Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.9 L+₹14,825.85 (0.62%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹26.0 L+₹2.2 L (9.18%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted other then L1 | |
| 4 | L4₹27.5 L+₹3.8 L (15.8%)Rejected-Finance | L4 | Rejected-Finance Highest bid quoted other then L1 | |
| 5 | L5₹31.0 L+₹7.2 L (30.4%)Rejected-Finance | L5 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹51,400
Closing Date
10 Jan 2022, 6:00 pmClosed
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
PROVN OF CERTAIN SANCTION MW AND SPECIAL REPAIRS WORKS AT MILITARY STATION SRI GANGANAGAR
2021_MES_492511_1
GE SGNR/ TOK-64 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE Sri Ganganagar
D Class a(i) and a(ii) and b(i) for un-enlisted, refer NIT para 8
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹51,400
Yes
31 Jan 2022
4 Dec 2021
12 Jan 2022
4 Dec 2021
10 Jan 2022
11 Dec 2021
Amount
Dismatiling brick tiles or terracing tiles, single layer on tempered wall of raw water reservoir complete all as specified and directed by Engineer - in - Charge.
M&L 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on 15mm thick layer of CM 1:6 bedding complete all as specified and directed by Engineer-in-charge.
All as per above item no 2 but except tiles complete all as specified and directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer - in - Charge.
Demolition concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer - in - Charge.
M&L 100 mm thick, PCC 1:4:8 Type D-2 using 40mm graded aggregate in foundation , filling and mass concrete in sub base or bases etc. complete all as specified and directed by Engineer - in - Charge
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge.
M&L Machine pressed precast rubber moulded concrete coloured interlocking paver block any shape and size confirming to IS 15468-2006 of 60 mm thickness with grey cement and pigment M-35 Grade 20mm graded stone aggregate) complete all as specified and directed by Engineer - in - Charge.
Demolition of brick work built in cement mortar of any description complete all as specified and directed by Engineer - in - Charge.
M&L for brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 but except bricks complete all as specified and directed by Engineer - in - Charge.
Taking down cement plaster any description including raking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed by Engineer - in - Charge.
M&L 15 mm thick rendering in CM 1:6 on brick / concrete wall surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 15 mm thick rendering in CM 1:4 on brick / concrete wall surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint, over a coat of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surface of walls and applying one coat of acrilic wall putty and then applying two coats of distemper oil emulsion complete all as specified and directed by Engineer - in - Charge.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape,etc., n exc. 1.5 m high from base complete all as specified and directed by Engineer - in - Charge.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape,etc., exc. 1.5 m n exc. 3.0 m high from base complete all as specified and directed by Engineer - in - Charge.
Removing excavated material out side MD land n. exc. 50 m & depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new wooden and wood base surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed by Engineer-in-Charge.
Dismantling galvalumesheets (corrugated semicorrugated ,Plain or corrugated steel sheeting,any gauge, thickness etc) sheet in roof covering complete all as specified and directed by Engineer-in-Charge.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated Mangalore tiles profile steel sheet 0.50mm thick of an colour (red) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer - in - Charge
S&F pre-painted galvalume aluminium zinc coating GI based plain Mangalore tiles profile steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engineer - in - Charge.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed by Engineer - in - Charge
M&L for PCC (1:4:8) type D-2, (40 mm graded stone aggregate) as in foundation filling in mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for 75mm thick cement concrete (1:3:6) type C-2, (20 mm graded stone aggregate) as in sub base of floor complete all as specified and directed by Engineer - in - Charge
S&F power coated aluminium snap grid frame work for false ceiling size 605x605 mm including hangers complete all as specified and directed by Engineer - in - Charge
M&L for Providing and fixing Gypsum Board 12mm thick size (600x600) in false ceiling fixed with screw as per manufacturers instructions or tiles for insulation and accoustic purposes, 60cm x 60cm in size laid/inserted to timber/GI/aluminium framework with screws complete all as specified and directed by Engineer - in - Charge
Taking down existing false ceiling of size 600x600x12 mm thick for false ceiling panel or tiles for insulation and accoustic purposes, 60cm x 60 cm in size and refixing the same in the same laid/inserted to timber/GI/aluminium framework with screws and power coated aluminium snap grid frame work for false ceiling including hangers complete all as specified and directed by Engineer - in - Charge
M&L for precast cement concrete 1: 2:4 Type B-1 (20 mm graded stone aggregate) for as in block masonry/kerb stone with solid blocks, exc. 10 cm in width and setting in mortar 1:4 complete all as specified and directed by Engineer - in - Charge
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engineer - in - Charge
Taking down carefully by unscrewing from false ceiling boards/outlet boxes, fittings and fixtures such as lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings,2X2 panel light ,suspension light,hanging light,ceiling fan ,switches,sockets, ceiling roses, lamp holders, brackets, ,and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse)
Labour only for existing concealed conduit point wiring complete for light/ fan point with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in existing PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , for one light/ fan point controlled by one switch , complete all as specified and direced by the Engineer in charge.
Fixing only existing Recess mounting LED luminaire 2x2 ft 36 W , suspension light fitting and hanging light fitting White powder coated CRCA housing with LEDs. Seamless front frame with flat white high transmission acrylic cover and fixed electronic driver (surge protecter) complete all as specified and direced by the Engineer in charge.
Hanging only ceiling fan 1200/1400 mm sweep and connecting up to cable from ceiling rose or connector to fan complete all as specified and direced by the Engineer in charge.
M & L for concealed conduit point wiring complete for light on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes 60mm deep ,suitable length and 1. 2 mm thickness for mounting, switches, sockets,fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced by the Engineer in charge.( Make - Finolex/Anchor/Havells)
S&F recess mounting 2 X 2 feet 36 watt LED luminaire with high efficiancy PMMA diffuser sogt glare free light with driver ,holders, LED Lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size ,powder coated CRCA housing with LEDs,seamless front frame with high transmission acrylic cover and fixed electronic driver (surge protector) complete all as specified and directed by Engineer - in - Charge. Make:Crompton cat part no :LCTLRNE-36-FO-CDL or equivalent make in Havells,Bajaj
S & F decorative,surface mounting,dome shaped pendent in green and black finishes including 7.5 W A60 LED filament lamp Make : Havells cat part no.LHFHDPE1TN1K020 or equivalent make in crompton, Bajaj,Phillips
S & F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engineer - in - Charge.
M & L for point wiring using approved color coding as per IS with zero halogen flame retardant (HFFR), smoke free,non toxic ,non corrossive installation cable with UNILAY construction copper conductor 1.5 Sqmm (nominal area) ,single core insulated and unsheathed stranded cable 1100 volt grade ISI - 694 marked IEC and FIA approved in and including heavy duty electric resistance welded (ERW) stove enameled conduit ,heavy duty ISI marked as per IS -9557 (part-1) 1980 for one light point controlled by one switch including HFFR insulated unsheathed unilay construction copper conductor 1.5 sqmm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly complete all as specified and directed by Engineer - in - Charge.
M & L for concealed conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes suitable length and thickness for mounting, switches, sockets,fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced by the Engineer in charge.(Make of cable - Havells/Anchor/Finolex and conduit pipe:-AKG/Plaza/Suprem)
All as per Srl item No -43 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 43 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engineer - in - Charge.
S & F switch socket combination 5 pin, type 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F switch socket combination 6 Pin, 5/16 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer - in - Charge.
S & F ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
S & F flame proof LED light fitting 2 x 16 Watt,CMRI certified recommended for gas/vapour group of IIA & IIIB,Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tubelight fixture driver ,holders,connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by engineer-in-charge
S & F Water tight bulk head fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED lamp all as specified and directed by Engineer - in - Charge (Make:Havells cat part no : HEXAFT10WLED857SSYMBOPC, Bajaj cat part no. BIBWP 10W LED, Philips Cat part No. WT202W LED6S CW PSU S2 PC)
S&F security light fitting LED TYPE 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge (Make:Havells cat part no: ENDURAPEARLSL25WLED757SASYTOPCMP, Bajaj cat part no. BRLEP 25W LED WH, Crompton cat part no. LSTS-25-CDL-M)
S & F for flame proof exhaust fan 380 mm sweep (15") single phase 0.25 HP motor , 1440 RPM ,2350 cfm,by grouting both ends in wall upto required length and making hole of suitable size in wall complete with louvers and connecting up including provision of cable from ceiling rose or connector to fan as specified and directed by Engineer - in - Charge.
S & F MCB ‘B’ series type suitable for 415 volts, AC supply 63 Amps, (TP )Tripple polewith over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. (Make - Siemens/Havells / Legrand )
S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , (SP )single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. (Make - Siemens/Havells / Legrand )
S&F Sheet metal enclouser for doble door Vertical DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mouting VTPN 12 Way 415 Volt ISI marked 250Amps busbar stove enameled dust and vermin proof,IP:43 protection suitable for incorporation FP MCCB(V-Tech) N1 Frame upto 125A ,Isolators and including give connection with wire and cable etc complete all as specified and directedby engineer -in-charge (Make - Siemens/Havells / Legrand)
S&F MCCB TP&N 125 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge. (Make -Siemens/Havells / Legrand)
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point with all acessories all as specified or indicated including testing on completion all as specified and directed by Engr -In - Charge
Excavation in trenches not exceeding 1.5 mtr wide and not ecxceedinf 1.5 mtr depth for laying of cables complete all as specified and directed by Engineer - in - Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer - in - Charge.
Removing surplus soil n. exc. 50 m & depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer - in - Charge
Supply & filling/ laying a layer of dry coarse sand 8 cm thick before laying ofcable and 15 cm thick after laying of cable complete all as specified and directed by Engineer - in - Charge. Note:- After punning drain 18 cm will be measured for payment.
M&L for brick protection layer with one brick wide using sub class ‘B’ bricks laid flat across the cable complete all as specified and directed by the Engineer in charge.
Supply and lay jointing and testing and commissioning of 50 Sqmm x 3.5 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
S & F Rigid non-metallic PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
Supply and lay GI pipe 50 mm light grade for cable protection in walls trenches or any situation including clamp nut bolt etc complete all as specified and directed by Engineer-in-Charge.
M&L for draining out of waste water from desludge tank with the help of diesel pump set and dry the slag of tank for removal complete all as specified and directed by Engineer-in-Charge.
M&L for removing sludge/mud/silt/foreign material from tank by means of mechanical source or manually including working in foul condition and disposing the same within 2 Km inside the defence/ cantt area using suitable mode of transportaion strictly preventing the waste to fall over the road complete all as specified and directed by Engineer-in-Charge.(Note:- Contractor should be advised to visit the site before quoting his rate
Removing vegetations /bushes/foreign materials etc around the periphery/path of desludge tank along with necessary branch cutting hanging hanging over the tank area and vegetation grow over the tank bed complete all as specified and directed by Engineer-in-Charge.
Note : Notes : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
KHANNA CONSTRUCTIONS
M/s Chopdar Builders
Aggarwal brothers and company
M/s Durga Constructions Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .