Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
5 Apr 2021, 6:00 pmClosed
GE (AF) Nal, Bikaner
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2021_MES_426289_1
GE (AF) NAL/T-50/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) Nal
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Nal
₹50,000
Yes
GE (AF) NAL
15 Apr 2021
27 Feb 2021
7 Apr 2021
27 Feb 2021
5 Apr 2021
12 Mar 2021
1 Mar 2021 - 6 Mar 2021
9 Mar 2021
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour sand cushioning (Tibba Sand) for protection of underground cable, consolidated and compacted with clean dry sand complete all as specified and as directed.
Supply and laying Precast unreinforced Concrete cable covers Class HV, type 1 flat of size 300mm x 180mm x 40 mm for HT cable all as specefied
Taking out HT un-serviceable / faulty cable of Cross sectional area 70 sq mm, 3 core from trench / pole / cable duct carefully incl bricks protection, pipe and stacking properly for disposing off from site or for relaying in same place complete all as directed Note : (i) Excavation and earth work shall be measured and paid separately. (ii) Unit rate of this item include the cost of taking out brick protection/ tiles and GI Pipe etc as applicable. (iii) Old serviceable cable shall be stored properly for relaying / handing over to contractor for disposal off from site.
All as per description of serial item No. 6.00 here in before but cable of cross sectional area 95 sqmm, 3 core
All as per description of serial item No. 6.00 here in before but cable of cross sectional area 120 sqmm, 3 core
Laying only including testing of HT serviceable PVC / XLPE insulated 11000 Volts grade aluminium conductor cable Cross sectional area 70 sq mm, 3 core in trench or fixed to wall /passing through pipe / pole complete all as specified and directed. Note : (i) Old serviceable cable retrived under Item No. 6.00 here-in-before shall be used in the work. (ii) Brick protection, concrete cable cover, sand cushioning shall be measured and paid for separately.
All as per description of serial item No. 9.00 here in before but cable of cross sectional area 95 sqmm, 3 core. Note : (i) Old serviceable cable retrived under Item No. 7.00 here-in-before shall be used in the work. (ii) Brick protection, concrete cable cover, sand cushioning shall be measured and paid for separately.
All as per description of serial item No. 9.00 here in before but cable of cross sectional area 120 sqmm, 3 core. Note : (i) Old serviceable cable retrived under Item No. 8.00 here-in-before shall be used in the work. (ii) Brick protection, concrete cable cover, sand cushioning shall be measured and paid for separately.
Supply, laying and testing XLPE insulated, armoured 11000 Volts grade aluminium conductor cable, Cross sectional area 70 sq mm, 3 core, as per IS-7098 (Part-II), in trenches or fixed to wall /passing through pipe / pole, as directed for the following cross sections. Note : (i) Excavation and earth work shall be measured and paid for separately. (ii) Concrete cover protectioin and sand cushining shall be measured and paid for separately. (iii) Pipe including clamps shall also be measured and paid for separately.
All as per description of serial item No. 12.00 here in before but cable of cross sectional area 95 sqmm, 3 core
All as per description of serial item No. 12.00 here in before but cable of cross sectional area 120 sqmm, 3 core
M&L as in repairs straight through joint HT 11000 volts grade heat shrinkable of cable Cross sectional area 50 Sqmm, 3 core complete all as specified and directed. Note : 1. Excavation & earthwork shall be measured and paid for separately
All as per description of serial item No. 15.00 here in before but for cable of cross sectional area 70 sqmm, 3 core
All as per description of serial item No. 15.00 here in before but for cable of cross sectional area 95 sqmm, 3 core
All as per description of serial item No. 15.00 here in before but for cable of cross sectional area 120 sqmm, 3 core
S&F as in repairs End termination joint (Out door type) heat shrinkable HT 11000 volts grade of cable Cross sectional area 70 Sqmm, 3 core complete all as specified and directed.
All as per description of serial item No. 19.00 here in before but for cable of cross sectional area 95 sqmm, 3 core
All as per description of serial item No. 19.00 here in before but for cable of cross sectional area 120 sqmm, 3 core
M&L as in repairs End termination joint (Indoor type) heat shrinkable HT 11000 volts grade of cable Cross sectional area 70 Sqmm, 3 core complete all as specified and directed.
All as per description of serial item No. 22.00 here in before but for cable of cross sectional area 95 sqmm, 3 core
All as per description of serial item No. 22.00 here in before but for cable of cross sectional area 120 sqmm, 3 core
Supply and fixing GI tubing light grade 80 mm bore for cable protection complete all as specified and directed. Note:- Cost of taking out of pipe included in unit rate for taking out cable here-in-before.
All as per description of serial item No. 25.00 here in before but 100mm bore pipe
Tracing out fault in 11KV underground cable any size with the help of fault tracing machine and rectifying the same with joints as specified and directed to restore the supply complete all as specified. Note: (i). Joint kit shall be measured and paid separately. (ii) Earth work shall be measured and paid separately. However, width of trenches shall be allowed for payment as per authorized width given in SSR for each size of cable. (iii) All other necessary arrangements suitable for locating the faults deemed to be included in the unit rate quoted. (iv) T&P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account. (v) Cable required, if any shall be measured and paid for separately. (vi) Fault & location thereof shall be traced within 12 hours of intimation by the Engineer-in-Charge and shall be rectified within given time frame
M&L Disconnecting, opening of 33KV, 3 Pole, 200/ 400 Amps, outdoor type Porcelain Clad Vaccum Circuit Breaker of Make: Crompton Greaves / GEC, type : 36PV25A (used for protection of 33/11 KV ,3.15 MVA transformer) for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing and caliberation, greasing, oiling of parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing and commisioning complete all as specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid for separately under relevent item of sch 'A' as supply only but cost of fixing of the parts replaced/repaired shall be deemed to be included in this item. (ii) Servicing shall be got carried out by the authorised rep of VCB manufacturer. The service engineer will submit a service report including calibration for each VCB and unit rate of this item includes this element. (iii) Any item not mentioned in the description of item above but required for successful operation of the panel shall be provided by the contractor and the cost there of shall be deemed to be included unit rate quoted. (iv) Complete repair/ services as applicable shall be carried out at work site only. (v) Complete job shall be completed within reasonable time as allowed by the GE/Engineer-in-Charge, accordingly contractor shall provide all arrangements including T&P and equipments/ parts well in time for timely completion of work. Tenderer are hereby advised to keep this factor while quoting their rates.
Supply only following parts suitable for 33KV VCB of Make : Crompton / GEC dismantled / fixed under Sch 'A' item No: 28.00 here-in-before complete all as specified and directed:-
Tripping Coil assembly 24 Volts DC suitable for 33 KV VCB Panel
Close Coil assembly 24 Volts DC suitable for 33 KV VCB Panel
TNC switch for 33 KV VCB Panel
Indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC supply.
HRC fuse blade type 2 Amps, 24 Volt,
M&L Servicing of 33 KV Potential Transformer, cleaning of core, checking of all connections replacement of oil and testing of all connections complete all as specified and directed. Note:- Oil shall be measured and paid for separately under respective item of this Schedule.
M&L Servicing of 33 KV Current Transformer, cleaning of core, replacement of oil (40 Ltr), testing of all connection complete all as specified and directed. Note:- Oil shall be measured and paid seperatly under respective item as 'Supply only'.
Supply and filling transformer power oil meeting IEC 60296-2003-11, 3rd edition standard specification and ASTMD 1275B test requirements for corrosive sulpher of BDV not less than 65 KV for topping up the Power/distribution transformer HT 33 KV / 11 KV. NOTE:- Transformer oil shall be brought by the contractor in sealed standard packing in barrell of 210 ltrs capacity. Contractor shall produce the original purchase vouchers and test certificate from the manufacturer.
M&L filteration and dehydration of transformer oil by dehydration machine to achieve the die-electric strength / insulation value upto 65 KV/40KV (RMS) at standard gap of electrodes 2.5 mm for one minute in various capacity of transformers 33/11KV and 11/0.433KV including insulation testing of oil with help of suitable equipments before and after dehydration including BDV Test complete all as specified and directed.
Supply and fixing as in repairs PG clamp die cast aluminium of suitable size and for fixing clampling ACSR conductor connections for PT's CTs isolators all as specified
Disconnecting, opening of indoor type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom) of any description and any make of rating 11 KV 400/630/800 Amps capacity for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing and its testing complete all a specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid separately under relevent item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in the item rate. (ii) Servicing shall be got carried out by the authorised rep of the VCB manufacturer and the service engineer will submit a service report and calibration certificate for each VCB. (iii) Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
Supply only following parts suitable for 11KV VCB, 400/630 Amps capacity of Make : Crompton/Megawin/Yamuna Denson/ABB Ltd, Alstom) dismantled / fixed under Sch 'A' item No: 35 here-in-before complete all as specified and directed.
Isolating contact assembly 400/630/800 Amps suitable for 11 KV/400/630/800 Amp VCB Panel
Tripping Coil assembly 24/30 Volts DC suitable for 11 KV VCB Panel
Close Coil assembly 24/30 Volts DC suitable for 11 KV VCB Panel
TNC switch for 11 KV VCB Panel
Indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC supply.
Supply only HRC fuse 11 KV grade 5 Amps.
M&L testing and calibration of 11KV VCBs (Make : Crompton / Megawin / Dension / ABB Ltd, Alstom) indoor type alongwith control panel and control wiring, protection system and relays system (relay to tripping coil auxiliary switch male and female housing cut outs etc) , checking of quality of vacuum interrupter, insulation resistances, static contact resistance, Testing (IR value, Ratio test, Polarity test) and connection verification of 11 KV Current transformer (Set of three) by PRIMARY INJECTION KIT and Testing and calibration of relay (set of two Over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. complete all as specefied and directed.
M&L for servicing testing and calibration of 11KV SF6 circuit breaker/ 01 Way 400/630 Amp (Make : CG Lucy/ Crompton/Megawin/ Dension/ABB Ltd, Alstom) indoor type alongwith control panel and control wiring, protection system and relays system (relay to tripping coil auxiliary switch male and female housing cut outs etc) , checking of quality of vacuum interrupter, insulation resistances, static contact resistance, Testing (IR value, Ratio test, Polarity test) and connection verification of 11 KV Current transformer( Set of three) by PRIMARY INJECTION KIT and Testing and calibration of relay (set of two Over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. complete all as specefied and directed.
All as per description of serial item No. 38.00 here in before but 3 way RMU having 2 Nos I/C and one No out going
M&L repair to distribution transformer step down 11/0.433 KV indoor/outdoor type of capacity up to 250 KVA, by dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oil from the housing complete, taking out the core and winding by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, varnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, re-installing the core and winding inside properly, making the all connection with suitable copper lugs, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, explosion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed. Note :- (i) Winding wire for making of coils, HT/LT bushes, new transformer oil will be measured & paid for seperately (ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation.
All as per description of serial item No. 40.00 here in before but capacity of transformer 11 / 0.433 KV, above 250 KVA upto 630 KVA complete all as directed.
Supply only brass terminal rod with nuts, bolts washers & bushings suitable for HT and LT side of the transformer of any make and capacity upto 250KVA complete.
All as per description of serial item No. 42.00 here in before but capacity of transformer exceeding 250 KVA but not exceeding 400 KVA.
All as per description of serial item No. 42.00 here in before but capacity of transformer exceeding 400 KVA but not exceeding 630 KVA.
Supply only super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding of 11/0.433 KV distribution transformer complete all as directed.
Material and labour for dismantling and taking out HT RMU 11 KV SF6 /VCB panel consisting of two incomer and one out going from CCR substation carefully for reuse, after disconncting of all HT cable connection , control wiring etc and shifting the same to ATC Sub Station including necassary addition, alteration and modification of existing cable duct, connection of existing HT cable, control wiring, cable joints, earth strip etc and testing the same complete all as spcified and directed. Note : Rate is inclusive of making arrangement for shifting the panel carefully from CCR substation for reuse at Tech area, complete all specified and derected. Note :- Rate quoted shall deemed to be included for the following :- (i) Dismantling HT destribution panel carefully after removing bus bar and in set of 3 or in part as directed by Engineer in Charge. (ii) Contractor shall carried out the work simultaneously with executing Item Srl No. 47 and 48 at a time to ensure minimum disturbance.
Material and labour for shifting of HT 11 KV SF6 Ring main Unit (RMU) consisting of two incomer and two out going from MES store yard and reinstall the same carefully at CCR sub station including necassary addition, alteration and modification of existing cable duct , modification coppr busbar and connection of existing HT cable, control wiring, cable joints, earth strip etc and testing the same complete all as spcified and directed. Note :Rate quoted shall deemed to be included for the following :- (i) Making arrangement for shifting the panel carefully from MES store yard to CCR substation for reuse at Tech area, complete all specified and derected. (ii) RMU unit dismantled from MRS and laying in MES store yard shall be reused. Note:- (i) HT cable, cable end Joint and Straight through joint shall be measured and paid separatly. (ii) Earth work and Cable duct work shall be measured and paid separatly.
BLANK
All as per description of serial item No. 48.00 here in before but HT 11 KV SF6 Ring main Unit (RMU) one incomer and one out going install with existing SF6 RMU 3 way by extending existing Bus bar complete all as specified and directed.
All as per description of serial item No. 48.00 here in before but HT 11 KV SF6 Ring main Unit (RMU) two incomer and two out going with bus coupler reinstall with raplacement of existing VL switch at North Loop Sub Station all as specified and directed. Note :- Unit rate of this item included the cost of dismantling of old unserviceable VL unit and deposit the same at MES store yard.
BLANK
S&F as in repairs Junction Box (Bus bar chamber box) of size 250 mm x 200 mm x 105 mm made out plastic suitable for 415 Volt, 63 A, 4 way TPN aluminium bus bars of capacity 100 Amp with 01 No. MCB, SP, 2.5 Amp, 240 volts, 10 KA for controlling the street light complete fixing arrangement to the pole with nut, bolts and washers including providing the electrical connection for incoming / outgoing cable through proper lugs/thimbles complete all as specified and directed.
Material and labour for making cable duct in power houses located at various location of Tech Area Demestic area by cutting existing floor for size width 450 mm x depth 600 mm (internal dimension of duct) depth of duct to be reckoned from the top of PCC in foundation to top existing floor as 600 mm and including duct cover of suitable size with 3 mm thick MS chequred plate cover and frame of angl iron 40 mm x 40 mm x 6 mm with fixing arrangement and painting two coat of synthetic enamel paint over a coat of red oxide primer on MS chequred plate and frame, including necessary dismantling of existing floor, excavation and earth work in hard/ dense soil, returning, filling inapproved soil disposal of surplus soil to a distance not exc 50 mtr ,150 mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in faondation, 100 mm thick PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in wall, 10mm thick plaster in cement motar 1:4 internally complete all as specified and directed. Note:The rate quoated by the contractor is including making good the disturbed floor matching to the existing floor.
M&L servicing of Air Break Switch (GOD) 11 KV (200/400 Amp) including, greasing repairing/replacement of U fingers and knives blade as suitable, fixing connecting leads properly with suitable size conductor and checking and repairing the operation complete all as specified. Note : (i) Cost of grease, lubricating oil shall be deemed included in the unit quoted rate. (ii) Site of servicing shall be given as and when felt by GE/ Engineer-in-Charge and nothing extra shall be admissible on account of any misunderstanding. (iii) Servicing shall be carried out by the contractor within time frame allowed by the GE/ Engineer-in-Charge. Therefore, contractor shall provide the sufficient manpower/ electricians including T&P well in advance so that interruptions of electricity can be minimized.
M&L as in repairs earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly in ground in vertical position, earth pit not less than 3.65 Mtr deep below ground level with top edge of the plate not less than 2.90 Mtr below ground level. The earth plate to be connetced with copper earthing strip of size 32mmx6mm thick by means of brazing between copper strip and earth plate min 45 cm in vertical length and copper strip also to be joined by brazing only. The copper earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall include provision of funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ), 3rd layer with tibba sand up to ground level. Earthing shall also include concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 3 of MES Schedule Part-I complete to obtain less than 2 Ohm earth resistance value, complete all as specified. NOTE : (i) Cost of this items includes the scope of earth work, charcoal, salt, PCC, RCC pit cover of required size. (ii) Tibba sand shall be arranged by the contractor at his own and the cost thereof shall be deemed included in unit quoted rate of this item. (iii) Electrical Plate No. 3 refrred in the item above is mainly for earth chamber.
M & L PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation for poles, filling of mass concrete complete all as specified and directed.
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping for old and new poles including form work complete all as specified and directed.
M/s Rohit Construction Co.
BIDAWAT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .