Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Being reasonable and Lowest L1 |
| 2 | L2₹1.4 Cr+₹9.1 L (7.02%)Rejected-Finance | ₹1.4 Cr+₹9.1 L (7.02%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹1.7 Cr+₹44.1 L (33.9%)Rejected-Finance | ₹1.7 Cr+₹44.1 L (33.9%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹1.8 Cr+₹51.4 L (39.5%)Rejected-Finance | ₹1.8 Cr+₹51.4 L (39.5%) | L4 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
19 Oct 2020, 6:00 pmClosed
Col SS Bose
HQ CWE (AF) Chakeri Kanpur
IMPROVEMENT TO INFRASTRUCTURE AT VIPER OH LINE AT 4 BRD AT AFS KANPUR
2020_MES_373441_1
82160/E8
Open Tender
Civil Works
Item Rate
272 days
GE (AF) E/M Chakeri
Class B cat a (i) and b (i)
8 documents required · 8 mandatory
₹1,000
Yes
GE (AF) E/M Chakeri
₹2.2 L
18 Dec 2020
31 Aug 2020
26 Oct 2020
31 Aug 2020
19 Oct 2020
5 Oct 2020
Amount
B/R WORK Dismentaling of cement concrete (unreinforced) ground floor and paving not exceeding 15 cm thickness below or above GL complete
Demolition of brick work, build in cement mortar or cement lime mortar incl all queons, arches, pillars etc complete
Grubbing of tree trunk of any girth exc 30cm and not exc 100cm incl cutting of trunk portion protuding over ground, diging out roots, filling holes and levelling of ground stacking of unserviceable materials and removing unserviceable materials to the distance exc 50M from the starting point as directed by Engr-in-charge.
Taking down cement plaster or cement lime plaster from bk wk incl racking out joints hacking for key and scrubbing down with water etc complete
M&L brick wk with Fly ash bricks using old size brick, straight or curved on plan exc 6m mean radious built in CM 1:6 complete
M&L rendering 15mm thick in CM 1:6 on fair faces of brick work/ concrete surfaces and finished even and smooth without using extra cement complete
Demolition of stone sett paving of any description or any thinkness, laid and bedded and pointed in any mortar as in floors, aprons etc
M & L plain cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate)as in sub base, mass concrete complete all as specified and directed.
M & L acid/chemical resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors in CM (1:6) complete all as specified.
M&L brick work with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls in CM (1:4) all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge or thickness at any position or similar pattern of roof covering complete all as specified and directed.
S&F for coloured galvalume profile sheet in roofing shall be with feed material manufactured from 0.50mm (minimum) base metal thickness (BMT), minimum 550 Mpa yield strength and shall confirm to physical specifications of ASTM-792 or equivalent, colour coated galvalume sheet shall have maximun pitch of 250 mm C/C and minimum 28 mm crest depth in length as per site requirment. The steel sheet shall be coated with hot dip metallic Aluminium Zinc alloy (55% Alluminium , 43.5% zink , 1.5% silicon) coatig AZ 150 as 150 gm/Sqm total on both sides. The contractor shall submit manufacturer test certificates for the chemical and mechnical properties, confirming genuinity of material including base metal thickness paint thickness and AZ 150 coating thickness must be submitted for approval to GE prior to the installation / fixing. The manufacturer of sheet should submit related documents for expected product services performances of pre painted metal sheet as per relevant ASTM/ IS. Manufacturer's recommended installatiosns methodology shall be adopted for installsiton of roofing including profiled sheet, capping , trims , flashings , gutter and all types of accessories considered for roofing , fastener shall be used for fixing roofing system as per manufacturer's recommendations. The painting shall be coloured backed enamal super durable polyester with silicon coating of film thickness of minimum 25 micron ( including primer) on top and minimum 10 micron ( including primer) on interior face. The paint shall be of shade as approved by GE and fixed with self drilling screws all as specifeid and directed. Note - Total thickness of sheet with BMT , AZ 150 coating and panting shall be minimum 0.575 mm thick. If 0.575 mm thickness sheet is not available then next higher thickness of sheet shall be applicable without any price adjustment.
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F fibre glass reinforced translucent corrugated sheeting 2 mm thick with two corrugation side lap fixed with coach screw and washer or self tapping screw in roof, wall etc complete all as specified and directed.
S&F 0.80mm thick plain Galvanised steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and directed.
All as per item No 12 &13 here-in-before but fixing only except sheeting (any thickness) complete.
All as per item No 14 above but fixing only except sheeting fibre glass reinforced translucent corrugated sheet.
All as per item No 15 above but fixing only plain galvanised steel sheet.
Taking down/removing of existing water proofing treatment on roof surfaces and wall surfaces complete, including screed bed, racking out joints, hacking for key scrubbing down with water etc., and removing rubbish out of MD land all as specified and as directed.
M & L for spreading / brushing neat cement slurry @ 3.00 Kg/ Sqm on old concrete surface after preparation of surface complete all as specified and directed.
M & L PCC type B0 (1:2:4) (using 12.5 mm graded stone aggregate) thickness as required at site) for padding concrete as on roof mixed with liquid water proofing chemical @ 200m/per bag of cement (Make- Dr fixit or equivalent) etc complete all as specified and directed. (Note:- Liquid water proofing compound shall be measured and paid seperately)
M & L screed bed 15 mm thick (average) plaster on concrete surfaces in CM (1:4) on roof, mixed with liquid water proofing chemical and finishing the surface even and smooth without using extra cement complete all as specified and directed. (Note:-Liquid Water proofing compound shall be measured and paid seperately).
M & L reinforced elastromeric liquid water proofing compound membrane with resilient acrylic polymers having sun reflectivity Index (SRI) of 105 (Make -Asian paints Ltd or equivalent as approved by GE) on top of roof surface in three coats @ 10.76 ltr /10 Sqm. One coat of self priming of elastomeric water proofing liquid (dilution with water in the ratio of 3 :1 i.e. 3 part of water proofing liquid and one part of water) and two coats of undiluted elastomeric water proofing liquid. The dry film thickness of complete allocation/ system should not be less than 500 micron. The treatment shall be carried out through authorised representative of manufacturer only complete all as specified and directed. (Note: Contractor will submit manufacturers 10 (Ten) years gurantee for water proofing treatment through approved manufacturer in stamp paper and a sum of Rs 50,000/- will be ratained from final bill against roof treatment gurantee for 10 (Ten) years).
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L PCC (1:2:4) type B-1 using 20 mm graded stone aggregate in copings / benchings, string courses and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Taking down eaves, gutters and rain water pipes including all fittings any size and pattern.
S&F PVC SWR 150 mm bore single socketed pipes in any length with rubber ring joints fixed to wall complete all as directed.
S&F PVC SWR bend/shoe of any radius for 150 mm dia complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection/path/ hardstanding surface finished fair & even without using extra cement including filling of sealing compund grade 'A' in joints laid in panels complete.
Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed.
S & F mild steel work in support for rain water pipe, hooks, heavy pintle hinges, large hasp hinges, stops, wall tie etc. and similar work confirming to Fe- 290 Grade E-165 complete all as sepcified and directed.
S&F Mild steel wind ties or similar wok for roof including securing bolts, posts including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar work conforming to Fe 290 Gde E-165 complete all as sepcified and directed.
Complete removal of existing treatment on walls after scrapping out with scraper complete all as sepcified and directed.
M & L preparation of new/old surfaces of walls and applying two coat of Oil Bound Distemper over a coat of primer over 2 mm thick wall care putty, of JK Birla complte all as specified and directed.
M & L for preparation of old painted steel and iron surfaces including trusses, purlin, rafters, posts etc of any description over 10cm girth or width not otherwise described and applying two coat of synthetic enamel paint complete all as specified and directed.
All as per item No 35 above but applying one coat of Aluminum paint complete all as sepcified and directed
M & L preparation of new undecorated surfaces of walls and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as sepcified and directed.
M & L precast cement concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as sepcified and directed.
M&L Mild steel TMT 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as sepcified and directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface complete all as sepcified and directed.
M&L MS framed work such as in door or gates or other coverings and simillars works of angle or other section conforming to FE- 410W (Gde-E-250) quality A complete all as specified and directed.
M & L expanded metal weight not less than 4 Kg/Sqm , cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0..9mm dia or fixing with galvanised steel staples supplied and fixed to wood or steel members complete all as specified & directed.
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as sepcified and directed
SPECIAL B/R ITEMS M&L aluminium two track sliding window with frame section 63.50 x 38.10 x 2.00 mm and 1.2mm thick track bottom 61.60x31.75x23.20mm (two track), track top/side 61.60x31.75x23.20mm including shutter frame side 39.40x17.70x10.70mm, shutter top/ pottom 39.40x17.70x10.70mm, shutter interlocking 39.40x17.70x10.50mm with 5.5 mm thick tinted glass, glazing clips, rubber beading alongwith roller, locking plate, handle complete all as specified and directed.
S&F aluminium grills size exc. 4mm x 4mm and aperture n.exc. 80mm including. fixing with aluminium Y channel, 1.20mm thick with steel screw complete all as specified and as directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L aluminium anodised doors shutter made out of anodised aluminium extruded section with door frame section 101.60 x 44.45x2.00 mm size and door shutter (double leaf) frame section top rail section 83.50 x 44.45x2.00 mm, middle rail section 123.x44.45x2.00 mm, bottom rail section 101.60 x44.45x2.0 mm, side rail/style section 83.50x44.45x1.50 mm with 5.50 mm thick tinted glass on top half portion and 9mm thick prelaminated particle board exterior grade on bottom half portion incl rubber gasket, aluminium beading, glazing clips, aluminium fancy handle, tower bolt 150mm long, heavy duty double action floor springs with foundation box, 6 lever mortize lock with duplicate keys and all other reqd fittings as per standard Engineering practice complete all as specified and as directed by Engr-in-Charge.
E/M WORK (INTERNAL ELECTRIFICATION) M & L concealed point wiring on wall and surface wiring on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multistranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including ISI marked PVC conduit medium grade of size not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly covered with bakelite laminated sheet 3mm thick ISI marked for mounting of switches / sockets, fan regulators with brass screw and cup washers including PVC-FRLS insulated and unsheathed copper multistrand conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting and making good with CM (1:3) and to match/ finish new surfaces either by using same colour distemper over putty or white wash / colour wash required complete all as specified and directed for the following:- (a) For one light, fan, call bell point controlled by one switch complete all as sepcified and directed.
All as per itm No 49 above but 5Amp independent socket point controlled by one switch complete all as sepcified and directed.
All as per itm No 49 above but one socket point controlled by one switch on same board complete all as sepcified and directed.
All as per itm No 49 above but power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as sepcified and directed.
M & L, in replacement switch flush type single pole one way 5 Amps, 240 volts, white finish ISI marked complete all as specified and directed.
M & L, in replacement switch flush type 15 Amps, 240 Volts single pole white finish complete ISI marked complete all as sepcified and directed.
M&L, in replacement socket outlet 5 pin, 5 Amps flush type white finish complete conforming/ ISI marked complete all as sepcified and directed.
S&F, in replacement, socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete conforming/ ISI Marked complete all as sepcified and directed.
S&F, in replacement, ceiling rose, surface backlite, 65 x 20 mm three terminalconforming/ ISI Marked complete all as sepcified and directed.
M & L for flameproof concealed point wiring on wall and surface wiring on ceiling / roof with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled ERW rigid steel conduit (metallic) not less than 19 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for one light, fan point controlled by one switch Note : Junction boxes shall be measured separately
S&F flame proof weather proof threaded type junction box LM 6 aluminium alloy 2 way complete all as sepcified and directed.
S&F flame proof weather proof metallic hose conduit 3/4 " dia 300mm longcomplete all as sepcified and directed.
All as per item No 60 here-in-before but 500mm long complete all as sepcified and directed.
S&F Flame proof weather proof switch with cable termination in LM 6 aluminium alloy housing 16 Amp, 240 volts complete all as directed.
S&F metallic body Heavy duty exhaust fans AC single phase 230/ 240 V of size 450 mm sweep, 900 RPM complete with louvers & shutters complete all as specified and directed. (Make- Havells Model No.Turbo Force HS or equivalent in other makes given in Appendix 'B' duly approved by GE.)
S & F in replacement Die cast aluminium alloy LM-6 Flame proof weather proof flood light fitting LED 120 watt, powder coated epoxy based light grey shade 631 as per IS : 5, 'O' ring endless Neoprene Rubber Gasket, heat resistant type clear toughened glass with two numbses cable entriy complete all as sepcified and directed. ( Make Sudhir Cat Part No SAI/WG/3007 or equivalent in other make given in Appedix 'B' as approved by GE )
M&L for high bay light wiring on celling /roof/trusses with necessary fixing arrangment for 3 core PVC insuleted sheathed armoured solid copper conductor of size 2.5 sqmm 1100 volt grade and PVC condoctor 3 pole to be provided for each high bay fittings fixing arrangment with mounded groove for cable size in MS strip not less than 20x2.5 mm suitable nut bolt and washer duly painted with aluminium paint over the red oxide primer by maintaning destance not more than one meter for this light point controled by one MCB DB. complete all as specified and directed. (Note:- (i) MCB DB shall be mounted on column (ii) PVC connector enclosed box connecting type for each fitting point/ point to be fixed near the fitting suitable fixing arrangment and cast sall be inclusive in rate quoted by the contrctor (iii) MS flat shall be used it the cable are not more than 30 cm for mounting arrangment (iv) Five light point will be controlled by independent DB 2 way . (v) MCB SPN DB 2 way and SPN shall be measured and paid separately.)
M&L Sheet metal enclosure for MCB DB 2 way 240V complete in concealed/surface position complete all as sepcified and directed.
S&F in replacement sheet metal enclosure TPNL MCCB DB 12 way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 for DB when MCCB 160 Amps (as incomer) and MCB SP (as outgoing) to be used, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as sepcified and directed.
S&F, in replacement, double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
S&F in replacement testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as sepcified and directed.
All as pr item No 69 above but SP 40-63 Amps complete all as sepcified and directed.
All as pr item No 69 above but SPN 40-63 Amps complete all as sepcified and directed.
All as pr item No 69 above but TP 40-63 A 415V complete all as sepcified and directed.
All as pr item No 69 above but TPN 40-63 Amps complete all as sepcified and directed.
M & L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in suitable PVC conduit with 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as sepcified and directed. Note : (a) PVC Conduit and cutting cheaseling and making good will be measured and paid separately. (b) Two run single cosre 6 sqmm cable & one run 6 Sqmm earth wire shall be measured as one RM unit length).
M & L sub main wiring with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in suitable PVC conduit with two single core 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as sepcified and directed. (Note : (a) PVC Conduit and cutting cheaseling and making good will be measured and paid separately). (b) Four single core 6sqmm cable & two run 6Sqmm earth wire shall be measured as one RM Unit length)
M & L sub main wiring with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 10 sqmm drawn in suitable PVC conduit with two single core 10 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as sepcified and directed. (Note : (a) PVC Conduit and cutting cheaseling and making good will be measured and paid separately). (b) Four single run 10sqmm cable & two run 10 sqmm earth wire shall be measured as on RM unit length).
S&F rigid non metallic medium white / ivory PVC conduit medium grade ISI marked of size not less than 20 mm dia concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc all as directed by Engineer-in-Charge.
All as per item No 77 here-in-before but 25 mm dia PVC conduit medium grade ISI marked complete all as sepcified and directed.
Cutting chases in brick walls, pinning in at the depth of 30 mm, making good to facings where required and pointing in cement mortar 1:3 cutting chases for concealed conduit wiring,submain wiring etc and making good and palstering the surface with cement or plaster of peris and matching with same colour scheme, cutting exceeding 10cm but not exceeding 30cm girth complete all as sepcified and directed.
M & L in replacement Extruded aluminium suspended diffused 4 feet light fitting 38 watt high efficiency suitable for Surface, wall and conduit mounting for energy saver LED light fitting, 230 Volts complete accessories, prewired including required fixing arrangements on false ceiling and electrical connection three core copper cable from ceiling rose to led light fitting complete all as sepcified and directed. (Make : PHILIPS SP680x1 LED39S 6500 PSU WH L120 S1 or equivalent in other make as approved by GE from Appenix 'B').
M & L in replacement for energy saver LED light fitting 40 watt, 230 Volts, single tube mounting including LED Tube/ LED blocks 40 Watt ,Lumen OUTPUT NOT LESS THEN 100 LM /WATT with 50000 burning Hours, PF = 0.95 complete with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection three core copper cable from ceiling rose to led light fitting all as directed including removing of UNSV tube light fitting complete all as specified and directed. (Make: PHILIPS BN100C LED 40S-6500 PSU L120GR or equivalent in other make as approved by GE from Appenix 'B').
M & L in replacement complete for recess mounting LED Panel 600x600 mm fittings made of CRCA powder coated finish LED used shall be SMD type and fixture should have minimum efficiency at system level (Not chip level) 100lm/watt, life of fixture 50000 burning hours @ L70% Lumen maintenance CCT UP TO 6500,CRI MORE THEN 80,pf 0.95 and an operating voltage 140 Volt to 270 volt internal surge protection 2.5 KV AS IS 10322 and IEC 60598 system wattage 31 - 36 watt complete electronic drivers with all internal electric connections complete all as specified. (Make :Philips Cat No. RC 380 B LED 36S -6500 G4 L60 W60 PSU OD or equivalent or equivalent in other make as approved by GE from Appenix 'B').
Supply, installation of perforated GI cable tray 2mm thick, 300 mm wide and 100mm height inclduing laying of eixsting LT cable of any size and any capacity with fixing accessories complete all as directed by Engr-in-Charge.
Supply, installation of perforated GI cable tray 2mm thick, 150 mm wide and 100mm height inclduing laying of eixsting LT cable of any size and any capacity with fixing accessories complete all as directed by Engr-in-Charge.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
Taking down main switch/DB/AC box of any capacity including fixing accessories complete all as spcecified and directed.
Taking down serviceable LT cable from existing position of any size and relaying the same on cable tray with all fixing accessories including jointing with existing position and testing complete all as spcecified and directed.
Supply,laying, jointing, testing and commissioning in replacement cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core complete all as spcecified and directed. (Note: Excavation earth work, sand cusioning, brick protection of cable shall be meaured & paid separately).
M&L earthing complete with copper plate of size 600 x 600 x 3.15 mm with copper earth strip of size 20 x 3 mm as earth lead buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge earth of the plate not less than 1.50 mtr below normal ground level, connected to copper strip (20 x 3 mm ) from earth plate to test point by means of brass bolts, nuts, check nuts and lead washers or copper riveted joint including char coal dust, common salt, funnel with wire-mesh, 20 mm dia light grade GI pipe for watering and 40 mm dia GI pipe light grade for protection of copper strip and excavation / earth work with PCC pit 1 : 3 : 6 type C2 using 40 mm graded stone aggregate and RCC cover of 40 mm thick with 1 : 2 : 4 type B-O using 12.5 mm graded stone aggregate reinforced with 6 mm dia mild steel round bar 75 mm C/C both way with two Nos 12 mm dia MS handle complete all as shown in electrical plate No 5 of SSR Part I, the rates includes testing charges complete all as specified and directed by Engineer-in-Charge. (Note: Earth strip up 7.5 length from test point has been included in quoted unit rate. Beyond 7.5 RM length of copper strip shall be measured & paid separetly).
AIR CONDITIONING WORK Supply and installation, commissioning and testing window type AC complete with cohordless remote control unit and inbuild air ionizer and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity as shown electric driven (single phase 4500 K cal/Hr (1.5 TR) with discharged cooled type rotory/scrolled type compressor operating on non-CFC refrigerent gas as per manufacturers recommondations including taking out/ dismantling BER AC from the existing location & transporting ,depositing to MES store yard complete all as specified and directed. (Note: Quoted unit rate shall be inclusive of addition/alteration required at site for fixing of ACs including proper finishing work).
Supply and installation, commissioning and testing window type AC complete with chordless remote control unit and inbuild air ionizer and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity as shown electric driven (single phase 6000 K cal/Hr (2 TR) with discharged cooled type rotory/scrolled type compressor operating on non-CFC refrigerent gas as per manufactures instutions incuding taking out/ dismantling BER AC from the existing location & transporting ,depositing to MES store yard complete all as specified and directed. (Note: Quoted unit rate shall be inclusive of addition/alteration required at site for fixing of ACs including proper finishing work).
Supply and installation, commissioning and testing of hi wall split type AC indoor & outdoor complete with chordless remote control unit and inbuild air ionizer and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity as shown electric driven (single phase 6000 K cal/Hr (2 TR) outer unit shall be fitted with discharged cooled type rotory/scrolled type compressor operating on non-CFC refrigerent gas as per manufacturers instructions including copper piping as required between both the units with suction pipe, discharge pipe and electric cable from inner unit to outer unit shall be properly included, taped and covered with heavy duty half cut PVC and properly fixed on wall/ceilings etc including PVC pipe 15 mm dia fixed with proper slope for drain pipe of air conditioner including taking out/ dismantling BER AC from the existing location & transporting ,depositing to MES storeyard complete all as specified and directed. (Note: Quoted unit rate shall be inclusive ofall the work requird for installation of split ACV like minor Addn/Altn, provision of powder quoted mild steel stands for fixing of out door units etc complete).
Supply, installation, commissioning and testing of automatic voltage stablizer of cap of 5 KVA suitable for AC upto 2 Ton for automatic operation single phase naturally air cooled indoor type and designed for input variation between 90V to 300 V with output voltage at 230 V with accuratcy of + 2.5 % complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 32 Amps fixed properly on in concealed position complete all as specisfied and directed.
M&L sub main wiring with 2 runs of 4 sqmm PVC insulated unsheathed copper cable multistrand 1100V grade with drawn in concealed PVC conduit not less than 19mm dia and one run of PVC insulated unserviceable of 4 sqmm as earth continuity conductor drawn in PVC conduit/casing and capping with accessories complete all as specified and directed. (Note- Two runs of 4 sqmm (phase & neutral) and one run of 4 sqmm as earth wire & one RM length of PVC conduit with fitting shall be measered as one unit i.e per RM).
S&F MCB 6-32 Amp single pole 10KA capacity having C- curve characterstics complete all as specified and directed.
FUEL EXTRACTION SYSTEM & EFFULENT DISPOSAL Design, Fabrication, Supply, installation of submerged heavy duty effluent collection tank suitable for capacity of 2200 liter. The tabk thickeness shall be minimum 10mm. The tank shall be made up of PP & lined with FRP coating of suitable thickness as per design. Tanks shall be capable of handling chemicals like ARDOX 633A-2526-6025, ORION 68, ZL 37-27A-2C-10B, CHROMIC ACID, RDP etc. The tank shall be equipped with openable type cover of suitable size for maintenance purpose. The cover shall be designed in specific manner for smooth operation. Tank price shall include cost of 02 Nos monoblock pump set in SS construction submersible/centrifugal type (1 working + 01 stand by) with appropriate heavy duty PVC pipe with PP ball valve for effluent collection of residual from the tank. The pump capacity shall be as design to drain residual effectively from the tank. All necessary valves required for the pump shall be part of the system. The rate quoted shall include cost of PE 100, 6,110 DN HDPE pipe for main header & smaller size HDPE pipe alongwith valve for connection up to main header from chemical bath tub to inlet of the tank with all necessary fittings like flanges, elbow Tee etc between existing chemical bath tub and tank to complete the work. Tank price shall include cost of electrical panel for 2 Nos pump. Electrical panel shall include 2 Nos starter for the pumps complete with incoming, outgoing shall be part of the system. The maximum length of the cable shall be 15 RM. Tank price shall be inclusive of necessary excavation for the tanks RCC foundation with required brick wall for housing the tank, appropriate drainage arrangement. Main cover for tank of suitable size and all kind of civil work to complete all as specified and directed.
Design, Fabrication, Supply, installation of submerged heavy duty effluent collection tank suitable for capacity of 1150 liter. The tank thickness shall be minimum 10mm. The tank shall be made up of PP & lined with FRP coating of suitable thickness as per design. Tanks shall be capable of handling chemicals like ARDOX 633A-2526-6025, ORION 68, ZL 37-27A-2C-10B, CHROMIC ACID, RDP etc. The tank shall be equipped with openable type cover of suitable size for maintenance purpose. The cover shall be designed in specific manner for smooth operation. Tank price shall include cost of 02 Nos monoblock pump set in SS construction submersible/centrifugal type (1 working + 01 stand by) with appropriate heavy duty PVC pipe with PP ball valve for effluent collection of residual from the tank. The pump capacity shall be as design to drain residual effectively from the tank. All necessary valves required for the pump shall be part of the system. The rate quoted shall include cost of PE 100, PN6,110 DN HDPE pipe for main header & smaller size HDPE pipe alongwith valve for connection up to main header from chemical bath tub to inlet of the tank with all necessary fittings like flanges, elbow Tee etc between existing chemical bath tub and tank to complete the work. Tank price shall include cost of electrical panel for 2 Nos pump. Electrical panel shall include 2 Nos starter for the pumps complete with incoming, outgoing shall be part of the system. The maximum length of the cable shall be 15 RM. Tank price shall be inclusive of necessary excavation for the tanks RCC foundation with required brick wall for housing the rank, appropriate drainage arrangement. Main cover for tank of suitable size and all kind of civil work to complete all as specified and directed. Note:- (a) The above scope covers successful collection of effulent from chemical bath tub and discharge up to the proposed tank by maintaining appropriate slope and successful discharge of chemical via ball valve provided above ground level through pumping. The rates quoted shall be inclusive of all the works required for successful complete of work
Design, Fabrication, Supply, installation, Testing of of fume extraction system of capacity 5000 CFM of make- Cleanion or Yanson or Anticor as approved by GE for OH line for traping the bioproduct gases produced during chemical reaction alongwith Acid/Alkali mist excess air being taken with them to scrubber for recovery and discharged into atmosphere as per standard of UPPCB. The system shall comprise of scrubber-Skin shall be made up of PP and coated with FRP lining of suitable thickness as agreed by Engr-in-charge. Scrubber shall be equipped with high efficiency>=90% honey comb pad sction. PVC mist eliminator shall be provided to eliminate mist. Sump tank of scrubber shall be made with MS and FEP lined with 4-5 thickness. The size of tank shall be as per site condition. Scrubber shall be provided with SISW blower designed for system static pressure depending upon the honey comb pad, mist eliminator, losses due to duct of 50 RM length, flexible pipe connection etc and as per the approval of Engineer in charge. Sound level should not exceed 85 DBA at a horizontal distance of 3 M. Scrubber shall be equipped with water spray nozzles. Water taknk and packing material, all manual valves require with crubber. Scrubber price shall include cost of one No monoblock centrifugal pumpset for spray of water to pad section with all necessary fittings. The pump capacity shall be as designed in accordance with engineer in charge. All necessary valves required for the pump shall be part of the system. Scrubbr price shall include cost of interconnecting PVC pipe for spray of water with all necessary fitting between pumpset and tank to complete the work. Scrubber shall be equipped with TEFC motor of suitable capacity and VFD compatible. Scrubber price shall include cost of electrical panel for 1 No pump and blower, Electrical panel shall include 2 Nos starter for the pump and blower complete with incolling, outgoing provision and metering devices. Electrical panel shall be CPRI approved. Electrical cable CU armoured of suitable size with suitable earthing wire for in coming and outgoing shall be part of the system. The maximum length of the cable shall be 15RM. Scrubber price shall be inclusive of necessary excavation for foundation of scrubber and making of foundation all complete all as specified and directed. Design, Supply, Installation, Testing of SS chimney of suitable dia and 15 Meter height shall be part of the extraction system. All kind of civil work related to chimney shall be contractor scope of work. Note:- (a) The quoted rate by the contractor shall deemed to be inclusive of the cost toward design and execution of fume extraction system consisting of lip suction hood, flexible hoses, PPGL/FRVC duct and any modification/additional items as per site requirement complete a specified and directed. (b) The contractor has to give two year warranty for FES from the certified date of completion. (c) Contractor shall carryout comprehensive maintenance of equipment under two years dfect liability period from the very next certified date of completion. (d) Th design of fume extraction procedure and all stages involved in the fume extraction process shall be got designed from any one of the approved OEMs and design is to be vetted by IIT or Govt Engineering College/Competent Polution Control Deptt. (e) Inspection points shall be provided in chimney & fume extraction system to inspect the spraying system. Make for item No 1 to 3:- SEEPL/Thermax Ltd/Fontus water Pvt Ltd
M&L 50 mm bore HDPE pipes PE 80, PN-6 pressure rating laid in trenches or in floors complete all as specified and directed.
Supply, lay of fix GI pipe light grade of size 40mm dia with and including provision of all fittings complete to walls and ceilings or laid in floors or trenches complete all as specified and directed.
Supply, lay or fix GI pipe medium grade of size 40 mm dia with and including provision of all fittings complete to walls and ceilings or laid in floors or trenches complete all as specified and directed.
M&L GI pipe medium grade ISI marked with all necessary fittings laid in trenches/floor /wall of size 20mm bore complete all as specified and directed. Make- Jindal/TATA/Prakash/Surya/Zenith
Supply and lay cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed. (Note:- Excavation, earth work, sand cushioning, brick protection shall be measured & paid seperately).
M&L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
M&L dry river sand for cushioning for laying cable in trenches free for vegetation complete all as specified and directed. (Note:- Punned depth of sand cushioioning shall be measured for payment purpose).
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 in depth and getting out for taking out/laying pipes in soft/loose soil complete all as specified and directed.
Returning, filling including spreading levelling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil after pipes are laid complete all as specified and directed.
Removing of excavated material not exc 50 mtr distance and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L eathing complete with galvanized steel earth electrode, 60 cm x 60 cm x 6 mm thick, buried directly in ground (not less than 2.5 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion and PCC pit made out of PCC (1:3:6) type C-1 using 20mm graded stone aggregate & 40 mm thick precast RCC (1:2:4) cover type B1 using 20mm graded stone aggregate reinforced with 8 mm dia TMT BarS @ 75 mm C/C both ways with 02 Nos lifting handles of 12 mm dia MS plain bar, GI pipe 20 mm dia ' light grade' with funnels & wire mesh for watering and 40 mm dia ' light grade' GI pipe for earth strip protection upto 7.5 Rm in length including excavation & earthwork and filling charcoal dust and common salt in layers etc complete all as specified and directed. Note : Galvanized earth strip 32 x 6 mm and GI protection pipe beyond 7.5 m length from earth test point shall be measured and paid separately
Supply & fixing for GI strip 32x6 mm on wall/batten or recessed or buried in ground complete all as specified and directed.
V S BUILDER
M/S ALOK SRIVASTAVA
MD BUILDER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .