Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹64.4 L+₹3.9 L (6.41%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance L2 FOR REJECTED | |
| 3 | L3₹66.6 L+₹6.1 L (10.1%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L3 | Rejected-Finance L3 FOR REJECTED | |
| 4 | L4₹68.9 L+₹8.4 L (13.9%)Rejected-Finance H NO 1 BLOCK NO 2 SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-Finance L4 FOR REJECTED | |
| 5 | Rejected-Technical | - | Rejected-Technical Slow Progress |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
8 Mar 2022, 6:00 pmClosed
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO CWE SGNR 63 OF 2021-22 CONVERSION OF LT OH LINE INTO UG LT CABLE AND OLD PCC POLE TO OCTAGONAL POLES AT JS ENCLAVE AT SRIGANGANAGAR MIL STATION (2ND CALL)
2022_MES_501938_2
CA NO. CWE SGNR - 63 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SRI GANGANAGAR
CLASS-C
CATEGORY-b(i)
10 documents required · 10 mandatory
₹1,000
₹1.3 L
Yes
7 Apr 2022
15 Feb 2022
10 Mar 2022
15 Feb 2022
8 Mar 2022
22 Feb 2022
Amount
Supply & Fixing and testing of LT cable 1100 volts grade XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor suitable for earthed system of size 240 sqmm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. (Excavation, earth work, bricks and sand cushioning shall be measured and paid separately).
All as per Srl item No. 01 here-in-before but for size 185 sqmm 3½ core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but for size 120 sqmm 3½ core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but for size 95 sqmm 3½ core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but for size 70 sqmm 3½ core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but for size 50 sqmm 3½ core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but for size 25 sqmm 4core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but for size 16 sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but for size 10 sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but for size 10 sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
M&L for earthing of electric equipments with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick, buried directly in ground (earth plato not less than 2.25 metrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connecting to and including galvanized iron strip 32x6mm as earthing lead by means of galvanized iron bolts, nuts, check nuts and washers, check nuts of GI steel all as shown in electric plate no 3 in SSR part-I (2009) connected to earth test point made out of aluminum of size 75x75x10 mm all as specified and indicated complete and including charcoal dust, salt etc and GI protection pipe, medium grade 40 mm and GI watering pipe 20 mm, medium grade with with funnel and wire mesh, 40 mm thick pre cast RCC 1:1 1/2:3 (nominal mix) cover reinforced with XPM weight not less than 4 kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3 mm frame for cover, PCC 1:2:4 (type B1) (normal mix) pit, excavation and earth work in any type of soil and connected complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing of LT flexible FR PVC insulated round sheathed, copper conductor (flexible) industrial cable, 1100 volt conforming to IS-694 suitable for on poles and in ducts, size of 3 core 2.5 sqmm, complete all as specified and directed by Engr-in-Charge.
Supplying, installing, commissioning and testing of factory made LT Panel board of size 1.2x1.2x0.6m ,out door CPRI aprroved of cubical type made out of 3.15 mm thick CRCA sheet confirming to IS-8623 out dooor type totally enclosed double door hinged type front & rear opening weather proof dust vermin proof with canopy slope type powder coated painting locking arrangement, magnetic catch as directed entry holes and glands of siutable size of incoming/outgoing cable mounted on including MS angle iron stand fabricated out of 50x50x6mm angle iron frame with a clearance of at least 0.45 mtr above ground level and 0.3 mtr below groundlevel including required PCC for foundation and copping , internal coper control wiriing suitable size for instrument/indicators etc suitable size of copper strip for power cable connection from copper bus bar of high quality electrical grade of rating 1.5 times for incomer including removing all panel connection and complete all as specifed and directed with following accessories. INCOMING. (a) Micro processor based release MCCB 400A, 35KA, 4 pole , 415 volt 50HZ . -01 No (b) Set of three phase indicating lamps-01 Set. (c) Panel mounted LCD display meter in 96x96 sqmm flush mounted case accuracy class 1.0 to o.5 measure Voltage,Current,Frequency ,power factor,,Power ,THD ,30 days load survey relays with suitable size of CTs Make: HPL cat part No emifis plus or equivalent OUTGOING. (a) Micro processor based release MCCB 160 A, 35 KA, 4 Pole 415 V, 50 Hz- 02 Nob) MCCB 4 pole 63A ,25 KA- 6 No Note :- LT Bus bar 3 phase and neutral made out of copper strip 1 No. capacity and rating 1.1 times of incomer breaker -01 set.
All as per item No 13 here in before but comprising of following :- INCOMING. (a) Micro processor based release MCCB 400 A, 35KA, 4 pole , 415 volt 50HZ . -01 No (b) Set of three phase indicating lamps-01 Set. (c) Panel mounted LCD display meter in 96x96 sqmm flush mounted case accuracy class 1.0 to 0.5 measure Voltage,Current,Frequency ,power factor,,Power ,THD ,30 days load survey relays with suitable size of CTs Make: HPL cat part No emifis plus or equivalent OUTGOING. (a) Micro processor based release MCCB 250 A, 4 pole, 415 volts, with breaking cap 35 KA-01 Nos ,TAB2 Adjustable tharmal & Fixed Magnatic Type. (b) MCCB 4 pole 63A ,25 KA- 6 No Note :- LT Bus bar 3 phase and neutral made out of copper strip 1 No. capacity and rating 1.1 times of incomer breaker -01 set.
All as per item No 13 here in before but comprising of following:- INCOMING. (a) Micro processor based release MCCB 4 pole, 415 volts, 160 A Amp with breaking cap 35 KA-01 Nos ,TAB2 Adjustable tharmal & Fixed Magnatic Type (b) Set of three phase indicating lamps-01 Set. (c) Panel mounted LCD display meter in 96x96 sqmm flush mounted case accuracy class 1.0 to 0.5 measure Voltage,Current,Frequency ,power factor,,Power ,THD ,30 days load survey relays with Rs 485 with suitable size of CTs Make: HPL cat part No emifis plus or equivalent OUTGOING. (a) MCCB 4 pole, 415 volts, 63 Amp with breaking cap 25 KA-06 Nos ,TAB2 Adjustable tharmal & Fixed Magnatic Type Note :- LT Bus bar 3 phase and neutral made out of copper strip 1 No. capacity and rating 1.1 times of incomer breaker -01 set.
All as per item No 13 here in before but comprising of following :- INCOMING. (a) Micro processor based release MCCB 400A, 35KA, 4 pole , 415 volt 50HZ . -01 No (b) Set of three phase indicating lamps-01 Set. (c) Panel mounted LCD display meter in 96x96 sqmm flush mounted case accuracy class 1.0 to 0.5 to measure Voltage,Current,Frequency ,power factor,,Power ,THD ,30 days load survey relays with suitable size of CTs. Make: HPL cat part No emifis plus or equivalent OUTGOING. (a) Micro processor based release MCCB 4 pole, 415 volts, 160 A Amp with breaking cap 35 KA-03 Nos ,TAB2 Adjustable tharmal & Fixed Magnatic Type Note :- LT Bus bar 3 phase and neutral made out of copper strip 1 No. capacity and rating 1.1 times of incomer breaker -01 set.
All as per item No 13 here in before but comprising of following :- INCOMING. (a) MCCB 125 A, 35KA, 4 pole , 415 volt 50HZ . -01 No. (b) Set of three phase indicating lamps-01 Set. (c) Panel mounted LCD display meter in 96x96 sqmm flush mounted case accuracy class 1.0 to 0.5 measure Voltage, Current, Frequency, power factor, Power ,THD ,30 days load survey relays with suitable size of CTs. Make HPL cat part No emifis plus or Equivalent OUTGOING. (a) MCCB 4 pole, 415 volts, 63 Amp with breaking cap 25 KA-06 Nos ,TAB2 Adjustable tharmal & Fixed Magnatic Type Note :- LT Bus bar 3 phase and neutral made out of copper strip 1 No. capacity and rating 1.1 times of incomer breaker -01 set.
All as per item No 13 here in before but comprising of following :- INCOMING. (a) Microprocessor based MCCB 400 A, 35KA, 4 pole , 415 volt 50HZ . -01 No. (b) Set of three phase indicating lamps-01 Set. (c) Panel mounted LCD display meter in 96x96 sqmm flush mounted case accuracy class 1.0 to 0.5 measure Voltage,Current,Frequency ,power factor,,Power ,THD ,30 days load survey relays with suitable size of CTs Make: HPL cat part No emifis plus or equivalent OUTGOING (a) MCCB 4 pole, 415 volts, 200 Amp with breaking cap 35 KA-01 Nos ,TAB2 Adjustable tharmal & Fixed Magnatic Type. (b) MCCB 4 pole, 415 volts, 160 Amp with breaking cap 35 KA-01 Nos ,TAB2 Adjustable tharmal & Fixed Magnatic Type. (c) MCCB 4 pole, 415 volts, 63 Amp with breaking cap 25 KA-05 Nos ,TAB2 Adjustable tharmal & Fixed Magnatic Type Note :- LT Bus bar 3 phase and neutral made out of copper strip 1 No. capacity and rating 1.1 times of incomer breaker -01 set.
All as per item No 13 here in before but comprising of following :- INCOMING. (a) MCCB 125 A, 35KA, 4 pole , 415 volt 50HZ . -01 No. (b) Set of three phase indicating lamps-01 Set. (c) Panel mounted LCD display meter in 96x96 sqmm flush mounted case accuracy class 1.0 to 0.5 measure Voltage,Current,Frequency ,power factor,Power ,THD ,30 days load survey relays with suitable size of CTs Make: HPL cat part No emifis plus or equivalent OUTGOING. (a) MCCB 4 pole, 415 volts, 63 Amp with breaking cap 25 KA-05 Nos ,TAB2 Adjustable tharmal & Fixed Magnatic Type Note :- LT Bus bar 3 phase and neutral made out of copper strip 1 No. capacity and rating 1.1 times of incomer breaker -01 set.
All as per item No 13 here in before but comprising of following :- INCOMING. (a) MCCB 125 A, 35KA, 4 pole , 415 volt 50HZ . -01 No. (b) Set of three phase indicating lamps-01 Set.(c) Panel mounted LCD display meter in 96x96 sqmm flush mounted case accuracy class 1.0 to 0.5 measure Voltage,Current,Frequency ,power factor, Power ,THD ,30 days load survey relays with suitable size of CTs Make HPL cat part No emifis plus or equivalent
All as per item No 13 here in before but comprising of following :- INCOMING. (a) MCCB 160 A, 35KA, 4 pole , 415 volt 50HZ . -01 No. (b) Set of three phase indicating lamps-01 Set. (c) Panel mounted LCD display meter in 96x96 sqmm flush mounted case accuracy class 1.0 to 0.5 measure Voltage, Current, Frequency ,power factor,Power ,THD ,30 days load survey relays with suitable size of CTsMake HPL cat part No emifis plus /equiavalent OUTGOING. (a) MCCB 4 pole, 415 volts, 63 Amp with breaking cap 25 KA-07 Nos ,TAB2 Adjustable tharmal & Fixed Magnatic Type Note :- LT Bus bar 3 phase and neutral made out of copper strip 1 No. capacity and rating 1.1 times of incomer breaker -01 set.
Supply and installation hot dip galvanised octagonal poles 7 mtr height with 155mm bottom & 70 mm top A/F made up of 3 mm thick HT sheet alongwith base plate of size 250x250x16 mm (Door with Hinge) with 4 nos of M24 x 750 mm high 'J' type EN 8 grade foundation bolts along with template with inbuilt junction box having 6 A single pole "B" class mcb. Make : Surya/Bajaj/Jindal or equivalent
Supply and fixing of 1.5 m long Hot dip galvanised single arm bracket made up of 40 NB dia GI pipe suitable to mount on pole having top 70 mm A/F. Make : Surya/Bajaj/Jindal or equivalent
Supply and fixing of 1.5 m long Hot dip galvanised Double arm bracket (1.5 m long each) made up of 40 NB dia GI pipe suitable to mount on pole having top 70 mm A/F. Make : Surya/Bajaj/Jindal or equivalent
S&F on pole/wall/in panel/with fabrication of stand, sheet metal enclosure, Bus bar chamber consisting 4 pole 200 Amp 415 volts aluminium busbar suitable for connecting cable as a junction including connecting of cables with suitable size aluminium thimbles, cable glands including earth work and PCC complete all as specified and directed. Make- Havells,Legrand,L&T or Equivalant
Dismantling of cross-arms of M.S. channel or angle sections etc and ACSR conductor of any size and capacity including all connected items from over head lines complete all as specified and directed by Engineer-in-Charge.
Dismantling of PCC Poles any size complete all as specified and directed by Engineer-in-Charge.
S&F 45 W IP 66 LED security light luminaire comprising of epoxy powder Die-cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 100 W . The LED must be of 120 degree view angle, > 110 lumen/ watt, lumen maintenace > 70% at 50000 hrs, color temperature of 5000-6500K, >70 color rendering and LM 80 test compliance. The driver must be integral APFC and constant current type having THD<10% and power factor >0.95 with short circuit protection, open circuit protection, reverse polarity protection, high voltage protection, protection against 5 kV high surges and comply to IEC 60598-1, IEC 61000-3-2, IEC 61547 including The luminaire must have secondary optics with perfectly matched lens for better light control complete all as specified and directed by Engineer-in-Charge.
Supply and fixing automatic street light switch of rating 5 KW in three phase using nature sensor for automatic switching "ON/OFF" of steel lighting based on lux level of natural light along with 40 Amps Four pole contactor, MCB 40 Amps four pole with support terminals prewired with PVC insulated 25 sqmm multi strand copper wire enclosed/housed in pole wall mounted enclosure made of rust proof, shock proof, termite proof & dust proof FR grade moulded compound Junction Box complete all as specified and directed by Engineer-in-Charge. Make - Model-SWADEEP -02EC 8KW 3, of Nature switch/Kaktiya Energy systems Pvt Ltd/HEALER/BAJAJ or equivalent 1. Contactor :BCH/L&T/Schneider 2. MCB: Hager/Schneider/Legrand 3. Circuit wiring : Finolex/Polycab or equivalent
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out including taking out old brick or precast cable cover for reuse complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete 1:3:6 type C-1 using 20mm graded stoe aggregate for pole pedestal (PCC) incl necessary form work etc complete all as specified and directed by Engr-in-Charge.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with dry and clean locally available sand for underground cable 8cm before laying cable and 15 cm after laying cable and punned to 18 cm after laying of cable complete all as specified and directed by Engineer-in-Charge (Note: Pressed thickness shall be considered for payment purpose)
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement GI pipe 40 mm bore light grade for protection of cable laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge.
Supply and fix in replacement GI pipe 80 mm bore light grade for protection of cable laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge.
M&L for boring holes under road/pavement/hard standing or any other situation by manual means suitable for passing GI pipe 80 mm bore and making good both the ends complete all as specified and directed by Engineer-in-Charge.
M&L for Cable route indicators made out of 40 x 40 x 4 mm angle iron 1 m long and plate 100 x 150 x 6 mm welded only on one end and embossed as LT cable including PCC works for embedding complete all as specified and directed by Engineer-in-Charge. ---------------------------------------------------------------------------------------------------- Note : A sum of Rs. 204050.00 will be deducted on account of credit for taken down material. Please refer details on Srl Page No.25 (Schedule of Credit) of Tender documents.
Singla Electricals
M/S BUDHRAM BISHNOI
Gyan Chand Marothia Engineer Contractor And Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .