| 1 | L1₹3.8 LAccepted-AOC 36 151 E 73 PERIYAR NAGAR THANGAMAPURIPATTINAM METTUR DAM 2 | METTUR DAM | TAMIL NADU | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.6 L+₹2,070 (0.57%)Rejected-AOC 36 151 E 46 PERIYAR NAGAR THANGAMAPURIPATTENAM METTUR DAM 636 402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹3,000
Closing Date
14 Jun 2024, 2:00 pmClosed
CHIEF ENGINEER/MTPS-I
CHIEF ENGINEER MTPS-I METTUR DAM
MTPSI- ES Circle CI Unit-I Turbine area Replacement of gaskets for displacement type level transmitters and level switches, removal and refixing of transmitters, gauges and switches after calibration, cleaning of all impulse lines and catch pots an
2024_EB_452870_1
CE-MTPS-I-SE-ES-CI-OT 01-2024-25
Open Tender
Electrical Works
Works
15 days
MTPS-I/METTURDAM
AS PER TENDER SPECIFICATION
4 documents required · 4 mandatory
₹0
₹3,000
Yes
24 Feb 2025
7 Jun 2024
15 Jun 2024
7 Jun 2024
14 Jun 2024
7 Jun 2024
7 Jun 2024 - 14 Jun 2024
Amount
Charges for removal of local pressure / temperature gauges and re-fixing them after calibration in Boiler, Turbine & Generator areas.
Charges for removal of pressure/ Vacuum / flow Switches and re-fixing them after calibration in Boiler, Turbine and Generator.
Charges for removal of Pressure Transmitter including disconnecting the control cables, removal of clamps & manifold and re-fixing them after calibration in Boiler, Turbine & Generator areas.
Charges for dismantling, cleaning & replacement of gaskets and re-fitting of Level switches.
Charges for cutting of existing flange from stand pipe (4.5 inch) of LP Heaters stand pipe, grinding the surface in stand pipe, Welding of new flange in the stand pipe, providing new metallic gasket for new flange, fixing of new guided wave radar level transmitters.
Charges for removing and re-fixing of accessories in pneumatic control valves & dampers such as I/P converters, air lock relay, air regulators, positioners and position feedback transmitters sending to lab for testing and receiving tested instruments from lab.
Charges for Replacement of HAD/CAD cylinder (8" Bore and 8 " stroke)which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubing from its location to pocket store.ii) Loading, transporting and unloading of new pneumatic cylinder from central store to field location.iii) Fixing the new pneumatic cylinder and re-fixing the accessories such as air regulator, I/P converter with SS tubing
Charges for Replacement of burner tilt cylinder(10" Bore and 16 " stroke) which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubing from its location to pocket store.ii) Loading, transporting and unloading of new pneumatic cylinder from central store to field location.iii) Fixing the new pneumatic cylinder and re-fixing the accessories such as air regulator, I/P converter with SS tubing.
Charges for removing the terminal connections, replacing the broken terminal blocks and reconnecting the terminal connections and checking various junction boxes at Boiler area.
Charges for rectification and welding of broken doors in junction boxes.
Charges for Opening and cleaning of ½” impulse lines and catch pots in mills, Flue gas, primary and secondary air paths.
Charges for Cutting and welding of takeoff catch pots in mills, flue gas, primary and secondary air path.
Charges for single point cutting and welding of pipe size ½” impulse lines of mills, flue gas, primary and secondary air path including cost of gas, welding electrodes & consumables such as cotton waste, hacksaw blade, etc.
Charges for replacement of defective 1” root valve in turbine area which involves the cutting and welding of 2 joints in 1” CS impulse line .
Charges for replacement of defective drain valve/isolation valve (3/8”) for high pressure transmitters.
Charges for removing existing leaky 3/8” SS impulse line and worn out connectors, cutting and bending the new line as necessary, fixing SS connectors with nut and ferrules in the line and connection back the new line without leaks in High pressure transmitter service
Charges for replacement of defective 1/2” SS instrument valve in various locations of boiler and turbine area.
Charges for removal and re-fixing of all types of RTD/Thermocouples
Charges for Overhauling of servo Valves for HP/LP Bypass system
Copper Washer (Sl. No: 1)
Teflon O-ring (Sl. No : 3 )
Gasket (Champion 54 grade / Klinger 1000 grade) size 280 x 280 mm. (Work Sl. No: 4)
2.5 Sq.mm Elmax Terminal Block (Work Sl. No: 9)
2.5 mm CS welding rod electrode (90 Nos./Box)(Work Sl. No : 5,10 to 12 & 14)
Gas cutting for takeoff catch pot and 1/2” impulse line, bed etc… (Work Sl. No:12)
Pad lock & Hinge (Work Sl. No: 10) ( 5 Nos/each)
Consumable cost such as Teflon Tape, PVC Insulation tape, Cotton Waste, Emery Sheet, Glass putty, Rustolene, bolt and nuts, Anabond, etc. (Work Sl. No.: 1 to 12,15 to 19 ) (Lumsum)
RATHNA AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .