Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹25.1 LAccepted-AOC | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹27.2 LRejected-Finance | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹30.4 LRejected-Finance 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FORTH₹30.5 LRejected-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | FORTH | Rejected-Finance BEING NOT LOWEST | |
| 5 | FIFTH₹31.0 LRejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | FIFTH | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹26.5 L
EMD Value
₹53,000
Closing Date
24 Apr 2022, 6:00 pmClosed
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD KEMPAPURA YEMALUR POST BANGALORE PIN 560037
SPECIAL REPAIR TO LIGHTENING ARRESTORS IN VV CAMP AND LT PANELS AT SDI UNDER GE AF MARATHAHALLI
2022_MES_515573_1
8935/E8
Open Tender
Civil Works
Works
180 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹53,000
Yes
11 Aug 2022
28 Mar 2022
29 Apr 2022
28 Mar 2022
24 Apr 2022
11 Apr 2022
Amount
M & L for Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 25 x 4 mm as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified. NOTE: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
M & L for Earthing complete with copper plate electrode 600 mm x 600 mm x 3.15 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to copper strip 20 x 3 mm as earthing lead by means of copper bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified. NOTE: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Material & labour for fixing of Earth continuity conductor Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground ,with nut bolts at joints , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles,equipments or any other indicated situation for loop earthing etc, Aluminium strip fixed on with epoxy insulator of suitable size including taking down old strip all as specified and directed by Engineer-in-Charge.
Material & labour for fixing of Earth continuity conductor GI strip 25 x 4 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground ,with nut bolts at joints , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles,equipments or any other indicated situation for loop earthing etc, GI strip fixed on with epoxy insulator of suitable size including taking down old strip all as specified and directed by Engineer-in-Charge.
Supply and fixing Air termination, single pointed, aluminium rod 12mm dia and 300mm long all as specified and directed by Engineer-in-Charge.
Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of size 90 mm dia suitable for 0.4 mpa working pressure.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealing protective piping in floors/walls and making good.
Earth work excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth getting out in hard/dense soil and for laying of under ground cable and foundation of poles.
Returning, filling in, including spreading, levelling, watering and well ramming etc in layers not exceeding 25cm each in hard/dense soil.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point
S & F GI tubing light grade 50 mm bore for earth strip under roads, crossings/ culverts including jointing at ends, complete all as specified.
Supply and fix test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 03 Nos 8mm dia 25mm long hex including MS Box with bus bar support size 150mm x 150mm x 100mm covered with hylem sheet.
Cutting PCC Concrete in ground floors and pavings n exc 15 cm thickness unreinforced (below or above ground level)
S&F Aviation Obstruction light with 75 VA Neon Lamp die cast aluminium alloy housing, inbuilt 75 VA step up transformerheat resistent, clear thick glass and accessories all as specified and directed by Engineer-in-Charge.Make - Bajaj cat No BJACL 1 with neon lamp or equivalent in CG/PHILIPS.
M & L for sub main wiring complete with two runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
Taking down of old unserviceable LT panel board and Supply, installation, testing and commissioning of indoor type cubicle panel board suitable for 3 phase 4 wire 415 V, 50 Hz and tested at CPRI for 415 volts factory fabricated in an approved factory having modern fabrication process powder coating in approved shared having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS : 8623/93 comprising. The outer shell shall be made out of 3 mm thick CRCA sheet and MS angle section 40x40x6 mm base frame factory fabricated with front openable, double door system lockable/openable. The bottom of the outer shell contains a detachable plate having size with glands. The outer shell shall be mounted on stand having zine coating not less than 80 microns. Provision of threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP - 56. Inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, TPN aluminum bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleave. All control wires shall be with 2.5 sqmm multi strand copper conductor and shall be propely bunched, tied, ferruled for proper identification and crimped with adequate size of lugs all as specified and directed by Engr in charge. (Transformer No. 4 panel) Make: Legrand or equivalent in Indoasian etc. INCOMING (a) Air circuit breaker TPN 800 Amp 50 KA Manual fixed type -02 Nos (b) RYB indication Lamp with Control MCB/RRR with control MCB -02 set (c) VAF Meter-2 Nos (d) 800/5A, Cl.1, 15VA CT's- 2 sets Mechanical Interlock between Incomers OUTGOING Feeders Consists of (a) 800 Amp TPN 50 KA Manual fixed type -02 Nos (b)1200A TPN+E Aluminium Busbar with Heat Shrinkable Sleeves Note ;- Colour Siemens Grey Coated
Taking down of old unserviceable MCCB in existing LT panel No. 1 (DG room) and supply and fixing of : INCOMING (a) MCCB 4 pole 400 Amp 36 KA 415 Volt -1 No. with Four Optimum Frames,Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable – 5 to 10In, Breaking Capacity-36kA,Option for In built or add on module for Earth Leakage Protection,Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A, Adjustable tripping: 0 - 0.3 - 1 - 3s, Suitable for Isolation Make: Legrand or equivalent in indoasian etc. Bus Bar (a) 630 Amps capacity Aluminium bus bar with sleeves (b) SPDR Link set FP DPX 400/630 A (c) Vary depth SRH DPX3 160 & 250 as required for panel all as specified & directed 7 Nos (d) SPDR Link set TP DPX 160 A, 7 Nos OUTGOING (a) MCCB 3 pole 100 Amps 25 KA 415 Volt -05 No.with Four Optimum Frames,Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable – 5 to 10In, Breaking Capacity-25 kA,Option for In built or add on module for Earth Leakage Protection,Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A, Adjustable tripping: 0 - 0.3 - 1 - 3s, Suitable for Isolation Make: Legrand or equivalent in Indoasian etc (b) MCCB 3 pole 63 Amps 16 KA 415 Volt-2 No. with Four Optimum Frames,Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable – 5 to 10In, Breaking Capacity-16kA,Option for In built or add on module for Earth Leakage Protection,Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A, Adjustable tripping: 0 - 0.3 - 1 - 3s, Suitable for Isolation Make: legrand or equivalent in Indoasian etc Note ;- Painting of existing panel with colour Siemens Grey Coated with minor repaires to LT panel ( including fittings & fixture as per site requirement)
Taking down of old unserviceable MCCB in existing LT panel No. 2 (DG room) and supply & fixing of : INCOMING (a) MCCB 4 pole 200 A 25 KA 415 Volts -2 Nos with Four Optimum Frames,Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable – 5 to 10In, Breaking Capacity-25 kA,Option for In built or add on module for Earth Leakage Protection,Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A, Adjustable tripping: 0 - 0.3 - 1 - 3s, Suitable for Isolation Make: Legrand or equivalent in Indoasian etc. Bus Bar 300 Amps capacity Aluminium bus bar with sleeves -2 Nos FP SPDR Link Set For DPX 250ER -2 Nos OUTGOING (a) MCCB 3 pole 100 Amps 25 KA 415 Volt - 1 No. with Four Optimum Frames,Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable – 5 to 10In, Breaking Capacity-25KA,Option for In built or add on module for Earth Leakage Protection,Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A, Adjustable tripping: 0 - 0.3 - 1 - 3s, Suitable for Isolation, Make: 420045,420161,625002 of Legrand or equivalent in Indoasian etc (b) MCCB 3 pole 63 Amps 16 KA 415 Volt -2 Nos with Four Optimum Frames,Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable – 5 to 10In, Breaking Capacity-16kA,Option for In built or add on module for Earth Leakage Protection,Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A, Adjustable tripping: 0 - 0.3 - 1 - 3s, Suitable for Isolation Make: Legrand or equivalent in Indoasian etc. (c) Vary depth SRH DPX3 160 & 250 as required for panel all as specified & directed - 3 Nos (d) SPDR Link set TP DPX 160 A -3 Nos (e) TP C32A AC MCB with Intergrated Label holder on top of Dolly.Each Note ;- Painting of existing panel with colour Siemens Grey Coated with minor repaires to LT panel ( including fittings & fixture as per site requirement)
Taking down of old unserviceable MCCB in existing LT panel board (Tech wing) and supply & fixing of : INCOMING (a) MCCB 4 pole 100 A 25 KA 415 Volts - 2 Nos with Four Optimum Frames,Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable – 5 to 10In, Breaking Capacity-25kA,Option for In built or add on module for Earth Leakage Protection,Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A, Adjustable tripping: 0 - 0.3 - 1 - 3s, Suitable for Isolation Make: Legrand or equivalent in Indoasian etc. (b) Vary depth SRH DPX3 160 & 250 as required for panel all as specified & directed - 2 Nos (c) SPDR Link set TP DPX 160 A - 2 Nos (d) Multi - function meter RS485CI 1.0 Accuracy (Each) Note ;- Painting of existing panel with colour Siemens Grey Coated with minor repaires to LT panel ( including fittings & fixture as per site requirement)
Taking down of old unserviceable MCB in existing LT panel board (AFNET) and supply & fixing of Following:- (a) TP 32 C32A AC MCB with Integrated Lable holder on top of Doly,- 4 Nos with ISI marked as per IS/IEC 60898-1 2002,Integrated label holder,Sliding bottom clamp,Efficient air channels,Color coded On/Off indication on dolly,Biconnect lower terminals,IP 20 protected terminals,Sliding shutters,Compatible with signal and control Auxiliaries Make: Legrand or equivalent in Indoasian etc.
Taking down of old unserviceble MCB in existing LT panel board (URC)and supply & fixing of : (a) TP 32 C32A AC MCB with Integrated Lable holder on top of Doly,- 3 Nos with ISI marked as per IS/IEC 60898-1 2002,Integrated label holder,Sliding bottom clamp,Efficient air channels,Color coded On/Off indication on dolly,Biconnect lower terminals,IP 20 protected terminals,Sliding shutters,Compatible with signal and control Auxiliaries Make: Legrand or equivalent in Indoasian etc.
Taking down of old unserviceable MCCB/MCBs in existing LT panel board (side of URC store) and supply & fixing of : INCOMING (a) MCCB 4 pole 100 A 25 KA 415 Volts - 1 No with Four Optimum Frames,Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable – 5 to 10In, Breaking Capacity-25kA,Option for In built or add on module for Earth Leakage Protection,Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A, Adjustable tripping: 0 - 0.3 - 1 - 3s, Suitable for Isolation Make: Legrand or equivalent in Indoasian etc (b) Vary depth SRH DPX3 160 & 250 as required for panel all as specified & directed - 1 Nos (c) SPDR Link set TP DPX 160 A -1 Nos OUTGOING (a) SP C20A AC MCB with Integrated Lable holder on top of Doly,- 20 Nos with ISI marked as per IS/IEC 60898-1 2002,Integrated label holder,Sliding bottom clamp,Efficient air channels,Color coded On/Off indication on dolly,Biconnect lower terminals,IP 20 protected terminals,Sliding shutters,Compatible with signal and control Auxiliaries Make: Legrand or equivalent in Indoasian etc.
M & L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed
S & L sub class B burnt bricks for cable protection complete as specified as directed
Taking down of old UG cable and Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3½ core connected with suitable lugs / ferrules including taking out the existing unserviceable cable
Taking down of old UG cable and Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3½ core connected with suitable lugs / ferrules including taking out the existing unserviceable cable
Supply & Fix PVC Insulated and FR PVC Round Sheathed,Copper Conductor cable (Industrail Flexible)1100 Volt, conforming to IS 694, 4 core 10sqmm, all as directed and Specified.
Boring of holes under road ,pavement hard standing by trenchless technology using ultra sounding,technique including HDPE pipe 150 mm dia
M & L for GI tubing light grade 80mm with all accessories for cable protection fixed on poles/bldgs of laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed
M & L for GI tubing light grade 50mm with all accessories for cable protection fixed on poles/bldgs of laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed
M & L for PCC 1:3:6 type C1 with 20mm graded crushed stone aggregate in copping of poles/filling road cutting stays ,incl necessary form work, all as specified and as directed
B5BUILDING SOLUTIONS
G K CONSTRUCTIONS
M/S - KRUPA ELECTRICALS
GKR and CO
Vishwas Enterprises
M/S J S PRAKASAM
M/S Suresh Raju
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .