| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹46.7 L+₹6.4 L (15.7%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹47.7 L+₹7.4 L (18.3%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹49.5 L+₹9.2 L (22.8%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹49.7 L+₹9.3 L (23.1%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L5 | Rejected-Finance Being higher bid value |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
6 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8970/E8
2021_MES_468471_1
GE/ALP (8970) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
270 days
GE ALIPORE KOLKATA
Class D and Category b i
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹74,000
Yes
11 Nov 2021
16 Aug 2021
7 Sept 2021
16 Aug 2021
6 Sept 2021
30 Aug 2021
60 days
Amount
Material and labour in repair for point wiring for one light/fan/call bell point with single core 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including single core 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including rigid nonmetalic PVC conduit pipe of appropriate size, medium grade, surface type with all accessories medium grade and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick bakalite sheet cover or for fixing of modular switch socket as per site requirement after and including taking down of old existing point wiring including fitting and making good the distrubed surfaces as per the existing complete all as specified and as directed.
All as per item No 1 here-in-before but for 3 pin 6 Amps socket outlet on the same board with single core 1.5 sqmm cable complete as specified and directed.
All as per item No 1 here-in-before but for 3 pin 6 Amps switch socket combination on the independent board with single core 1.5 sqmm cable complete as specified and directed.
All as per item No 1 here-in-before but for switch socket combination 2 in 1,3 pin 5/15 Amp on independent board with 2.5 Sqmm PVC unsheathed copper cable and 1.5 sqmm copper conductor cable as earth continuity conductor complete as directed.
Material and labour in repair for point wiring for one light/fan/call bell point with single core 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including single core 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through PVC Casing & capping with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick bakalite sheet cover or for fixing of modular switch socket as per site requirement after and including taking down of old existing point wiring including fitting and making good the distrubed surfaces as per the existing complete all as specified and as directed.
All as per item No 5 here-in-before but for 3 pin 6 Amps switch socket combination on the independent board with single core unsheathed 1.5 sqmm cable complete as specified and directed.
All as per item No 5 here-in-before but for switch socket combination 2 in 1,3 pin 5/15 Amp on independent board with single core 2.5 Sqmm PVC unsheathed copper cable and 1.5 sqmm copper conductor cable as earth continuity conductor complete as directed.
Material and labour for point wiring in repair for one light/fan/bell point with single core 1.5 sqmm PVC insulated unsheathed copper cable (FRLSH) multistrand conductor 1100 volts grade controlled by one way switch including single core 1.5 sqmm PVC insulated unsheathed copper cable (FRLSH) multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC nonmetalic rigid conduit concealled with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick plastic laminated sheet cover complete including chase cutting and makng good of disturbed surface all as specified and directed.
All as per item No 8 here-in-before but for 3 pin 6 Amps switch socket combination on the independent board with single core unsheathed 1.5 sqmm cable complete as specified and directed.
All as per item No 8 here-in-before but for switch socket combination 2 in 1,3 pin 5/15 Amp on independent board with 2.5 Sqmm PVC unsheathed copper cable and single core unsheathed 1.5 sqmm copper conductor cable as earth continuity conductor complete as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.all as specified and directed by Engr-in- Charge
S & F in repair socket outlet 2 in 1, 5 pin 5 Amp,230 Volts flush type. Make: Anchor Cat No: 38342 or equivelent make
M & L in repair for switch socket combination 2 in 1, 5 pin 5 Amps, 240 V Flush type, all as specified. Make - Anchor Cat No: 38820 or equivelent make
Supply and fix in repair switch socket combination 2 in 1,5/15 Amps, 230 Volts, flush type universal complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing in repair switch piono, flush type 5 Amps 230 Volt single pole, one way complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing in repair ceiling rose surface bakelite three terminal 65 x 50mm, PVC/Polycarbonate,isolated body complete all as specified and as directed by the Engr-in-Charge.
Supply & fixing in repairs main stream battens fitting LED 10 watt tube 2 feet long 100 lumen/watt output fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block all as directed. Make: Century/ Jaquar/Crompton/Surya /Philips or equivalent of other make.
Supply & fixing in repairs main stream battens fitting LED 20 watt tube 4 feet long 100 lumen/watt output fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block all as directed. Make: CenturyJaquar/Crompton/Surya /Philips or equivalent of other make.
Supply & fixing in repairs main stream battens fitting LED 36 watt 2 ft X2 ft slim panel 110 lumen /watt output inbuilt driver 110 lumen/watt output suitable for fixing existing surface complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block all as directed. Make: Crompton Cat No.CCR-127-36-57-SL-NWH or equivalent of CenturyJaquar/Crompton/Surya /Philips
Taking down old LED light fitting and keep serviceable and Refixing on same place after checking all with fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block all as directed
Supply and fixing in repair sub-main wiring (surface type) for main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 10 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 10sq mm PVC (FRLS) insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through and including PVC Conduit carefully and taken down old existing aluminium sub main wiring with accessories complete all as directed by the Engr-in-Charge. Note : Two runs of 10 sqmm and one run of 10sqmm cable and one run PVC conduit shall constitute one unit.
Supply and fixing in repair sub-main wiring (surface type) for main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 6 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 6 sq mm PVC (FRLS) insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through and including PVC Conduit carefully and taken down old existing aluminium sub main wiring with accessories complete all as directed by the Engr-in-Charge. Note : Two runs of 6 sqmm and one run of 6 sqmm cable and one run PVC conduit shall constitute one unit.
Supply and fixing in repair sub-main wiring (surface type) for main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 4 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 4 sq mm PVC (FRLS) insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through and including PVC Conduit carefully and taken down old existing aluminium sub main wiring with accessories complete all as directed by the Engr-in-Charge. Note : Two runs of 4 sqmm and one run of 4 sqmm cable and one run PVC conduit shall constitute one unit.
Supply and fixing in repair sub-main wiring (surface type) for main DB's to sub DB's with PVC (FRLSH) insulated & unsheathed two runs of 1.5 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 1.5 sq mm PVC (FRLSH) insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through and including PVC Conduit carefully and taken down old existing aluminium sub main wiring complete all as directed by the Engr-in-Charge. Note : Two runs of 1.5 sqmm and one run of 1.5 sqmm cable and one run PVC conduit shall constitute one unit.
Supply and Fixing in replacement MCB, single pole, 240 Volts, of capacity (6-32 Amps) 'C' series breaking capacity 10 KA. Make legrand or equivalent grading ISI marked.
Supply and fixing in repair MCB SPN, 16 to 32 Amps, 240 Volts , breaking capacity 10KA complete all as directed. Make-legrand or equivalent grading marked.
Supply and fixing in repair MCB TPN 63 Amps, 415 Volts , breaking capacity 10KA complete all as directed. Make-legrand or equivalent grading marked.
Supply and fixing as in repair MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.
Supply and fixing as in repair MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.
Supply and fixing as in repair MCB DB SPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.
Supply and fixing as in repair MCB DB SPN (double door) 2 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.Make-HPL or equivalent grading ISI marked.
Supply and fixing as in repair MCB DB TPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.make HPL or equivalent of other make
Supply and fixing as in repair MCB DB TPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, MCCB/MCB as incomer and MCB as outgoing recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.make HPL or equivalent of other make
Supply and fixing in repair MCCB 4Pole 25-100Amps, 415 Volts , breaking capacity 16KA including nut bolts lugs & cable of suitable size complete all as directed. Make-legrand or equivalent grading marked.
Supply and fixing in repair MCCB 4Pole 160Amps, 415 Volts ,Adjustable type breaking capacity 35KA including nut bolts lugs & cable of suitable size complete all as directed. Make-legrand or equivalent grading marked.
Supply and fixing in repair MCCB 4Pole 200Amps, 415 Volts ,Adjustable type breaking capacity 35KA including nut bolts lugs & cable of suitable size complete all as directed. Make-legrand or equivalent grading marked.
Supply and fixing in repair MCCB 4Pole 250 Amps, 415 Volts , Adjustable type breaking capacity 35KA including nut bolts lugs & cable of suitable size complete all as directed. Make-legrand or equivalent grading marked.
M&L for taking out unserviceable DBs of any type / capacity incl MCBs for fixing of new or old all as directed
Supply and fixing in repair stepped type electronic fan regulator of AC 120/280 volt complete all as specified and as directed. Make anchor or equivalent
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip.and all as per directed.
Supply & fixing in repair for Test point box of suitable size including terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and connected with earthing strip including taking out old unsv and make good the disturbed surface complete all as per directed.
Supply & fixing in repair bldg security lighting of LED 30 watts 100 lumen /watt output high efficennt lighting solution anodised with heat resistance with accessories provided including necessary electric connection with all accessories required for fixing/mounting with nut bolt washer & clamp support on GI pipe1.5 meters of suitable diameter complete all as specified and as directed. BAJAJ Cat No:BRLEP30WLED WH or equivalent in other Make.
Supply & fixing in repair bldg security lighting of LED 90 watts 100 lumen /watt output high efficennt lighting solution anodised with heat resistance with accessories provided including necessary electric connection with all accessories required for fixing/mounting with nut bolt washer & clamp support on GI pipe1.5 meters of suitable diameter complete all as specified and as directed. BAJAJ Cat No:BRTFG90WLEDCR or equivalent in other Make.
Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity. Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Supply only heating elements of 2 KW 230 V inbuilt with thermostat, indicator lamp ,apparatus plate other accessories suitable for existing water heater of any type including connection with suitable cable all as directed
Supply only electronic digital type tempreture indicator as suitable for existing water heaterall as specified and directed by engr-in- charge
Supply only PVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser.
Supply only 450mm long brass CP connection with 2 nuts without nipple suitable for geysers.
Material and labour preparation to old painted surface of storage water heater and painting of geyser 25 ltr capacity with two coats of synthetic enamel paint (white) by using spray gun all as directed.
Supply and fix as in repair for Split cover made out of 22 guage sheet duly painted with synthetic enamel paint suitable for water heater of 25 ltr capacity.
Supply and fixing as in replacement patented nano polymer coated steel inner tank of 25Ltr capacity geyser suitable for model of make: Cromption/Usha/Bajaj complete all testing and make good in disturbed surface at existing location and all as specified and as directed.
Supply and fix as in repair for non return valve, 15mm bore, screwed down high pressure, cast copper alloy, chromium plated.
Supply and fix as in repair for pressure release valve 15mm bore 'T' type at inlet/ outlet or dead weight type heavy duty.
Supply and fix as in repair for fusible plug , calibrated 95 deg to 100 deg C suitable for water heater.
Supply and fix as in repair for glass wool , between the inner and outer vessel of water heater any type and capacity.
Supply and fix as in repair for PVC insulated flexible copper conductor cable (FRLS) 2.5 Sqmm 3 core , 1100 Volts grade conforming to IS 694.
Supply and fix in repair 15 Amp plug top Make Anchor or equivalent
Supply and fix in repair rubber gasket as in repair for appratus plate any type/capacity all as specified and directed.
Supply and fix in repairs Bib taps, cast iron alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of size 20 mm dia complete all as specified and as directed
M & L in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amp all as directed by Engr-in- Charge
Taking down ceiling fan of any type, any make and any sweep for repairing,opening the body and blade, checking for repalcement of unserviceable spares,cleaning, overhauling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and hanging up the same as directed Note : Supply & fixing new spare parts required for replacement shall be measured and paid seperately
Rewinding of ceiling fan, 1200mm sweep with synthetic enamel copper wire including insulation of starter with polyster paper/manllex paper with cotton binding, heat varnished and including flexbile cable for electric connection all as directed.
Supply only ball bearing of size 6201/6202/6203
Supply only metal bush bearing suitble for ceiling fan 1200/1400 mm sweep of any type and size complete all as specefied and directed.
Supply and fixing in repair of ceiling fan shaft suitable for 1200/1400 mm sweep of any type and size complete all as specified and directed
Supply only capacitor oil filled type for ceiling fan 2.25 MFD complete all as specified and directed.
Supply only fan blade (3 Nos blade is one set) 1200 mm sweep suitable for USHA/Havells/Bajaj or equivelent make fan and all as specified and directed.
Supply and fix as in repair of MS clamps made out of 50 x 6mm flat iron suitable for hanging of ceiling fan on pipe including necessary cutting, threading, drilling, fixing arrangement split pin, nuts, bolts washer etc as directed.
M&L in replacement of GI tubing 15 mm 'light grade',galvanised, with all fitting; suitable for hanging of ceiling fan as required all as per directed.
Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling avities with filler, one coat after cleaning all dust etc.all as directed by Engr-in-Charge
Taking down exhaust fan/wall mounted of any type, any make, by opening of body carefully checking for repalcement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling greasing, testing and fixed in original position Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Rewinding of exhaust fan, 300mm sweep with super enamelled copper wire and insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished and all as directed.
All as per item No 74 here-in-before but for exhaust fan 200mm sweep complete all as specified and directed by the Engr-in-Charge.
All as per item No 74 here-in-before but for wall mounting fan 400mm sweep complete all as specified and directed by the Engr-in-Charge.
Supply only Exhaust fan blade of capacity 200mm suitable for Model no: USHA/Havels or equivelent make complete all as specified and directed.
Supply only Exhaust fan blade of capacity 300mm suitable for Model no: USHA/Havels or equivelent make complete all as specified and directed.
M&L for Painting of Exhaust fans complete, in situ with synthetic enamel paint by spraying including filling avities with filler, two coat after cleaning all dust etc.all as directed by Engr-in-Charge
Supply and fixing in repair AC single phase electronic KWh meter of rating 5-30A class 1.0,240 V,50Hz,counter type display with Transperant hinge type box all as specified and directed by Engr-in- charge. Make HPL/landis/L&T or equivalent of other make
supply and fixing in repair AC Three phaseElectronic KWh Energy mater of rating 10-60A Class1.0,3x240v,50Hz Counter type displaywith Transparent Hinge type box Make HPL/landis/L&T or equivalent of other make
supply and fixing in repair of GI pipe medium grade 32 mm dia for fixing of celling fan and necessary hook clamp Nut bolt etc all as specified and directed by Engr-in- Charge
RADHA ENTERPRISE
ARATI TRADING CO
dutta and dutta
KWALITY CONSTRUCTION
S.M.CONSTRUCTIONS
MS AP CONSTRUTION AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .