Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80,550Admitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹89,250+₹8,700 (10.8%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Asif Engineering Works L2 | City Engineering Works L1 |
|---|---|---|---|---|---|
| 1.00Minor Repairs to 100kVA Unbalanced Type Servo Voltage Stabilizer by way of following works: | |||||
| 1.01 | P& F of Single-Phase Servo Voltage Stabilizer Control Card with Double LED display with the below mentioned features:
a) True RMS Metering – Voltage, Current, Frequency.
b) Over Load Protection with settable Cut-off Time & also with respect to Intensity of occurred fault.
c) Over Voltage, Under Voltage protection with settable Cut-off Voltage & Time.
d) Calibration type.
e) Reverse Phase Protection or Correction.
f) Input High/Low Cut by way of replacement of Old Control Cards complete as per site requirement. The job includes all sorts of charges on account of skilled & unskilled labour, tools and tackles etc for the complete job as per site requirement. (Reputed make) | 3 | Nos | 9,200 ₹27,600 | 8,600 ₹25,800 Lowest |
| 1.02 | Urgent Electrical works of minor repairs to 100KVA Servo Voltage Stabilizer, AC Drive for 3.15MVA OLTC Power Transformer and Segregation of auxiliary Circuit for HT Panels, Lightening and EOT crane along with other allied works at WSS Tangnar Stage-2nd.Providing and fitting of Hylum Sheet of size 12" x 12'' along with nuts & bolts for fixing of above control card in the servo stabilizer if required as per site requirement. | 3 | Nos | 3,000 ₹9,000 | 2,800 ₹8,400 Lowest |
| 1.03 | Providing and fitting of 1mm2 PVC insulated 1100V flexible copper cable (FRLS) for the auxiliary wiring of the above Control Cards & AC Drive as per site requirement (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab or Equivalent). | 20 | Mtrs | 320 ₹6,400 | 270 ₹5,400 Lowest |
| 2.00 | Providing, fitting, Installation, Testing & Commissioning of 80Amp 4-Pole MCCB conforms to IS/IEC 60947-2 & IEC 60947-2 on ST Pole near Auxiliary 63kVA Transformer having following specifications:
Type/Rating:DU100D
Make: L&T or equivalent
Breaking Capacity: 18 kA (Icu)
Thermal Release Range : 63A - 80A
Adjustable Overload Setting : 0.8 -1.0 ln
Voltage: 415V
Frequency : 50 Hz
Poles: 04
Usage : outside/external
Spreader Terminals : Set of 08
SS Ecclosue : Size I
Rotary Handle : Direct ROM
Din Rail Kit : 01
The job is inclusive of providing, fixing and tightening of nuts, bolts & washers, ST pole clamp, connecting of main incoming and outgoing connections as per site requirement, then finally testing of the MCCB on full load at site. The job also includes cost on a/c of all transportation charges, tools & tackles and skilled labour component. | 2 | Jobs | 9,000 ₹18,000 | 8,000 ₹16,000 Lowest |
| 3.00 | Segregation of auxiliary circuit for HT Panels, Lightening and EOT crane circuit at WSS Tangnar Stage-2nd by way of utilizing the services of Service engineer or senior technician along with helper technicians well versed with 33Kv & 11kV electric circuitry, gadgets, C&R, Ht Motor control panels, LT panels etc as per site requirement. The job includes all sorts of charges on account of Service engineer or senior technician along with helper technicians, tools and tackles etc for the complete job as per site requirement for refitting & shifting of cables etc. | 1 | Jobs | 1,600 ₹1,600 | 1,500 ₹1,500 Lowest |
| 4.00Providing & Fitting of AC Drive mechanism with allied works in order to ensure tap of 3.15 MVAS OLTC power transformer automatically comes to the minimum set position in case of power outage by way of fitting of below mentioned items as per site requirement also the job includes all sorts of charges on account of skilled & unskilled labour, tools and tackles etc for the complete job as per site requirement: | |||||
| 4.01 | Providing, fitting and setting of ON delay (0.3s - 30hrs) 240V AC electronic Timer (L&T GIC or equivalent make). | 1 | Nos | 250 ₹250 Lowest | 250 ₹250 Lowest |
| 4.02 | P/ F of 9A AC-3, 3-Pole 3-Phase 415V AC Power Contactor with 230-240V coil voltage along with 2 NO + 2 NC Front Mounting Add on Auxiliary Contact Block (L&T or equivalent make). | 2 | Nos | 900 ₹1,800 Lowest | 900 ₹1,800 Lowest |
| 4.03 | Providing, fitting and setting of 3-Phase 415V auto reset single phase preventor 70V or less unbalance & 2 C/O DIN mounted (L&T/ Minilec/ BCH or equivalent make) | 1 | Nos | 1,600 ₹1,600 | 1,400 ₹1,400 Lowest |
Tender Value
₹87,527
EMD Value
₹1,750
Closing Date
10 Jun 2025, 4:00 pmClosed
EXECUTIVE ENGINEER JAL SHAKTI MECHANICAL DIV SGR
OFFICE OF THE EX ENGINEER JAL SHAKTI MECH DIV SGR
Urgent Electrical works of minor repairs to 100KVA Servo Voltage Stabilizer, AC Drive for 3.15MVA OLTC Power Transformer and Segregation of auxiliary Circuit for HT Panels, Lightening and EOT crane along with other allied works at WSS Tangnar Stage-2
2025_PHE_272953_1
PHE/MECH/e-NIT-60 of 02/2025
Open Tender
Electrical and Maintenance Works
Item Rate
20 days
Tangnar 2nd
As Per NIT
2 documents required · 2 mandatory
₹100
EXECUTIVE ENGINEER JAL SHAKTI MECHANICAL DIV SGR
₹1,750
27 Dec 2025
20 Feb 2025
11 Jun 2025
20 Feb 2025
10 Jun 2025
20 Feb 2025
Amount
Minor Repairs to 100kVA Unbalanced Type Servo Voltage Stabilizer by way of following works:
P& F of Single-Phase Servo Voltage Stabilizer Control Card with Double LED display with the below mentioned features: a) True RMS Metering – Voltage, Current, Frequency. b) Over Load Protection with settable Cut-off Time & also with respect to Intensity of occurred fault. c) Over Voltage, Under Voltage protection with settable Cut-off Voltage & Time. d) Calibration type. e) Reverse Phase Protection or Correction. f) Input High/Low Cut by way of replacement of Old Control Cards complete as per site requirement. The job includes all sorts of charges on account of skilled & unskilled labour, tools and tackles etc for the complete job as per site requirement. (Reputed make)
Urgent Electrical works of minor repairs to 100KVA Servo Voltage Stabilizer, AC Drive for 3.15MVA OLTC Power Transformer and Segregation of auxiliary Circuit for HT Panels, Lightening and EOT crane along with other allied works at WSS Tangnar Stage-2nd.Providing and fitting of Hylum Sheet of size 12" x 12'' along with nuts & bolts for fixing of above control card in the servo stabilizer if required as per site requirement.
Providing and fitting of 1mm2 PVC insulated 1100V flexible copper cable (FRLS) for the auxiliary wiring of the above Control Cards & AC Drive as per site requirement (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab or Equivalent).
Providing, fitting, Installation, Testing & Commissioning of 80Amp 4-Pole MCCB conforms to IS/IEC 60947-2 & IEC 60947-2 on ST Pole near Auxiliary 63kVA Transformer having following specifications: Type/Rating:DU100D Make: L&T or equivalent Breaking Capacity: 18 kA (Icu) Thermal Release Range : 63A - 80A Adjustable Overload Setting : 0.8 -1.0 ln Voltage: 415V Frequency : 50 Hz Poles: 04 Usage : outside/external Spreader Terminals : Set of 08 SS Ecclosue : Size I Rotary Handle : Direct ROM Din Rail Kit : 01 The job is inclusive of providing, fixing and tightening of nuts, bolts & washers, ST pole clamp, connecting of main incoming and outgoing connections as per site requirement, then finally testing of the MCCB on full load at site. The job also includes cost on a/c of all transportation charges, tools & tackles and skilled labour component.
Segregation of auxiliary circuit for HT Panels, Lightening and EOT crane circuit at WSS Tangnar Stage-2nd by way of utilizing the services of Service engineer or senior technician along with helper technicians well versed with 33Kv & 11kV electric circuitry, gadgets, C&R, Ht Motor control panels, LT panels etc as per site requirement. The job includes all sorts of charges on account of Service engineer or senior technician along with helper technicians, tools and tackles etc for the complete job as per site requirement for refitting & shifting of cables etc.
Providing & Fitting of AC Drive mechanism with allied works in order to ensure tap of 3.15 MVAS OLTC power transformer automatically comes to the minimum set position in case of power outage by way of fitting of below mentioned items as per site requirement also the job includes all sorts of charges on account of skilled & unskilled labour, tools and tackles etc for the complete job as per site requirement:
Providing, fitting and setting of ON delay (0.3s - 30hrs) 240V AC electronic Timer (L&T GIC or equivalent make).
P/ F of 9A AC-3, 3-Pole 3-Phase 415V AC Power Contactor with 230-240V coil voltage along with 2 NO + 2 NC Front Mounting Add on Auxiliary Contact Block (L&T or equivalent make).
Providing, fitting and setting of 3-Phase 415V auto reset single phase preventor 70V or less unbalance & 2 C/O DIN mounted (L&T/ Minilec/ BCH or equivalent make)
Providing & Fitting of 230 V AC Single Phase to Three Phase VFD AC Drive for 1.5 KW / 2 HP as per following specifications: Input Phase : 1 Phase Output Phase : 3-Phase Input Voltage : 230 V AC Output Voltage : 230V AC Output Current : 7 Amp Output Power : 1.5 KW / 2 HP Frequency Control range : 0.1~400 Hz Acceleration and Deceleration Time : 0.0-3600.0 Sec (4 Settings) Output Type : 1 Relay Output, 1 Analog Output(0-10V/0-20mA); 1 Open collector output Input Type : 5 (PNP/NPN) Inputs, 1 POT Input, 1 Analog Inputs(0-10V/0-20mA/4-20mA) Protection Functions: Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error (Preferred Make: Selec or equivalent make)
Providing, Fitting and laying of 2.5 mm2 4-Core Armoured Solid or Balance Stranded Copper Conductor Cable, XLPE Insulated, PVC Inner sheathed, armoured 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab or Equivalent)
Asif Engineering Works (BID ID -2379583)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .