Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹8.4 L
EMD Value
₹25,000
Closing Date
26 Sept 2025, 10:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mangalore Electricity Supply Company Limited
Smt Varsha CHawan
ESTIMATION FOR THE REORIENTATION OF F3 SIDDARUDANAGARA FEEDER BY REPLACING OVERHEAD RABBIT TO 11KV 240 SQMM UG CABLE TO AVOID THE INTERRUPTION FROM F2 TALUK OFFICE F4 LAXMIPURA F5 BABALLI FEEDERS AT SEEGEBAGI STATION IN UNIT2 CSD BHADRAVATHI ON TOTAL TURN KEY
MESCOM/2025-26/EL/WORK_INDENT365
MESCOM/2025-26/EL/WORK_INDENT365
Open
Electrical
Two Tender Document System(Two Cover)
MESCOM Superintending Engineer Circle Office Shivamogga
7 documents required · 7 mandatory
The bidder should have carried out not less than 200 meters of HT UG cable line work, or 1 km of HT Electrical Line works on a Partial Turnkey basis / Total Turnkey or Self-Execution at MESCOM jurisdiction only in any one of the previous three financial (2022-23 OR 2023-24 OR 2024-25) years to any distribution companies in Karnataka
The bidder shall furnish the self-declaration stating that number of Turnkey Works/no pending Turnkey works in hand in MESCOM. Along with self-declaration, the concerned Executive Engineer shall certify pending works (ANX-XIII/XIV/XV- enclosed)
The bidder shall upload original scanned copy of EPF/ESI registration/ GST Registration/ PAN number/Certificate of labour Department
The bidder should possess valid Super Grade / Class-I Electrical Contractor License issued by the competent authority of Govt. of Karnataka
The bidder should not have been blacklisted/defaulted by any Government Department / Power Utilities. And undertaking on stamp paper value not less than Rs. 100/- to be uploaded in this regard
The Annual Turnover of the bidder shall be not less than 100% of the amount put to tender in any one of the three FY years i.e., 2022-23 OR 2023-24 OR 2024-25. Supporting documents must be uploaded
The bidder must upload the evidence for having Cash Credit/ Overdraft facility or latest Solvency Certificate from a Scheduled Commercial/Nationalized Bank (On or after the date of tender notification) for amount not less than Rs. 3.28 Lakhs
₹500
₹25,000
11 Sept 2025
11 Sept 2025
30 Sept 2025
18 Sept 2025
Reorientation of F3 Siddarudanagara feeder by replacing overhead rabbit to 11kV 240 sqmm UG cable to avoid the interruption from F2 Taluk office F4 Laxmipura F5 Baballi feeders at Seegebagi station in unit2 CSD Bhadravathi
02 87 405-11kV, 3 Core, XLPE HTUG Cable (ROUND Armoured) 240sqmm
02 88 304-Heat Shrinkable outdoor type cable termination kit for XLPE cable - 3X240 Sq.mm(11 KV)
08 00 650-River sand
08 01 035-Cable covering tiles 250x250x40 mm
08 02 460-Route & joint indicating stone with M. s Anchor rod
07 68 058-GI Pipe-150 mm diaA Cl
03 04 224-11kV G.O.S 400A Double break
03 02 122-HG Fuse 11KV Class Solid Core Type
03 04 212-11kV 200Amps Single Break GOS
Double Pole Structure Complete including 5 KG 8-SWG G.I.wire for Structure Grounding - For 9 Mtr RCC Poles 145 kg WL (with pole)
Earthing Material Set
02 00 105-RCC Pole-9.0M Long 145 kg WL
Special Cross Arms Set - with EG Stirrups , Braces , Clamps ,Bolts Nuts and Washers Complete
02 83 320-Silcon rubber composite disk insulator/11kV 45 kN Polymeric insulator
11 kV Horizontal Cross Arm with single top support, clamp, Bolt & Nuts with washers for RCC Poles - MS
02 79 131-Three H Frame with Transformer Seating and Seating angle support X arm for 11 mtr Spun Pole for 63/100/250/500kVA (UG Cable) - MS
02 00 120-Pre - Stressed Tubular Spun Pole 11 Mtr Long - 500Kg WL
02 84 108-Rabbit ACSR Conductor
4 Pin Cross Arm with pole clamp, bolt & nuts & washers for RCC Pole - MS
02 83 003-1.1kV Ceramic Pin Insulator (Shell only)
02 83 053-1.1kV GI Pin FOR 1.1kV Cermaic shell Insulator
03 01 152-L.T. Wiring kit For 63 kVA DTC double circuit
03 01 107-LT Protection kit
03 03 205-Lightning Arresters 9kV 5kA Polymeric type
System Improvement works for 11 kV , 3 Core XLPE UG Cable (Flat armoured) 3X240 Sq.mm - Ordinary Soil
Making of Cable Terminations - Ordinary Soil
Covering cable with Tiles - Ordinary Soil
Fixing of Route Joint indicating Slabs. - Ordinary Soil
Laying the GI Pipe 80mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete. - Ordinary Soi...
Laying of UG Cables by trenchless technology by adopting horizontal boring& Drawing of cable including preparation at site With HDPE Pipe - 6 bore size
Earth work excavation for cable trench of 0.5 to 0.75 mtr. Width and Depth upto 1 mtr. including trial pits, depositing on bank upto a lead of 50 mtrs, Supplying and Displaying necessary Danger Boards...
Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead ...
Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm.
System Improvement works for 11kV GOS 400 A Double Break - Ordinary Soil
System Improvement works for 11 kV Solid Core HG Fuse Unit - Ordinary Soil
System Improvement works for 11kV GOS 200 A Single Break - Ordinary Soil
Dismantling work-11kV 200Amps Single Break GOS
Double Pole Structure complete including 5 Kg, 8SWG, GI Wire for Structure Grounding 9M RCC Poles(System Improvement works) - Ordinary Soil
Digging of pit. For providing GI Pipe type Earthing - Ordinary Soil
Erection Of RCC Poles9M 145kg WL / 9M 150kg WL square section(System Improvement works) - Ordinary Soil
Labour for Special cross arm with cross arm for EG Stirrups, braces, clamps, bolts nuts and washers complete - Ordinary Soil
System Improvement works for 11 kv Horizontal cross arm with HT single top support ,clamp ,bolts ,nuts and washers case of RCC/PSC/PCC poles (set ) - Ordinary Soil
Erection of Single Pole Transformer Structure Kit with Three H Frames without tranformer seating and seating Angle support cross arm for 63/100/250/500kVA (UG Cable) - Ordinary Soil
System Improvement works for Pre-Stressed Tubular Spun Pole 11M Long - Ordinary Soil
System Improvement works for Conductor Rabbit ACSR - Ordinary Soil
System Improvement works for 4-pin cross arm with poles clamp ,bolts,nuts and washers without braces RCC/PSC/PCC poles (set ) - Ordinary Soil
Wiring of Two circuits of LT Wiring Kit for for25/63/100 KVA DTC to the existing LT protection Kit/ Distribution Box via metering box. - Ordinary Soil
Digging of pit. For providing GI Pipe type Earthing - Ordinary Soil
Fixing of LT Protection Kit - Ordinary Soil
Releasing and Refixing-Distribution Transformer-63kVA Almunium Wdg. - Ordinary Soil
Dismantling work-RCC Pole-9.0M Long 145 kg WL
Dismantling work-Single Pole Mounted Transformer kit for 25/63 kVA on 9 mtr RCC Poles (square section)
Dismantling work-LT Protection kit
Releasing and Refixing-LT Electronic Tri - Vector Meter 5A, Class-0.5 accuracy - Ordinary Soil
System Improvement works for Lightning Arresters 9 kV , 5kA Polymeric Type - Ordinary Soil
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
365 Bid_Docs.zip
Tender Document • 6.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .