| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹34.1 L+₹3.7 L (12.1%)Rejected-Finance ROOM NO 214 GANESH MURTHY NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Being Other than Lowest Tenderer | |
| 3 | L3₹34.2 L+₹3.9 L (12.7%)Rejected-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Being Other than Lowest Tenderer | |
| 4 | L4₹35.4 L+₹5.0 L (16.5%)Rejected-Finance VILL SAHAJADPUR P O SAHAJADPUR DIST MURSHIDABAD PIN 742187 WEST BENGAL | SAHAJADPUR | MURSHIDABAD | WEST BENGAL | 742187 | L4 | Rejected-Finance Being Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | Bright Construction Co L1 | Pragathi Infrastructure Co. L2 | GANGAJAL L3 | A.R. ENTERPRISE L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster on brick / surfaces built in cement mortar including raking out joints, bading for key scrubbing down with water etc complete. | 150 | Sqm | 24 ₹3,600 Lowest | 50 ₹7,500 | 37 ₹5,550 | 40 ₹6,000 |
| 2.00 | Dismantling floor hearth or wall tiling including cement mortat bedding but not backing), removing serviceable tiles to store and rubbish off the premises. | 440 | Sqm | 14 ₹6,160 Lowest | 50 ₹22,000 | 38 ₹16,720 | 500 ₹2,20,000 |
| 3.00 | Taking down chowkats or frame with shutter ( without taking off shutter from frame) , n exc 1.5 sqm each complete all as specified. | 8 | Each | 100 ₹800 Lowest | 150 ₹1,200 | 185 ₹1,480 | 350 ₹2,800 |
| 4.00 | Taking down chowkats or frame with shutter ( without taking off shutter from frame) exc 1.5 sqm but n exc 4 Sqm each complete all as specified. | 2 | Each | 124 ₹248 Lowest | 200 ₹400 | 247 ₹494 | 400 ₹800 |
| 5.00 | Taking down 15mm bore, GI tubing and connections including cleaning for refixing or removal to store. | 60 | RM | 354 ₹21,240 | 10 ₹600 Lowest | 14 ₹840 | 40 ₹2,400 |
| 6.00 | All as per item No 5 above but 20 mm bore GI Pipe. | 25 | RM | 404 ₹10,100 | 15 ₹375 Lowest | 16 ₹400 | 45 ₹1,125 |
| 7.00 | Demolition of brick work or stone /boulder masonry built in cement mortar, including all quoins, arches, pillars, etc | 2.6 | Cum | 554 ₹1,440.4 | 400 ₹1,040 | 247 ₹642.2 Lowest | 500 ₹1,300 |
| 8.00 | M & L for Pre cast Cement concrete block masonary (type B1 1:2:4 20 mm graded aggregate) with solid blocks exc 10 cm in width and setting in CM (1:6) | 1.5 | Cum | 7,004 ₹10,506 Lowest | 9,000 ₹13,500 | 7,777 ₹11,665.5 | 13,000 ₹19,500 |
| 9.00 | M & L for brick work with sub class 'B' bricks (old Size) straight or curved on plan to any radius in half brick thick wall built in CM 1:4. | 10 | Sqm | 1,204 ₹12,040 | 700 ₹7,000 Lowest | 1,047 ₹10,470 | 1,800 ₹18,000 |
| 10.00 | S&F powder coated aluminium (minimum 25 micron thickness of coating) of various section as required for doors, window & partition/Ventilator etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement, handle, tower bolt for shutter, sealant complete all as specified and as directed | 380 | Kg | 474 ₹1,80,120 Lowest | 800 ₹3,04,000 | 647 ₹2,45,860 | 600 ₹2,28,000 |
Tender Value
₹41.4 L
EMD Value
₹82,753
Closing Date
17 Jan 2026, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL ANIL KUMAR S
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8265 ADDITION/ ALTERATION AND RENOVATION FOR WARD MASTER ROOM, BATH ROOMS, OT ROOM/ PHYSIOTHERAPY ROOM AND WAITING AREA OF BUILDING NO P-194 AT FLEET MEDICAL CENTRE AND ADDITION ALTERATION TO FACADE OF BUILDING NO. P-49 AT NAVAL DOCKYARD (MBI) UNDER
2025_MES_746343_1
8265/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹82,753
Yes
17 Feb 2026
27 Dec 2025
19 Jan 2026
7 Jan 2026
17 Jan 2026
10 Jan 2026
27 Dec 2025 - 7 Jan 2026
Taking down cement plaster on brick / surfaces built in cement mortar including raking out joints, bading for key scrubbing down with water etc complete.
Dismantling floor hearth or wall tiling including cement mortat bedding but not backing), removing serviceable tiles to store and rubbish off the premises.
Taking down chowkats or frame with shutter ( without taking off shutter from frame) , n exc 1.5 sqm each complete all as specified.
Taking down chowkats or frame with shutter ( without taking off shutter from frame) exc 1.5 sqm but n exc 4 Sqm each complete all as specified.
Taking down 15mm bore, GI tubing and connections including cleaning for refixing or removal to store.
All as per item No 5 above but 20 mm bore GI Pipe.
Demolition of brick work or stone /boulder masonry built in cement mortar, including all quoins, arches, pillars, etc
M & L for Pre cast Cement concrete block masonary (type B1 1:2:4 20 mm graded aggregate) with solid blocks exc 10 cm in width and setting in CM (1:6)
M & L for brick work with sub class 'B' bricks (old Size) straight or curved on plan to any radius in half brick thick wall built in CM 1:4.
S&F powder coated aluminium (minimum 25 micron thickness of coating) of various section as required for doors, window & partition/Ventilator etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement, handle, tower bolt for shutter, sealant complete all as specified and as directed
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge.
S&F 4mm thick backelite with decoratve choice laminated on both side complition as specified and as directed
S&F 4.8mm thick sheet glass froasted or obscured one side and glazing with oil putty or wooden beads in square area n.exc 0.5 Sqm in each pane complete all as specified and as directed
M&L 4.8 mm thick plain glass sheets ordinary quality in squares exc 0.5sqm each pane fixed with rubber beading for aluminium windows/doors etc all as specified and directed.
S&F 12mm thick Prelaminated medium density particle board, interior grade, prelaminated both side with decorative choice lamination fixed with screws to aluminium frame work complete all as specified and directed.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel stapple etc.
S & F 100 mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11.
S&F Aluminium anodised sliding door bolt 300m long, with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy .
S&F aluminium anodised Barrel tower bolts of extruded section, length of bolt 200mm.
S&F Extrude aluminium anodised alloy handles, fabricated type 150mm size.
S&f in repair for Floor door stopper of aluminium alloy body 140 mm long and tongue, anodised, with hard drawn steel spring, fixed in floor.
M & L for Non skid coloured ceramic tiles 7 to 8 mm thick ( square/ rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of the tiles with and including 15mm thick screed bed in CM 1:4 complete all as specified.
M & L for Coloured glazed ceramic tiles in vertical surface 450X300X7mm thick with and including 10 mm thick cm (1:4) backing coat and Triangular filliting at top of skirting, set and jointed in neat cement paste and pointed in coloured cement to match the shade of the tiles.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed
S&F 15 mm dia medium grade galvanized steel tubing with all fittings fixed to walls, ceilings or laid under floors all as specified and directed complete all as specified and as directed.
As per item No 25 above but 20mm dia medium GI Pipe
S&F Anodised aluminium snap grid size 605x605mm frame work for false ceiling all as specified.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L for false ceiling made out of 600x600x4 mm thick ( non asbestos fiber cement designer/coloured)ceiliing board / tiles deep panel (Make -Armstrong/Chanakya/Everest.
S&F in repairs for Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern
S&F in repairs vitreous china wash down water closet pan ( pedestal pattern) , white (excluding fixing bolts, flushing cistern and flush pipe) but with & including plastic seat cover of approved colour with flat bottom , and cover and mild steel chromium plated or aluminised hinging device etc complete
S&F in repairs PVC low level flushing cistern 10 Ltr capacity with complete fittings, flush pipe & float valves,handle incl brackets etc complete.
S & F in repairs white glazed earthen ware vitreous china wash hand basin of size 550x400 mm with and including CI brackets, with granite including 32mm bore brass CP waste coupling Inlet/ outlet PVC flexible pipe etc complete all as specified and directed by Engr-in-Charge.
S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repair counter top wash hand basin(Min size 480mm x 380mm x 140mm) incl chromium plated brass waste coupling and PVC waste pipe with bottle trap complete all as directed
S&F in repair Bib taps, cast copper alloy fancy type, chromium plated , screwed down, high pressure, screwed for iron pipe or for brass ferrule of 15mm dia.
S&F in repairs 15mm size Stop Valves fancy type chromium plated screwed down high pressure with crutch or butterfly handle handle screwed both ends
S&F in repair 15 mm dia fancy type pillar tap cast copper alloy with capston heads chromium plated screwed down high pressure with or without hot or cold with long screws shanks and fly nuts screwed for iron pipes all as specified and directed.
S&F in repairs fancy type cock suitable for counter top wash hand basin 15mm dia, screwed for iron pipe and fixed. Jaquar or equivalent
Rounding to edges of stone slabs on edge, such as in steps, cooking platform and making grooves for lining and other similar work complete all as specified and directed.
M&L for machine cut cudappa stone slab 20-25 mm thick fixed independently and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 50 mm dia and 350 mm long medium grade GI pipe spouts with wire gauge on inside mouth to be fixed before water proofing treatment of sunken slabs by cleaning RCC slab surface floors and walls by wire brush and rendering 6 mm thick in CM 1:4 mixed with integral WPC on uneven surface to make it even. Fill it water and check for dampness and seepage, all junctions points of side walls where CI/GI pipe are passing shall be sealed with epoxy mortar. Apply two coats of polymer modified cementious water proofing coating of minimum thickness of 1 mm each layer as per manufacturers instructions on floor & walls (upto 100 mm above FFL) and spray coarse sand on surface when the second layer is still sticky. Apply 20 mm thick plaster in CM 1:4 mixed with integral WPC of approved make on floors and walls including rounding of corners and junctions stoping towareds spouts. All pipes laid in sunken portions shall be covered with 50 mm thick PCC 1:3:6 all around after painting with anti corrosive black japan paint on GI/CI pipes. Test the water proofed area by filling water at least 72 hours and tested for leakage/seepage for the entire satisfaction of GE. After above said treatment apply two coats of hot blown bitumen @ 1.5 Kg /Sqm for each coat and laying 50 micron black polythene film in floors complete all as specified and directed. (Note : If leakage/Seepage occured after filling water at least 72 hours, the above said treatment will be re-done completely)
M&L for cement concrete 1:3:6 type C-2 , (20 mm graded stone agg) as in foundation filling and sunken floors etc all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar 100mm
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls
S&F 110 mm bore PVC (SWR) bends any radius all as specified and directed.
S&F 75 mmbore PVC (SWR) bends any radius all as specified and directed.
S&F for PVC (SWR) vent cowl 110mm
S&F for PVC (SWR) vent cowl 75mm
M&L in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm dia.
S&f for PVC connections 15mm size with PTMT nuts of length 600mm
S&F chromium plated, tubular towel rail 20mm dia, D type, 60 cm long between flange, fixed in repairs.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, fixed with self tapping screws as specified.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, valley gutter, ridge and fixed with crumple joint etc fixed with self tapping screws all as specified and directed.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finishing the surface fair and even and smooth without using extra cement all as specified and directed.
Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed (Water proofing compound to be measured and paid for separately).
M&L Plastering 5mm thick in CM 1:3 on concete surfaces as in ceiling finished even & smooth without using extra cement in ceiling complete all as specified and as directed .
M & L preparation of new plastered surfaces and applying three coat of white wash on ceiling
M&L for preparation of newly plastered surfaces of wall, applying two coats of oil emlusion distemper over a coat wall care putty of 3 mm thick and alkali primer.
M&L for preparation of newly plastered surfaces of wall, soffits, facia roof and applying two coats of weather proof acrylic based paint (100% acrylic) over one coat of cement based primer with necesssary scaffolding for high rise blds upto ixth floor complete all as specified and as directed
Complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down including applying applying one coats of oil bound distemper over a coat of primer complete all as specified and as directed .
M&L for preparation of old decorated surfaces of wall and applying one coat of oil emulsion distemper complete all as specified and as directed
M&L for preparation of old decorated surfaces of ceiling and applying one coat of oil emulsion distemper complete all as specified and as directed
Complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down with water etc and applying two coats of plastic emulsion paint on plastered/ puttied surfaces.
M&L for preparation of old painted wooden of any description over 10cm width or girth and applying one coat of synthetic enamel paint incl necessary scafolding complete all as specified and as directed
M&L of old decorated surfaces of walls soffits, facia roof and applying one coat of weather proof acrylic based paint (100% acrylic) with necessary scafolding for high rise bldgs upto G+9 floor. complete all as specified and as directed
S&Fof vitreous china urinal, half stall type complete including providing andfixing plugs bedding urinal against wall in cement mortar in 1:2 securing urinals to plugswith and including 60 mm brass screws, pointing around urinal back in cement , flush pipes, inlet ,outlet etc complete all as specified Fixed in repairs.
S&F 32mm dia PVC waste pipe for WHB and urinals fixed in repairs complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed by EIC.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. M.S.frame shall be covered with heat moulded design with colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed by EIC.
Demolition of stone slabs and tiles of any description laid bedded and pointed in any mortar or thickness in floors aprons etc complete all as specified.
Demolition of cement concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness(below or above ground level) complete all as specified .
M&L for 100mm thick Cement concrete type B-2, 1:2:4 (40 mm graded aggregate) as in floors finishing surface even and smooth without using extra cement.
M&L for sand filling under floors or in foundations including watering and consolidation and making to a true surface etc complete all as specified and directed.
M&L for machine pressed precast interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness,M-35 Grade and pointed with grey cement and pigment etc complete all as specified and directed.
M&L for chequered cement cocnrete tiles 20cmx20cmx25mm thick,set, jointed and pointed in neat cement slurry in floors with grey cement cement and pigment incl 15mm thick screed bed or bedding layer of CM 1:6 for laying floor finishes etc complete all as specified and directed.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps,jambs,pillars,window-cills,cooking platforms and like including pointing in white cement(1:2) using marble dust with admixture of pigment to match with shade of granite including grinding,polishing,rounding of edges and 20mm thick screed bed in CM 1:4 complete all as specified and directed.(Colour of granite will be decided by Engg-in-charge)
Cleaning & desilting of sewage lines upto 150mm bore and sludge chambers, gully traps of size and shape upto any depth by pumping out/removing liquid waste/sewage, plugging the ends pipes or diverting the flow into drains if necessary,removing silt,sludge etc, sprinkling bleaching powder on the site to avoid bad smell including all precautionary and safety measures,such as safety belts,lighting arrangements face mask etc and removing the same(silt,sludge&other waste material) in leak proof trucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and flushing the sewer lines with fresh water etc complete all as specified and directed by Engr-in-charge.(Note: length of sewage lines including chambers of manholes shall be measured separately under appropriate item).
M&L cleaning the existing drainage/culvert including removing cover slab,spoils,soils,vegetation,silt etc and refixing cover slab including making good and removing waste materials outside MD Land complete all as directed by EIC.
M&L for brickwork with subclass 'B' bricks,straight or curved on plan exc 6m mean radius built in CM 1:4 etc including all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to I.S. 1161-1979 grade st 240 etc complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel (ordinary tint) over one coat of red oxide primer etc complete all as specified and directed.
Dismantling wall and ceiling boards ( fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets etc complete all as specified.
S&F in repairs Hangers 6mm dia G.I. (upto 1200mm length) adjusting level fixed to slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60mm long and expansion hold fastners 12.5mm dia. 40mm long complete all as specified.
S&F Anodised aluminum snap grid framework of size 605 x 605mm for false ceiling all as specified.
M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/inserted to Aluminum framework with screws all as specified.
Removing bldg material exc. 1.50 km but n exc. 5 km and depositing where directed
M & L for concealed point wiring with FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm size 1100 volts grade drawn through and including non metalic rigid PVC conduit not less than 25mm width with all accessories fixed on wall including FRLS PVC insulated, unsheathed multistranded copper onductor cable of size 1.5 sqmm as earth continuty conductor connecting to common earth dolly and PVC moulded box ISI marked for having the switches, switch sockets regulator etc complete all as specified for following:-
One light point controlled by one switch
One ceiling fan/wall fan/exhaust fan point controlled by one switch
One 5A flush type switch socket point on same board
One 5 Amps switch socket combination on independent board
Supply and fix switch modular type 1 way 6 Amps 1 module 240 volts flush type
Supply and fix modular socket 6 Amps 2/3 pin 240 volts Ac combined 2 module all as specified and directed by Engr-in-Charge.
Supply and fix switch modular type 1 way 16 Amps 1 module 240 volts flush type
Supply and fix modular socket 16 Amps 2/3 pin 240 volts Ac combined 2 module all as specified and directed by Engr-in-Charge.
Supply and fix ceiling rose surface bakelite three terminal of size 60x50 mm,240 Volts AC complete
S&F in repairs for modular fan step regulator, 35/60W - 2 modul suitable for BLDC fans all assspecified and directed. Make: Anchor/Roma plus/Legrand
M & L for point wiring in repair with FRLS PVC insulated unsheathed multi stranded copper conductor cable of 2.5 sqmm size 1100 volts grade drawn through and including non metalic rigid PVC casing and caping not less than 25mm width with all accessories fixed on wall including FRLS PVC insulated, unsheathed multistranded copper onductor cable of size 2.5 sqmm as earth continuty conductor connecting to common earth dolly and PVC moulded box ISI marked for having the switches, switch sockets regulator etc complete all as specified for following:-
One 15A flush type switch socket point on independent board
Supply and fixing in replacement of walll/surface mounted 20W LED batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG/wipro/C&S cat No LTTB4F20WLEDEW BATTEN/Bajaj/Havells/Philips
S&F in repair LED recess mounted type fitting 36W 2'x2' CRCA LED Slim panel with recess mounting, powder coated white CRCA full glow LED panel including control gear and lamp complete all as directed and specified by Engr-in-Charge.Make : shakti cat part No. SZSBLMX040 or equivalent
M&L for submain wiring with 2 runs of 4 sqmm and 1 run of 4 sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable with proper colour coding drawn through and including non metalic PVC casing & caping not less than 25mm width ISI marked with all accessories like PVC elbow, PVC Tee etc fixed on wall complete including connecting up all as specified and directed.
M&L in repair for submain wiring with 2 runs of 6 sqmm and 1 run of 6 sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable with proper colour coding drawn through and including non metalic PVC casing & caping not less than 25mm width ISI marked with all accessories like PVC elbow, PVC Tee etc fixed on wall complete including connecting up all as specified and directed.
S & F in replacement of distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 8 way, 440 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s etc complete all as directed. Make - Legrand or Equivalent in siemens/GE
S&F in replacement of steel sheet enclosure double door type IP54 IK09 protection DB SPN 12 way, 240 volts AC factory made, suitable for housing MCB SPN along with 200 Amps copper bus bar complete all as specified and directed
S & F in replacement of MCB SP 6 - 32 Amps, 10 KA Rupturing capacity complete all as specified and directed.
S & F MCB SPN 40-63 Amps, 10 KA Rupturing capacity complete all as specified and directed.
S & F in replacement of MCCB 4P 100 Amps,16KA,thermal magnetic,415volts complete all as specified and directed. Make : Legrand cat No 420015/Seimens/GE
Supply , fixing, testing of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( averaSchneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl all as specified . Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
Supply and fixing of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
S&F GI tubing light grade 40mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed. Make : Jindal/Tata/Surya Prakash
Material and labour for cutting road/hard standing for laying of cable and making good the same to match the existing surface complete all as directed by Engr in charge.
M & L for replacement of for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as specified and directed by Engr-in-Charge.
Supply and fixing of heavy duty exhaust fan 300mm sweep, single phase with louvers complete all as specified and directed.
Supply and fix remote operated BLDC ceiling fan 1200 mm sweep, energy saving, five star rating, ISI marked of approved colour white/brown/ivory complete with down rod, three core flexible wire etc from ceiling rose to fan complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_835730.xls
BOQ • 21.48 MB
8265TENDERDOCUMENTS1.pdf
Tender Documents • 1.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .