Loading…
Loading…
Tender Value
₹43.6 L
EMD Value
₹87,240
Closing Date
15 Jul 2026, 6:00 pm
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
PROVN OF VRF RV AIR CONDITIONING FOR BRIEFING ROOMS AT FIS AT AFS TAMBARAM
2026_MES_774483_1
GE(AF)/TBM/8904/E8
Open Tender
Civil Works
180 days
AIR FORCE STATION TAMBARAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹87,240
24 Jun 2026
24 Jun 2026
17 Jul 2026
24 Jun 2026
15 Jul 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, Supply, installation, testing & commissioning 46 HP outdoor unit with cooling of Variable Refrigerant Flow (VRF) system with multi indoor unit with outdoor units including individual controller for cooling type operation. Outdoor units equipped with highly efficient twin rotary compressors with inverter type compressor, special acryl precoated heat exchanger, low noise condenser fan, auto check function for connection error, having interconnected control wiring between indoor unit, outdoor unit & control panel and refrigerant piping housed in compact housing duly powder coated complete as required for trouble free operation, refrigerant should be R-410a complete all as specified and directed by Engineer-in-Charge. 01 No (Overall 46HP - Capacity & Numbers of the unit may vary) | 1 | Job | 1 | ₹1 |
| 1.02 | * Demand Control Mode or Economy Mode the capacity of the ODUs of the VRF can be set at 25%, 50% & 75% depending on the need.
(ix) The system designed to operate across a wide voltage range from 320 volts to 460 volts resulting in high uptime even in erratic power conditions.
Supply, installation, testing & commissioning indoor cassette unit of the following capacities, 4 way equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outdoor cabinet, drain pan and drain pump, cordless remote, cabling, vibration isolation, earthing, necessary supports etc as per specifications complete all as specified and directed by Engineer-in-Charge.
2.3 TR Cassette Unit - 02 Nos
Note for Indoor units
(a) Multi Level Filtration: Aesthetically superior with stylish design, very low noise, quiet operation, wide angle air flow to ensure even air distribution throughout the condition space.
(b) Multi Speed fan: Various level of fan speed control are mus available for users comport and convenience.
(c) Auto-Restart: Automatic re-start after power cut with all previous set parameters are restored.
(d) Multimode functions: Various mode can be selected depending on the usage pattern and the comfort levels required. AUTO, COOL, DRY, SLEEP.
(e) Flexible air flow patterns: Advanced louvers where swing can be adjusted to meet the needs air flow ventilation and direction required.
(f) Cordless Remote Controller: Cordless remote controller having large LCD screen for better clarity, real time clock display, room temperature indication, displays of various mode-cool, fan, dry. Fan speed adjustable, inside room temperature adjustable from 16 degree to 30 degree centigrade.-10 Nos
4.0 TR Cassette Unit - 08 Nos | - | - | - | - |
| 1.03 | Supply and Installation of Refnet joints (Refrigerant branch kit) for taking branches between various indoors as per VRF scheme drawings. The refnet joint set consists of both liquid and gas line branch kits complete all as specified and directed by Engineer-in-Charge.
Indoor - 28 Nos
Outdoor - 02 Nos | - | - | - | - |
| 1.04 | VRF Central Controller - Supply, Installation, testing and commissioning of BMS compatible Network Interface and Central Remote Controller for monitoring and Controlling the VRF equipments in third party BMS as required basis. | - | - | - | - |
| 1.05 | VRF LOW SIDE WORKS
Installation , Testing, Commissioning and Handing over the VRF outdoor units -46.0 HP TOP DISCHARGE VRF ODU - 01 No
Installation , Testing, Commissioning and Handing over of the following VRF Indoor Units : Cassette Unit.- 10 Nos | - | - | - | - |
| 1.06 | REFRIGERANT PIPING : Supply, Installation and Testing of Refrigerant piping, fittings and Y Branch with suitable thick tubular nitrile rubber insulation finished with laminated glass cloth.Suction line thickness - 19 mm and Liquid Line Thickness - 13 mm. All the tools and tackles required to install the refrigerant piping will have to be arranged by the vendor only without dependency on the client.Complete piping workmanship to be carried out as per recommended practice with the pipe sizes 1/4" to 1 5/8" of length -180RM ( Aprox) | - | - | - | - |
| 1.07 | Nitrogen Pressure Testing at site complete all as specified and directed by Engineer-in-Charge. | - | - | - | - |
| 1.08 | Supply and First Charging of R-410 additional refrigerant gas complete all as specified and directed by Engineer-in-Charge. | - | - | - | - |
| 1.09 | Supply and installation of communication cable carried out with 2 core x 1.5 sqmm shielded cable including PVC conduit 225RM (Approx) complete all as specified and directed by Engineer-in-Charge. | - | - | - | - |
| 1.1 | VRF pipe protection finish for the exposed pipes (Suction & Liquid) : supply and application of one coat of Weatherprotekt coating, fixing 10 mil woven glass cloth, again one coat of Weatherprotekt coating and when finally dry complete with final coat of Weatherprotekt Coating complete all as specified and directed by Engineer-in-Charge. - 180RM (Approx). | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tender.pdf
Tender Documents • 0.65 MB
PS.pdf
Additional Documents • 0.40 MB
BOQ_867247.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid