Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr | L1 | Accepted-AOC Successful bidder |
| 2 | L2₹2.0 Cr+₹1.1 L (0.58%)Rejected-AOC HOUSE NO 1 SURYA PATH BHAGADUTTAPUR KAHILIPARA GUWAHATI P O KAHILIPARA P S DISPUR KAMRUP METRO PIN 781019 | GUWAHATI | KAMRUP METRO | ASSAM | 781019 | ₹2.0 Cr+₹1.1 L (0.58%) | L2 | Rejected-AOC Unsuccessful bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not qualified |
Tender Value
Refer Docs
EMD Value
₹3.7 L
Closing Date
21 Dec 2020, 2:00 pmClosed
SE Guwahati Building Circle-II Chandmari
SE office Guwahati Building Circle-II Chandmari
Construction of Balance area of Ground Floor (with provision of G 4) of Basic Science Building at Govt. Ayurvedic College Hospital, Jalukbari
2020_PWBNH_19568_1
SE/BII/Tech/291_Basic Science_Balance
Open Tender
Civil Works - Building
Item Wise
365 days
Jalikbari, Guwahati
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,600
Assam State Road Board Maintenance (Roads) Fund
₹3.7 L
Yes
SE office Guwahati Building Circle-II Chandmari
22 Jan 2021
11 Dec 2020
22 Dec 2020
11 Dec 2020
21 Dec 2020
11 Dec 2020
15 Dec 2020
Amount
Providing cast in-situ manually driven reinforced cement concrete piles of M20 grade concrete of required bore-diameter, lengths and with reinforcement as per specifications and drawings. Reinforcement to be measured and paid seperately as per item no. 21.4.1 C) UNIFORM PILE d) Pile Dia 400 mm ii) Above 10 M
Supplying, fitting and fixing in position reinforcement bars conforming to relevant IS code for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. A) For TMT bar of Primary Producer (From Primary Producer)
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar
b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc.
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2.00M below the existing ground level. (a) In ordinary soil
(A) Upto a depth of 2.00M below the existing ground level. (c) In soft or laminated rock or medium shale
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantityetc. complete as directed and specified, including forest royality within a distance of 8.00Km. (Forest royality shall be reimbrushed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned). i) Within Guwahati municipality area.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) I) Using mixture machine A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. b) M20 or Prop. 1:1.5:3
a) M15 or Prop. 1:2:4
B) In superstructure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 or Prop. 1:1.5:3
a) M15 or Prop. 1:2:4
Providing formwork of ordinary timber planking so as to give a rough finish including centering, shuttering strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. ii) Using 38mm thick plank.
Sides of tie beams, grade beams etc. at or below ground level. b) Using 25mm thick plank..
Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face b) Using 25mm thick plank..
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. b) Using 25mm thick plank..
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. a) Brick on flat soling
Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub-structure up to plinth level. b) In prop. 1:4
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/ Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall a) In cement mortar 1:4
Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding, providing face stone, through stone and centering including racking of joints, curing and supplying and all carriage of stone as directed including payment of forest royalty and sales tax and carriage. (a) Random Rubble Masonry
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mmx450mm and above
Grading roof for water proofing treatment with (a) Cement concrete 1:2:4 (cement: 2 coarse sand: 4 graded stone agg. 20 mm nominal size)
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (A) CERAMIC i)Normal range (Sizes 300 mm x 300mm and above) (a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
B) On fair side b) In cement mortar 1:4
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (b) 20 mm thick
Providing two coats of Birla white wall care putty (Water resistant white cement based putty for concrete/mortar walls and ceiling both internal & external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean wqater as specified and directed by the department.(Total thickness of two coats is maximum 1.5mm) i) Thickness = 1.5mm
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra over item no 13.4.1 above for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
d) Extra over item no. (b) and (c) above for every subsequent coat of water proofing cement paint of approved brand and manufactured.
Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately). (b) 1.60mm thick sheet (iii) Size 125mm x 60mm (Single rebate)
Providing welding, fitting, fixing, hoisting and fixing of roof trusses of TATA make with purlin, bottom runner etc. fabricated out of a combination of two or all of the following sections: (i) Square Hollow sections (ii) Rectangular Hollow section od specification RHS/SHS Grade YST 310 conforming to relevant I.S. code 4923:1997 and (iii) M.S. black-tubes of Grade YST 210 conforming to relevant I.S. code 1239 as per approved design and drawing including M.S. cleat, base plate, bolts and nuts which ever required, including that required for fixing the ceiling and one coat of red oxide Zinc Chromate primer to all steel surface etc. complete as directed as per specifications. a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) (iii) 0.50 mm thick
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. b) Non decorative type and block board core. (i) 40 mm thick
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished) a) Sliding door bolts i) 300mm x 16mm
b) Tower bolts i) 300mm x 12mm
c) Door handles iii) 150mm
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (b) 3 Track sliding window (iv) 5 mm clear glass
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). a)Side hung and Top hung windows and ventilators (iv) 5 mm clear glass
Providing, fitting and fixing 40mm x 48mm wood reinforced PVC chowkhats fixed to the columns / stiffeners / walls with necessary holdfast / sleeves etc. as specified and directed at all levels.
Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) b) 29mm thick
Providing, fitting and fixing M.S. grill of requiredpattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. I. Plain grill (c). Fixed to Brickwork/P.C.C/R.C.C.
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. a) 100mm thick slab
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (5 KG) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supplying fitting and fixing P.V.C. pipes of 6 kg f/cm2 (Supreme /Prince) and other ISI approved including joining, fitting and fixing with clamps etc as necesary complete at all levels including below G.L as directed and specified a) In Exposed surfaces or in trenches. (ii) 110 mm dia
(iv) 75 mm dia
Providing fitting and fixing Vitreous china wall hang water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) a) Parryware make (i) Pal Walvit Pan (inclusive of seat cover and fittings) (white/coloured) (Cat. No. C844K)
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) a) Parryware make b) Coloured (i) Economy Single Flush (Cat No.C8090/C8055)
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (ii) Continental 600mm (Cat.No. ACN-1111N)
Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (b) Size 600mmx450mm
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. A) Parryware make (i) Recess SP & SG dish (Cat.No. C9935)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Basin (With Pedestal) A) Parryware make (a) White (i) Duke 660 x 495 (Cat. No.C8416/27) (white/coloured)
Providing fitting and fixing vitreous china squatting plate urinal with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. A) Parryware make (ii) Coloured (Cat. No.C0573)
Supplying , fitting and fixing 87.5 degree PVC bend of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc as necesary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. (b) 110 mm
Supplying , fitting and fixing 87.5 degree PVC bend with door of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc as necesary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia
Supplying, fitting and fixing PVC plain single tee of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc as necesary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia
Providing, fitting and fixing C.P. Grating ii) 110 mm dia
Providing fitting and fixing (600x600)mm 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (A) Exposed on walls a) 50 mm dia (Medium) i) Using Tata make
(A) Exposed on walls b) 40 mm dia (Medium) i) Using Tata make
(A) Exposed on walls f) 15 mm dia (Medium) i) Using Tata make
Supplying, fitting and fixing C.P. pillar cock 15 mm dia of approved brand as specified and directed Jaguar make (a) Continental
Supplying , fitting and fixing C.P. bib cock 15 mm dia of approved brand directed and specified. (G.I & C.P pipes will be measured separately) II) Jaquare make (a)Continental /Clarion, (ii) Bibcock long thread
Supplying fitting and fixing chrome plated …. as directed and specified.(G.I. & C.P pipes will be measured and paid separately) .(I) Jaquar a) Continental/ Clarion) ii) 15mm dia (Angular stopcock)
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank o…...as required for inlet and outlet pipes i) 2000 litres capacity. A) Syntax make.
Labour for erecting and placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. i) 2000 litres capacity.
Supplying and fitting gun metal country pit valve (Full way valve) I.S.I. Mark as specified and directed. a) 50 mm dia
b) 40 mm dia
Supplying and fitting ball valve as specified and directed.. b) 20mm dia. (gun metal/Copper)
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete Short point up to 3.00 metre. Length.
Medium point up to 6.00 metre. Length
Long point up to 10.00 metre. Length
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. Short point up to 3.00 metre. Length.
Wiring for 5 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 2 mm thick 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Long point up to 10.00 metre. Length.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 6 module type Metal
8 module type Metal
12 module type Metal
18 module type Metal
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 6 module
8 module
12 module
18 module
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt
Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying and fixing of batten holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.)as required Without Lamp
Supplying and fixing of Call bell ( Buzzer ) including 5/ 6 amp capacity button piano type bell push switch including connection as approved by the Deptt.)as required.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4 way TPN (4+12) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 63A
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make)
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Power Flow 225 mm sweep (ORIENT make)
Supplying with fitting and fixing of Angle iron framing made 50 mmx50 mmx5 mm size angle iron for accommodation of 1.00 Ton to 2.00 Ton Window/split type A.C. Machine
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make) 3.0 KVA Automatic Input 90-280 V Out put 200-240 V
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 3 & 1/2 Core A2XFY 150.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2 - module type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. 120 watt electronic modular step speed control 2 - module type
Supplying with fitting fixing of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying fitting and fixing including necessary connection as approved by the Deptt.)of Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) of following type and capacity as specified and directed by the Department. ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) D.O.L Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make)0.5 TO 10 HP, 0.72 TO 20 A.
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415V 50 Hz 4P MCCB (C&S, Indo Asian, HPL, V-Guard or equivalent make as approved by the Deptt.) 315A
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved by the Deptt.),as specified and directed by the deptt. 25 KA 415V 50 Hz 3P MCCB (Havells, HPL, Indo Asian make) 63A
Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries. Header with top cap 300 mm long pipe of thickness 3 with arrangement to fix on pole top with 3 Nos. of bolts. i Armed of required length size 48.3mm out side dia x 3.25mm thick (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) Stiffener plate from arm of the following types : Single arm bracket 1000mm long for 3m to 10 metre. Poles.
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 A2XWY A2XFY 6.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 8 way SPN double door
ABB, Schneider MG, legrand, Hager make) 12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 4 way TPN (4+12) double door
Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding of the pole shaft. The welding of the pole shaft shall be done by Submerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) Pole Type BOP or equivalent-5030, Height 5m The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO , Base Plate Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections The Octagonal Poles shall be in single piece with single longitudinal welding join. Galvanization:- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening :- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia. (A/ 70, Bottom Dia. (A/ 130, Sheet Thickness 3mm . Base Plate Dimensions (L x B x 200 x 200 x 12, Foundation Bolt , Bolt Size (no. x dia.) 4 x 16 Dia, Pitch Circle Dia. (PC 200, Bolt Length 600, Projected Bolt Length 80, Anchor plate thickness 4 mm , Pole Foundation:-The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation. The foundation shall be done with ( Earth work :- 2.04 cubic Meters.RCC :- 1:1.5 : 3 proportion 0.65 cubic metres, Steel:- 22.43 Kg, Shuttering:- 4.32 square metres. = 22.43 Kg.
Supplying, fitting & fixing of LED non dimmable in the existing batten/ angle holder ….. Etc. as required and directed by the Deptt. Prima Series Bulb 12W
Supplying, fitting & fixing of LED Kubic batten Tubelight fitting 300mm length as required and directed by the Deptt. Jaquar or equivalent make Kubic series Batten tube light 20W
Supplying with installation testing and commissioning of Hi- wall 5 star rating nonducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection as approved by the Deptt. upto 5m between the room unit and out door unit as directed by the Deptt. 1.5 Ton capacity (Volas make)
Supplying with installation testing and commissioning of Hi- wall 5 star rating nonducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection as approved by the Deptt. upto 5m between the room unit and out door unit as directed by the Deptt. 2 Ton capacity (Volas make)
Supplying with installation testing and commissioning of the following indoor Decorative surface mounted 2' x 2' LED Luminaries of model no. SM365C LED 32-6500 PSU OD GR/SM365 LED32-6500 PSU WH ……… etc. as required complete and directed by the Deptt.
Supplying with installation testing and commissioning of pressure die cast powder coated aluminium alloy housing forsted PC diffuser, IP65/IP66 proctaction of the following street light lumineries ………. Etc. as required complete and directed by the Deptt. BRP 409 LED 065W CW HE MR FGSI PSU GR
Sri Mrinal Saikia
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .