| 1 | L1₹10.3 LAccepted-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹10.3 L Quoted ₹11.3 L | L1 | Accepted-AOC LOWEST TENDERER. |
| 2 | L2₹11.7 L+₹45,195 (4.00%)Rejected-AOC NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | ₹11.7 L+₹45,195 (4.00%) | L2 | Rejected-AOC NOT LOWEST TENDERER. |
| Sl No | Description | Qty | Unit | M/S JAINENDRA KUMAR JAIN L2 | Shri Sai Enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down ceiling fan/exhaust fan /air circulating fan/wall fan of any size or of any make from any locations (OTM/Md Accn) under GE (AF) Nagpur by disconnection eletric connection, cleaning the fan box area, bringing to AGE E/M Yard and refixing at the desired location after reassembling and removing of burnt out windings (copper/aluminium), servicing/ overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/ grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material/items,making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using minor sparte/parts such as screws, insulation tape, nuts, bolts, washers, split pins etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed.
Note:- (i) PVC copper flexible wire 1.50 Sqmm three core, nut bolts, washers, screws, capacitor clamp, warnishing included in the quoted rate.
(ii) Other connected items required like re-winding, painting, capacitors, Bearings, Bush, Canopy,down rods etc will be measured and paid sperately under respective items.
(iii) Total service time from taking down to rehanging must not exceed 03 Days .
(iv) Cost of T&P & transportation including taking down and re-fixing are included in the quoted rate | 1,250 | EACH JOB | 50 ₹62,500 Lowest | 60 ₹75,000 |
| 2.00 | Material and labour for re-winding of ceiling fan 1200mm/1400mm sweep which of copper winding with proper grade/guage super enamelled copper winding wire so as to achieve original specifications i.e current rating and RPM (RPM test of ceiling fan with suitable tachometer will be done by contractor and shown to deptt , tachometer will be provided by contractor at their own expense) and all insulating materials (spares will be used and measure in respective items) and reasembling etc complete all as specified and directed. | 500 | EACH JOB | 500 ₹2,50,000 | 425 ₹2,12,500 Lowest |
| 2.10Notes for Sr Noitem No 1 & 2 :- (i) The fans should be re-winded as per existing guage copper winding . Schedule of credit shall be deducted as per the burnt out winding. (ii) Winding wire shall be cut in front of Engr-in-Charge before winding of fans. (iii) In case winding or any accessory i.e capacitor, regulator becomes non functional during defect liability period, it will be repaired without any extra payment within 05 days of complaints received. | |||||
| 3.00 | All as per item No 2 above but for exhaust fans any type of size 150 mm sweep to 380 mm sweep. | 130 | EACH | 430 ₹55,900 | 375 ₹48,750 Lowest |
| 4.00 | All as per item No 2 above but for exhaust fan any type of size 450 mm sweep | 25 | EACH | 520 ₹13,000 | 375 ₹9,375 Lowest |
| 5.00 | All as per item No 2 above but for wall fan of any size | 80 | EACH | 400 ₹32,000 | 375 ₹30,000 Lowest |
| 6.00 | Material and labour for replacement of defective ball bearing for ceiling fans/exhaust fans/Air-circulators/Wall fan of any size and of any make complete all as directed.
Make: NBC/TATA/SKF | 620 | EACH | 70 ₹43,400 Lowest | 140 ₹86,800 |
| 7.00 | Material and labour for replacement of defective Shaft for ceiling fans/exhaust fans/Air-circulators/wall fan of any size and of any make complete all as directed. | 250 | EACH | 70 ₹17,500 Lowest | 100 ₹25,000 |
| 8.00 | Material and labour for replacement of defective gear box for wall fan of any size and of any make complete all as directed. | 50 | EACH | 100 ₹5,000 Lowest | 150 ₹7,500 |
| 9.00 | Material and labour for replacement of defective swing motor for wall fan of any size and of any make complete all as directed. | 60 | EACH | 150 ₹9,000 Lowest | 150 ₹9,000 Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
3 Feb 2026, 6:00 pmClosed
LT COL RAVI KUMAR PATIYAL, GE
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINTENANCE OF CEILING FAN, EXHAUST FANS AND GEYSERS AT VAYUSENA NAGAR NAGPUR
2026_MES_748377_1
8794/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF NAGPUR
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹30,000
21 Mar 2026
13 Jan 2026
5 Feb 2026
13 Jan 2026
3 Feb 2026
27 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down ceiling fan/exhaust fan /air circulating fan/wall fan of any size or of any make from any locations (OTM/Md Accn) under GE (AF) Nagpur by disconnection eletric connection, cleaning the fan box area, bringing to AGE E/M Yard and refixing at the desired location after reassembling and removing of burnt out windings (copper/aluminium), servicing/ overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/ grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material/items,making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using minor sparte/parts such as screws, insulation tape, nuts, bolts, washers, split pins etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed.
Note:- (i) PVC copper flexible wire 1.50 Sqmm three core, nut bolts, washers, screws, capacitor clamp, warnishing included in the quoted rate.
(ii) Other connected items required like re-winding, painting, capacitors, Bearings, Bush, Canopy,down rods etc will be measured and paid sperately under respective items.
(iii) Total service time from taking down to rehanging must not exceed 03 Days .
(iv) Cost of T&P & transportation including taking down and re-fixing are included in the quoted rate | 1,250 | EACH JOB | - | - |
| 2 | Material and labour for re-winding of ceiling fan 1200mm/1400mm sweep which of copper winding with proper grade/guage super enamelled copper winding wire so as to achieve original specifications i.e current rating and RPM (RPM test of ceiling fan with suitable tachometer will be done by contractor and shown to deptt , tachometer will be provided by contractor at their own expense) and all insulating materials (spares will be used and measure in respective items) and reasembling etc complete all as specified and directed. | 500 | EACH JOB | - | - |
| 3 | All as per item No 2 above but for exhaust fans any type of size 150 mm sweep to 380 mm sweep. | 130 | EACH | - | - |
| 4 | All as per item No 2 above but for exhaust fan any type of size 450 mm sweep | 25 | EACH | - | - |
| 5 | All as per item No 2 above but for wall fan of any size | 80 | EACH | - | - |
| 6 | Material and labour for replacement of defective ball bearing for ceiling fans/exhaust fans/Air-circulators/Wall fan of any size and of any make complete all as directed.
Make: NBC/TATA/SKF | 620 | EACH | - | - |
| 7 | Material and labour for replacement of defective Shaft for ceiling fans/exhaust fans/Air-circulators/wall fan of any size and of any make complete all as directed. | 250 | EACH | - | - |
| 8 | Material and labour for replacement of defective gear box for wall fan of any size and of any make complete all as directed. | 50 | EACH | - | - |
| 9 | Material and labour for replacement of defective swing motor for wall fan of any size and of any make complete all as directed. | 60 | EACH | - | - |
| 10 | Material and labour for replacement of defective capacitor of size 2.5 mfd ISI marked for any type of fans suitable for 250V/230V including making connection complete all as specified and directed.
Make : Havells/Legrand/Epcos/ Siemens | 300 | EACH | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.16 MB
BOQ_838082.xls
BOQ • 0.45 MB
TENDERDOCS8794.pdf
Tender Documents • 0.34 MB
SOC8794.pdf
Tender Documents • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .