Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC A 102 GOLDEN SAND APARTMENTS GAZIPUR DHAKOLI ZIRAKPUR PB 160104 | ZIRAKPUR | S A S NAGAR | PUNJAB | 160104 | ₹3.6 Cr | L1 | Accepted-AOC Reasonable rate. Tender Accepted |
| 2 | L2₹3.7 Cr+₹12.9 L (3.60%)Rejected-Finance HOUSE NO 89 BEHIND DD LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | ₹3.7 Cr+₹12.9 L (3.60%) | L2 | Rejected-Finance Bid on higher side |
| 3 | L3₹4.0 Cr+₹38.1 L (10.7%)Rejected-Finance | ₹4.0 Cr+₹38.1 L (10.7%) | L3 | Rejected-Finance Bid on higher side |
| 4 | L4₹4.1 Cr+₹52.5 L (14.7%)Rejected-Finance | ₹4.1 Cr+₹52.5 L (14.7%) | L4 | Rejected-Finance Bid on higher side |
| 5 | Rejected-Technical VILLAGE BATWAL SUB TEHSIL BARWALA NEAR RAIPUR RANI DISTT PANCHKULA 134204 | YAMUNANAGAR | HARYANA | 134204 | - | - | Rejected-Technical Not having required eligible Category a(i) (Building work) as per NIT |
Tender Value
₹4 Cr
EMD Value
₹4.8 L
Closing Date
24 Aug 2021, 6:00 pmClosed
CHIEF ENGINEER LEH ZONE
HQ CHIEF ENGINEER LEH ZONE C/O 56 APO
AUGMENTATION OF SOLAR POWER PLANT BY PROVN OF TRANSMISSION NETWORK AND DG SET AT PARTPAUR AND BASE CAMP
2021_MES_458606_1
180074/E8
Open Tender
Civil Works
Lump-sum
700 days
PARTAPUR
As per NIT
8 documents required · 8 mandatory
₹2,000
GE Partapur
₹4.8 L
Yes
18 Sept 2021
9 Jul 2021
31 Aug 2021
9 Jul 2021
24 Aug 2021
10 Aug 2021
10 Jul 2021 - 24 Jul 2021
Amount
BUILDING WORK (SCHEDULE 'A' PART-I) Lump sum price worked out by the Contractor for “Building Work ”as listed in Schedule ‘A’ Part- I.
INSULATION OF BUILDING (SCHEDULE 'A' PART-II) Lump sum price worked out by the Contractor for “Insulation of Building ”as listed in Schedule ‘A’ Part- II.
INTERNAL WATER SUPPLY (SCHEDULE 'A' PART-III) Lump sum price worked out by the Contractor for “Internal water supply ”as listed in Schedule ‘A’ Part- III.
INTERNAL ELECTRIC SUPPLY (SCHEDULE 'A' PART-IV (SECTION-I) Lump sum price worked out by the Contractor for “Internal Electric Supply ”as listed in Schedule ‘A’ Part- IV (Section-I)
INTERNAL ELECTRIC SUPPLY (SCHEDULE 'A' PART-IV (SECTION-II) is not prepriced by MES and prepriced rates indicates 5.01 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col -6. __________________________________________
S & F LED 9 W ball lamp all as specified and as directed.
Sub Total
PUFF WATER TANK (SCHEDULE 'A' PART-V) is not prepriced by MES and prepriced rates indicates 6.01 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col -6.
Supply and Installation of puff water tank 500 Ltr insulated cylinderical vertical type double layer duly field with glass wool with closed top hoisted and to resist in tempature (-) 30 degree Celisius to +35 degree Celisius fixed in position with all fittings over PCC platform complete all as specified and as directed.
Sub Total
SITE CLEARANCE AND DEVELOPMENT (SCHEDULE 'A' PART-VI) Lump sum price worked out by the Contractor for “Site clearance” as listed in Schedule ‘A’ Part- VI
HARDSTANDING (SCHEDULE 'A' PART-VII) Lump sum price worked out by the Contractor for “Hardstanding” as listed in Schedule ‘A’ Part- VII
SEWAGE DISPOSAL (SCHEDULE 'A' PART-VIII) Lump sum price worked out by the Contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part- VIII
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-IX) (SEC-I) Lump sum price worked out by the Contractor for “External Electrification” as listed in Schedule ‘A’ Part- IX (Sec-I)
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-IX) (SEC-II) is not pre-priced by MES and pre-priced rates indicates 12.00 to 22.00 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply, Installation, testing etc and commissioning of Diesel Engine driven generating set of capacity 600 KVA, 415 Volt, 0.80 PF at NTP, mounted on comman base frame alongwith sound proof enclosure (Acoustic enclosure) designed for reducing the sound level to 75 DBA at 01 mtr (average) IS 8528 Para -10 as per approved CPCB norms and as per GSR 371 (E) and 17.05.2020 and its amendments under environment (protection) act 1996, 1500 RPM alongwith AMF Panel with following:-
(i) Silencer pipe independently shorted from Engine to Outside up to 01 Mtr.
(ii) AVM padded foundation as per manufacturer design (iii) Cold starting kit. (iv) Battery, start with suitable size cable for connector from DG set to LT panel board (v) DG set shall be capable of operating in temp range of (-40 degree centrigade to + 35 degree centegrade) (vi) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test (vii) The quoted rate shall be catered to be inclusive of 12 hrs test run at site including of 1 hr on 10% overhead in presence of representative / IEM detailed by accepcting officer, all arrangement made by the contractor for test.
(A) Alternator: Std design alternator rated at 600 KVA, 3 phase, 4 wire and 415 Volts at NTP 0.8 PF, 50 Hz, 1500 RPM, self excited, self regulated, screen protected and drip proof of IP 23 enclosure brush less design with winding in pole faces, insulation class "H" and voltage regulation of +1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be in position to generate supply with frequency regulation with in +1% tolerance. Make- Jyoti/Gec/Stamford/Kirloskar/CG (i) Insulation class 'H' (ii) Temp rise class 'H' (iii) Excitation - Self excited (iv) Regulation performance- The voltage kept constant with +1% mannual voltage adjustment within +5% (v) Frq regulation +1%
(B) Prime Mover Vertical Diesel of suitable capacity water cooled (Radiator mounted) enclosed circuit as per BS 649 or IS 10002 direct injuction type turbo charge electric starting system having rated speed 1500 RPM. The DG set shall be capable of running 24 hrs continuously with 10% overloading for 1 hr in every 12 hrs as per BS 5514/BS648. Engine shall be equipped with all standard fittings as per manufacturers recommendations and mounted on comman base frame with following accessories as per manufacturers design. Make Kirloskar / Cummins / Greaves Cotton :- (i) Fly wheel with housing (ii) Cooling System- Mounted radiator with fan and belts (iii) Cooling water pump - Centrifugal type belt driven (iv) Exhaust System- Complete with exhaust piping of 200 mm dia with MS Pipe light grade up to and away from the enclosure to be arected coverd with asbstos rope and aluminium foil of 28SWG complete with in the enclosure for safe exhaust without transforming vibaration to the wall of the enclosure. Exhaust gases turbo charger type exhaust manifold silencer residential type.
(C) Fuel System Fuel injuction system with fuel injector, fuel injector solenoid switch / nozzles /governer mechanical type capable for 1% speed / frequency regulation. Fuel filter and fuel hosses
(i) Lubrication Oil System - Lubrication oil filter, lubricating oil pump
(ii) Air Intake System - Air intake manifold air cleaner dry type
(iii) Governer - Electrionic governor class A1 (governing)
(iv) Starting System - Electric self starter with maintenance free battery incl battery charging alternator
(v) Batteries : 2 Nos, maint free batteries of 12 V, 180 AH Capacity complete with copper conductor multistandred leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all make of battery exide start and stop push button iginition key/switch. Handling and operation salient features of acessories shall be as under :- Radiator with blower fan crossion in hibitor coolent paper element filter for fuel, lubricant oil and by pass.
(vi) Gen Monetering Panel - Comprising of following (a) Microprocessor based gen set controller for metering, monitering, governing and protection (b) Engine protection for low lub oil pressure high coolent temp (alarm and shut down) (c ) Alternation protection perameter over/under voltage over current under freq, over freq (Alarm and shut dowm) (d) Relay drivers for remote control applications (e) Cyclic crancking (f) Auto/manual Start/Stop (g) Alternator trim adjustment from the front key pad (h) Gen set metering parameter like-lubrication oil pressure, coolent temp, engine speed, hours run, DC voltage manifold temp, three phase voltage, Amp freq KW , KVA, PF and KWH.
(vii) Safety Controls :- Engine low high pressure high water temp and over speed engine
(viii) Coupling arrangement - Flexible coupling fly wheel
(ix) Accessories - AVM Pads builts or sperately mounted manufacturer base frame.
(x) Fuel Tank - Suitable capacity as per manufacturer instruction as per capable to store 12 hrs running of DG Set
(d) AMF Panel
Supply installation, testing and commissioning of AMF Panel with following description : FP Electrically operated drawout type air circuit breaker with thermal magnetic based release for o/c s/c release and other std accessories
(i) Miniature circuit Breaker, 10 KA rating DP,6-32A
(ii) MCB SP 6-25 Amp, 10 KA
(ii) MCB SP 4 Amp, 10 KA
(iv) KWH Mtr digital 415 V AC (v) KW/PF Mtr 3 Phase 4 Wire 96x96 Sqmm digitial 415 V AC
(vii) DC Amp / voltmeter 96 x96 sqmm
(viii) Soild state single element earth fault relay with 2 C/O contact (CTR 1000/5 aux 230 V AC)
(viii) Engine cranking relay for C/o 24 V DC
(ix) Mains voltage monitor relay, 2 c/o 415 V AC
(x) Aux realy 24 V DC for c/o 14 pin 240 V AC
(xi) Aux relay 240 V AC for c/o 14 Pin 240 V
(xii) Aux contactor with 2 NO + 2NC Aux contact
(xiii) CT-1000/5 AMP class 0.5 15 VA (xiv) CT-1000/5Amp Cl-1 15 VA (xv) CT-500/5Amp Cl-5P10 15 VA
(xviii) Indication Lamp- RYB (xix) Push button , Masroom head emergency push button press to lock turn to release-Red
(xx) 24 V DC automatic tricky /boost bty charger with constant voltage outpur 24 V/25 Amp
(xxi) Four point alarm annoucator with inbuilt hooter 24 V DC with reset push button
(xxii) On delay timer 240 V AC 0.6 to 60 Sec and on delay timer 240 volt AC 18-180 Sec
(xxiii) Civil Works All civil works including PCC plate form as per manufacture design and related to foundation including of panel and equipment’s including marking good of existing disturbed surface during installation and commission of generator set.
Supply and installation erection commissioning and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated CPRI approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 400 Amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:-
MS Sheet body of LT Panel With double door angle iron frame
Incomming
(a) MCCB, 200Amps, 36 KA Optium 1.0 (Fixed TM range) 4 pole -01 Nos
Outgoing
(b) MCCB, 63 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(c) MCCB, 40 Amps, 16 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(d) MCCB, 25 Amps, 16 KA, Optium 1.0 (Fixed TM range) 4 pole-01 Nos
(e) MCCB, 16 Amps, 10 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(f) LED type phase indicattor lamp (R Y B) - 01 Set
(j) Change over 200 Amps -01 Nos
Supply and installation erection commissioning and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated CPRI approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 600 Amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:-
MS Sheet body of LT Panel With double door angle iron frame
Incomming
(a) MCCB, 400Amps, 36 KA Optium 1.0 (Fixed TM range) 4 pole -01 Nos
Outgoing
(b) MCCB, 63 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(c) MCCB, 25 Amps, 16 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(d) MCCB, 50 Amps, 16 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(e) MCCB, 80 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(f) LED type phase indicattor lamp (R Y B) - 01 Set
(j) Change over 400 Amps-01 Nos
Supply and installation erection commissioning and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated CPRI approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 600 Amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:-
MS Sheet body of LT Panel With double door angle iron frame
Incomming
(a) MCCB, 315Amps, 36 KA Optium 1.0 (Fixed TM range) 4 pole -01 Nos
Outgoing
(b) MCCB, 80 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(c) MCCB, 100 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(d) MCCB, 16 Amps, 10 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(e) LED type phase indicattor lamp (R Y B) - 01 Set
(h) Change over 315 Amps -01 Nos
Supply and installation erection commissioning and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated CPRI approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 400 Amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:-
MS Sheet body of LT Panel With double door angle iron frame
Incomming
(a) MCCB, 100Amps, 36 KA Optium 1.0 (Fixed TM range) 4 pole -01 Nos
Outgoing
(b) MCCB, 25 Amps, 16 KA, Optium 1.0 (Fixed TM range) 4 pole -02 Nos
(c) MCCB, 16 Amps, 10 KA, Optium 1.0 (Fixed TM range) 4 pole -02 Nos
(d) LED type phase indicattor lamp (R Y B) - 01 Set
(g) Change over 100 Amps -01 Nos
Supply and installation erection commissioning and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated CPRI approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 600 Amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:-
MS Sheet body of LT Panel With double door angle iron frame
Incomming
(a) MCCB, 400Amps, 50 KA Optium 1.0 (Fixed TM range) 4 pole - 01 Nos
Outgoing
(b) MCCB, 16 Amps, 10 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(c) MCCB, 100 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(d) MCCB, 32 Amps, 16 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(e) MCCB, 63 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(f) LED type phase indicattor lamp (R Y B) - 01 Set
(i) Change over 400 Amps -01 Nos
Supply and installation erection commissioning and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated CPRI approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 400 Amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:-
MS Sheet body of LT Panel With double door angle iron frame
Incomming
(a) MCCB, 160Amps, 36 KA Optium 1.0 (Fixed TM range) 4 pole -01 Nos
Outgoing
(b) MCCB, 50 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(c) MCCB, 63 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole -01 Nos
(d) MCCB, 16 Amps, 10 KA, Optium 1.0 (Fixed TM range) 4 pole - 01 Nos
(e) LED type phase indicattor lamp (R Y B) - 01 Set
(h) Change over 160 Amps-01 Nos
Supply installation, testing and commissioning of Synchronization Panel to synchronize parallel operation of two numbers 834 Amp, 480 KW, 600 KVA Diesel Engine Generator 415 Volts, 50 Hz including following:-
(i) Bus bar aluminium 1600 Amp duly epoxy painted and coated with fire retardant tap in a panel of MS 3.15 mm thickness cubicle duly supported to be installed on PCC pedestal on indoor substation to accommodate two numbers Air Circuit Breakers, with IP 55 Protection and host of relays indicating and controlling equipment duly wired with color coded copper wiress.
(ii) Two numbers ACB 1000 A, 4P, 50 Kilo Amp, Microprocessor based front operated draw out type with overload / short circuit protection including digital ammeter (0-1000A) voltmeter (0-500 V) along with CTs/PTs on both the ACBs
(iii) Synchroscope with LED display lamps with relays and contactors to accommodate power from both side, frequency meter (0-50Hz) ammeter (0-1200 A) volt meter (0-500 V) alongwith CTs/PTs
(iv) Earthing test points on two sides
(v) Suitable sized openings including GM cable glands for fixing armoring should be provided
(vi) Space should be kept for any bus trunking arrangements so that power could also be supplied using bus trunking instead of cables.
Make:- Kirloskar, Crompton Greaves, Mahindra (The Synchronizing panel has to be manufactured by the principles and locally fabricated and separately supplied panels shall not be accepted.)
Supply installation, testing and commissioning of AMF Panel with following description : FP Electrically operated drawout type air circuit breaker with thermal magnetic based release for o/c s/c release and other std accessories and competiable for existing 600 KVA DG Set.
(i) Miniature Ckt Breaker, 10 KA rating DP,6-32A
(ii) MCB SP 6-25 Amp, 10 KA
(ii) MCB SP 4 Amp, 10 KA
(iv) KWH Mtr digital 415 V AC (v) KW/PF Mtr 3 Phase 4 Wire 96x96 Sqmm digitial 415 V AC
(vii) DC Amp / voltmeter 96 x96 sqmm
(viii) Soild state single element earth fault relay with 2 C/O contact (CTR 1000/5 aux 230 V AC)
(viii) Engine cranking relay for C/o 24 V DC
(ix) Mains voltage monitor relay, 2 c/o 415 V AC
(x) Aux realy 24 V DC for c/o 14 pin 240 V AC
(xi) Aux relay 240 V AC for c/o 14 Pin 240 V
(xii) Aux contactor with 2 NO + 2NC Aux contact
(xiii) CT-1000/5 AMP class 0.5 15 VA (xiv) CT-1000/5Amp Cl-1 15 VA (xv) CT-500/5Amp Cl-5P10 15 VA
(xviii) Indication Lamp- RYB (xix) Push button , Masroom head emergency push button press to lock turn to release-Red
(xx) 24 V DC automatic tricky /boost bty charger with constant voltage outpur 24 V/25 Amp
(xxi) Four point alarm annoucator with inbuilt hooter 24 V DC with reset push button
(xxii) On delay timer 240 V AC 0.6 to 60 Sec and on delay timer 240 volt AC 18-180 Sec
Labour of dismantling connnections, Shifting of DG existing DG set of 600 KVA from Old plant Room Base Camp-II to New Plant Room near by proposed Solar Plant.
Sub Total
M/S HIGHLAND ENGINEERING
Vinayaka Enterprises
Intrernational Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .