with refrigerant cooled screen protected drip proof induction motor with necessary starter automatic modulating capacity with thermostat), outdoor condenser consists of air cooled condenser single / three phase suitable capacity of electrically driven motor and each compressor separate condenser with internally grooved high efficiency copper tube with aluminium fins for higher efficiency heat exchange, evaporator coil of suitable size with DX coil of two circuit including suitable size of expansion valves and blower of minimum delivery 3500CFM with belt drive including suitable capacity of 3-phase electric driven motor with corded remote control in conditioned area complete all as specified and directed. Make: BLUE STAR / VOLTAS / CARRIER.
Supply, connecting, testing and commissioning hard drawn copper refrigerant piping of suitable size as rwcommended by OEM with insulation connecting Indoor package unit and outdoor condenser units including bending to the shape as required at site and brazing the pipes, testing for leakages complete all as specified and directed.
S&F PVC drain pipe of size 20mm from the dehumidifier pan to the drain hole including necessary fixing spares complete all as specified and directed.
Supply, install, test and commissioning of air cooled package type air conditioner of capacity not less than 9 TR capacity with single/twin compressor, weather proof with hermetically sealed scroll compressor air cooled type, operating on R-410 refrigerant to achieve the inside temperature 22° ± 2°C with RH of 55 ± 5%, comprising of all standard things and accessories along with microprocessor panel, protection relays, cooling coil, centrifugal blower fan condenser in built, thermal protector, internal pressure relief valves, HP/LP cut outs, complete connected electrical wiring and connection from the main and necessary civil work for foundation of package unit with necessary bolts and nuts grouted suitable to operate on 3-phase, 415V, 50Hz (each package unit shall comprise of scroll compressor - 9 TR capacity, hermetically sealed type directly coupled with refrigerant cooled screen protected drip proof induction motor with necessary starter automatic modulating capacity with thermostat), outdoor condenser consists of air cooled condenser single / three phase suitable capacity of electrically driven motor and each compressor separate condenser with internally grooved high efficiency copper tube with aluminium fins for higher efficiency heat exchange, evaporator coil of suitable size with DX coil of two circuit including suitable size of expansion valves and blower of minimum delivery 3500CFM with belt drive including suitable capacity of 3-phase electric driven motor with corded remote control in conditioned area complete all as specified and directed. Make: BLUE STAR / VOLTAS / CARRIER.
Supply & installation of acoustic insulation of air ducting with 25 mm thick open cell Nitrile rubber Insulation of density minimum 140kg/m3, anti- microbial with EPA approved and fire performance to pass and suffixed using synthetic contact adhesive of approved make, complete all as per specifications and approved drawings, complete all as specified and directed. Make: Supreme / K-flex.
Supply and installation, testing and commissioning thermal insulation of supply air ducting with 9mm thick closed cell elastrometric nitrile rubber with density minimum 43kg/m3, anti - microbial with EPA approved and fire performance to pass, class - 1 as per BS 476 Part-7 and class O as per BS 476 Part 6 and use recommended adhesives / SR 505 grade fevicol and covered with 7mm thick chemically treated woven glass cloth having density 205 + 10gram / sqm and affixed using synthetic contact adhesive of approved make and covered with 24G aluminium cladding for all exposed ducts, complete all as per specifications and approved drawings complete all as specified and directed.
Supply & installing aluminium powder coated supply air grill with control dampers complete all as specified and directed.
Supply & installing aluminium powder coated return air grills complete all as specified and directed.
Supply & installing back dampers for package units complete all as specified and directed.
Supply & installing volume control dampers for supply ducts complete all as specified and directed.
S&F canvass connection complete all as specified and directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below normal ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip 32mm x 6mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C2 earth chamber, CI pit cover including disposal of surplus soil to a distance not exceeding 50metre etc., and connected to earthing test point complete including testing on completion, complete all as shown in electrical plate No. 3 of MES Schedule Part - I and all as specified and directed.
Strip heater 9 KW for AC plant provided under Sl. Item No. 44.00 here-in-before, for controlling humidity with in 55 ± 5% by automatically switching on the strip heaters in 4-steps and including necessary control panel, sufficient number of power contactors, MCB's for controlling step humidity sensors etc., complete all as per OEM recommendations. The heaters shall be fixed to the supply air duct plenum with suitable inspection door, copper cable of suitable size from the heater to the control panel, complete all as specified and directed.
Strip heater 6KW for AC plant provided under Sl. Item No. 47.00 here-in-before, for controlling humidity with in 55 ± 5% by automatically switching on the strip heaters in 4-steps and including necessary control panel, sufficient number of power contactors, MCB's for controlling step humidity sensors etc., complete all as per OEM recommendations. The heaters shall be fixed to the supply air duct plenum with suitable inspection door, copper cable of suitable size from the heater to the control panel, complete all as specified and directed.
FRP induced draft cooling tower of 80 TR capacity, bottle type, complete with spray section honey comb fill basim fan, TEFC motor, intake bird screen and other accessories as required with and including provision of suitable birck work staging with PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation and excavation to the required size in any strata, provision of ladder etc., complete all as specified and directed. Note: (i) Inlet and outlet PPR pipes of suitable size as per the OEM recommendations with control valves from nearest tapping point for cooling tower shall deemed to be included in rate quoted. (ii) 1 x 80 TR (one working and one standby).
CENTRAL AC PLANT AT OLD PPC BLDG (SPECIAL REPAIR) Dismantling carefully the open type compressor of SMC 6-65, make ACCEL of 20 TR capacity for complete overhauling of compressors and replacing all defective mechanical spares, control spares and replacing all gaskets and re-assembling all compressor parts after repairs and refilling the compressor oil and testing the compressors for any leakages, testing and commissioning of compressors to the entire satisfaction of the Engineer-in-Charge. Note: Required spare parts less than amount of Rs.200/- and are inescapable for functioning of compressor deemed to be included in the quoted rates. (ii) The spares required to be replaced during overhauling will be measured and paid separately under resp Schedule 'A' items.
All as per Sl item No. 59 above, but SMC 4-100. Make: ACCEL of capacity 40TR.
Supply only, the following spares required for overhauling of the compressors of capacity 20TR, Model: SMC 6-65 Make: ACCEL.
Main bush
Crank shaft
Half section bearings
CR bushes
Gurden pin / Bush pins / Piston pins
Ring set
Shaft seal complete
Oil pump
Oil pump coupler
Thrust washer
Suction strainer
Oil filter
Aluminium 'O' ring set
Rubber 'O' ring set
Pistons
Liner
Suction stop valve complete
Discharge stop valve
Suction and discharge reed set
Frame for loading mechanism complete
Oil capacity regulator
Connecting rods
Supply only, the following spares required for overhauling of the compressors of capacity 40TR, Model: SMC 4-100 Make: ACCEL.
Crank shaft
Oil pump
Connecting rods
Pistons
Liner set
Main bearing bush
CR bearings
CR bushes
Gagin pin
Gagin pin locks
Ring set
Gas kit set
Suction reed
Discharge reed
Discharge valve
Oil filter
Shaft seal assembly
Rocker frame
Rocker frame
Rocker spring
Rocker PIN
Rocker cup
Stainer filter
Stainer
Loader
Capacity control valve
Aluminium 'O' ring set
Rubber 'O' ring set
Pressure release valve
Dismantling carefully the semi hermetic type compressor of 30TR capacity Model: 299610 Make: Carrier complete overhauling of compressors and replacing all defective mechanical spares, control spares and replacing all gaskets and re-assembling all compressor parts after repairs and refilling the compressor oil and testing the compressors for any leakages, testing and commissioning of compressors to the entire satisfaction of the Engineer-in-Charge. Note: Rates are deemed to include replacement of all defective mechanical parts, mechanical spares, rewinding of compressor motors, replacing oil filters and core filters.
Supply, installation, testing & commissioning of factory made chilled water monoblock end suction short coupled pump - 1 No with TEFC squirrel cage motor, base frame, vibration rubber pad, for the chilled water working on 3 phase, 415Volts, 50Hz , 100% capacity with bronze impeller capable of discharging not less than 84 USGPM at 30 m head - Primary pump including foundation as per OEM recommendations complete all as specified and directed. Make: Kirlosker / Crompton Greaves / Grundfoss.
Disconnecting and taking out the control panel of the air cooled chilled water semi hermetic compressor of capacity 30TR Model: Model: 06E 6 299610, Make: Carrier, identifying the defective spares and servicing the entire panel, removing all defective spares, wiring and PCB and replacing the defective contactors, switch gears, wiring etc. The job includes necessary repairs of the PCB and replacing any spares of PCB as specified by the OEM for its full working conditioning and servicing and repairs to the PCB through authorised technician and testing the complete unit for all its working conditioning after completing job for its proper functioning to the entire satisfaction of the Engineer-in-Charge. Note: (i) The entire job should be carried out through authorised technicians / service team. (ii) The Spares required for making the control panel working are deemed to be included in the quoted rates.
S&F in repairs pressure transducers for suction and discharge lines suitable as per the existing model all as specified.
S&F in repairs temperature sensors for suction and discharge lines suitable as per the existing model all as specified.
S&F in repairs compressor timer suitable as per the existing model O6E-299610E all as specified.
S&F in repairs compressor heater suitable as per the existing model all as specified.
Taking out the damaged / condenser coil carefully and supply and fixing new condenser coil in repairs of capacity 30TR for air cooled type chiller of Make: Carrier, Model: 06E 6 299610 as per the existing coil specifications. Note: Quoted rates should includes transporting of new cooling coil from the factory to the site.
Scrapping the old paint completely without damaging any parts and applying one coat of primer and two coat of spray painting the entire body including base with super enamelled paint of color as approved by the Accepting Officer complete all as specified and directed.
Repairs Y-Strainer of 80mm dia IS confirming complete all as specified and directed.
Taking down compressor motor (30-35) KW 3 phase 415 volts 50 Hz 1455 RPM cutting & removing the burnt winding, rewinding with same gauge of super enamelled copper conductor, insulating materials etc and varnishing the winding, replacing the worn out bearings complete as per the OEM data & specifications and reassembling connecting testing and commissioning complete to the entire satisfaction of the Engineer-in-Charge, complete all as specified and directed.
Opening of the existing monoblock pump set and servicing by cleaning all dust, carbon including greasing for the bearing and replacement gland and bearing as per existing sizes complete for 7.5HP capacity complete all as specified and directed.
PVC fins suitable to make of cooling tower MIHIR / PAHARPUR as required at site complete all as specified and directed.
Removing of the existing unserviceable spray nozzles from the cooling tower and supply and fix new PVC spray nozzles suitable for PAHARPUR make cooling tower of 120 TR capacity complete all as specified and directed.
Removing the existing unserviceable cooling tower fan assembly and supply & fix new cooling tower fan assembly complete with shaft hub and including pully and key suitable for 3 x 40 TR capacities cooling tower and testing, complete all as specified and directed.
Disconnecting and taking out the existing old unserviceable water sensor and supply and fix water sensor for entering and leaving water temperature suitable for 2 x 30 TR capacity compressor of (Voltas / Carrier Make) chiller type AC plant and testing complete all as specified and directed.
Disconnecting and taking out the existing old unserviceable water sensor and supply and fix water sensor for entering and leaving water temperature suitable for 3 x 20 TR capacity compressor of (Voltas / Carrier Make) chiller type AC plant and testing complete all as specified and directed.
Disconnecting and taking out the existing old unserviceable water sensor and supply and fix water sensor for entering and leaving water temperature suitable for 3 x 40 TR capacity compressor of (Voltas / Carrier Make) chiller type AC plant and testing complete all as specified and directed.
Expansion valve suitable for 30 TR capacity AC plants of make Sporlon / Sunlam or its equivalent complete all as specified and directed.
Expansion valve suitable for 40 TR capacity AC plants of make Sporlon / Sunlam or its equivalent complete all as specified and directed.
Removing the existing unserviceable liquid line filter drier and supply & fix new liquid line filter drier for use with CFC / HCFC / HFC / R22 / R134a / R407c complete and key suitable for 1x30 TR capacities of AC plants and testing complete all as specified and directed.
Compressor oil of Servo Bharat Freezol N-68 complete all as specified and directed.
Supply & fix in repairs industrial type temperature gauge of range 20⁰F to 120⁰F with 2degree scale divisions suitable for chilled water lines duct mounting type with not less than a 12" stem complete all as specified and directed.
Supply & fix in repairs in position industrial type pressure gauages dial type with gun metal valves for isolation and necessary fittings of range 0 to 30 psi in the liquid lines complete all as specified and directed.
Top up refrigerant gas R-22 complete all as specified and directed. Make: Mafron / Floron.
Leak testing of the AC plant with nitrogen (N2) pressure after evacuating of the existing gas from the system into empty cylinder by separating the entire system, like compressors, evaporator, condensers, cooling coil and refrigerant lines and rectifying the leakage including cutting welding brazing etc and replacing of 'O' ring, washers, gaskets etc flushing out the nitrogen and vaccumising, recharging the taken out refrigerant gas including testing complete all as directed to AC plants of 2x30 TR capacities.
Leak testing of the AC plant with nitrogen (N2) pressure after evacuating of the existing gas from the system into empty cylinder by separating the entire system, like compressors, evaporator, condensers, cooling coil and refrigerant lines and rectifying the leakage including cutting welding brazing etc and replacing of 'O' ring, washers, gaskets etc flushing out the nitrogen and vaccumising, recharging the taken out refrigerant gas including testing complete all as directed to AC plants of 3x20 TR capacities.
Leak testing of the AC plant with nitrogen (N2) pressure after evacuating of the existing gas from the system into empty cylinder by separating the entire system, like compressors, evaporator, condensers, cooling coil and refrigerant lines and rectifying the leakage including cutting welding brazing etc and replacing of 'O' ring, washers, gaskets etc flushing out the nitrogen and vaccumising, recharging the taken out refrigerant gas including testing complete all as directed to AC plants of 3x40 TR capacities.
Descaling of one condenser unit of following capacity of AC plants of any make / type with and including descaling compound DC-98 by using rotary type scaling cutter and brushes in stages as required to remove complete scales from all copper tubes till achieve the desired pressure including renewing of gaskets, nuts, bolts and washers etc. and testing all as specified and directed to 3x20 TR capacity AC plant.
Descaling of one condenser unit of following capacity of AC plants of any make / type with and including descaling compound DC-98 by using rotary type scaling cutter and brushes in stages as required to remove complete scales from all copper tubes till achieve the desired pressure including renewing of gaskets, nuts, bolts and washers etc. and testing all as specified and directed to 3x30 TR capacity AC plant.
Descaling of one condenser unit of following capacity of AC plants of any make / type with and including descaling compound DC-98 by using rotary type scaling cutter and brushes in stages as required to remove complete scales from all copper tubes till achieve the desired pressure including renewing of gaskets, nuts, bolts and washers etc. and testing all as specified and directed to 3x40 TR capacity AC plant.
Removing the unserviceable V-Belts of sizes B-124 / B-108 / B-90 from the system and supply and fix V-Belts of following sizes and testing and complete all as specified and directed.
Removing the unserviceable V-Belts of sizes C-110 / C-108 / C-90 from the system and supply and fix V-Belts of following sizes and testing and complete all as specified and directed.
Dismantling the burnt out upto 7.5 HP motor rewinding with copper winding suitable gauge and repair / replacement of the following items, pully belt, blower fan blade, blower motor bearing, AHU micro fins and connected items etc., after completion of work all AHU unit tested by in front of Engineer-in-Charge complete all as specified and directed.
MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA, thermal magnetic with adjustable over current & short circuit ratings complete all as specified and directed.
GI perforated cable trays made with high grade strength sheet steel having minimum thickness of 1.6mm of width 200 mm and height not less than 25mm and depth as per the site requirement and fixing on angle supports or threaded rods suspended from ceilings as required at site complete all as specified and directed.
Structural steel sections such as angles, flat, channels as in bands, straps, supports or stays for chiller pipes, including nuts, bolts, washers as required, including welding, bending cold or hot etc., drilling holes for bolts in any size and shape with and including painting with two coat of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces; steel sections conforming to Fe-290 Gde-E-165, complete all as specified and directed.
Leo Air and Power Solution pvt Ltd.
omsai thermax engineers
BRITE INDUSTRIES
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .