| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹33.5 L+₹4.6 L (16.0%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹36.9 L+₹8.0 L (27.8%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹42.3 L+₹13.4 L (46.5%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹44.3 L+₹15.5 L (53.6%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Mar 2021, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
OUTSOURCING OF SERVICES FOR HT INSTALLATIONS AND REPAIRS MAINTENANCE OF HT/LT EXTERNAL ELECTRICAL EQUIPMENTS AND ALLIED WORKS AT ATC DEVATALAGUTTA AND ADJOINING AREA AT KANCHANBAGH, HYDERABAD
2021_MES_425067_1
GE I KBAGH TOKEN 83 OF 2020 2021
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
17 May 2021
24 Feb 2021
1 Apr 2021
24 Feb 2021
30 Mar 2021
10 Mar 2021
24 Feb 2021 - 3 Mar 2021
Amount
Outsourcing of services for Operations for 11 KV /0.433 V MRS at ATC DMRL having of 4 Pole structure - 4 Nos, transformers - 9 Nos, 2 pole structures - 5 Nos, LT panel board - 11 Nos, HT panel - 02 Nos and connected HT/LT lines/ cables, takeover point of 11 KV OH line near Mallapur, HT 11 KV VCBs with connected two feeders of HT cables from RCI MRS to ATC Devatalagutta, patrolling the connected lines once in two days, attending & rectification of fuse/Jumper repairs off calls of HT/LT for restoration of electric supply on top priority during breakdown in ATC complex including DSC Md Accn and connected feeder from RCI and Maintenance of HT/LT cables, control cables, LT panel boards for sub station lighting, earting pits of all the equipments (including regular watering) & plants, carrying out regular testing of the equipments and maintaining of the earth of the earth testing register/insulationtesting register/Oil testing registes etc, Log Book with Duty Roaster/ attendance register records of the electric supply with all parameters as described at the sub station and daily maintenance of the complete surrounding area of the Main Sub Station. As when Supply fails/ restore from RCI or breakdown is informed to the Main Sub Station incharge within 05 Minutes of breakdown, complete all as specified and directred by the Engr-in-Charge. Note :- The job shall be maintained by employing one Semi-skilled (electrician) each shift for 3 shifts on all days including Sundays and holidays as given below :(a) First shift 0600 hrs to 1400 hrs (b) Second shift 1400 hrs to 2200 hrs (c) Third shift 2200 hrs to 0600 hrs and one unskilled (helper) in two shift 0600 hrs to 1400 hrs (b) Second shift 1400 hrs to 2200 hrs all as directed by engr in charge
Outsourcing of services for pump house, DG Set 125 KVA at Devatalagutta, pumping to bldg servicing tanks/over head tank, and operation of standby DG set for pump house, maintaining record of all installations, and running of 06 borewells and proper water supply distribution to All post and underground sump in ATC area, Fire Fighting Installation, bore wells at DSC Md Accn including proper distribution of water supply to complete area including operation of valves, pumps & operating of Reverse Osmosis Plant system 200 LPH for drinking water complete including operation of valves etc complete by employing 01 PHO Semi-skiied in each shift for three shifts (1st shift 0600Hrs to 1400 Hrs, 2nd Shift 1400 Hrs to 2200 Hrs) and one helper on general Shift (0900 Hrs 1700 Hrs) on all days including Sundays and holidays all as directed. Note :- Carrying out regular checks and services to the plants/equipments for up keep of pump house and ensure serviceability of all the equipments including undertaking routine checks like replacement of gland packing in all pumps valves, checking of electrcial control panel, repalcement of gland rope to pumps, gaskets, "O" rings, nuts, bolts and washers any type any size including thorough cleaning of eqpt/machinery.
Note: (i) In case of requirement, tradesmen provided for one area may be utilized in other areas at the discretion of the department without any extra cost to department as directed by Engineer-in-Charge. (ii) Rate quoted is deemed to be included for leave reserve/Off of the staff employed. (iii) The rate quoted shall be deemed to include the cost of uniform, Shoes, Helmet, Belt and insulation gloves for tradesmen employed. (iv) The necessary Tools & Plants (i.e megger, earth tester,Ledder, Electrician tools, Insulation tap LT/HT as required shall be provided by the contractor. (v) Minimum wages to the employees to be paid monthly. (vi) Each employee should be facilitated with adhoc bonus privilage as applicable in accordance with Govt Of India and the same to be deemed to be incuded in the quoted rate.Documentry proof of duly signed by contractor/ contractor's rep and individual to be forwaded. (vii) Departmental equipments of each building /installations like transformers, HT/LT panel boards, RMU, 6/4/2/1-pole structures equipment, Electric panels and other misc E/M items its accessories copper brass materials etc., shall be under safe custody. In case of theft any item recovery shall be made from the contractor as per direction of Engr-in-Charge. (viii) In case of absence operator, double the rate quoted to be recovered.
(ix) During operation of installations/equipments/tree trimming respective electrical power lines/Electrical panels should be isolated properly, necessary safety measurments(like helmet,belt, insulation glouves etc..),necessary safety precautions / safety devices to be adopted and the quoted rate is deemed to be included for same & in case any eventuality to tradesmen/Operators the contractor is fully responsible. (x) The contractor will adhere to pay monthly payment cycle to the employees irrespective of RAR/Funds availability with department and failing which will be laible to pay. (xi) Temperary laying of LTUG/HTUG cable of any size and any lenth for restoration of supply during break down / other requirement deemed to be included in the above quoted rate. (xii) Uniform,safety shoes shall be provided by the contractor. (xiii) Rate quoted shall be deemed to include for restoration of jumpers, HT fuses using existing resourses during short circuits due to wind/rain, to restore the supply for incoming and out going feeders. Note for all supply only items as mentioned here-in-after: The labour for fixing of the relevant supply only items of the Schedule deemed to be fixed by above manning labour, no extra cost will be paid separately for fixing & taking down old unserviceable items, However for S&F/M&L items the contractor has provide additional manpower/tradesmen for the execution of S&F/M&L items..
Note: 1. Contractor shall quote cumulative of basic rate,VDA , employers contribution towards EPF liability, contribution towards ESIC, contribution towards bonus, over head and profit as applicable as per instruction in vogue including all Taxes, Cess, Levies as applicable including GST. 2. Monthly wages shall be paid by the contractor to the workers/labour only online. Proof of statutory deductions in favour of workers/labour shall be submitted by the contractor to the GE. The contractor will be required to submit copy of valid labour licence from the labour Commissioner within 15 days of commencement of the work. If the contractor fails to submit the same within this stipulated period the contact shall be liable to be cancelled and the performance Secuirty of the firm shall be forfeited accordingly. Reference is also invited to this HQ letter No.A/37696/Gen/Pol/E2W(PPC) dated 27 July 2017 as amended vide letter of even No. dated 09 May 2018.
Inspection of defective cable to locate the fault using cable fault Locator machine complete all as directed.
Servicing to existing 11000 Volts outdoor type GOD 200/400 Amp duly applying petrolium jelly and oiling of parts after cleaning the contact from the rust and deposited carbon including tightning of all the loose connections making good for operation complete all as specified and as directed.
Opening the HT Cable termination Box at both side and after taking shutdown and disconnected the HT cable connections from both ends of any size , Meggering of cable for establised the fault return back and testing commissioning including dressing the ends termination with bolt/washers abd cleaning with CTC complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures, stay rods, laying of underground cable/undergorund pipes etc complete all as specified and as directed
Returning, filling in soils including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick complete all as specified and as directed
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed
Supply and spreading of dry river sand in trenches/ transformer yard/ two pole structure yard for cable protection complete all as specified and as directed Note:- Punned thickness only shall be measured for payment purpose.
M&L for laying common burnt bricks, sub class 'B', of size 230 x 115 x 75 mm in trenches for cable protection complete all as specified and as directed
Material and Labour for cutting existing BT road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and directed
Dismantling the defective jumper, supply and connect new jumper with ACSR conductor with proper binding to HT over head line conductor including binding wire, bolts, nuts, washers and suitable aluminium lugs complete for HT over head line, structures complete all as specified and as directed
M&L for insulation of HT 11 KV 3 Core 240Sqmm connected cable bus size for insulating of Bus bar in Koisk feeder at different location from ATC to RCI MRS with disconnection of cable all connection and reconnection after completion of insulation and Filling of compound at cable entry & out complete all as specified and as directed Note: Three sleeves in one Job
Cutting and trimming trees branches any girth and any size touching to overhead lines and clearing the distance 1.5 mtr length booth side of OH line with in a gap of span 30 mtrs each disposing the same for clearing the site complete all as specified and as directed
Restringing of LT over head ACSR conductor from pin,disc,shackle insulators with suitable binding wire to insulators and connecting in position complete all as specified and as directed
Supply stringing and fixing in position of High Tension/Low Tension overhead line on existing pole with continuous aluminum conductor steel reinforced (ACSR) of any size including taking down unserviceable ACSR conductor complete all as specified and as directed
M&L in repairs for HT 11 KV, Air Break Switch, Gang operated, Triple pole, mechanically operated, mounted on insulator and steel frame, with oprating mechanism worked from ground level suitable for 11KV supply and current rating upto 400Amps.
S&F in repairs 11 KV Grade, Lightning arresters expulsion type complete (Set of Three) with all fittings, transmission class,11000Volts discharge capacity 65KA complete all as directed.
M&L for cable end jointing kit for 11000 Volts grade cable heat shinkable indoor type joint complete with jointing materials and accessories suitable for 3 core 120 sqmm to 185 sqmm including taking down unserviceable jointing kit complete all as specified and as directed.
All as per srl Item No. 19 above but 3 core 240 sqmm complete all as specified and as directed
All as per srl Item No.19 above but 3 core 95 sqmm complete all as specified and as directed
M&L for cable end jointing kit for 11000 Volts grade cable heat shinkable outdoor type joint complete with jointing materials and accessories suitable for 3 core 120 sqmm to 185 sqmm including taking down unserviceable jointing kit complete all as specified and as directed
All as per srl Item No.22 above but 3 core 240 sqmm complete all as specified and as directed
All as per srl Item No.22 above but 3 core 95 sqmm complete all as specified and as directed
M&L for Cable jointing kit for Eleven KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm including taking down unserviceable jointing kit complete all as specified and as directed
All as per Item No.25 above but 3 core 120 to 185 Sqmm complete all as specified and as directed
All as per Item No.25 above but 3 core 240 to 400 Sqmm complete all as specified and as directed Make for item No.19 to 27 : Denson/3M/Rhychem
Supply and laying, testing and commissioning of LTUG cable PVC insulated screen PVC bedded galvanisized steel strip wire armourd electric power cable 1100 volts grade with strandard alluminium conductor including taking down out unserviceable burnt out cable complete all as specified and as directed of the following sizes :-
4 core x 10 sqmm
4 core x 16 sqmm Sqmm
3.5 core x 50 Sqmm
Taking down high pressure SV/ MV/ MH lamp fitting of capacity 70/ 150/250/400W after dismantling from any height of pole/ walls/ any location and detecting the fault in the fitting by checking the accessories and wiring and rectifying the fault and refixing the same at its orginal position complete all as sepcified and as directed. Note:- (i) Items like ballast, Lamp, capacitor, ignitor & holder shall be measured separately under relevant items.
Supply and Fixing of ballast copper wounded type of capacity 70 W suitable for HPSV light fitting complete all as specified and as directed
All as per item No.30 above but 150 Watts complete all as specified and as directed.
All as per item No.30 above but 250 Watts complete all as specified and as directed.
Supply and Fixing Ignitor of 70150/250 of street light fitting including taking down old unserviceable complete all as specified and as directed
Supply and Fixing of capacitor suitable for 70150/250 wattage and type of fitting including taking down old unserviceable complete all as specified and as directed.
Supply and Fixing metal halide /sodium/HPSV lamp of 70Watt capacity complete all as specified and as directed.
All as per item No.35 above but 150Watt capacity 240V 50Hz double ended/ thread type complete all as specified and as directed.
All as per item No. 35 above but 250Watt capacity complete all as specified and as directed.
S&F of weather proof cable 2.5 Sqmm aluminium conductor multistranded twin core including taking down old unsv complete all as specified and as directed. Make:- KEI/ RPG/ INDOASIAN/ FINOLEX/ GLOSTER/ HAVELLS
Taking out unserviceable Star/Delta starter of 3 phase, 440 V and replace with new Star/Delta starter suitable for upto 10 HP capacity submersible pumps including all internal connections with copper wire testing and commissioning complete all as specified and as directed Make: L&T/CROMPTON GREAVES/COSMO
Taking out unserviceable DOL starter of 3 phase, 440 V and replace with new DOL starter suitable for 5 to 7.5 HP capacity submersible pumps including all internal connections with copper wire testing and commissioning complete all as specified and as directed. Make: L&T/CROMPTON GREAVES/ COSMO
Taking out & lowering down the submersible pump set of any capacity/HP/stage/make from any depth including disconnecting the water, power supply mains for examination/ repair and lowering down and connecting the same after repairs complete all as specified and as directed. Note:- Equipment like tripod and chain pulling block/eqpt machine etc required for this job shall be deemed to be included in the quoted rate.Repairs shall be measured & paid separately under respective items.
Flushing out sand, mud from existing bore well of size 150mm dia to any depth with air compressor complete all as specified and as directed. Note:- Taking down and lowering of submersible pump set shall be measured and paid under relevants items of schedule.
M&L for repairs to the submersible pump set of 7.5 HP to 10 HP capacity by, Renewal of impeller, bearing, repair to shaft complete all as specified and as directed.
Rewinding of motor of submersible pump set with PVC insulated copper wire of existing gauge and quantity for 7.5HP to 10 HP capacity, including re-assembling, testing and commissioning complete all as specified and as directed.
Taking out unserviceable PVC water proof cable of 2.5 Sqmm, 3 core copper conductor and replacement with new cable of same size suitable for submersible pump set complete all as specified and as directed Make :- KEI/ RPG/ INDOASIAN/ FINOLEX/ GLOSTER/ HAVELLS
S&F in repairs switch piano one way 5 Amps 240 Volts complete all as specified and as directed
S&F in repairs switch socket combination 3 pin 5 Amps complete all as specified and as directed
S&F in repairs switch socket combination 5 pin 15 Amps multipurpose type complete all as specified and as directed. Make:- ANCHOR/LEADER /STANDARD/ KONE/ HAVLEES/ INDOASIAN
S&F ceiling fan regulator electronic stepped type operating on 230V, AC supply including taking down old unserviceable one complete all as specified and as directed.
S&F of electronic choke suitable for 36/40 watts CFL/ FTL fittings including taking down old unserviceable one and after rectification refixing in same position, complete all as specified and as directed
S&F of MCB SP 5-32 Amps capacity including taking down unserviceable one complete all as specified and as directed
S&F of MCB SPN 40 Amps capacity including taking down unserviceable one complete all as specified and as directed
S&F isolator 4 pole 100 Amps 415 Volts including taking down existing unserviceable Isolator complete all as specified and as directed
Taking down unserviceable ceiling fans/Exhaust fans, dismantling, overhauling,and replace the unserviceble spares like Ball bearing/ bushes, Capacitors, down rods including reassembling/ refixing back in the same location, including with cord flexible copper conductor connections after completion of repairs, complete all as specified and as directed. Note : Spare parts will be measured and paid separately as supply only fixing included.
M&L for rewinding of fan motor of any make/sweep of ceiling fan, exhaust fan/ Pedestal fan any dia mm, including removal of existing burn't winding carefully from slots,cleaning the slots with cleaning agents,and rewinding with super enameled copper wire of same guage/type, varnishing complete all as specified and as directed.
Supply only 2.5 mfd capacitor complete all as specified and as directed
Supply only ball bearings suitable for any type of fan/exhaust fan/ pedestal fan and testing complete all as specified and as directed Make: NBF/NBC/TATA
S&F in repairs LED Street light fitting with IP66 type protection, 90W, 50 Hz and housing epoxy powder coated dia casted aluminuim housing with bright anodised reflector and enclosed with heat resistant and toughened glass front visor including constant current driver suitable for 140-270V AC , fixing on pole/Wall/bldg (including adjustment for up or down in pole or wall) side mounitng suitable for 40-60mm OD pipe and provn of 3 core PVC insulated PVC sheathed copper conductor multistranded wire upto fitting complete all as specified and directed. Make:- CG / Phillips/ Jaguar
S&F in repairs LED flood light fitting with IP66 type protection, 100W, 50 Hz and housing epoxy powder coated dia casted aluminuim housing with bright anodised reflector and enclosed with heat resistant and toughened glass front visor including constant current driver suitable for 140-270V AC , fixing on pole/Wall/bldg (including adjustment for up or down in pole or wall) side mounitng suitable for 40-60mm OD pipe and provn of 3 core PVC insulated PVC sheathed copper conductor multistranded wire upto fitting complete all as specified and directed. Make:- CG / Phillips/ Jaguar
S&F MCCB 400 Amps, 35/36 KA, 4 Pole Adjustable type with sheet metal enclosure with cable end box for incoming & outgoing cable including taking taking down old unserviceable MCCB complete all as specified and directed. Make :- Havell's/STANDARD/ C&S/ INDOASIAN
S&F MCCB 250 Amps, 4 pole, 35/36 KA, 415 volts, 50 HZ with encloser including taking taking down old unserviceable MCCB complete all as directed. Make :- Havell's/STANDARD/ C&S/ INDOASIAN
S&F MCCB 200 Amps, 4 pole, 25/35 KA, 415 volts, 50 HZ with encloser including taking taking down old unserviceable MCCB complete all as directed. Make :- Havell's/STANDARD/ C&S/ INDOASIAN
S&F MCCB 125 Amps, 4 pole, 10/16 KA, 415 volts, 50 HZ with encloser including taking taking down old unserviceable MCCB complete all as directed. Make :- Havell's/STANDARD/ C&S/ INDOASIAN
S&F MCCB 100 Amps, 3/4 pole, 10/16 KA, 415 volts, 50 HZ with encloser including taking taking down old unserviceable MCCB complete all as directed. Make :- Havell's/STANDARD/ C&S/ INDOASIAN
S&F MCCB 160 Amps, 4 pole, 25/35 KA, 415 volts, 50 HZ with encloser including taking taking down old unserviceable MCCB complete all as directed. Make :- Havell's/STANDARD/ C&S/ INDOASIAN
S&F MCCB 63 Amps, 3 pole, 10*/16 KA, 415 volts, 50 HZ with encloser including taking taking down old unserviceable MCCB complete all as directed. Make :- Havell's/STANDARD/ C&S/ INDOASIAN
Supply and filling of transformer oil in transformer plinth/pole mounted including testing complete all as directed . Make:- SERVO / POWER OIL
Dehydration including filtration cleaning of transformer oil in transformer and OCBs indoor / outdoor type at different location ATC Devatalagutta area by contrifusion / machine having minimum capacity 100 to 1000 ltrs including testing oil before and after dehydration for each complete all as directed .
Servicing of existing 11 KV Breakers (SF6/ VCB type) by disconnection control wiring connection and Opening of all Mechanical & non mechanical parts including charging mechanism, cleaning and removing dust & old oil/grease and applying petrolium jelly & oil to all moving and non-moving parts and repairs minor parts and check all parts are funtioning including draw out mechanish servicing and oiling including tightening of all the loose connections/ parts , replacement of broken side glass/fibre sheet & reconnecting the same and making good for operation complete all as specified and directed
Material and labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtrs below ground level with the top edge of earth plate at a depth of not less than 1.5 mtrs below normal ground level, connected to and including galvanised iron earth strip of size 32x6 mm with GI medium grade protection pipe of 40 mm dia for earth electrode upto test point or upto 7.5 mtr whichever is less, by means bolts, nuts, check nuts and washers of galvanised iron including necessary excavation earth work in any type of soil, PCC pit (1:3:6) type C1 and RCC cover (1:2:4) type B1 of 40 mm, watering pipe 20 mm dia GI pipe, wire mesh, funnel, lugs, charcoal, salt etc complete all as per electrical plate No. 3 or SSR Part-I including taking out old earthing complete all as specified and directed. Note : GI strip and GI pipe 40 mm dia beyond 7.5 metres per earth will be measured and paid separately.
M&L Galvanized iron strip 32 x 6 mm buried in ground/fixed on wall including excavation and earth work & taking down old strip complete all as directed .
M&L for cleaning/Painting the LT/HT poles of OH lines and six poles/four poles/two poles structure complete with cross arms any height and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of synthetic aluminum paint over a coat of redoxide primer including marking of pole numbers and colour washing of pole coping details as are under :-
Single HT Poles
Two poles with cross Arms
Four Poles with cross Arms
S&F PVC Junction box of size 250x200x100mm,light weight pole mounting including MCB SP 10Amps including necessary busbar MCB mounting arrangement and necessary connector for looping in and looping out cable connection and suitable glands including taking down old UNSV one complete all as directed by Engr-in-charge. Make :- SINTEX/Indo Asian
Supply and fixing in repairs post top insulator post top porcelain insulator vitreous brown with GI clamp, nuts, bolts etc suitable for 11000 Volts grade working pressure complete all as directed.
Renewal of Jumpers 11 KV of any size after removing unserviceable insulation and provided new insulation tape/pipe of required length and colour, lugs, nuts and bolts and connection complete all as specified and directed
S & F in repairs drop out fuse assembly 11KV (set of three) , rated current 100A, complete all as directed
M & L for repair and servicing of existing solar system of capacity 500LPD by carried out necessay descaling of copper tubing in collector panels, repair/ servicing of water circulating pump, repairs to insulation of storage tank including replacement of unserviceable heating elements, copper tubing and allied parts of the system complete all as directed.
Taking down the unserviceable Control Panel board for submersible pump set and S&F new Submersible Pump Controller MU-G10 DOL Starter suitable for submersible pump of capacity 7-5 to 10 HP, in sheet Enclosure type MU-G and replacement of existing old & rusted angle iron frme with new angle iron frame pedestal type made out of 2mm thick MS Sheet with 50 x 50 x 6mm thick angle - 02 nos Legs duly embedded in ground with PCC cubes and other end welded to panel board complete all as directed. Make :- L&T Model : SS95983
Supply and fix analog time switch timer switch 16 A, 2pole 230VAC, complete all as directed Cat J678B1. make Quartzor equivalent
Renwal of LED tube Rod 4 feet length,36/40w including taking down unserviceable one complete all as directed. Make:CG/Wipro/Surya
Dismantling and taking down Geyser of 25/50 litres capacity of any make and pattern from the existing position and removing bolts and nuts, opening and taking out all internal unserviceable parts, leak testing of the inner container, refixing the same in original position after necessary repairs complete all as directed. Note:- Replacement of unserviceable parts will be measured and paid separately under relevant items of this BOQ.
S&F in repairs geyser element of any type and model for 25/50 litres capacity for the 1500 W complete all as directed.
All as per srl item No.81 here-in-before but 2000 Watts Make for item No. 82 & 83 :- REMSON/ SEIKO/ POWER PACK
S&F in repairs thermostat of the geyser, 15 Amps and tempreture of 70°C complete all as directed Make : KOHINOOR/MAHAVIR/PRAYAG(SYMET)
S&F in repairs PVC connection with metal fabricated outer connection for geyser, of best quality 15mm dia, 600mm long with union, brass nuts and washers for hot water pipe for outlet connection complete all as directed. Make : KOHINOOR/ MAHAVIR/ PRAYAG (SYMET)
S&F in repairs PVC connection for geyser, of best quality 15mm dia, 600mm long with union, brass nuts and washers for inlet water pipe complete all as directed. Make : KOHINOOR/ MAHAVIR/ PRAYAG (SYMET)
S&F in repairs indicating lamps with holders, connecting up with existing wire for any make, model and capacity of geyser complete all as directed.
S&F in repiars copper cable of size 3 core 2.5 Sqmm, PVC insulated sheathed, multistranded copper conductor complete all as directed.
S&F LED light fitting 1x20 W, 4ft Extruted aluminium batten suitable foe surface mounting complete
S&F in repairs Pipes galvanized, for Drinking Water “Medium class”, supplied And laid complete including fittings 50 mm (2.0”) dia.
S&F in repairs Pipes galvanized, “Medium class”, supplied And laid complete including fittings 25 mm (1.0”) dia.
S&F in repairs 50 mm size dia screwed down, high pressure Gun-metal. Globe or gate valves,with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S&F 25 mm size dia screwed down, high pressure Gun-metal. Globe or gate valves,with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
M&L in repairs for Rotational moulded polyethylene water storage tanks of capacity 1000 ltrs (Cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
M&L for steel tubular swaged pole, type 410, SP-31 (9.0 meter long) complete with CI base plate and errection of pole including excavation and earth work and PCC (1:3:6) type D2 for foundation base and for foundation and coping with PCC (1:2:4) type B1 and painting with two coats of aluminium painting over a coat of red oxide primer & white wash for PCC coping including taking down old pole complete all as directed. Make: National tubing co.,/India Tubes co.,/ Bharat Poles. Note:- Crane charges for erection shall be deemed to be included in quoted rate.
M&L for steel tubular swaged pole, type 410, SP-55 (11.0 meter long) complete with CI base plate and errection of pole including excavation and earth work and PCC (1:3:6) type D2 for foundation base and for foundation and coping with PCC (1:2:4) type B1 and painting with two coats of aluminium painting over a coat of red oxide primer & white wash for PCC coping including taking down old pole complete all as directed. Make: National tubing co.,/India Tubes co.,/ Bharat Poles. Note:- Crane charges for erection shall be deemed to be included in quoted rate.
Shreshta Associates
vvcenterprises
SHANTI MARKETING AND SERVICES
M/S PAVANI ENTERPRISES
JAYRAM INDUSTRIES INDIA PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .