| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAdmitted-Finance 1ST FLOOR NO 55 5TH CROSS BANASAWADI MAIN ROAD BANASAWADI BENGALURU BANGALORE URBAN BENGALURU KARNATAKA 560043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹3.5 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical CUNNINGHAM ROAD BANGALORE KARNATAKA 560052 | BENGALURU URBAN | KARNATAKA | 560052 | - | - | Rejected-Technical Bidder is not qualified in 1.1 i.e. work experience. Bidder has not uploaded filled Excel sheet(Format 2 of NIT). Class 1.3.5 and 15.10 of NIT is not meeting |
| Sl No | Description | Qty | Unit | Puthur Infotech Private Limited L1 |
|---|---|---|---|---|
| 1.00Supply of Material, Spares & Software required for Networking /hardware/ Servers | ||||
| 1.01 | 20 ports 10/100/1000Base-T ports + 4 ports Combo 10/100/1000Base-T /SFP Ports + 4 ports 10G SFP+ ports L3 Stackable Managed switch as specified in Annexure-I | 2 | Nos | 1,99,361 ₹3,98,722 Lowest |
| 1.02 | 24 Ports 10/100/1000Mbps + 4 ports SFP Managed Ethernet Switch as specified in Annexure-II | 15 | Nos | 56,592.8 ₹8,48,892 Lowest |
| 1.03 | 1000 (or Higher) Base-LX Single-Mode, 10KM SFP/ SFP+ Transceiver (SFP/SFP+ module) as Specified in Annexure-III | 24 | Nos | 2,508.09 ₹60,194.16 Lowest |
| 1.04 | LIU 24 PORT Rack Mountable (1U/1.5U) – Fully Loaded with 2x6 Duplex Adapter (SC) panel + 12 nos of SC SM duplex adapter module on each Adapter as specified in Annexure-IV | 20 | Nos | 4,951.87 ₹99,037.4 Lowest |
| 1.05 | PIGTAIL SC SM SIMPLEX LENGTH- 1m as specified in Annexure-V | 240 | Nos | 167 ₹40,080 Lowest |
| 1.06 | PATCH CORD LC-SC SM DUPLEX LENGTH- 1m as specified in Annexure-VI | 40 | Nos | 1,028.96 ₹41,158.4 Lowest |
| 1.07 | PATCH CORD LC-SC SM DUPLEX LENGTH- 3m as specified in Annexure-VI | 20 | Nos | 1,222 ₹24,440 Lowest |
| 1.08 | PATCH CORD SC-SC SM DUPLEX LENGTH- 1m as specified in Annexure-VI | 40 | Nos | 1,028.96 ₹41,158.4 Lowest |
| 1.09 | PATCH CORD SC-SC SM DUPLEX LENGTH- 3m as specified in Annexure-VI | 20 | Nos | 1,222 ₹24,440 Lowest |
Tender Value
₹2.9 Cr
EMD Value
₹5.9 L
Closing Date
2 Sept 2024, 5:00 pmClosed
Project Director, Kaiga - 5 and 6
Project Director, Kaiga - 5 and 6
Establishing slash extending IT Networks at Kaiga 5 and 6 project and providing Facility Management Support for existing IT networks and devices at Kaiga- 5 and 6 Site
2024_NPCIL_201862_1
CPPP/2024/042
Open Tender
Information Technology
Item Rate
730 days
Kaiga 5 and 6
Refer NIT - 1.1, 1.2 of PQC
4 documents required · 4 mandatory
₹0
₹5.9 L
Office of Head CTC, Kaiga Site
21 Sept 2024
8 Aug 2024
4 Sept 2024
8 Aug 2024
2 Sept 2024
20 Aug 2024
8 Aug 2024 - 14 Aug 2024
17 Aug 2024
Amount
Supply of Material, Spares & Software required for Networking /hardware/ Servers
20 ports 10/100/1000Base-T ports + 4 ports Combo 10/100/1000Base-T /SFP Ports + 4 ports 10G SFP+ ports L3 Stackable Managed switch as specified in Annexure-I
24 Ports 10/100/1000Mbps + 4 ports SFP Managed Ethernet Switch as specified in Annexure-II
1000 (or Higher) Base-LX Single-Mode, 10KM SFP/ SFP+ Transceiver (SFP/SFP+ module) as Specified in Annexure-III
LIU 24 PORT Rack Mountable (1U/1.5U) – Fully Loaded with 2x6 Duplex Adapter (SC) panel + 12 nos of SC SM duplex adapter module on each Adapter as specified in Annexure-IV
PIGTAIL SC SM SIMPLEX LENGTH- 1m as specified in Annexure-V
PATCH CORD LC-SC SM DUPLEX LENGTH- 1m as specified in Annexure-VI
PATCH CORD LC-SC SM DUPLEX LENGTH- 3m as specified in Annexure-VI
PATCH CORD SC-SC SM DUPLEX LENGTH- 1m as specified in Annexure-VI
PATCH CORD SC-SC SM DUPLEX LENGTH- 3m as specified in Annexure-VI
O. F. Cable 12F Outdoor - Armoured Unitube/Multitube SM - HDPE sheath as specified in Annexure-VII
O.F. Cable 6F Outdoor – Armoured Unitube SM – HDPE Sheath as specified in Annexure - VIII
CAT6 UTP 23AWG Solid:305M (Roll of 305 Meters) as specified in Annexure-IX
CAT6 UTP 23AWG Solid Outdoor – Armoured underground cable role: 305M (Roll of 305 Meters in each drum) as specified in Annexure- X
Patch Panel Cat 6 UTP Keystone Type-24 Port-Fully Loaded as specified in Annexure-XI
IO Box (Back Box & Face plate) fully loaded with Single/Dual Jack Cat 6 keystone (Information Outlet for Cat6/Cat6A/Cat7, square) white color as specified in Annexure-XII
RJ-45 connectors (male) for crimping of CAT cables (100 no in a pack)
RJ-45 Coupler (CAT cable extender); Female to Female connector
CAT6 UTP 24AWG PATCH CORD:1M, Plug 30U’ Snagless as specified in Annexure-XIII
CAT6 UTP 24AWG PATCH CORD: 3M, Plug 30U’ Snagless as specified in Annexure-XIII
Wall Mount 6U x 550 x 450 D, with Standard Accessories like fan, PDU, cable manager etc. as specified in Annexure-XIV
Wall Mount 9U x 550 W x 450 D, with Standard Accessories like fan, PDU, cable manager etc. as specified in Annexure-XIV
Wall Mount 15U x 550 W x 450 D, with Standard Accessories like fan, PDU, cable manager etc. as Specified in Annexure-XIV
42U Network Enclosure Frame-600X800-STEEL with accessories like fan, PDU, cable manager etc. as specified in Annexure-XV
32mm HDPE pipe (non-flexible) with Coupling/collar (Black Colour preferred) & clamps, as specified in Annexure-XVI
2 inch Casing & Capping SSI (White colour)
1 inch Casing & Capping SSI (White colour)
Box type hard PVC Casing & Capping (75mmx75mm) / FRP (Fiber Reinforced Plastic) Cable tray with cover.
1 inch Flexible pipe/hose, Gray Colour
1 inch Hard PVC pipe / Conduit with collar, coupler and clamps.
1 inch Grip PVC Box
5 inch Hard PVC pipe / Conduit with coupler & bend
2 inch Screws Box (500 Nos)
GI Cable Tray (perforated) with locked cover/enclosure and consumables, as specified in Annexure-XVII
2 feet Hard Metal Cable Root Markers/Indicators as specified in Annexure-XVIII
5 inch Locking Tags (Cable tie) for Securing Cables (Pack of 100 Nos)
UTP Cable Marking Ferule with Alphabets (A-Z) and Digits (0-9)
Wood piece for Screwing in wall- 1.5 inch (100 in 1 packet)
2 inch hard metallic nails (100 nos in each box)
Printer Cartridge Supply for the different model of Printers as per Annexure - XIX Note- This item shall be supplied based on make & model of Printer used at project site as instructed by EIC.
SMPS (Power Supply Module) of standard design for PCs used at Site . Note- This item shall be supplied based on make & model of PC used at project site as instructed by EIC.
NIC PCIe GE LAN Card – Single/ Dual port. Note- This item shall be supplied based on make & model of PC used at project site as instructed by EIC.
RAM DDR4/5 – 8GB/16 GB Note- This item shall be supplied for upgradation, based on make & model of PC used at project site as instructed by EIC.
Work station computer for Simulation & Virtualisation, testing, development of software before deployment over main server as per specification in Annexure -XX
Portable device like surface or mac for configuration, update and patching of active components like switches, routers, firewall, etc as per Annexure -XXI
Supply of Windows Server Data Center Edition-2022 or Latest, 64 bits; For Dual Processor each having 24 cores; Total 48 core Liscence (16 cores x 3 packs), Perpetual licence as per Annexure -XXII
Supply of Windows Server Data Center Edition-2022 or Latest, 64 bits; For Dual Processor each having 12 cores; Total 24 core Liscence (16 cores+8 core), Perpetual licence as per Annexure - XXII
Supply of MS CALS- 5 licence, Perpetual licence as per Annexure - XXIII
Supply of Adobe Cold Fusion Standard edition, Perpetual licence as per Annexure-XXIV
Supply of MS SQL Data Base Server standard Edition-2022 or Latest for 2 cores, Perpetual license as per Annexure -XXV
Supply of NMS & NAC for IT Network, at least 5 years / Perpetual license as per Annexure - XXVI
Cylindrical fibre encloser outdoor underground having 4 cable entry upto 12/24F for Splicing, as per Annexure-XXVII
Rectangular fibre encloser having 4 cable entry upto 6/12/24F for Splicing, as per Annexure-XXVIII
Media Converter-Duplex, as per Annexure-XXIX
Cement ring along with cover (diameter 1m, 0.4m length & thickness not less than 4 cm) for keeping underground fiber encloser while making joint / splicing of OFC. Note- This item shall be supplied only as & when the actual requirement found.
Rack Mounted KVM Switch with Display & Tray, as per Annexure-XXX
2X1.5 Sq mm Armoured Fire Alarm Cables as per Annexure-XXXI
2X2.5 Sq mm Armoured PA System Cable as per Annexure-XXXII
Installation/ Commissioning of new Network & interconnecting with the existing Network at Project site
Earth work excavation in all sorts of soil for laying cables at kaiga site area. The width of the trench shall be 30 cm and average depth 50cm.The cost is inclusive of refilling the trench with the excavated soil after laying of HDPE as specified by EIC.
Laying of HDPE pipe with coupling in the excavated trench/tray.
Drawing of Cables through the per meter of HDPE Pipe/ PVC Pipe/Conduit/Tray
Installation of Casing & Capping then drawing CAT cable through it on per meter length of casing.
Installation of Ceiling/ Wall mounted GI Tray with locked cover/enclosure
Mounting of U Racks (6U/9U/15U/42U) with standard accessories and loading with PDU, Switches, LIU, Patch panel, Cable manager and connect these device with network cables
Termination/Splicing of OFC cores with Pigtails
Crimping/termination of each CAT Cable on Patch Panel / RJ45 Connector/ Information-outlet (jack keystone)
Installation/Mounting of an IO box fully loaded with keystone jack & face plate followed by connection to cable inside Casing Capping .
Laying/installing/mounting of PVC hard pipe/conduit with interconnected Grip PVC Box (use flexible pipe/hose on turning/bends or wherever required).
Installation of a 2 feet route cable marker with cubical concrete base of edge 15cm.
One Time Installation Charges for integration of different servers with network devices, deployment of OS/ VM over the physical servers and interconnecting with the existing network. [Installation and configuration of (1) Windows Server Data Centre Edition-2022; (2) Adobe Cold Fusion Standard edition; (3) MS SQL Data Base Server standard Edition for 4 cores;(4) NMS & NAC for IT Network, with activation using suitable licence/ key; integrating these with relevant Software to work as complete data centre with monitoring & logging facilities, etc under the instruction of EIC. Submit the commissioning & configuration report along with the network scanning, testing and performance report complying with the international/ national standards for the data traffic and security to EIC in addition to imparting the handholding training]. Note - Physical Machines /Hardware required will be provided by NPCIL and Proportional payment may be made in case of partial work during entire tender period.
Annual /Comprehensive Maintenance (AMC) for hardware/ machines out of warranty:
AMC Charges for Desktop Computers (including No of Device * 24)
AMC Charges for Laptop Computers (including No of Device * 24)
AMC Charges for Colour Multi-Function Printers (MFP) (including No of Device * 24)
AMC Charges for Monochrome Printers (including No of Device * 24)
AMC Charges for Multi-Function Copier Printer with maintenance of Pressure Roller, Teflon Sheet, Paper Pickup roller, LS Unit, etc (including No of Device * 24)
AMC Charges for Multimedia Projectors (including No of Device * 24)
AMC charges for All in One Desktop Computers (including No of Device * 24)
Providing Facility Management Manpower Support
Providing Software Developer
Providing Senior Administrator for Windows, Linux & Data Base
Providing Network support Engineer
Providing Engineer for Resources Management and Backup
Providing IT & Comm Assets Support Technician
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .