| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.0 L+₹37,003 (0.81%)Rejected-Finance 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹46.6 L+₹91,217 (2.00%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹47.2 L+₹1.5 L (3.33%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹48.2 L+₹2.6 L (5.64%)Rejected-Finance OLD PAHARGAON POLY TECHNIC ROAD DOLLYGUNJ SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹45.1 L
EMD Value
₹90,300
Closing Date
23 Nov 2023, 6:00 pmClosed
Garrison Engineer Haddo, Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDITION / ALTERATION TO TECHNICAL WING OF HQ NAVCC AT NSRY AND ADDITION / ALTERATION AND SPECIAL REPAIRS TO PASSAGE SHED AT NKG, VIJAY BAUGH AND CERTAIN SANCTIONED WORKS UNDER GE HADDO, PORT BLAIR
2023_MES_621964_2
8782/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
Class D and Category a(i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹90,300
Yes
8 Jan 2024
11 Nov 2023
30 Nov 2023
11 Nov 2023
23 Nov 2023
18 Nov 2023
13 Nov 2023 - 16 Nov 2023
Amount
Demolition of reinforced cement concrete of any description as in chajja/facia etc and in any position not otherwise specifically provided for incl cutting reinforcement carefully without disturbing the existing structure complete all as specified and as directed.
Demolition of cement conrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5mm graded aggregate) as in sub base 25mm thick complete all as specified and directed.
M&L for vitrified light shades tiles 9 to 10 mm thick (square/ rectangular), area of each tile not exceeding 0.36 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for vitrified light shade tiles 9 to 10 mm thick (square/ rectangular) area of each tile not exceeding 0.36 Sqm as in skirting / dados etc., laid over and including 10mm thick screed bed in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for design mix reinforced cement concrete M-30 (using 20mm graded stone aggregate) as in Coloumn, pillars, piers, posts and struts etc complete all as specified and directed.
M & L for fair finished Square, Rectangular and Polygonal formwork to sides of pillars, posts, struts, piers columns and stanchions complete all as specified and directed.
M & L for design mix reinforced cement concrete M-30 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers etc complete all as specified and directed.
M & L for design mix reinforced cement concrete M-30 (using 20mm graded stone aggregate) as in Chajjas complete all as specified and directed.
M & L for fair finished surface of concrete flat formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M & L for flat formwork to fair finished surface of concrete flat, sides and soffits of floors or roof beam, beam hauchings, griders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splays between floors and beam complete all as specified and directed.
M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in cement mortar 1:6 complete all as specified and directed.
M&L precast cement concrete block masonry exc 10 cm width with hollow block PCC 1:3:6 type C1 (using 16 mm graded stone aggregate) and setting in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) including mixing water proofing compound on concrete/block masonary surfaces and finished even and smooth without using extra cement complete all as specified and directed.
M & L for 10mm thick plaster in CM 1:6 on fair faces of concrete/PCC block surfaces of walls finished even and smooth (without using extra cement) complete all as specified.
M&L for preparation of newly plastered surfaces of walls by 3mm wall care putty and applying two coats of distemper oil bound distemper over a coat of primer including levelling the surface complete all as specified and as directed.
M&L for preparation of newly plastered external wall applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators, partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
SUPPLY ONLY 4.0 mm thick sheet glass, ordinary quality and glazing with aluminium glazing clips in aluminium window shutter not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
SUPPLY ONLY 5.5 mm thick sheet glass, ordinary quality and glazing with aluminium glazing clips in aluminium door shutter exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Material and labour for 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to aluminium / timber frame work complete all as specified and directed.
S&F anodised aluminium grill of approved pattern, anodised powder coated, cut to required size and shape, fixed in position with aluminium beading & frame made of aluminium F-section fixed to aluminium windows/ventilators complete all as specified and as directed.
Disconnecting existing water tanks setting aside or lowering if required for repairs, cleaning etc., and hoisting if required, reconnecting and refixing in position of capacity exc 500 litres but not exc 1000 litres complete all as specified and directed.
M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., 6mm thick non-asbestos fibre cement building design boards fixed or laid/ inserted to aluminium frame work with screws including prepration and finishing of surface with two coats of oil bound distemper complete all as specified and as directed.
M&L Aluminium composite panel sheet of 3.0mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30.0micron fixed over frame of aluminium tabular section 50x25mmx 2.0mm thick, having panels not exc 1200x1200mm with necessary silicon filling, in approved pattern as in column, beam, wall etc at any height with necessary scafolding as per site requirement etc complete as specified and as directed. Make : Umiya Flexifoam Pvt Ltd (Brand : "Flexibond") / Aludecor / Alstrong / Alcobond
M&L PVC insulation panels (thickness of insulation panel 10mm) with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 & 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from sofit at approm 900mm centre to centre with GI cleat and steel expansion fastner with and incl ceiling section(not exceeding 1.2m length) of 0.55mm thickness having curled web of 50mm and flange of 26mm each with clips of 10.5mm fixed to the intermediate channel at 457mm centre to centre and incl 6mm thick Gi hangers adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40 x 3mm size long and expansion hold fasteners 12.5mm dia 40mm long etc complete all as specified as per specification and drawing. Make : M/s Rajshri Plastiwood / M/s Kumar Arch Tech Pvt Ltd / M/s Accura Polytech Pvt Ltd / Venus / King / Gyproc
Dismantling Framed work timber scantlings 40sqcm and over in section, in any position complete all as specified and as directed.
Dismantling Unframed work timber scantlings 40 sqcm and over in section, in any position complete all as specified and as directed.
Dismantling Unframed timber scantlings in fillets, rails, posts, rafters, purlins,etc under 40 sqcm in section, complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern in roof coverings complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed withearth around, in layers not exceeding 25 cm watering and removing surplus soil to a distance n exc 50m and making good surface as in hard/dense soil complete etc. complete all as specified and directed.
M & L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in filling, foundation and mass concrete complete etc. complete all as specified and directed.
M & L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in filling, foundation and mass concrete complete etc. complete all as specified and directed.
S&F for joist, channel, angle or tee sections, fixed independently, without connecting plates etc (cut to ordinary length i.e., with in 20 mm of the length indicated conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
S&F for mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.
S&F for pre painted Galvalume aluminium zinc coating GI based corrugated/trapezoidal section of steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa (AZ 150) as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F for pre painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, ridge etc fixed with self tapping screws complete all as specified and directed.
M&L for aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering complete all as specified and directed.
M&L for mild steel work as in hold fasts, bands, straps, brackets/clamps for eaves/barge boards and valley gutter and similar articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer first quality complete all as specified and as directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out soft / loose soil complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
S&F for glossy finished chequered cement concrete tiles 30cmx30cmx25mm thick set jointed with grey cement and pigment and pointed in neat cement slurry including 15 mm thick screed bed of CM(1:6) in floors complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed
S&F 110mm PVC (SWR) grade single socketed pipes, in any length pipes with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and as directed.
S&F PVC (SWR) 110mm dia bend of any radius and jointed with approved adhesive complete all as specified and directed
S&F PVC (SWR) 110mm dia bend with acess door any radius complete all as specified and directed
Taking down carefully copper/aluminium point wiring for light, fan, socket or power point etc complete with all fittings and fixtures such as switch piano, ceiling rose switch, socket, Pendents etc including making good surface of wall, ceiling etc complete all as specified and directed.
Taking down fuse Unit/DBs, 415 Volt/230 Volt complete all as specified and directed
Taking down old aluminium sub main wiring of any size complete all as specified and directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) and accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for the following:- Make of wire : Polycab/Gloster/Anchor/ Havells/Finolex
ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on independent board.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on same board with other switches.
M&L for Point wiring complete with 4 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) and accessories concealed in walls/ceilings etc., including provision of PVC insulated 4 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board.
All as per Item No.58 here-in-before but, ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on same board.
S & F modular switch, 6 Amp, one way, 1 module 230 V, AC Circuit all as directed Make : ROMA (Anchor)/Havells / Legrand/Simens
S & F modular switch, 16 Amp, one way, 1 module, 230 V, AC Circuit all as directed Make : Anchor/Cona/ Legrand
S&F socket outlet, modular type, 1 way 6 Amps, 3 pin flush type 230 Volts AC circuit complete all as specified and as directed. Make: Roma (Anchor) / Havells/Simens / Legrand
S & F socket outlet, 2 in 1, 6/16Amp,3 pin, modular type, flush type universal all as directed Make : ROMA (Anchor)/Havells (Crabtree)/Legrand
M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including rigid non-metallic 25mm dia PVC conduit and conduit accessories concealed in wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. Make : Polycab/Havells/Finolex/Gloster/Anchor
M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including rigid non-metallic 25mm dia PVC conduit and conduit accessories concealed in wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. Make : Polycab/Havells/Finolex/Gloster/Anchor
M&L for Sub main wiring complete with two runs (1P+1N) of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including rigid non-metallic 25mm dia PVC conduit and conduit accessories concealed in wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 10.0 Sqm copper conductor, One run of 10.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S&F DB VTPN sheet metal enclosure double door suitable for incoming upto MCCB 160 Amps/200 Amps & outgoing MCB TP / SP (IP-43) Protection Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete all as specified and directed. Make : Indo Asian /Havells/L&T/C&S
S & F single pole and neutral sheet steel powder coated Distribution board IP -43 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 08 ways,including taking down old unserv DB of any type /rating and making good to the distrubed surface /walls. Make: Indo Asian/Havells/L&T/Legrad/C&S
S & F single pole and neutral sheet steel powder coated Distribution board IP -43 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 12 ways,including taking down old unserv DB of any type /rating and making good to the distrubed surface /walls. Make: Indo Asian/Havells/L&T/Legrad/C&S
Supply and Fixing in repair for 4 pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed Make : Indo Asian/Havells/L&T/C&S
S&F MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed. Make : Indo Asian /Havells/L&T/C&S
S&F MCB, SPN, "C" series, 240 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed. Make : Havells/L&T/Indo Asian/Legrand/C&S
S&F AC starter switch of capacity 25 Amps working on 240 Volts, AC supply with 15 Amps plug top and 15 Amps sockets suitable for split type airconditioner complete all as specified and as directed. MAKE: Havells (Cat part No. ACTO252504 )or Philips/Bajaj/CG
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 70 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for HDPE DWC (Double wall corrugated) pipe of size 63mm (Outer diameter) x 50mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: (1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. (2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
M&L for cutting channels, grooves or rebates with or without reinforcement n exc 15cm girth, and trimming surface of the wall column surface all as specified and as directed by Engr-in-Charge
S & F fixing for ceiling rose, 3 phase, PVC polycarbonate, isolated body complete all as specified and directed
S&F ceiling fan 220 volts, 50Hz, mettalic body 1200mm sweep including all fixing arrangement complete all as specified and directed. Make : CG Model No. Super Briz or equivalent to Havells / Bajaj / Usha / Orient
S&F stepped type electronic fan regulator flush type on the existing / new phenolic laminated sheet etc. as reqd complete all as specified. Make:Roma (Anchor)/Legrand/Simens/Havells
S&F 15 Watts, 220 Volts recess mounting LED ceiling light fitting, yellow/white colour, round/square shape as requirement at site, made from die-cast aluminuim and CRCA covering, powder coated in white colour suitable for armstrong/grid ceiling complete with separate electronic dirver complete all as specified and directed. Make : Philips, Model : Astra Max Metal Panel. CG Cat Part No. CDR-205-15-57-SL-NWH equivalent make of Havells/Luker NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
S&F and testing LED recessed mounted 595mm x 595mm luminaire with high transmitive diffuser of cap 40 watt, with longer life and less maintenance including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make : Luker Model No : LKM 2240 of any colour (WH/NWH/WW) as required or equivalent make in Philips / CG / Havells NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
Hindustan Traders
CARTWHEEL CONSTRUCTION
M/S VISHAL CONSTRUCTION
LOOK UP ENTERPRISES
Reliance Sales Agency
V KARTHICK
SHUBHAM SHANKAR GAIKWAD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .