Loading…
Loading…
Tender Value
₹49.0 Cr
EMD Value
₹49.0 L
Closing Date
13 Aug 2026, 11:00 am4d left
Construction, Repair, Renovation and Development of various buildings, roads and drains including Electrical and Mechanical work in Maharaja Sriram Chandra Bhanja Deo University (MSCBU), Sriram Chandra Vihar, Takatpur, Baripada, Mayurbhanj under PM USHA
NBCC/CPG/MSCBU/Baripada/2026/584
NBCC/CPG/MSCBU/Baripada/2026/584
Open Tender-Domestic
Civil Works General
Mayurbhanj, Odisha
₹59,000
₹49.0 L
23 Jul 2026
23 Jul 2026
13 Aug 2026
13 Aug 2026
Name of Work: Construction, Repair/Renovation & Development of various buildings, roads and drains
including Electrical and Mechanical work in Maharaja Sriram Chandra Bhanja Deo University (MSCBU), Sriram
Chandra Vihar, Takatpur, Baripada, Mayurbhanj under PM USHA
Sl. No. Description of Item Schedule Amount Total Amount
Sl. No. Description of Item Schedule Amount Total Amount
1 Innovation & Incubation Centre Building
II Plumbing Works 28,56,279.40 - 28,56,279.40
IV Fire fighting Works - 6,46,153.84 6,46,153.84
2 Indigenous Knowledge & Language Building
III Internal Road 6,83,132.47 - 6,83,132.47
IV Plumbing Works 34,20,513.60 - 34,20,513.60
VI Fire Fighting Works - 7,12,003.74 7,12,003.74
3 Central Instrumentation Facility Building
II Plumbing Works 48,57,370.18 - 48,57,370.18
IV Firefighting Works - 7,96,614.46 7,96,614.46
V Air Conditioner Works - 11,79,948.08 11,79,948.08
4 Academic Building (Science Block)
II External Development 47,98,746.67 14,35,824.00 62,34,570.67
V Firefighting Works - 84,34,966.86 84,34,966.86
VI Air Conditioner Works - 1,17,96,035.20 1,17,96,035.20
VII Audio Visual System 88,49,999.29 - 88,49,999.29
5 150 SEATED BOY'S HOSTEL
II Plumbing Works 74,18,978.15 - 74,18,978.15
IV Firefighting Works - 16,69,609.14 16,69,609.14
Digitally signed by DIWAKAR
6 150 SEATED GIRL'S HOSTEL
II Plumbing Works 74,18,978.15 - 74,18,978.15
IV Firefighting Works - 16,69,609.14 16,69,609.14
7 REPAIRING AND RENOVATION
III Electrical Works 45,23,083.96 - 45,23,083.96
8 FURNITURE WORKS
B Total BoQ Amount 48,98,40,602.29
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Civil Works 0.00 0.00
Earth work in excavation of foundation trenches in hard soil
including dressing of sides and levelling the bed up to the required
depth and depositing the excavated materials away from the work
1 1 site within 50m initial lead & 1.5m initial lifts with sundries & T&P Cum 252.79 326.74 82,597.11
required for the work complete including cost of all labour,labour
cess,T&P,sundries etc. as directed by the Engineer in charge.
Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
2 2 ramming & watering with all leads & lifts including cost of all Cum 169.84 181.48 30,823.24 0.00
labour,T&P completed as directed by the Engineer-in-charge.
Supplying and filling in foundation and plinth with good quality river
sand including watering, ramming with cost, conveyances,
3 3 royalties of all materials and cost of all labour with T&P required Cum 18.50 1595.71 29,520.71 0.00
for the work etc. complete as per specification & direction of
Engineer-in-charge
Providing & applying of pre constructional anti-termite treatment
by drilling 12mm dia holes at distance of 30cm @ junction of wall
& floor about 300mm apart deep enough to reach the soil below &
chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr
water) pumped these holes to soak the soil @ 1 ltr solution of
each hole as per manufactures specification & the holes should
be pluged the filling materials including cost of all materials,
labour,conveyance, T&P , all taxes and hire charges of
machinaries as per direction of Engineer-in-charge.
Cement concrete of proportion (1:3:6) in foundation and floors
using 4cm size clean hard black crusher broken granite stone
metal of approved quality and from approved quarry including
hoisting, lowering and laying concrete in layers not exceeding 15
5 5 cm. (6") thick to the required level ramming, watering, curing etc. Cum 46.28 8812.12 4,07,825.01 0.00
complete including cost, conveyance, royalties of all materials with
all labour and T&P required for the work etc. complete in all
respect and as per the direction of the Engineer-in-charge.
Plain cement concrete (1:2:4) using 12mm size black hard
crusher broken granite chips of approved quality from approved
quarry including hoisting, lowering and laying concrete in layers,
watering, curing etc. complete including cost, conveyance,
royalties of all materials with labour,labour cess and T&P etc.
required for the work complete as per the direction of the Engineer-
Fly Ash. brick masonry of size 25 cm. x 12 cm. x 8 cm. having
crushing strength not less than 75 kg. Per Sqr. Cm. in cement
mortar of mix (1:6) with approved grade cement and screened &
washed sand for mortar after immersing the bricks for 6 (Six)
hours in water before use in Superstructure including splays
cutting, circular moulding, corbelling, chamfering and similar such
type of works, watering and curing etc. including cost,
conveyance, loading, unloading, royalties and taxes of all
materials, cost of all labour, scaffolding, sundries, T&P required
for the works etc. complete in all respect as directed by the
Engineer-in-charge
Fly Ash brick masonry in cement mortar (1:4) in super structure
using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing
strength of not less than 75 kg./sqcm with dimensional tolerance ±
2% including splays cutting circular moulding chamfering and
corbelling and similar such type of works with all necessary
11 8 projections watering and curing after immersing the bricks in water 0.00 0.00
at least for six hours before use including cost, conveyance,
royalties and taxes of all materials with all labour,labour cess and
T & P required for the work complete in all respect as per direction
of Engineer-in-Charge.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
15 A Ground floor 0.00 0.00
17 b B) Column upto plinth Cum 4.32 20715.61 89,491.43 0.00
19 d c) Column up to ceiling level Cum 9.14 20715.61 1,89,340.66 0.00
25 B 1st floor 0.00
26 a a) Column above plinth :- Cum 9.14 23135.08 2,11,454.63 0.00
32 C Terrace floor 0.00 0.00
33 a a) Column up to ceiling level Cum 3.68 26031.15 95,794.65
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor
steel of primary steel producers such as (grade Fe-500D) etc.
including bending, binding, welding and jointing if necessary and
tying the grills and placing in position as required for R.C.C. Work
and for providing fan hooks as required, hoisting, lowering, laying
including cost, conveyances of M.S. Rod or tor steel and binding
wires of 18 to 20 gauge and labour required for the work for
bending, binding and tying the grills in all floors with labour cess
etc. (payment will be made on standard weight of B.I.S. for M.S.
Rods or tor steel only) etc. complete as per specification &
direction of Engineer-in-charge.
Providing 12 mm thick cement plaster with cement mortar of mix
(1:6) with screened and washed sharp sand for mortar and
finished smooth to the rough surface of walls in all heights after
racking out joints including watering and curing, rounding of
41 11 corners, providing grooves where ever necessary with cost, 0.00 0.00
conveyance, royalties of all materials with cost of all labour,labour
cess, T&P, and scaffolding required for the work etc. complete in
all respect as directed by the Engineer in charge.
Providing 16 mm thick cement plaster with cement mortar of mix
(1:6) with screened and washed sharp sand for mortar and
finished smooth to the rough surface of walls in all heights after
racking out joints including watering and curing, rounding of
45 12 corners, providing grooves where ever necessary with cost, 0.00 0.00
conveyance, royalties of all materials with cost of all labour,labour
cess, T&P, and scaffolding required for the work etc. complete in
all respect as directed by the Engineer in charge.
48 c Terrace Floor Sqm 35.66 355.42 12,674.13
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Providing 6 mm thick cement plaster with cement mortar of mix
(1:4) with screened and washed sharp sand for mortar and
finished smooth to R.C.C. work after closed deep chipping & slurry
treatment including watering and curing, rounding of corners,
49 13 providing grooves where ever necessary with cost, conveyance, 0.00 0.00
royalties of all materials with cost of all labour,labour cess, T&P,
and scaffolding required for the work etc. complete in all respect
as directed by the Engineer in charge.
Fixing granite tiles of approved dimension area above 0.4 sqm
(20mm thick) in floor, treads of steps and landing on 20mm thick
bed of cement mortar (1:4) jointed with neat cement slurry mixed
53 14 with pigment to match the shades of the tiles including rubbing 0.00 0.00
and polishing etc. complete with cost, conveyance, royalties and
taxes of all materials complete in all respects as per direction of
Engineer-in-Charge.
Fixing granite tiles of approved dimension area above 0.1 up to
0.4 sqm (10mm thick) in Dados, treads of steps and landing on
12mm thick cement mortar (1:3) jointed with neat cement slurry
mixed with pigment to match the shades of the tiles including
rubbing and polishing etc. complete with cost, conveyance,
royalties and taxes of all materials complete in all respects as per
direction of Engineer-in-Charge.
Providing full body matt finish vitrified tile flooring using vitrified
tiles having thickness of min 10mm conforming to IS 13755 of
1200x600 (shade to be decided as per Ama Hospital scheme)
(homogeneous) of premium quality (JOHNSON / SOMANY/
KAJARIA/ RAK) in floors, treads on steps and landings on 20mm
thick bed of cement mortar of mix (1:4) laid in proper slope and
gradient with screened and washed sharp sand for mortar and
fixing with neat white cement slurry,grouting the joints with neat
white cement slurry mixed with required quantities of pigments of
approved make to match the shades of the vitrified tile if required ,
watering and curing for 21 days, including cost, conveyance,
loading, unloading, royalties and taxes of all materials, cost of all
labour,Labour cess , sundries, T&P required for the work,
complete in all respect as per specification and direction of
Engineer-in-charge.
Providing, fitting, fixing vitrified tiles of premium grade having
thickness 8mm to 10mm confirming to IS 13756 of size 600mm x
600mm Plain (Ivory) of approved make (JOHNSON / SOMANY/
KAJARIA/ RAK) as directed by Engineer-in-charge in dados
skirting and risers of steps on 12mm thick cement plaster (1:3)
jointed with neat cement slurry mixed with pigment to match the
shades of the tiles including rubbing and polishing etc. complete
with cost, conveyance, royalties of all materials all labour,labour
cess complete in all respects.
Supplying, fitting & fixing of Chequered tiles in floors of approved
make laid on 20 mm thick cement mortar (1:4) (1 cement : 4
65 18 course sand) and filling joints with slurry including cost of all
materials, labour T&P etc required for the work all complete as per
direction of the Engineer-in-charge
66 a Ground floor Sqm 15.84 754.61 11,953.02
Supplying, fitting & fixing of 8-10 mm thick & size of 600x600
mm Anti-skid vertified floor tile of with veilcraft (VC/FT ) shield(
Scratch free/stain free) with water absorption limit between 0.08%
to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 20
mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling 0.00 0.00
joints with white cement of approved quality including cost of all
materials, labour T&P etc. required for the work all complete as per
direction of the Engineer-in-charge (for New Work only )
Supplying, fitting & fixing of 600mm x 300mm Ceramic wall tiles
having thickness 6.5mm to 7.0 mm confirming to IS 13753 in
dadoes, skirting and risers of steps laid on 12 mm thick cement
mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed
70 20 with pigment to match the shades of the tiles etc. complete 0.00 0.00
including cost of all materials, labour T&P etc. required for the
work all complete as per direction of the Engineer-in-charge
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Providing and fixing seasoned sal wood work in frames at any
locations including doors, windows,cupboard, clerestory and other
frames fixing in position including cost of hinges, M.S. flat (30mm
73 21 x 6mm) hold fasts lugs or dash fasteners of required dia and
length as per drawing / specification, at all floors and all heights.
Supplying, fitting and fixing of 32mm thick flush door shutter with
approved quality of 30mm thick BWR block board pasted with
1mm thick sunmica on both side of approved design and quality
76 22 including cost of all door fittings and fixtures etc. complete in all 0.00
respect as per the direction of the Engineer-in-Charge.
Factory made single leaf rigid FRP(alternately called GRP)
sandwich composite door shutter of 32mm thick laminated with
two GRP skins with wood grain finish fabricated using UV-
stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass
Chopped Strand Mat (CSM) impregnated with orthopthalic
palyester resin. The thickness of the skins shall not be less than
3.00mm Expanded Polystyrone(EPS) structural foam panel of
29mm thickness and a density of 20kg/cu.mtr shall be used as
core material. Wooden reinforcements made of seasoned sal
wood block of cross section not less than 28mmx32mm and also
necessary sal wood reinforcements for fitting the metal fittings
such as tower bolts, aldrops, handles etc shall be provided. A
structural adhesive compatible with (EPS) foam shall be used for
bending the core material, the sal wood reiforcements and the
skins. The material and process for manufacturing the door
shutters shall conform to RV-TIFAC composites Design Centre's
standards and specifications and the door shutters tested in
conformation to IS: 4020-1998. The finish of door shutter will be
plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood
or any other colour using high quality pigments. Three heavy
whight mild steel butt hinges type-I(ISI marked) size 100mm are to
be fitted on one side of shutter with FRP frame of size 45x90mm.
Supplying and fixing of Powder coated 50-60 microns approved
colour of Aluminium 40mm Casement series Door Unit with
suitable aluminium extrude profiles. the system is designed to
accommodate 12mm clear toughened glass of make-Saint
gobain/AIS/Gardian/modi. the rate quoted inclusive of hardwares
like antilift,roller, Espag lock cum handle,epdm gaskets,T mullion
,Fly Mullion ,bottom adopter ,mid transom ,glazing clip for 12 mm
glass felt along with all accessories etc complete. the gap
82 24 between the wall and window will be filled with silicon weather 0.00
sealant in the outer side. Casement Door Outer frame - 40mm x
45.3mm Series x 1.4mm thickness, Fly mullion - 44 x 60 mm x
1.4mm thickness, T Mullion 40 x 78.4mm x 1.4mm thickness,
Transom - 40.28 x 125.8 x 1.75 mm thickness, Bottom adopter -
34.6 x 26 x 1.5mm thickness, including cost of all materials, all
labour, sundries, T&P etc. complete in all respect as per direction
of Engineer-in-Charge.
Supplying and installing UPVC- 3 track 3 shutter sliding windows
with Outer dimension - 104 x 49 sash dimension of 61mm x 39mm
for windows with corners fusion welded, fully reinforced with
Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with
5mm reflective toughened glass . The windows must be installed
complete with all kinds of ironmongery (including EPDM
gaskets,bridging wedges and glass packers) and with suitable
water draining system. Application of Silicon sealant from Inside /
Outside of Dowcorning / GE or equivalent including cost of all
materials, all labour, sundries, T&P etc. complete in all respect as
per approved drawing & direction of Engineer-in-Charge.
87 c Terrace Floor Sqm 2.97 11389.03 33,825.42
Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S.
gates, garage door, collapsible gates with top and bottom rails,
steel windows, critical frames for windows, stair case and parapet
railing made out of M.S Square bar/ flat including stair case hand
railing with 40mm. dia G.I.pipe etc. including painting two coats
over a coat of redoxide primer as per approved drawing and
design with cost of all materials & labour, labour cess, T&P,
sundries etc. complete in all respect as per specification &
direction of the Engineer-in-Charge.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
91 c Terrace Floor Kg 121.50 75.99 9,233.03
Priming one coat with wall cement primer (water bound) to make
an even finished surface in all floors and heights to wall surface of
approved make and shade including sand papering, applying
92 27 putty wherever necessary & cost of scaffolding, staging charges
with cost, conveyance, cost of all labour,labour cess T&P etc.
complete as per the direction of the Engineer-in-charge.
95 c Terrace Floor Sqm 160.38 102.19 16,388.91
Wall painting two coats with Antifungal weather coat paint (1st
quality) exterior grade of approved make & approved shade over
a coat of primer to make an even finished surface in all floors and
heights with all scaffolding and staging charges including cost,
conveyance, cost of all labours, T & P, sundries etc. as required
for the work complete in all respect as per the direction of the
Engineer-in-Charge.
99 c Terrace Floor Sqm 106.57 128.03 13,644.16
Finishing plastered surfaces of walls with cement based wall putty
(Water based) of approved make duly approved by Engineer-in-
Charge) and finishing the surface smooth and even by sand
papering to receive painting in walls, at all heights with staging
wherever necessary with cost, conveyance, cost of all
labour,labourcess, all T&P etc. required for the work complete in
all respect as per the direction of the Engineer-in-charge.
103 c Terrace Floor Sqm 160.38 100.54 16,123.96
Painting two coats with plastic emulsion paint with a approved
quality primer to make an even finished surface in all floors and
heights to wall surface of approved make and shade including
104 30 sand papering, applying putty wherever necessary & cost of
scaffolding, staging charges with cost, conveyance, cost of all
labour,labour cess, T&P etc. complete as per the direction of the
Engineer-in-charge.
107 c Terrace Floor Sqm 53.81 133.81 7,200.42
Painting two coat with approved synthetic enamel paint to new
wood work over a coat of Red oxide primer including cost,
108 31 conveyances, royalties, taxes of all materials and cost of all labour
with T&P required for the work etc. complete as per specification &
direction of Engineer in charge.
Painting two coat with approved synthetic enamel paint to new
iron work over a coat of Red oxide primer including cost,
111 32 conveyances, royalties, taxes of all materials and cost of all labour
with T&P required for the work etc. complete as per specification &
direction of Engineer in charge.
Supplying, fitting and fixing of Stainless steel of 304 grade in hand
railing using 50mm dia of 2mm thick circular pipe with Balustrade
of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless
square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in
stair case as per approved design and specification, buffing,
polishing etc with cost, conveyance, cost of all labour,labour cess,
T&P etc. required for the work complete in all respect as per
direction of the Engineer-in-charge.
Providing 2.5cm thick Grading Concrete over roof slab with
cement concrete (1:2:2) using 6mm size black hard granite
crusher broken chips and screened & washed sharp sand for
mortar and finished smooth to the rough surface of slab including
118 34 watering and curing with cost, conveyance, royalties of all
materials with cost of all labour, labour cess and T&P required for
the work etc. complete in all respect as directed by the Engineer in
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supply and Installation of System comprises of Semi unitized
extruded aluminum Structural Glazing wall panels comprising of
extruded Vertical Aluminium mullions and Horizontal transoms
(JINDAL/HINDALCO/EQUEVALENT ) with super Durable Powder
Coating finish of minimum 60 Microns confirming standards to
withstand wind pressure. The mullions and transoms are installed
on locations as indicated in the architectural drawings. The
framing members provide no structural support for the building
and the Structural Glazing wall is deemed to be a lightweight
façade which is intended to separate the external from the internal
120 35 of the building and provides natural light into the building. The
curtain wall system is designed to have internal drainage system
within the extruded sections with 6MM Blue toughened glass.
Gaskets are employed as water barrier between the aluminum
gridwork and the glazed sashframe, which are fully drained in the
event of leakage past the primary seal. The external grooves are
covered with application of backer rod with weather sealant of
approved make as indicated in the concept drawing. Fabricating
and supplying Mild Steel ( HDG coated ) Brackets to
accommodate 3 Dimensional movement for achieving perfect
verticality and proper fixing of structural glazing system with the
Supply and Installation of 14 mm GRG Tiles steppe edge ceiling
tile of size 595 x 595 x 14 mm on the edge & 7 mm in the center
having all edges encapsulated with chemical treated paint &
having densified tegular edge ,weight 5 kg/m2 having random
circular semi perforated in dual diameter / Random fissure semi
perforated in variable length which is suspended by using 0.3 mm
thick and 15 mm wide pre coated metal T 15 grid system. The
technical parameters are as follows : Core - GRG Silicate, Fire –
Class 1 & P , Acoustics – NRC 0.5,Climate (degree C, RH) – 50,
99, STC - 30, Termite resistance ,Light reflectance – 85 %,Green
(RC %) – 25, Hygiene (VoC, Clean room) – Low, , Load capacity
(Kg) - Antisag. The T 15 Grid system of 600 x 600 mm module
shall include wall angle(WA 15) with unequal flanges of size 14 x
20 x 3000 mm wide, length 3000 mm, 0.43 mm thick fixed along
the perimeter of wall with the help of nylon sleeves and suitable
fasteners at 300 mm centers. Then suspend the Main T15 (MT15
W36) having flange width 15 mm /24 mm , height 32/38 mm and
length 3600 mm thickness 0.30 mm from the soffit with help of
soffit cleat and wire at 1200 mm c/c. Cross T15 (CT15 W12) with
flange width 15 mm, height 32 mm and length 1200 mm is then
interlocked into the pre-cut slots in the Main T15 at 600 mm
centers in the direction perpendicular to the Main T15. Finally,
Cross T15 (CT15 W06) having flange width 15 mm, height 32 mm
and length 600 mm are then interlocked into the pre cut slots in
the 1200 mm Cross T15 at 1200 mm centers and in direction
parallel to the Main T15. GRG Tile of size 595 x 595 x 14 mm thick
shall be placed into the grid size of 600 x 600 mm. Ensure arrow
marks behind panels are oriented in one direction to achieve
uniform shade. Test certificate will be submitted after procurement
Waterproofing application:- Providing and application of two
component polymer modified flexible cementitious waterproofing
coating at a thickness of 1.5 -2.5 mm The membrane should have
Elongation equal or more than: 30%
Crack Bridging ability : Up to 1 mm
Adhesive strength: 1.0 N/mm² @ 28d
126 37 Tensile elongation: 60% @ 20°C 0.00
Shore A Hardness >85 (between 3 - 7 days)
etc. as per direction of E.I.C (For longer span, in terrace panel of
4m*4m should be done by groove cutting, and filling with PU
128 Sub-Total of Civil Works 87,67,576.43 23,78,723.70
129 Plumbing Works
130 INTERNAL PH WORK-SUPPLY & DRAINAGE PIPING & FITTINGS
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying, installing, fixing, jointing, testing and commissioning of
approved make. Chlorinated Polyvinyl Chloride pipes (CPVC)
SDR.11 pipes confirming to ASTM standards with necessary
fittings for inetrnal toilet water supply upto 50 dia , and above
50mm dia pipe schedule 80 with fitting shall be schedule 80
ASTM IPS. The fittings and specials such as tees,
elbows,couplers, bends, enlargers etc.,m with CPVC brass
threaded combination / transition specials such as male adapters
brass threaded female adapters, brass FPT Tee, Brass FPT
elbow etc., where connection with metal is to be made including
necessary drilling holes, chasing walls and making the same good
in cement martor 1:1 restore the same original condition neately
as directed by the Engineer in-charge. Joints to be made with
CPVC solvent cement up to 50mm dia as per ASTM D-2846 and
above 50mm dia primer P-70, and solvent confirming to ASTM F-
4931 / 724 All exposed pipe shall be painted with latex paint. (for
shafts, basement ceiling ringmain Terrace & PRM).The rate shall
include necessary GI supports, GI grip bolts, angle brackets,
hangers, supports as with suitable GI U-clamps, bolts, nuts and
washers etc., The clamps shall be painted with two coats of
enamel (approved) paint over a coat of primer etc., complete
Providing all materials, labour, T&P for fitting & fixing of following
CPVC Ball Valves(CTS Sockets) confirming to IS-15778 with ISI
mark as per ASTM D-2846 in all floor & fixing with the pipes after
cutting the pipes to required shape & size including wastage etc.
of following nominal diameter, all complete including testing the
139 2 joints with required water pressure.The cost inclusive of 0.00 0.00
transportation scaffolding etc. all complete as per specification
excluding GST and direction of Engineer-in-charge
140 a 25 mm dia CPVC ball valve Each 10.000 637.78 6,377.76 0.00
141 b 32 mm dia CPVC ball valve Each 5.000 816.78 4,083.92 0.00
Supplying, installing, testing and commissioning butterfly valves
with standard lever confirming to IS 13039 with necessary
142 3 connecting fittings like flanges ,nuts and bolts etc., complete. 65 Each 4,796.35 0.00
143 B DRAINAGE PIPE
Supplying all materials, labour, T&P and cutting holes through
existing brick work including making good the damages in cement
mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and
fittings etc. all complete as per P.H. specification and direction of
Engineer-in-charge. 250 mm thick wall
Supplying all materials, labour, T&P and cutting hole in R.C.C
floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C
pipes and fittings etc and repairing the holes after insertion of
pipes etc with cement concrete (1:2:4 ) including finishing
complete so as to make it leak proof as per direction of the
Engineer-in-charge. Each 22.000 269.87
Supplying, fitting and Outing of PVC pipes as per
(IS:4985-2000) with heavy duty solvent cement (manufacture's
made) joint for basin and sink waste Class-3 (6 kg/sqcm) with
necessary fittings like bends, tees, reducers, sockets etc. &
146 3 specials viz. MS clamp as per design, screws with washer
includuing cutting holes in floor & walls & making good the
same, cutting chases & filling the same with PCC (1:2:4) & then
cement morter (1:6).
Supplying, fixing and testing PVC soil, waste, Rain and vent pipes
(SWR) supreme confirming to IS13592 : 2013, type B with rubber
ring/Solvent (confirming toIS5382) joint inclusive of allnecessary
specials like bends, tees,offsets, door bends, junctions, cowls,
etc.,laid underfloor/ fixed on walls,and in pipe shafts etc.,
complete.The rate shall include necessary GI supports, GI grip
bolts, angle brackets, hangers, supports as with suitable GI U-
clamps, bolts, nuts and washers etc., The clamps shall be painted
with two coats of enamel (approved) paint over a coat of primer
etc., complete.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Providing ,fixing , testing and commissioning of approved make
152 5 PVC vent cowl with necessary accessories etc., complete. 5.000 180.07 900.34
SANITARY FIXTURES.
Supplying all materials, labour, T&P and fixing the following
vitreous china Wash Down Water Closet (European type W.C.
pan) of Hindware/Jaquar/Parryware with integral 'p' or 's' trap to
the floor with wooden plug and chromium plated pedestal screws
including jointing the trap with soil pipe in cement mortar (1:1)
fixing plastic seat and cover for wash down water closet with
chromium plated brass hinges and rubber buffers including
polishing etc all complete as per specification and direction of the
Engineer-In-Charge. (EWC with Wall Hung Cistern, Drainage L
Bend Pipe, Gasket and Installation Kit with PP normal close seat
cover, Hinges, Fixing Accesso
Supplying all materials, labour, T&P and fixing Health Faucet of
Hindware/Jaquar/Parryware complete with Chromium plated brass
155 2 brackets fixed to wooden plugs with Chromium plated brass screws 31,300.68 0.00
as per specification and direction of the Engineer-In-Charge.
Supplying all materials, labour, T&P and fixing standard sized Two
way Bib cock of Hindware/Jaquar/Parryware of approved make
etc complete including cutting the wall and making good the
156 3 damages, including cost of all materials complete as per PH 32,992.80
specification complete as per direction of Er-in-charge. 15mm dia
CP Two way bib cock with Flange.
Supplying all materials, labour, T&P and fixing standard sized
Long way body bib cock of Hindware/Jaquar/Parryware of
approved make etc complete including cutting the wall and making
157 4 good the damages, including cost of all materials complete as per 4,630.08
PH specification complete as per direction of Er-in-charge. 15mm
dia CP Two way bib cock with Flange.
Supplying all materials, labour, T&P and fixing standard sized
concealed stop cock of Hindware/Jaquar/Parryware of approved
make etc complete including cutting the wall and making good the
158 5 damages, including cost of all materials complete as per PH 3,396.75
specification complete as per direction of Er-in-charge. 15mm dia
CP Two way bib cock with Flange.
Supplying all materials, labour, T&P and fixing standard sized
Chromium Plated brass Towel Rail complete with Chromium
159 6 Plated brass brackets fixed to wooden plugs with Chromium
Plated brass screws as per specification and direction of the
Engineer in charge
161 b C.P. Soap Dish holder. Each 12.000 1439.84 17,278.03
Supplying all materials, labour, T&P and fixing standard sized
162 7 Robe Hook of Hindware/Jaquar/Parryware complete with all as 11,095.37
per specification and direction of the Engineer in charge. Each 12.000 924.61
Supplying all materials, labour T&P and fixing of Under Counter
wash basins of Hindware/Jaquar/Parryware of approved make in
all floor of approved quality including cutting the walls & floor and
163 8 making good the damags with cement concrete e.t.c including all 75,076.32
tsxes,duties,transportation e.t.c. All complete as per specification
and direction of the Engineer-In-Charge.
Supplying all materials, labour T&P and fixing of Waste coupling
164 9 32 mm size Half thread with 80mm height (Half Threaded) 8,745.22
Supplying all materials, labour, T&P and fixing mirror of superior
glass mounted on 6mm thick A.C.sheet or plywood sheet and
fixed to wooden plugs with CP screws and washers complete as
per specification and direction of the Engineer-in-charge.
600mmx450mm size B.E.mirror (Alpina/Golden fish/Belgion)
Supplying all materials, labour, T&P and fixing standard sized
pillar cock of Hindware/Jaquar/Parryware of approved make etc
complete including cutting the wall and making good the
damages, including cost of all materials complete as per PH
specification and direction of Engineering-in-charge. 15mm dia fus
Jaquar,Cat No- PRS-031 Each 12.000 2197.16
Supplying all materials, labour, T&P and fixing standard sized
Chromium Plated soap dispenser Hindware/Jaquar/Parryware
complete with Chromium Plated brass brackets fixed to wooden
plugs with Chromium Plated brass screws as per specification
and direction of the Engineer in charge. soap dispenser jaquar
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying all materials, labour, T&P and fixing standard sized
15mm dia angular Stop cock of Hindware/Jaquar/Parryware of
approved make etc complete including cutting the wall and
168 13 making good the damages, including cost of all materials 35,315.04
complete as per PH specification complete as per direction of Er-
in-charge. 15mm dia CP angle stop cock with wall flange
.jaquar,Cat No-CQT-23059 Each 24.000 1471.46
Matrix Set-1 (Wash Basin 46x36 cm with one pair mounting
169 14 brackets, EWC & cistern complete with fittings & seat cover, one 1,53,093.20
no hinged rail 76 cm and 4 nos of grab rail 60cm) Each 2.000 76546.60
Overhead shower 120 mm Round shape Multi Flow (ABS Body)
170 15 chrome plated with Gray Face Plate)with Rubit Cleaning System. 6,121.84
(As per Cat no.OHS-1789 of Jaquar). Each 2.000 3060.92
171 16 15 mm dia C.P revolving shower with arm Each 2.000 1909.24 3,818.48
Supplying and installing ARISTO Plastic Dustbin Black 120 L with
172 17 Lid & Wheel, weight-7.5kg,Size (HxWxD-980x490x550mm), 10,924.44
Supplying, fixing and testing PVC muilty floor trap without SS
frame and cover 75mm dia outlet fixed on a bed of cement
173 18 concrete with (Heavy duty type) etc., complete. 913.32 0.00
Supplying, fixing and testing PVC Nahani floor trap without SS
174 19 frame and cover 75mm dia outlet fixed on a bed of cement 3,274.50
concrete with (Heavy duty type) etc., complete. Each 15.000 218.30
Supplying, fixing SS floor trap grating .
Providing and fixing stainless Single bowl kitchen sink stainless
steel Bowl Size- 540mm X 410mm, Depth-230mm (Cera, Cat no.-
B4711501) with C.I. brackets and stainless steel plug 40 mm,
including painting of fittings and brackets, cutting and making
176 21 good the walls wherever required : 0.00 0.00
Supplying, Installing, Testing and Commissioning Sink Cock With Each
Extended Swinging Spout including CP wall flanges, connectors,
adapters and all other fittings/ accessories required for
177 22 satisfactory installation complete. 0.00 2760.02 0.00 0.00
EXTERNAL P.H. & SANITARY WORK.
Supplying, fixing and testing PVC soil, waste, Rain and vent pipes
(SWR) supreme confirming to IS13592 : 2013, type B with rubber
ring/Solvent (confirming toIS5382) joint inclusive of allnecessary
specials like bends, tees,offsets, door bends, junctions, cowls,
etc.,laid underfloor/ fixed on walls,and in pipe shafts etc.,
complete.The rate shall include necessary GI supports, GI grip
180 a bolts,mm
. hangers, supports as with suitable GI U- mtr 65.00 967.84 62,909.34 0.00
Earthwork in excavation in all types of soil for 200mm dia site
leveling, and forming the bottom surface foundation, pits, trenches
and other civil works upto and including 1.5metre depth and
stacking the soil upto a lead of 100 metre and including
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
Supplying all materials, labour, T & P and constructing Gully Trap
chamber of the following inside size with 8 cm thick R.C.C. precast
cover slab in CC (1:2:4) mix using 12mm size h.g. chips,
foundation concrete (1:4:8) using 40mm size h.g. metal on bed
aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside
183 3 12mm thick cement plastering (1:3) finished with a floating coat of 8.00 2220.05 17,760.42 0.00
neat cement including fixing 100mm x100mm size gully trap,
150mm x150mm C.I gratig etc. all complete as per aproved
drawing, specification and direction of Engineer-in-charge.
Supplying all materials, labour, T & P and constructing of
Inspection chamber of the following inside size with 8 cm thick
R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g.
chips, foundation concrete (1:4:8) using 40mm size h.g. metal on
bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside
12mm thick cement plastering (1:3) finished with a floating coat of
neat cement including fixing 100mm x100mm size gully trap,
150mm x150mm C.I gratig etc. all complete as per aproved
drawing, specification and direction of Engineer-in-charge.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
OPEN WELL SUBMERSIBLE PUMPS FOR DOMESTIC WATER
TRANSFER FROM UGR TO OHR
Supply, installation, testing and commissioning Open well
submersible pump of required drive (Motor HP), having
discharge capacity and pumping head as described below with all
electrical accessories viz.main switch and starter, auto on/off
system with float arm (with fixed or flexible arm), over load
protection relay, power cable and control cable from main switch
and starter with auto on-off with dry running protection to
respective motors, earthing having required M.S. galvanised
supporting stay/ clamp etc. complete operational.
DOMESTIC 0.00 0.00
No. of Pumps : 1 working +1 stand by
RPM : 2900 (LOCATED AT UGR ).
192 B 10 KLD DOMESTIC WATER UGR TANK AND PUMP HOUSE
Earthwork in excavation in hard soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre
193 1 lift and stacking the soil upto a lead of 100 metre and including
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
195 b All kind of soil CUM 23.53 359.78 8,465.67
Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
196 2 ramming & watering with all leads & lifts including cost of all 16.09 181.48 2,920.08
labour,T&P completed as directed by the Engineer-in-charge.
Supplying and filling sand in foundation and over areas including CUM
watering, ramming, consolidating and dressing, labours, tools,
taxes etc. all complete as per the specification and direction of
Engineer-In-Charge.
Providing and laying plain cement concrete 1:3:6 (1 cement: 3 CUM
sand: 6 stone agregate 40mm nominal size) as levelling course
in foundation and plinth etc. including tempering, curring
,shuttering etc.complete all depth and height.
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
Cutting, straightening coiled or bent up M.S. Rod or tor steel of
SAIL/ TATA / RINL (VIZAG) make including bending, binding,
welding and joining if necessary and tying the grills and placing in
position as required for R.C.C. Work and for providing fan hooks
as required, hoisting, lowering, laying including cost,
conveyances, taxes of M.S. Rod or tor steel and binding wires of
18 to 20 gauge and labour required for the work for bending,
binding and tying the grills in all floors (Linear measurement will be
taken and quantity will be calculated basing on the standard
weight of B.I.S. for M.S. Rods or tor steel only. Wastage if any,
including weight of binding wire will not be considered for
measurement) etc. complete as per specification & direction of
Engineer-in-charge.
Providing & applying SikaTop seal 109 hi, Two Component Acrlic SQM
Cementations waterproofing coating over the injected & prepared
surface @ 2.2 Kg/sqm in two coats at the dry areas as per the site
condition. Lose Plaster to be removed up to the mother substrate
present if any in retaining wall prior to the application of
waterproofing coating.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
12mm cement plaster on external RCC/brick surfaces in cement SQM
mortar 1:4 (1 cement : 4 coarse sand) with a floating coat of neat
cement punning including necessary scaffolding, curing etc. all
complete at all floors and all heights.
Supplying all materials labour, T&P and fitting and fixing RCPC Each
206 9 Cover all compete as per specification and direction of the 2.00 1847.29 3,694.58
Engineer in charge.
RCC Over head water storage tank Domestic-5KLD & Fire 5
207 C kld Capacity 0.00
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
Cutting, straightening coiled or bent up M.S. Rod or tor steel of
SAIL/ TATA / RINL (VIZAG) make including bending, binding,
welding and joining if necessary and tying the grills and placing in
position as required for R.C.C. Work and for providing fan hooks as
required, hoisting, lowering, laying including cost, conveyances,
taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge
and labour required for the work for bending, binding and tying
213 2 the grills in all floors (Linear measurement will be taken and QTL 13.22 10682.42 1,41,221.62
quantity will be calculated basing on the standard weight of B.I.S.
for M.S. Rods or tor steel only. Wastage if any, including weight of
binding wire will not be considered for measurement) etc.
complete as per specification & direction of Engineer-in-charge.
12mm cement plaster to out side of brick surfaces with cement SQM
mortar of mix 1:6 (1 cement : 6 fine sand) including necessary
scaffolding, curing etc. all complete at all floors and all heights.
12mm cement plaster on external RCC/brick surfaces in cement SQM
mortar 1:4 (1 cement : 4 coarse sand) with a floating coat of neat
215 4 cement punning including necessary scaffolding, curing etc. all 36.16 280.84 10,155.17
complete at all floors and all heights.
Priming one coat with wall cement primer (water bound) to make sqm
an even finished surface in all floors and heights to wall surface of
approved make and shade including sand papering, applying putty
wherever necessary & cost of scaffolding, staging charges with
cost, conveyance, taxes of all materials, cost of all labour,labour
cess T&P etc. complete as per the direction of the Engineer-in-
Painting two coats with approved anti-fungal weather seal paints sqm
(ISI) of approved colour, shade on wall surface over a coat of wall
primer(ISI) water bound including sand papering, polishing the
217 6 surface, cost, conveyances of all materials and cost of all 30.54 128.03 3,910.04
labour,labour cess with T&P etc, complete as per specification &
direction of Engineer-in-charge.
2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm & sqm
218 7 down grades size hard granite crusher broken chips on new work 16.16 598.38 9,669.79
in Terrace Floor
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
219 D SEPTIC TANK
Earth work in excavation of foundation in all kinds of soil within Cum
50m initial lead and 1.5m initial lift including rough dressing &
220 1 breaking clods to maximum 5cm to 7cm and laying in layers not 24.71 359.78 8,890.21
exceeding 0.30m in depth and as per direction of the Engineer-in-
Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr Cum
221 2 in all kinds of embankments and road works and ordinary 4.94 383.38 1,893.91
earthwork in general. 1x6.10x2.70x0.30
Excavation of foundation in laterite rock or any hard rock (other Cum
than granite or disintegrated rock) removed by chiselling including
dressing and levelling the bed not exceeding 1.50 mtr. in depth
and depositing the soil within initial lead of 50 mtr. and as per
specification approved by the Department.
Supplying all materials, labour, T&P and filling in foundation and Cum
plinth with sand well watered and rammed including conveyance
223 4 of all materials to worksite, payment of royalty, taxes etc.all 3.29 1595.71 5,249.90
complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement Cum
concrete (1:3:6) with 4cm size hard granite metal including
224 5 watering, curing, conveyance of all materials to worksite, payment 3.29 8812.12 28,991.88
of royalty, taxes etc all complete as per specification and direction
of the Engineer in charge
Supplying all materials, labour, T&P and providing 6mm thick Sqm
cement plaster (1:4) on RCC work including watering, curing,
225 6 conveyance of all materials to worksite, payment of royalty, taxes 39.68 257.95 10,235.38
etc all complete as per specification and direction of the Engineer
Supplying all materials, labour, T&P and providing cement punning Sqm
including watering, curing, conveyance of all materials to worksite,
226 7 payment of royalty, taxes etc all complete as per specification and 44.96 48.38 2,175.16
direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and
smooth centering and shuttering for R.C.C works including false
work and dismantling them after casting including conveyance of
all materials to worksite, payment of royalty, taxes etc all
complete as per specification and direction of the Engineer in
228 a R.C.C floor and roof slabs up to 4.30m height 10.05 899.28 9,037.74
229 b R.C.C beams,columns,girder and bressmer etc. 1,00,117.08
Supplying all materials, labour, T&P and providing M.S Qntl
reinforcement for R.C.C work including cutting, bending, binding,
and tying the grills and placing in position including cost of binding
230 9 wire 18 to 20 gauge, conveyance of all materials to worksite, 14.25 10601.47 1,51,071.00
payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement Cum
concrete (1:1:2) with 12mm size hard broken granite chips for
R.C.C works including hoisting, laying, watering, curing,
conveyance of all materials to worksite, payment of royalty, taxes
etc all complete as per specification and direction of the Engineer
Supplying all materials, labour, T&P and providing cement
concrete (1:2:4) with 12mm size hard broken granite chips
including watering, curing, conveyance of all materials to worksite,
payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 12mm thick Sqm
cement plaster (1:4) on brickwork including watering, curing,
233 12 conveyance of all materials to worksite, payment of royalty, taxes 5.28 257.95 1,361.97
etc all complete as per specification and direction of the Engineer
Supplying all materials, labour, T&P and providing brick work with Cum
Fly ash bricks having crushing strength not less than 75kg/cm² with
dimensional tolerance ± 8 percent in cement mortar (1:4)
234 13 including watering, curing, conveyance of all materials to worksite, 0.60 7066.08 4,239.65
payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying all materials, labour, T&P and making MS step iron in Each
20mm diameter MS steel bars and fixing into walls of man
235 14 hole/septic tank duly embedded in cement concrete (1:3:6) 6.00 333.70 2,002.22
complete as per specification and direction of the Engineer in
Filling in foundation and plinth with excavated materials, moorum Cum
236 15 including watering and ramming as directed by the Engineer in 9.84 177.59 1,747.49
Supplying all materials, labour,T&P and providing 25mm thick Sqm
grading concrete (1:2:2) on roof slab with 6mm size hard granite
chips on new work including watering, curing, conveyance of all
materials to worksite, payment of royalty, taxes etc all complete
as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing shoring and Sqm
shuttering foundation trenches, pits etc with close wooden planks
or sheets shuttering etc all complete as per direction of the
Engineer in charge.
239 18 Dewatering with 5 H.P diesel engine pump during excavation per hour 30.00 69.62 2,088.60
Supplying all materials, labour, T&P and providing, fitting and Each
fixing U-PVC SWR Tee in wall including filling the recess with
cement concrete (1:3:6) with 12mm size h.g chips all complete
including watering, curing, conveyance of all materials to worksite,
payment of royalty all complete as per specification and direction
of the Engineer in charge
160mm U-PVC plain Tee
Supplying all materials, labour, T&P and constructing vent base as each
per P.H.D specification etc all complete.
Supplying all materials, labour, T&P and fitting and fixing U-PVC
SWR soil waste ventilating pipes and fittings of the following
outside diameter conforming to ISI No 13592/1992 to walls with
nails, bobbins and wooden plugs or laying in trenches including
jointing with supply of approved rubber lubricant by non-heat
application method/as per manufacturer's specification, testing,
earthwork in excavation in all kinds of soil and refilling of trenches
as per specification and direction of the engineer in charge.
243 a 110mm diameter U-PVC SWR pipes Mtr 2.20 585.63 1,288.39
244 b 110mm U-PVC cowl Each 1.00 68.68 68.68
245 E SOAK PIT 0.00
Earthwork in excavation in all types of soil for site leveling,
foundation, pits, trenches and other civil works upto and including
1.5metre lift and stacking the soil upto a lead of 100 metre and
including dewatering, removing slush,shoring and strutting (as
required), complete as per specification and as directed by the
Engineer-In-Charge.
247 a All type of Soil Cum 26.01 326.74 8,498.56
Filling at all depth with available excavated earth (excluding rock) Cum
in trenches, plinth, sides of foundations etc. in layers not
249 2 exceeding 15cm in depth: consolidating each deposited layer by 12.59 181.48 2,284.88
ramming and watering complete (lead upto 100m) as directed by
the Engineer-In-charge.
Supplying of filling sand in foundation and over areas including Cum
watering,ramming, consolidating and dressing, labours, tools,
taxes etc., all complete as per the specification and direction of
Providing and laying plain cement concrete 1:3:6 (1 cement: 3 Cum
sand: 6 stone agregate 40mm nominal size) as levelling course
in foundation and plinth etc. including tempering, curring
,shuttering etc.complete all depth and height.
Brick work with Fly Ash. Bricks in cement mortar (1:6) in Cum
foundation having crushing strength not less than 75.00 kg/cm2
immerging the bricks in water not less than six hours before use in
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-250 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
Supplying, straightening, cutting, bending, placing in position and Qntl
binding reinforcement steel work in RCC/reinforced brick works as
per drawing and specification including preparation of respective
255 7 bar bending schedule and binding ( Binding wire to be used as per 1.00 10601.47 10,601.47
the IS code) etc. all complete as per direction of Engineer-in-
charge.Cold Twisted bars,
256 Sub-Total of Plumbing Works 28,56,279.40
257 Electrical Works
258 INTERNAL ELECTRICAL
259 Sub-Head I (modular Wiring Items)
Recessed wirring to light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FRLS PVC insulated copper conductor
of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI
marked 6A modular type switch ISI marked (vision) and ceiling
rose ISI marked of modular type G.I box with metallic cover plate
(both side) Panasonic (vision) of suitable size, modular box with
1.5 sq. Mm FRLS PVC insulated single core multistandard copper
260 1 conductor as earth wire including all accessories and connection 0.00 0.00
as per direction of Engineer -in -Charge. . All the switches &
sockets should be warrantied for a replacement period of 2 years
against defects with ncessary test report & Warrnaty certificate to
be submitted to the department for genuinity of product & to avail
free after sales service within warranty period for acceptance of
Supplying ,fixing of 6A Plug on the same board in existing switch
board with complete fitting by 01 no of 6A switch & socket
(modular type)( (flame retradant type)) & other required
accessories of ISI marked as approved as per direction of Engg. -
in -Charge. .(Maximum 02 nos point in one circuit).All the
264 2 switches & sockets should be warrantied for a replacement period 15 231.28 3,469.20 0.00
of 2 years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of
product & to avail free aftersales service within warranty period for
acceptance of materials.
Supplying,fixing of 6A Plug on the separate board with complete
fitting by 01 no of 6A switch & socket(modular type)( (flame
retradant type)) with suitable size modular box & cover( flame
retradant type) including supplying of all required accessories of
ISI marked as approved as per direction of engg-in-charge.)
.(Maximum 02 nos point in one circuit).All the switches & sockets
265 3 should be warrantied for a period of 2 years against 15 650.18 9,752.70 0.00
manufacturing defects against which ncessary test report &
Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free aftersales service within
warranty period for acceptance of materials.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying,fixing of 1x16A Plug on the separate board with
complete fitting by 01 no of 16A switch & socket(modular
type)((flame retradant type)) with suitable size modular box &
cover(flame retradant type) including supplying of all required
accessories of ISI marked as approved as per direction of engg-
in-charge.. (For equipement power)All the switches & sockets
should be warrantied for a replacement period of 2 years against
defects with ncessary test report & Warrnaty certificate to be
submitted to the department for genuinity of product & to avail free
aftersales service within warranty period for acceptance of
Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete
fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant
type) with suitable size modular box & metallic cover plate (both side)( flame
retradant type)including supplying of all required accessories of ISI marked as
approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand(
Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in
one circuit).All the switches & sockets should be warrantied for a replacement
period of 2 years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of product & to avail
free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with
complete fitting by 01 no of 16A+3 nos 6A switch &
socket(modular type) ( (flame retradant type) with suitable size
modular box & metallic cover plate (both side)( flame retradant
type)including supplying of all required accessories of ISI marked
as approved as per direction of engg-in-charge. Make-Schneider
(Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement
power). (Maximum 02 nos point in one circuit).All the switches &
sockets should be warrantied for a replacement period of 2 years
against defects with ncessary test report & Warrnaty certificate to
be submitted to the department for genuinity of product & to avail
free after sales service within warranty period for acceptance of Nos
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable in recessed HMS FRLS PVC conduit of
mentioned size l as required as per direction of Engg.-in-Charge.
269 7 2 nos single core 1.5 sq. mm copper wire for phase and neutral Mtr 200 187.62 37,524.00
and 01 no of single core 1.5 sq. mm copper wire for earth
continuty conductor. In 20 mm dia non metallic heavy duty
conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable in recessed HMS FRLS PVC conduit of
mentioned size as required as per direction of Engg.-in-Charge.
2 nos single core 2.5 sq. mm copper wire for phase and neutral
270 8 and 01 no of single core 1.5 sq. mm copper wire for earth Mtr 300 204.14 61,242.00
continuty conductor in 20 mm dia non metallic heavy duty
conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT )
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable in recessed HMS FRLS PVC conduit of
mentioned size as required as per direction of Engg.-in-
271 9 2 nos single core 4 sq. mm copper wire for phase and neutral and Mtr 200 225.38 45,076.00
01 no of single core 1.5 sq. mm copper wire for earth continuty
conductor in 20 mm dia non metallic heavy duty conduit .(PDB to
PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable I in recessed HMS FRLS PVC conduit of
mentioned size l as required as per direction of Engg.-in-
272 10 2 nos single core 6 sq. mm copper wire for phase and neutral and Mtr 30 261.96 7,858.80
01 no of single core 2.5 sq. mm copper wire for earth continuty
conductor in 25 mm dia non metallic heavy duty conduit .(LFDB
TO LBDB/UBDB) (2X6+1X2.5)
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable in recessed HMS FRLS PVC conduit of
mentioned size as required as per direction of Engg.-in-Charge.
4 nos single core 6 sq. mm copper wire for phase and neutral and
02 nos of single core 4 sq. mm copper wire for earth continuty
conductor in 32 mm dia non metallic heavy duty conduit.(LFDB
TO LBDB/Medical equipement) (4X6+2X4)
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable in recessed HMS FRLS PVC conduit of
mentioned size as required as per direction of Engg.-in-Charge.
4 nos single core 10 sq. mm copper wire for phase and neutral
274 12 and 02 nos of single core 6 sq. mm copper wire for earth continuty Mtr 35 526.28 18,419.80
conductorin 32 mm dia non metallic heavy duty conduit .(LFDB
TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
Supplying and installation of 25A AC starter Modular type,
Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod
Box of suitable size including modular coveras required as per
direction of Engg.-in-Charge .All the Components should be
275 13 warrantied for a replacement period of 2 years against defects 12 739.86 8,878.32
with ncessary test report & Warrnaty certificate to be submitted to
the department for genuinity of product & to avail free aftersales
service within warranty period for acceptance of materials.
Supply and fixing CALL bell (Ding dong type) /Buzzer on the
existing switch box/cover. .as required as per direction of Engg.-in-
Charge.All the Components should be warrantied for a
276 14 replacement period of 2 years against defects with ncessary test 2 252.52 0.00 505.04
report & Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free aftersales service within
warranty period for acceptance of materials. Nos
S/F of Bakelite angle holder/batten holder A catagory ISI marked
as approved )of ISI marked conforming to IS-1258/1987 in place
of ceiling rose as per direction of Engg.-in-Charge .All the
277 15 Components should be warrantied for a replacement period of 2 Each 5 89.68 448.40 0.00
years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of
product & to avail free aftersales service within warranty period for
acceptance of materials.
S/F of 5 step type Modular electronic Fan Regulator ISI Marked
with all connection complete in all respect as per direction of
Engineer in charge
279 B Sub-Head II (Light fitting Fixture & Fan)
Supplying, installation, of exhaust fan of heavy duty 300 mm
sweep 1400 rpm with louvers of exhaust fan in the existing wall,
280 1 including fixing & conntection as required as per direction of Engg.- 3 3,693.40 0.00 11,080.20
in-Charge. Replacement Warranty will be 2 years.
Supplying, installation, of exhaust fan of heavy duty 380 mm
sweep 1400 rpm with louversof exhaust fan in the existing wall, including
fixing & conntection .as required as per direction of Engg.-in-Charge.
Replacement Warranty will be 2 years. Nos
Supplying, installation, testing and commssioning of 1200 mm
sweep white/milky colour BLDC ceiling fan with aluminium blades
having wattage not more than 28W and air delivery ≥215m3/min
including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm
282 3 PVC insulated, copper conductor, single core cable etc. as required as per 20 4,394.32 0.00 87,886.40
direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan
Supplying and fixing of Energy efficient Recess /Surface
mounted square/round shaped LED luminaire made up of CRCA
powder coated sheet steel of not more than 25W and system
lumens output not less than 3250 lumens (130 lm/ wt) with
diffusers for better light transmission and pure effect with High
luminous flux LEDs for better light output, CRI not less than 80,
283 4 CCT of 5700-6500 degree K, THD less than 10%,internal surge 35 5,574.32 0.00 1,95,101.20
protection of 3 KV, complete with Non integrated isolated
electronic driver (protects the output /secondary side from any
disturbance on the input / primary side ensuring safe
operation)and all other accessories suitable for operation on140-
270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty)supply
.as required as per direction of Engg.-in-Charge . The luminaire No
must be Replacement Warranty will be 2 years.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying and fixing of Energy efficient surface /recess
mounted square /round shape 18 W LED luminaire of dimension
of consists of white powder coated , die-cast Alluminium housing
with high quality frosted diffuser for glare-free uniform lighting
distribution with wattage not more than 18 watt and lumen output
of 1800 lumens, , CRI not less than 80,CCT of 6000 degree
K,THD less than 10%, with electronic driver, internal surge
protection of 3 KV , L70 B50: 50000 hrs and all other
accessories suitable for operation on 220 V to 240 V supply as
required as per direction of Engg.-in-Charge..The luminaire
should be Replacement Warranty will be 2 years
SITC of energy efficient LED tube light fittings with decorative
alluminium batten and LED tube light having power rating not
more than 20 watt and lumen output not less than 2000 lumen
complete with electronic driver and all other accessories with 859.04
diffuser having 2 years warranty i/c connection etc as required as
per direction of Engg.-in-Charge. . The luminaire should be
Replacement Warranty will be 2 years .
SITC of Sleek LED 10 watt mirror light fitting with extruded
polycarbonate housing,High optically efficient diffuser,above wash
286 7 basin complete with all accessoriesetc. directly on wall, including connection 10 868.48 0.00 8,684.80
with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and
earthing etc. as required as per direction of Engg.-in-Charge. Nos
Supplying and fixing extra conduit down rod of 20 cm length G.I.
pipe 15 mm dia, heavy gauge including painting etc. as
287 8 requiredas required as per direction of Engg.-in-Charge . 15 38.94 0.00 584.10
(Note : More than 5 cm length shall be rounded to the nearest 10
cm and 5 cm or less shall be ignored)of ISI mark as approved.
288 C BDBS,DB,AC DB,FLOOR PANELS,MCBS
Supplying and fixing of following mentioned way, three pole/single
pole and neutral, sheet steel,double door MCB distribution board, 415
volts/240 volts shall be as per IEC 61439-3,integrated door earthing system
offering additional safety to the user,High quality polyurethane Gasket,the box
and cover shall be fabricated to withstand IK09,the DB should be properly pre-
treated with 7 tank process and duly powder coated, phosphatized with powder
289 1 coated finish, on surface/recess, complete with terminal blocks,with suitable 0.00 0.00
size FR PVC insulated copper conducter up to terminal blocks, tinned copper
busbar, neutral busbar, earth bar, din bar as per direction of Engg.-in-Charge.
The Distribution boards should be Replacement Warranty will be 3 years.
4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC
61439-3 suitable for Flush mounting and Surface mounting with
290 2 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth 6 5,038.60 30,231.60
Bar & Cable ties for cable management, prefitted masking sheet,
IP43-IK09 with metal door Warranty on DB is 3 years Nos
Supply and fixing of 12 way DD single pole and neutral sheet
steel MCB distribution board 250V on surface/recess complete
with tinned copper bus bar, neutral bus bar, earth bar, din bar,
291 3 detachable gland plate, interconnections, phosphatized and 2 2321.06 4,642.12
powder painted including earthing etc. as required (but with out
MCB/ RCCB/ Isolator) Warranty on DB is 3 years
2+4 way MCB Enclosure DB (GLAZED door)(only each EM.
292 4 CONNECTION UPS LOAD)Warranty on DB is 3 years 50 378.78 18,939.00 0.00
8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for
Flush mounting and Surface mounting with 100A Copper Bus Bar
for each phase, with neutral Bus bar, Earth Bar & Cable ties for
cable management, prefitted masking sheet, IP43-IK09 with metal
door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD)Warranty on DB is
Supplying and fixing 20 amps rating, 240 volts, C series,10KA
breaking capacity, Double poles MCB of in the existing MCB DB
complete with connections as per direction of Engg.-in-Charge. .Warranty on
MCB is 3 years. Nos
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C
series,10KA breaking capacity, single poles MCB of the existing
295 7 MCB DB complete with connections as per direction of Engg.-in-Charge. 3.00 5405.58 16,216.74 0.00
.Warranty on MCB is 3 years.
Supplying and fixing 40 Amps rating, C series,10KA breaking
capacity,4P, 415 volts, MCB . - Acti 9 in the existing MCB DB
complete with connections, testing and commissioning etc. as
required as per direction of Engg.-in-Charge. .. The MCB should
be Replacement Warranty will be 3 years..
Supplying and fixing 40 Amps rating,C series,10KA breaking
capacity, 4P, 415 volts, RCCB 30mA . in the existing MCB DB
297 9 complete with connections, testing and commissioning etc. as 3.00 3499.88 10,499.64 0.00
required as per direction of Engg.-in-Charge. . The MCB should
be Replacement Warranty will be 3 years. Nos
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying and fixing 25Amps rating,C series,10KA breaking
capacity, DP 240 volts, MCB in the existing MCB DB in the
298 10 existing MCB DB complete with connections as per direction of 3.00 6182.02 18,546.06 0.00
Engg.-in-Charge. The MCB should be Replacement Warranty
will be 3 years. Nos
299 D (Earthing) INSTALLATION
Supplying,installation,testing & commissioning of materials and
installation of GI earth plate 600mmx600mmx6mm thick ISI
marked with G. I. nut bolts & washers including cost of burnt
300 1 wood charcoal, salt, foreign soil, water pouring arrangements, 2.00 15,340.00
brick masonary enclosure on top with removable RCC cover
complete with labour for excavation of pit in all kinds of soil & rock
as required and as per direction of Engineer-in-charge. Nos 7,670.00
Providing and fixing 6SWG GI wire on surface or in recess for
301 2 loop earthing as required.as per direction of Engg.-in-Charge. 80.00 2,360.00
Providing and fixing 25mm x 5 mm GI strip on surface or in recess
302 3 for connections etc. as required as per direction of Engg.-in- 80.00 14,348.80
Charge. Nos 179.36
303 E CABLING AND END TERMINATION MAIN AREA
Supplying of one number PVC insulated armoured and PVC
sheathed XLPE property AL. conductor power cable of 1.1 KV
304 1 grade Gloster of following size cables as per direction of Engg.- 44.00 676.14 29,750.16 0.00
Supplying of one number PVC insulated armoured and PVC
sheathed XLPE property AL. conductor power cable of 1.1 KV
grade POLYCAB/HAVELLS/Finolex or equievalant reputed make
ISI marked as approved of following size cables as per direction
of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to
be submitted to the department for genuinity of product & to avail
free after sales service within warranty period for acceptance of
306 a 3.5core x 95 sq mm ( main panel ) Mtr 85.00 1145.78 97,391.30
4core x 16 sq mm
3.5core x 35 sq mm
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 25 SQ. MM direct in ground in the
309 3 trench in one horizental formation including excavation ,sand 15.00 185.26 2,778.90
coushing protection covering and refilling the trench etc as
required as per direction of Engg.-in -charge. Mtr
310 4 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv Mtr 80.00 210.04 16,803.20
Laying exceeding
of PVC Insulated25PVC
not exceeding 120 of
power cable SQ.
311 5 grade size exceeding 120 SQ. MM but not exceeding 400 SQ. 236.00 4,248.00
MM direct in ground in the trench in one horizental formation Mtr 18
Laying of excavation ,sand
PVC Insulated coushing
PVC Seatedprotection covering
/XLPE power cableand
grade size not exceeding 25 SQ. MM direct in ground in the
EXISTING PIPE etc as required as per direction of Engg.-in -
charge. Mtr 18
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM
direct in ground in the EXISTING PIPE etc as required as per
direction of Engg.-in -charge. Mtr 18
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
314 8 grade size not exceeding 25 SQ. MM in open duct etc as required 54.28 542.80
as per direction of Engg.-in -charge. Mtr 10
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size exceeding 25 SQ. MM in open duct 400 SQ. MM
direct in ground in the EXISTING PIPE etc as required as per
direction of Engg.-in -charge. Mtr 10
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
316 10 grade size not exceeding 25 SQ. MM in surface with shaddle and 123.90 1,239.00
screw etc as required as per direction of Engg.-in -charge. Mtr 10
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 120 SQ. MM From 25 SQ. MM in
317 11 surface with shaddle and screw etc as required as per direction of 188.80 1,888.00
Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 400 SQ. MM From 120 SQ. MM in
318 12 surface with shaddle and screw etc as required as per direction of 1,538.72 0.00
Engg.-in -charge.
Supplying and making end termination with brass compression
319 13 gland and aluminium lugs for following mentioned size cable.as 0.00 0.00
per direction of Engg.-in-Charge.
4 core x16sq mm
3.5 core x35 sq mm
3.5 core x95 sq mm 1,128.08
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Providing,fixing and laying of following dia G.I. pipe (medium
324 14 class) in ground complete with G.I fitting incl. trenching(75 mm 6,887.66
depth)and refilling as per direction of Engg.-in-Charge.
Providing,fixing and laying of following dia HDPE pipe (medium
class) in ground complete with fitting incl. trenching(75 mm
depth)and refilling as per direction of Engg.-in-Charge.
326 F MAIN CONTROL PANEL AT GF
S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type
electrical main panel (for both light and power circuit) made out by 2mm CRCA
steel sheet duly derusted & painted by siemens gray powder cote paint fallowed
by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.- Set
In commer-1-01 number of 630A 4P Icu=100%Ics,36Ka LSIG
MCCB with micro processor based release Electrical locking for
In commer-2-01 number of 400A(320-400) 4P
329 b Icu=100%Ics,36kA LSIG MCCB with micro processor based 0.00
release Electrical locking for normal & DG (DG 160 KVA
In commer-2- 01 no of 400A 4P onload changeover switch (160
Busbar-1&2 04 numbers of 800Amps copper busbar with 1.6A/SQ.MM
current carring capacity. busbar duly sleeved by color coated PVC sleeve &
supported by suitable size DMC insulator. (for outgoing)
Out going- 08 numbers of 100A 4P MCCB,,25Ka MCCB withTMR based
332 e release with adjustable overload ,Icu=100%Ics 0.00
Out going- 4 numbers of 160A 4P Icu=100%Ics,,25Ka MCCB withTMR
333 f based release with adjustable overload 0.00 0.00
Out going- 6 numbers of 32A rating,10 KA breaking capacity,C series, 4P
Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC
(ii) 02 set of digital type multifunction meter with CT for
voltage,current,frequency,PF,THD indication with RS 485
COMPACTIVITY FOR bms data.
CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER
Supplying,fixing of perforated cable trays with horizental & vertical
bends,reducers ,tees,crossover,brakets & other accessories ar
requited confirming to IS-IEC -61537 ,the cable tray shall be
galvanised for corrosion protection confirming to DIN EN
10346/ISO 1461. Size 60mm(H) x 200mm(W) of.The Load
bearing capacity of the Cable Trays should be minimum of
104.8Kg/meter at the span of 1.5Meter as per UL specifications
as required as per direction of Engg.-in-Charge.
Supplying,fixing of perforated cable trays with horizental & vertical
bends,reducers ,tees,crossover,brakets & other accessories ar
requited confirming to IS-IEC -61537 ,the cable tray shall be
galvanised for corrosion protection confirming to DIN EN
10346/ISO 1461. Size 60mm(H) x 300mm(W) of.The Load
339 2 bearing capacity of the Cable Trays should be minimum of 12 1,146.96 0.00 13,763.52
104.8Kg/meter at the span of 1.5Meter as per UL specifications
as required as per direction of Engg.-in-Charge.
GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY
WITH JUNCTION with internal dimensions of size 38mm(H) x
225mm(W), of .(With all
accessories,bend,cover,supporter)WITH REQUIRED SIZED
340 3 JUNCTION BOX ,COVER CONNECTOR as required as per 21 2,101.63 0.00 44,134.27
direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM
LIGHTENING PROTECTION SYSTEM
Supply of 8 mm Aluminum Round Conductor.Tested as per IEC
62561. as per direction of engineer in charge.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supply of Roof conductor holder for parapet- Polyamide
Conductor holder:With M8 female thread or diameter 7mm, M8
Screw to connect the conductor holder.Weather and
343 2 temperature resistant from -35 to +90 degree Celsius tested. No 150 60.18 0.00 9,027.00
Conductor holder @ 1 meter distance.Tested as per IEC 62561.
as per direction of engineer in charge.
Supply of Polyamide roof cable holder for flat roof:
DIN 48829 Form B1. Closed form with bottom. Filling weight
344 3 1Kg (frost-resistant concrete). Sleeve from polyethylene, black No 12 234.82 0.00 2,817.84
@ 1 meter distance. Tested as per IEC 62561. M
Supply of Connector: For T cross and parallel connectors. Quick
installation using hexagonal bolt M10X30 high-grade hot dip
345 4 galvanised. Tested as per IEC 62561.(2nos/expansion piece ). No 12 239.54 0.00 2,874.48
Supply of 1 mtr vertical air terminal with mounting accessories
on the flat surface to meet the requirements of IS/IEC 62305.
346 5 Tested for Electrical , mechanical and chemical as per IEC No 6 1,373.52 0.00 8,241.12
62561. Tested for 100kA lightning current.
Supply of Vertical air terminal with accessories:Providing of Air
as per IS-IEC -62305 part-3
347 6 Nominal size Ø10/16 mm aluminium rod: No 5 3,724.08 0.00 18,620.40
3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN
48801) Suitable for high wind load.
Tested as per IEC 62561.
Supply for Providing of Stand for Fang Fix system 16 kg with base
348 7 clamp ,made up of frost resistant concrete and clamp tested No 5 2,902.80 0.00 14,514.00
upto 100KA lightning current .
Supply for Providing of Stand for Fang Fix system 16 kg made up
resistant concrete.
Supply of Test Joint (Folding Clamp) suitable to connect 8mm
round conductor and max by 30x3 mm GI strip as specified in
drawing and directed by Engineer.
Tested for 100kA lightning current.
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr
For Test Joint .Internal dimensions: 100x100x48 mm
Supply of Galvanised Steel Flat 30X3 mm thickness from earth
electrode directly in ground as required. Flat conductor Hot
Dipped Galvanized. Tested as per IEC 62561.
Supply for Providing of Cross connector for Flat: Suitable for
30mm Galvanised steel strip. Installed with 4 nos of hexagonal
plate. Tested for 100kA lightning current.
Supply of flat conductor holder- Fit: FL 30, With mounting hole
6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from
hot-dip galvanised steel, Bottom section from polyamide, black.
Supply for Providing of Plastic Corrosion Protection strip: Approx
1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical
Supply of UL Listed maintenance free ,Low carbon copper
coated earth rod of 3 metre electrode having diameter of 17.2
mm with copper coating thickness of 250micron tested as per
Supply of universal clamp made of SS to connect rod with flat
Supply of Earth conductivity enhancing mineral compound shall
kg/pit tested as per IEC 62561-7,TCLP tested
Supply of The above arrangements shall be provided with Heavy
earth champer of 5000kg load bearing capacity to ensure the
safety of earthing system
Installation of The above arrangements including all accessories
360 19 as per Direction of Engg. In charge. Job 1 16,816.18 0.00 16,816.18
Subhead- 1 (Lan System) 0.00
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing
surface/ recessed steel/ PVC conduit as required: The 4 pair
Unshielded Twisted Pair cable shall be UL Listed,exceeds the
requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4
twisted pairs separated by internal PE Cross Separator. Full
separator. Half shall not be accepted. Rip Cord is must,Insertion
Loss of 32.8 db/100m at 250 MHz ,Cable should support
operating temperature from -20° to +70°C Cable support
Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay
Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ±
15 Ω @100 MHz. and Propagation Delay @250 MHz : 536
ns/100m, ETL Verified 4 connector channel performance up to
700 MHz , RoHS Compliant.
SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or
exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, &
EN50173. The information outlet NEXT, PSNEXT, FEXT,
ELFEXT, PSELFEXT and return loss should be verified for CAT6
@ 250Mhz & CAT6A @ 500Mhz. The information outlet connector
shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors
shall be compatible as per IEEE 802.3af standard for POE
application. The PVC material of Face plate should complie ABS
/UL94-V-O certified.
SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or
exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, &
EN50173. The information outlet NEXT, PSNEXT, FEXT,
ELFEXT, PSELFEXT and return loss should be verified for CAT6
@ 250Mhz & CAT6A @ 500Mhz. The information outlet connector
shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors
shall be compatible as per IEEE 802.3af standard for POE
application. The PVC material of Face plate should complie ABS
/UL94-V-O certified.
SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should
accommodate Cat6 with Rear Cable Management and Front
removable Tooless Information outlet. Should have easy clip
365 4 management with labels and clear label covers, Made with of Nos 2 11,585.24 0.00 23,170.48
Dicast Aluminium Alloy Material and Non Corrosive with Cat6
toolless RJ45 x 24 ports with color code front panel with patch
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch
Cords are Factory Tested for Better Quality and Suitable for the
High Speed Data Transmission. Complies to the Standard
ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds
366 5 Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Nos 6 403.56 0.00 2,421.36
Reduced Toxic Gasses Emitted During Combustion , RJ45,
8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory
Tested , Transparent Boot Cable Assemblies.
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch
Cords are Factory Tested for Better Quality and Suitable for the
High Speed Data Transmission. Complies to the Standard
ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds
367 6 Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Nos 6 480.26 0.00 2,881.56
Reduced Toxic Gasses Emitted During Combustion , RJ45,
8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory
Tested , Transparent Boot Cable Assemblies.
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber
cable through existing conduit: The Fiber should be OS2 Single
Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated
Steel tape Central loose tube. ( Standard Approved: ISO 11801
368 7 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation Mtr 25 145.14 0.00 3,628.50
G.652.D - the oder ITU designations A, B and C are also fulfilled /
OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are
fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket.
SITC of Rack mount Draw Type Loaded 6 port LIU available in
Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled
Steel as Raw Material , Consist of Top Cover and Bottom Panel ,
Easy to Assemble and Dissemble , Three Types of Input Holes
369 8 Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC Nos 2 9,848.28 0.00 19,696.56
or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray
,Adaptor, SM, Duplex SC, PC Type ,Support the TIA/EIA
Telecommunication Wiring Standards. Compact Design ,
Telcordia GR-326-Core .
SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC
Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are
370 9 offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 Nos 2 2,715.18 0.00 5,430.36
db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db,
UPC>=50db, APC>=60db.
Supply & Installation of 1000Base LX Fiber Transceiver.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000
Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45
port console port ,Switching Capacity 128 Gbps , Throughput 96
Mpps ,MAC Address 16k , Switch should support IEEE 802.3af
(15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above
, Switch should support DHCP server/relay/client, DHCP
snooping/option82 , Switch should support Console, Telnet, SSH
v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP,
NTP, ZTP, SPAN, RSPAN,Switch should support support
ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C
,Power Supply AC: 100-240V.
Supply , Installation, testing , commissioning of 32 Channel NVR
with 4 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels
Resolution Display and Recording, H.265 video compression
technology with real time encoding, Full function CMS (Central
monitoring software) supported, Two way audio supported, Dual
streaming technology to encode recording stream and network
stream separately, Supports remote monitoring on Mobile Client
(Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP,
NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search
(accurate to second), Record Snapshot, FTP, Preset Calling,
Email notification supported, Manual/ Alarm/ Motion Detection/
Continuous, CE, FCC, RoHS). Make-Honeywell series
SITC of 24U 600/650D UL Listed Floor mount Rack with Front
perforated door with 3 point lock, Rear mesh door with Cam lock
and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-
Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp
374 13 MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable Nos 1 47,347.50 0.00 47,347.50
2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with
Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray -
Ventilation - 495W - 375D and H/W screw920sets).
Supplying and fixing of following sizes of Heavy class PVC FRLS
conduit ISI marked along with accessories in surface/recess
including cutting the wall and making good the same in case of
375 14 recessed conduit as required as per direction of Engg.-in-Charge . 0.00 0.00
Subhead- 3 (IP-CCTV System)
Supply, Installation, Testing & Commissioning of 5MP IP Network
TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8" CMOS
or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at
various resolution & Frame Rates, Min. Illumination required 0.007
lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 50m IR
distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N
Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video
Compression technology such as H.265, H.264 & MJPEG , Fixed
Lens 2.8mm, Field of View FoV H:90°, V:62°, BLC, HLC, WDR,
3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence
379 1 Video Analytics : Video Motion Detection, Tampering, Loitering, Nos 10 17,638.64 0.00 1,76,386.40
Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of
Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256,
SSH/Telnet closed, Stream Encryption, 2-Way Audio Full Duplex
Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE
(802.3 af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast
Aluminium Housing, Having Operating temp range : –40°C to 60°
C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-
4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA compliant.
Supply, Installation,Testing & Commisioning of Surveliance 10 TB
SITC of 55" UHD IPS Commercial Digital Display for Small Size
Discussion & Chambers: Brightness (440 nits or higher), Dynamic
Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static
(Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms,
381 3 Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Nos 1 1,10,777.22 1,10,777.22
Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C
Broadcasting System, Commercial Smart UX, webOS version
(webOS 6.0), BIS Certification with 3 years onsite warrenty.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supply , Installation, testing , commissioning of 32 Channel NVR
with 4 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels
Resolution Display and Recording, H.265 video compression
technology with real time encoding, Full function CMS (Central
monitoring software) supported, Two way audio supported, Dual
streaming technology to encode recording stream and network
stream separately, Supports remote monitoring on Mobile Client
382 4 (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, Nos 1 43,160.86 0.00 43,160.86
NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search
(accurate to second), Record Snapshot, FTP, Preset Calling,
Email notification supported, Manual/ Alarm/ Motion Detection/
Continuous, CE, FCC, RoHS).
Sub-Total of Electrical Works 7,31,515.04 14,46,258.65
383 Fire fighting Works
PUMPS AND APPURTENANCES
Supplying, installation, testing and commissioning of Electric
Motor Driven Pressurization Terrace Pump having discharge of
384 1 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor Nos 1 77,266.40 0.00 77,266.40
suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base
SITC of FRLS,PVC outer sheateh, steel armoured, aluminium ,
385 2 1100v grade power cables with glands etc.The minimum size of 0.00 0.00
the cables shall as mentioned below,
Supply, installation, testing and commissioning of Floor/Wall
mounted sectionalised, front operated top entry dust and vermin
proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4
wire, 50Hz distribution system fabricated out of 2.0 mm thick
CRCA sheet, insulated busbar with heat shrienkable PVC sleeve,
base frame, complete with all accessories including
interconnections, earth bus etc as required comprising of One (1)-
63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating
lamps with control fuse/ MCB, Digital Voltmeter with selector
switch. DOL starter with O/L and Single Phasing Preventor
suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual
switch and ON/OFF push button.as per direction of engineer in
charge Control panel for fire pumps for auto action.
389 B PIPE & VALVES ETC. 0.00
Supply,Installation,Testing & Commissioning of 'C' Class heavy
duty MS pipe (as per IS 1239 upto 100 mm NB and IS 3589 for
above 100 mm 6.33mm thick) with flanges and fitting such as
bends, tees, reducers, rubber insertions and galvanized nuts and
bolts of following size on surface along wall / shaft with MS
390 1 bracket, suspended from ceiling/ beam with suspenders duly 0.00
painted with two coats of primer and finished with enamel paint of
approved colour laid through pipe or in trench after wrapping with
hassen cloth after applying coal tar primer as required as per
direction of Engineer-in- charge.
Providing, fixing, testing and commissioning of following size
manually operated hand lever type cast iron double flanged slim
seal wafer type Butterfly valves with EPDM iron disc as per IS-
13095 having pressure ratting PN -1.60 including fixing the same
with supply of required jointing materials like rubber insertion, MS
nuts & bolts, paint etc. and testing the joints with required water
pressure etc. all complete as per specification & direction of E.I.C.
Providing, fitting & fixing of following size cast iron double flanged
type dual plate Non return Valve as per IS- 5312 (Part 1): 2004
with ISI mark of pressure ratting PN-1.60 including fixing the same
with supply of required jointing materials like flanges, rubber
insertion, MS nuts & bolts, paint etc. and testing the joints with
required water pressure etc. all complete as per specification &
direction of Engineer-in-charge.
SITC of Gun metal chrome finished Ball valves with fittings of
396 4 screwed end type. 0.00 0.00
Supply,Installation,Testing & Commissioning of Pressure gauge of
0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable
size with all accessories as per direction of Engineer-in-charge.
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supply,Installation,Testing & Commissioning of Pressure Switch
with cut-off bronze ball valves with integral strainer & flare nut
(mixed ends) of suitable size with all accessories as per direction
of Engineer-in-charge.
Supply,Installation,Testing & Commissioning of stainless steel
strainer fabricated out of 1.6 mm thick stainless steel sheet Y
Stainer with 3 mm dia hloes with stainless steel flange as required.
402 C DOWN COMER SYSTEM 0.00 0.00
Supply,Installation,Testing & Commissioning of Stainless steel
Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single
headed , oblique type, as per IS :5290/93 and as per direction of
403 1 Engineer-in-charge Nos 2 8,130.20 0.00 16,260.40
Supply,Installation,Testing & Commissioning of SS short branch
pipe with 63 mm male inlet and 19 mm outlet nozzle, as per
404 2 IS:903 and as per direction of Engineer-in-charge. Nos 2 2,808.40 0.00 5,616.80
Supply,Installation,Testing & Commissioning of 63 mm NB and
15meter long RRL Fire Hose fitted with 63mm intstantaneous
405 3 stainless steel male & female SS coupling, complete by GI wire Nos 4 6,926.60 0.00 27,706.40
binding for Internal Hydrant as per direction of Engineer-in-charge.
Providing supply & fixing of MS Hose Box for of suitable
size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30
mtr long fire hose and a branch pipe, wall mounted type as per
direction of Engineer-in-charge.
Supply,Installation,Testing & Commissioning of Swinging pattern
wall fixing first aid hose reel made from MS sheet and waterways
and moving parts with rubber hose of 20 mm dia. and 30 mtrs.
long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585
Type-I., complete with all accessories as per direction of Engineer-
Providing, fitting and fixing of C.I. 25 MM single air relief valve with
stop cock confirming to IS:14845/2000 with ISI mark for water
works purpose including fixing the same with hydrant riser
408 6 including testing & commissioning the system etc. all complete as Nos. 1 1,699.20 0.00 1,699.20
per approved specification & direction of Engineer-in-charge.
Providing, fitting & fixing of 2-Way GM fire brigade connection
consisting of 63 mm dia instantaneous type male couplings with
built-in check valves, 150mm dia flanged outlet complete with
409 7 bolts, nuts and rubber insertions confirming to IS:904 with ISI mark Nos. 1 6,974.98 0.00 6,974.98
including testing & commissioning the system etc. all complete as
per apporoved specification & direction of EIC.
EXTINGUISHER SYSTEM
Supply,Installation,Testing and Commisioning of ISI marked
411 1 (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg Nos 4 9,086.00 0.00 36,344.00
with all accessories
Supply,Installation,Testing and Commisioning of ISI marked
(IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all
Fire buckets (FILLED WITH SAND) round bottom type enamel
painted, white inside & Red out side and Letter "FIRE" in black out
side and handle with mounting bracket.
SIGNAGES:-Providing and installing in position the following type Sqinch
of sign boards made out of 3mm thick flexyle photoluminescent
based glow in dark sheeting with luminous properties enclosed in
a weather proof Uvstabilized film with UV screen printing by
415 1 imported links pasted over3 mm thick cast acrylic from front side 200 21.24 0.00 4,248.00
with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use,
greenish yellow, glow visible upto 4-6 hr in total darkness.
Supply, Installation,Testing & Commisioning of Manual based
Addresable fire alarm control panel , fully networkable with each
loop capable of taking 99 devices, 8 line x 40 character alpha-
numeric liquid crystal display .The panel shall be soft addressable
type . The panel shall be able to give pin point location of all
fire/fault conditions. Further, the panel must be able to No. 1 40,710.00 40,710.00
automatically switch off respective control switches when ever any
alarm is triggered. The panel shall have integral SMF lead acid
batteries with sealed cells of 24 V capable of running for a
minimum of 8 hours with integral battery charger complete as
required and as per specification. The fire alarm panel shall be
Digitally signed by DIWAKAR
BoQ: INOVATION & INCUBATION CENTRE (G+1) BUILDING
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying, installing, testing and commissioning of Addressable
Manual Call Point with back box.
Supplying, installing, testing and commissioning of Analogue
Addressable Loop powered Sounder with strobe light.
Supplying, installing, testing and commissioning of 2C x 1.5 mm²,
armoured, single stand, outer sheathed, FRLS, PVC insulated
copper conductor cable confirming to specified IS standards
Supplying, installation, testing & commissioning of 2 zone,voice
alarm controller with USB, MP3 player (including 2 zone button
paging station) with seamless integration facility with main fire
421 1 alarm panel for voice evacuation complete as required. Nos. 1 65,724.82 0.00 65,724.82
Supplying, installation, testing & commissioning of digital audio
amplifier 250 Watt, 25V rms operating at 240 Volt AC Supply
422 2 complete as required. Nos. 1 46,680.80 0.00 46,680.80
Supplying, installation, testing & commissioning of ceiling/wall
mounted loud speaker, 3/15 Watt in ABS enclosure complete as
Supplying and drawing of speaker cable Single pair, 2-core, 1.5
424 4 sqmm in existing conduits Mtr. 150 76.70 0.00 11,505.00
Sub-Total of Fire fighting Works 6,46,153.84
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Civil Works 0.00 0.00
Earth work in excavation of foundation trenches in hard soil
including dressing of sides and levelling the bed up to the required
depth and depositing the excavated materials away from the work
1 1 site within 50m initial lead & 1.5m initial lifts with sundries & T&P
required for the work complete including cost of all labour,labour
cess,T&P,sundries etc. as directed by the Engineer in charge.
Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
ramming & watering with all leads & lifts including cost of all
labour,T&P completed as directed by the Engineer-in-charge.
Supplying and filling in foundation and plinth with good quality river
sand including watering, ramming with cost, conveyances,
royalties of all materials and cost of all labour with T&P required
5 3 for the work etc. complete as per specification & direction of 0.00
Engineer-in-charge
Providing & applying of pre constructional anti-termite treatment by
drilling 12mm dia holes at distance of 30cm @ junction of wall &
floor about 300mm apart deep enough to reach the soil below &
chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr
water) pumped these holes to soak the soil @ 1 ltr solution of each
hole as per manufactures specification & the holes should be
pluged the filling materials including cost of all materials,
labour,conveyance, T&P , all taxes and hire charges of
machinaries as per direction of Engineer-in-charg
Cement concrete of proportion (1:3:6) in foundation and floors
using 4cm size clean hard black crusher broken granite stone
metal of approved quality and from approved quarry including
hoisting, lowering and laying concrete in layers not exceeding 15
8 5 cm. (6") thick to the required level ramming, watering, curing etc. Cum 58.71 8812.12 5,17,359.68 0.00
complete including cost, conveyance, royalties of all materials with
all labour and T&P required for the work etc. complete in all
respect and as per the direction of the Engineer-in-charge.
Plain cement concrete (1:2:4) using 12mm size black hard crusher
broken granite chips of approved quality from approved quarry
including hoisting, lowering and laying concrete in layers, watering,
curing etc. complete including cost, conveyance, royalties of all
materials with labour,labour cess and T&P etc. required for the
work complete as per the direction of the Engineer-in-charge.
Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth
using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing
strength of not less than 75 kg./sqcm with dimensional tolerance ±
2% including splays cutting circular moulding chamfering and
corbelling and similar such type of works with all necessary
10 7 projections watering and curing after immersing the bricks in water Cum 21.08 6792.08 1,43,177.05 0.00
at least for six hours before use including cost, conveyance, and
royalties of all materials with all labour,labour cess and T & P
required for the work complete in all respect as per direction of
Engineer-in-Charge
Fly Ash brick masonry in cement mortar (1:6) in super structure
using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing
strength of not less than 75 kg./sqcm with dimensional tolerance ±
2% including splays cutting circular moulding chamfering and
corbelling and similar such type of works with all necessary
projections watering and curing after immersing the bricks in water
at least for six hours before use including cost, conveyance,
royalties and taxes of all materials with all labour,labour cess and
T & P required for the work complete in all respect as per direction
of Engineer-in-Charge
Fly Ash brick masonry in cement mortar (1:4) in super structure
using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing
strength of not less than 75 kg./sqcm with dimensional tolerance ±
2% including splays cutting circular moulding chamfering and
corbelling and similar such type of works with all necessary
projections watering and curing after immersing the bricks in water
at least for six hours before use including cost, conveyance,
royalties and taxes of all materials with all labour,labour cess and
T & P required for the work complete in all respect as per direction
of Engineer-in-Charge
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square cm.
in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
18 10 shuttering then after dismantling and removing debris from the 0.00 0.00
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
19 Ground Floor 0.00 0.00
21 b) Column up to plinth Cum 4.32 20715.61 89,491.43 0.00
23 f) Column above plinth Cum 9.07 20715.61 1,87,890.56 0.00
29 1st floor 0.00
30 a) Column above plinth :- Cum 9.07 23135.08 2,09,835.18 0.00
36 Terrace floor 0.00 0.00
37 a) Column above plinth :- Cum 3.67 26031.15 95,534.34 0.00
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor
steel of primary steel producers such as SAIL / TATA / RINL /
JINDAL STEEL / SHYAM STEEL/ SEL Tiger (grade Fe-500D) etc.
including bending, binding, welding and jointing if necessary and
tying the grills and placing in position as required for R.C.C. Work
and for providing fan hooks as required, hoisting, lowering, laying
41 11 including cost, conveyances of M.S. Rod or tor steel and binding 0.00 0.00
wires of 18 to 20 gauge and labour required for the work for
bending, binding and tying the grills in all floors with labour cess
etc. (payment will be made on standard weight of B.I.S. for M.S.
Rods or tor steel only) etc. complete as per specification &
direction of Engineer-in-charge.
Providing 12 mm thick cement plaster with cement mortar of mix
(1:6) with screened and washed sharp sand for mortar and
finished smooth to the rough surface of walls in all heights after
racking out joints including watering and curing, rounding of
45 12 corners, providing grooves where ever necessary with cost, 0.00 0.00
conveyance, royalties of all materials with cost of all labour,labour
cess, T&P, and scaffolding required for the work etc. complete in
all respect as directed by the Engineer in charge.
Providing 16 mm thick cement plaster with cement mortar of mix
(1:6) with screened and washed sharp sand for mortar and
finished smooth to the rough surface of walls in all heights after
racking out joints including watering and curing, rounding of
49 13 corners, providing grooves where ever necessary with cost, 0.00 0.00
conveyance, royalties of all materials with cost of all labour,labour
cess, T&P, and scaffolding required for the work etc. complete in
all respect as directed by the Engineer in charge.
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Providing 6 mm thick cement plaster with cement mortar of mix
(1:4) with screened and washed sharp sand for mortar and
finished smooth to R.C.C. work after closed deep chipping & slurry
treatment including watering and curing, rounding of corners,
53 14 providing grooves where ever necessary with cost, conveyance, 0.00 0.00
royalties of all materials with cost of all labour,labour cess, T&P,
and scaffolding required for the work etc. complete in all respect
as directed by the Engineer in charge.
Fixing granite tiles of approved dimension area above 0.4 sqm
(20mm thick) in floor, treads of steps and landing on 20mm thick
bed of cement mortar (1:4) jointed with neat cement slurry mixed
57 15 with pigment to match the shades of the tiles including rubbing and 0.00 0.00
polishing etc. complete with cost, conveyance, royalties and taxes
of all materials complete in all respects as per direction of
Engineer-in-Charge.
Fixing granite tiles of approved dimension area above 0.1 up to
0.4 sqm (10mm thick) in Dados, treads of steps and landing on
12mm thick cement mortar (1:3) jointed with neat cement slurry
mixed with pigment to match the shades of the tiles including
rubbing and polishing etc. complete with cost, conveyance,
royalties and taxes of all materials complete in all respects as per
direction of Engineer-in-Charge.
Providing full body matt finish vitrified tile flooring using vitrified
tiles having thickness of min 10mm conforming to IS 13755 of
1200x600 (shade to be decided as per Ama Hospital scheme)
(homogeneous) of premium quality in floors, treads on steps and
landings on 20mm thick bed of cement mortar of mix (1:4) laid in
proper slope and gradient with screened and washed sharp sand
for mortar and fixing with neat white cement slurry,grouting the
joints with neat white cement slurry mixed with required quantities
of pigments of approved make to match the shades of the vitrified
tile if required , watering and curing for 21 days, including cost,
conveyance, loading, unloading, royalties and taxes of all
materials, cost of all labour,Labour cess , sundries, T&P required
for the work, complete in all respect as per specification and
direction of Engineer-in-charge.
Providing, fitting, fixing vitrified tiles of premium grade having
thickness 8mm to 10mm confirming to IS 13756 of size 600mm x
600mm Plain (Ivory) as directed by Engineer-in-charge in dados
skirting and risers of steps on 12mm thick cement plaster (1:3)
66 18 jointed with neat cement slurry mixed with pigment to match the 0.00 0.00
shades of the tiles including rubbing and polishing etc. complete
with cost, conveyance, royalties of all materials all labour,labour
cess complete in all respects.
Supplying, fitting & fixing of 8-10 mm thick & size of 600x600 mm
Anti-skid vertified floor tile of with veilcraft (VC/FT ) shield(
Scratch free/stain free) with water absorption limit between
0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid
on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand)
69 19 and filling joints with white cement of approved quality including 0.00 0.00
cost of all materials, labour T&P etc. required for the work all
complete as per direction of the Engineer-in-charge (for New Work
Supplying, fitting & fixing of 600mm x 300mm Ceramic wall tiles
having thickness 6.5mm to 7.0 mm confirming to IS 13753 in
dadoes, skirting and risers of steps laid on 12 mm thick cement
mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed
72 20 with pigment to match the shades of the tiles etc. complete 0.00 0.00
including cost of all materials, labour T&P etc. required for the
work all complete as per direction of the Engineer-in-charge
Supplying, fitting and fixing vetrified Industrial tiles in floors of
premium grade having thickness 8mm to 10mm of size 300mm x
300mm confirming to IS 4457 with colour / printed series of
approved on 20mm thick bed of C.M. (1:4) including cost of all
materials, labour, T&P etc. required for the work in all respect as
directed by the Engineer in charge.
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Providing & Fixinng factory made 100% Solid WPC ( Wood
Polymer Composite ) - Door Frame 125 mm x 65 mm Single
Rebated, made from Wood Polymer Composite ( Single Extruded
Process ) material comparising of virgin PVC polymer of K Value
57-60 ( Suspension Grade ), Calcium Carbonate and Natural
Fibers ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic
additives fabricated with meter Joints after applying PVC solvent
Cement & screwed with full body treaded star headed screws
with approved quality of 30mm thick BWR block board pasted with
1mm thick sunmica on both side of approved design and quality
including cost of all door fittings and fixtures etc. complete in all
80 23 respect as per the direction of the Engineer-in-Charge. 0.00
Factory made single leaf rigid FRP(alternately called GRP)
sandwich composite door shutter of 32mm thick laminated with two
GRP skins with wood grain finish fabricated using UV-stabilised
Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped
Strand Mat (CSM) impregnated with orthopthalic palyester resin.
The thickness of the skins shall not be less than 3.00mm
Expanded Polystyrone(EPS) structural foam panel of 29mm
thickness and a density of 20kg/cu.mtr shall be used as core
material. Wooden reinforcements made of seasoned sal wood
block of cross section not less than 28mmx32mm and also
necessary sal wood reinforcements for fitting the metal fittings
such as tower bolts, aldrops, handles etc shall be provided. A
83 24 structural adhesive compatible with (EPS) foam shall be used for
bending the core material, the sal wood reiforcements and the
skins. The material and process for manufacturing the door
shutters shall conform to RV-TIFAC composites Design Centre's
standards and specifications and the door shutters tested in
conformation to IS: 4020-1998. The finish of door shutter will be
plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood
or any other colour using high quality pigments. Three heavy
whight mild steel butt hinges type-I(ISI marked) size 100mm are to
be fitted on one side of shutter with FRP frame of size 45x90mm.
Supplying and fixing of Powder coated 50-60 microns approved
colour of Aluminium 40mm Casement series Door Unit with
suitable aluminium extrude profiles. the system is designed to
accommodate 12mm clear toughened glass of make-Saint
gobain/AIS/Gardian/modi. the rate quoted inclusive of hardwares
like antilift,roller, Espag lock cum handle,epdm gaskets,T mullion
,Fly Mullion ,bottom adopter ,mid transom ,glazing clip for 12 mm
glass felt along with all accessories etc complete. the gap between
the wall and window will be filled with silicon weather sealant in the
outer side. Casement Door Outer frame - 40mm x 45.3mm Series
x 1.4mm thickness, Fly mullion - 44 x 60 mm x 1.4mm thickness, T
Mullion 40 x 78.4mm x 1.4mm thickness, Transom - 40.28 x 125.8
x 1.75 mm thickness, Bottom adopter - 34.6 x 26 x 1.5mm
thickness, including cost of all materials, all labour, sundries, T&P
etc. complete in all respect as per direction of Engineer-in-Charge
Supplying and installing UPVC- 3 tracks sliding windows and 2
sashes (shutters) with ss mesh sash dimension of 58 mm x 32 mm
and sash dimension of 61mm x 37mm for windows with corners
fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2
mm. The sash will be fitted with 5mm reflective toughened glass of
make - Saint gobain/AIS/Gardian/modi . The windows must be
installed complete with all kinds of ironmongery (including EPDM
gaskets,bridging wedges and glass packers) and with suitable
water draining system. Application of Silicon sealant from Inside /
Outside of Dowcorning / GE or equivalent including cost of all
materials, all labour, sundries, T&P etc. complete in all respect as
per approved drawing & direction of Engineer-in-Charge
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S.
gates, garage door, collapsible gates with top and bottom rails,
steel windows, critical frames for windows, stair case and parapet
railing made out of M.S Square bar/ flat including stair case hand
railing with 40mm. dia G.I.pipe etc. including painting two coats
92 28 over a coat of redoxide primer as per approved drawing and
design with cost of all materials & labour, labour cess, T&P,
sundries etc. complete in all respect as per specification &
direction of the Engineer-in-Charge.
Priming one coat with wall cement primer (water bound) to make
an even finished surface in all floors and heights to wall surface of
approved make and shade including sand papering, applying putty
wherever necessary & cost of scaffolding, staging charges with
cost, conveyance, cost of all labour,labour cess T&P etc. complete
as per the direction of the Engineer-in-charge.
Wall painting two coats with Antifungal weather coat paint (1st
quality) exterior grade of approved make & approved shade over a
coat of primer to make an even finished surface in all floors and
heights with all scaffolding and staging charges including cost,
100 30 conveyance, cost of all labours, T & P, sundries etc. as required
for the work complete in all respect as per the direction of the
Engineer-in-Charge.
Finishing plastered surfaces of walls with cement based wall putty
(Water based) duly approved by Engineer-in-Charge) and
finishing the surface smooth and even by sand papering to receive
painting in walls, at all heights with staging wherever necessary
104 31 with cost, conveyance, cost of all labour,labourcess, all T&P etc.
required for the work complete in all respect as per the direction of
the Engineer-in-charge.
Painting two coats with plastic emulsion paint with a approved
quality primer to make an even finished surface in all floors and
heights to wall surface of approved make and shade including
sand papering, applying putty wherever necessary & cost of
108 32 scaffolding, staging charges with cost, conveyance, cost of all
labour,labour cess, T&P etc. complete as per the direction of the
Engineer-in-charge.
Engineer-in-charge.
Painting two coat with approved synthetic enamel paint to new
wood work over a coat of Red oxide primer including cost,
conveyances, royalties, taxes of all materials and cost of all labour
112 33 with T&P required for the work etc. complete as per specification &
direction of Engineer in charge.
Painting two coat with approved synthetic enamel paint to new
iron work over a coat of Red oxide primer including cost,
conveyances, royalties, taxes of all materials and cost of all labour
115 34 with T&P required for the work etc. complete as per specification &
direction of Engineer in charge.
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying, fitting and fixing of Stainless steel of 304 grade in hand
railing using 50mm dia of 2mm thick circular pipe with Balustrade
of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless
square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair
case as per approved design and specification, buffing, polishing
etc with cost, conveyance, cost of all labour,labour cess, T&P etc.
required for the work complete in all respect as per direction of the
Engineer-in-charge.
Supply and Installation of System comprises of Semi unitized
extruded aluminum Structural Glazing wall panels comprising of
extruded Vertical Aluminium mullions and Horizontal transoms
(JINDAL/HINDALCO/EQUEVALENT ) with super Durable Powder
Coating finish of minimum 60 Microns confirming standards to
withstand wind pressure. The mullions and transoms are installed
on locations as indicated in the architectural drawings. The
framing members provide no structural support for the building and
the Structural Glazing wall is deemed to be a lightweight façade
which is intended to separate the external from the internal of the
building and provides natural light into the building. The curtain
wall system is designed to have internal drainage system within
the extruded sections with 6MM Blue toughened glass. Gaskets
are employed as water barrier between the aluminum gridwork and
the glazed sashframe, which are fully drained in the event of
leakage past the primary seal. The external grooves are covered
with application of backer rod with weather sealant of approved
make as indicated in the concept drawing. Fabricating and
supplying Mild Steel ( HDG coated ) Brackets to accommodate 3
Dimensional movement for achieving perfect verticality and proper
fixing of structural glazing system with the RCC/
masonry/structural steel framework of building structure, using
stainless steel (chemical/mechanical) anchor fasteners/ bolts,
Teflon separator to prevent bimetallic contacts with nuts and
washers etc. of stainless steel Grade 316, of the required capacity
and in required numbers
Supply and Installation of 14 mm GRG Tiles steppe edge ceiling
tile of size 595 x 595 x 14 mm on the edge & 7 mm in the center
having all edges encapsulated with chemical treated paint &
having densified tegular edge ,weight 5 kg/m2 having random
circular semi perforated in dual diameter / Random fissure semi
perforated in variable length which is suspended by using 0.3 mm
thick and 15 mm wide pre coated metal T 15 grid system. The
technical parameters are as follows : Core - GRG Silicate, Fire –
Class 1 & P , Acoustics – NRC 0.5,Climate (degree C, RH) – 50,
99, STC - 30, Termite resistance ,Light reflectance – 85 %,Green
(RC %) – 25, Hygiene (VoC, Clean room) – Low, , Load capacity
(Kg) - Antisag. The T 15 Grid system of 600 x 600 mm module
shall include wall angle(WA 15) with unequal flanges of size 14 x
20 x 3000 mm wide, length 3000 mm, 0.43 mm thick fixed along
the perimeter of wall with the help of nylon sleeves and suitable
fasteners at 300 mm centers. Then suspend the Main T15 (MT15
W36) having flange width 15 mm /24 mm , height 32/38 mm and
length 3600 mm thickness 0.30 mm from the soffit with help of
soffit cleat and wire at 1200 mm c/c. Cross T15 (CT15 W12) with
flange width 15 mm, height 32 mm and length 1200 mm is then
interlocked into the pre-cut slots in the Main T15 at 600 mm
centers in the direction perpendicular to the Main T15. Finally,
Cross T15 (CT15 W06) having flange width 15 mm, height 32 mm
and length 600 mm are then interlocked into the pre cut slots in the
1200 mm Cross T15 at 1200 mm centers and in direction parallel
to the Main T15. GRG Tile of size 595 x 595 x 14 mm thick shall
be placed into the grid size of 600 x 600 mm. Ensure arrow marks
behind panels are oriented in one direction to achieve uniform
shade. Test certificate will be submitted after procurement of
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Providing and laying water proofing treatment in sunken portion of
WCs, bathroom etc., by applying cement slurry mixed with water
proofing cement compound consisting of applying : (a) First layer
of slurry of cement @ 0.488 kg/sqm mixed with water proofing
cement compound @ 0.253 kg/ sqm. This layer will be allowed to
air cure for 4hours. (b) Second layer of slurry of cement @ 0.242
128 38 kg/sqm mixed with water proofing cement compound @ 0.126 0.00
kg/sqm. This layer will be allowed to air cure for 4 hours followed
with water curing for 48 hours. The rate includes preparation of
surface, treatment and sealing of all joints,corners, junctions of
pipes and masonry with polymer mixed slurry.
Providing 2.5cm thick Grading Concrete over roof slab with
cement concrete (1:2:2) using 6mm size black hard granite
crusher broken chips and screened & washed sharp sand for
mortar and finished smooth to the rough surface of slab including
131 39 watering and curing with cost, conveyance, royalties of all
materials with cost of all labour, labour cess and T&P required for
the work etc. complete in all respect as directed by the Engineer in
Waterproofing application:- Providing and application of two
component polymer modified flexible cementitious waterproofing
coating at a thickness of 1.5 -2.5 mm The membrane should have
Elongation equal or more than: 30%
Crack Bridging ability : Up to 1 mm
Adhesive strength: 1.0 N/mm² @ 28d
Tensile elongation: 60% @ 20°C
Shore A Hardness >85 (between 3 - 7 days)
etc. as per direction of E.I.C (For longer span, in terrace panel of
4m*4m should be done by groove cutting, and filling with PU
135 Sub-Total of Civil Works TOTAL 1,36,09,458.08 34,43,102.88
136 DRAINAGE WORKS.
Earth work in excavation of foundation trenches in hard soil
including dressing of sides and levelling the bed up to the
required depth and depositing the excavated materials away
137 1 from the work site within 50m initial lead & 1.5m initial lifts with
sundries & T&P required for the work complete including cost of
all labour,labour cess,T&P,sundries etc. as directed by the
Engineer in charge.
Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
ramming & watering with all leads & lifts including cost of all
labour,T&P completed as directed by the Engineer-in-charge.
Supplying and filling in foundation and plinth with good quality
river sand including watering, ramming with cost, conveyances,
140 3 royalties of all materials and cost of all labour with T&P required Cum 15.17 1595.71 24,206.98
for the work etc. complete as per specification & direction of
Engineer-in-charge
Cement concrete of proportion (1:4:8) in foundation and floors
using 4cm size clean hard black crusher broken granite stone
metal of approved quality and from approved quarry including
hoisting, lowering and laying concrete in layers not exceeding
141 4 15 cm. (6") thick to the required level ramming, watering, Cum 15.17 8335.87 1,26,455.21
curing etc. complete including cost, conveyance, royalties of all
materials with all labour and T&P required for the work etc.
complete in all respect and as per the direction of the Engineer-
Providing, lifting, hoisting and laying Reinforced cement
concrete of M-25 grade as per approved designs and drawings
having a minimum compressive strength (in work test) 250 Kg.
/ Square cm. in 15 cm. cubes at 28 days after mixing and test
conducted in accordance with I.S. 516 using 12 mm. to 20 mm.
size black hard crushed broken granite stone chips and screened
and washed sharp sand for mortar of approved quality from
approved quarry, washed and cleaned ( 20mm. size chips not
to exceeds 25 % ) to be mixed in concrete mixture with Portland
slag cement (PSC) including hoisting, lowering, laying and
compaction concrete by using vibrators, watering and curing for
142 5 28 days, centering and shuttering then after dismantling and
removing debris from the work site and finishing the exposed
surface smooth providing grooves or beads wherever necessary
including cost, conveyance, loading, unloading, royalties and
taxes of all materials and cost of all labours, sundries, T & P
required of the work etc. complete in all respect as directed by
the Engineer-in-Charge. But excluding cost and conveyance of
M.S. rods or Tor steel and binding wires and labour charges for
straightening, cutting, bending etc. of M.S. rods or tor steel
tying the grills and placing in proper position.
143 a Drain Bottom slab Cum 12.30 9780.08 1,20,294.93
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying Cutting, straightening coiled or bent up M.S. Rod or
tor steel of primary steel producers such as SAIL / TATA / RINL
/ JINDAL STEEL / SHYAM STEEL/ SEL Tiger (grade Fe-500D) etc.
including bending, binding, welding and jointing if necessary
and tying the grills and placing in position as required for R.C.C.
Work and for providing fan hooks as required, hoisting,
lowering, laying including cost, conveyances of M.S. Rod or tor
steel and binding wires of 18 to 20 gauge and labour required
for the work for bending, binding and tying the grills in all floors
with labour cess etc. (payment will be made on standard weight
of B.I.S. for M.S. Rods or tor steel only) etc. complete as per
specification & direction of Engineer-in-charge.
147 Sub-Total of Internal Drainage Works TOTAL 11,69,666.66 9,91,240.00
148 INTERNAL ROAD
Earthwork in excavation in hard soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre
lift and stacking the soil upto a lead of 100 metre and including
149 1 dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
Filling at all depth with available excavated earth (excluding
rock) in trenches, plinth, sides of foundations etc. in layers not
151 2 exceeding 15cm in depth: consolidating each deposited layer by 80.40 181.48 14,591.31
ramming and watering complete (lead upto 100m) as directed
by the Engineer-In-charge. Cum
Supplying of filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools,
taxes etc., all complete as per the specification and direction of
Engineer-In-charge. Cum
Loosening levelling & compacting original ground suppourting
embankment to facilitate a placement of 1st layer of
embankment up to a depth of 150mm mixed with water at OMC
& then and then compacted by rolling as per Clause 300.20 for
embankment construction as per Clause No- 305.3.4 of MoRTH
specifiction. Cum
Providing close graded granular subbase with Grading-lll
Providing and laying 80 mm thick factory made cement concrete
interlocking paver block of M-40 grade made by block making
machine with storng vibratory compaction of approved size,
155 6 design & shape, laid in required colour and pattern over and 300.00 717.91 2,15,373.60
including 75mm thick sand filling.as per drawing, specification
and direction of Engineer-In-charge.
Construction of cement concrete kerb with top and bottom width
115 and 165 mm respectively, 250 mm high in M 20 grade PCC
on M-10 grade foundation 150mm thick, foundation having
50mm projection beyond kerb stone, kerb stone laid with kerb
laying machine, foundation concrete laid manually, all complete
as per clause 408 Rmt
Providing & Painting with synthetic enamel paint of approved
brand and manufacture to give an even shade as per the
157 8 instruction of Engineer-In-Charge at all floors and all heights 80.00 222.78 17,822.72
including all material & labour complete.
158 Sub-Total of Internal Road Works TOTAL 6,83,132.47
159 Plumbing Works
160 A. SUPPLY & DRAINAGE PIPING & FITTINGS
161 WATER SUPPLY.
Supplying, installing, fixing, jointing, testing and commissioning of
approved make. Chlorinated Polyvinyl Chloride pipes (CPVC)
SDR.11 pipes confirming to ASTM standards with necessary
fittings for inetrnal toilet water supply upto 50 dia , and above
50mm dia pipe schedule 80 with fitting shall be schedule 80
ASTM IPS. The fittings and specials such as tees,
elbows,couplers, bends, enlargers etc.,m with CPVC brass
threaded combination / transition specials such as male adapters
brass threaded female adapters, brass FPT Tee, Brass FPT elbow
etc., where connection with metal is to be made including
necessary drilling holes, chasing walls and making the same good
162 1 in cement martor 1:1 restore the same original condition neately as 0.00 0.00
directed by the Engineer in-charge. Joints to be made with CPVC
solvent cement up to 50mm dia as per ASTM D-2846 and above
50mm dia primer P-70, and solvent confirming to ASTM F-4931 /
724 All exposed pipe shall be painted with latex paint. (for shafts,
basement ceiling ringmain Terrace & PRM).The rate shall include
necessary GI supports, GI grip bolts, angle brackets, hangers,
supports as with suitable GI U-clamps, bolts, nuts and washers
etc., The clamps shall be painted with two coats of enamel
(approved) paint over a coat of primer etc., complete
163 1.1 GROUND FLOOR
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
25 mm dia C-PVC pipe SDR.11
Providing all materials, labour, T&P for fitting & fixing of following
CPVC Ball Valves(CTS Sockets) confirming to IS-15778 with ISI
mark as per ASTM D-2846 in all floor & fixing with the pipes after
cutting the pipes to required shape & size including wastage etc.
170 2 of following nominal diameter, all complete including testing the 0.00
joints with required water pressure.The cost inclusive of
transportation scaffolding etc. all complete as per specification
excluding GST and direction of Engineer-in-charge.
171 a 25 mm dia CPVC ball valve Each 8 637.78 5,102.20 0.00
172 b 32 mm dia CPVC ball valve Each 5 816.78 4,083.92 0.00
Supplying, installing, testing and commissioning butterfly valves
with standard lever confirming to IS 13039 with necessary
173 3 connecting fittings like flanges ,nuts and bolts etc., complete. 65 Each 1 4796.35 4,796.35 0.00
174 DRAINAGE PIPE 0.00
Supplying all materials, labour, T&P and cutting holes through
existing brick work including making good the damages in cement
mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and
175 4 fittings etc. all complete as per P.H. specification and direction of 16 1,248.64 0.00
Engineer-in-charge. 250 mm thick wal
Supplying all materials, labour, T&P and cutting hole in R.C.C
floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C
176 5 pipes and fittings etc and repairing the holes after insertion of 14 3,778.12 0.00
pipes etc with cement concrete (1:2:4 ) including finishing
complete so as to make it leak proof as per direction of the
Engineer-in-charge.
Supplying, fitting and Outing of PVC pipes as per
(IS:4985-2000) with heavy duty solvent cement (manufacture's
made) joint for basin and sink waste Class-3 (6 kg/sqcm) with
necessary fittings like bends, tees, reducers, sockets etc. &
177 6 specials viz. MS clamp as per design, screws with washer 0.00
includuing cutting holes in floor & walls & making good the
same, cutting chases & filling the same with PCC (1:2:4) & then
cement morter (1:6)
Supplying, fixing and testing PVC soil, waste, Rain and vent pipes
(SWR) supreme confirming to IS13592 : 2013, type B with rubber
ring/Solvent (confirming toIS5382) joint inclusive of allnecessary
specials like bends, tees,offsets, door bends, junctions, cowls,
etc.,laid underfloor/ fixed on walls,and in pipe shafts etc.,
180 7 complete.The rate shall include necessary GI supports, GI grip
bolts, angle brackets, hangers, supports as with suitable GI U-
clamps, bolts, nuts and washers etc., The clamps shall be painted
with two coats of enamel (approved) paint over a coat of primer
etc., complete.
Providing ,fixing , testing and commissioning of approved make
183 8 PVC vent cowl with necessary accessories etc., complete
185 B. SANITARY FIXTURES.
Supplying all materials, labour, T&P and fixing the following
vitreous china Wash Down Water Closet (European type W.C.
pan) with integral 'p' or 's' trap to the floor with wooden plug and
chromium plated pedestal screws including jointing the trap with
soil pipe in cement mortar (1:1) fixing plastic seat and cover for
wash down water closet with chromium plated brass hinges and
186 1 rubber buffers including polishing etc all complete as per Each 12 6679.98 80,159.76
specification and direction of the Engineer-In-Charge. (EWC with
Wall Hung Cistern, Drainage L Bend Pipe, Gasket and Installation
Kit with PP normal close seat cover, Hinges, Fixing Accessories
and Accessories set, Size: 350x480x395 mm, STrap)
Supplying all materials, labour, T&P and fixing Health Faucet
complete with Chromium plated brass brackets fixed to wooden
187 2 plugs with Chromium plated brass screws as per specification and
direction of the Engineer-In-Charge.
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long
Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) Each 14 2608.39
Supplying all materials, labour, T&P and fixing standard sized Two
way Bib cock etc complete including cutting the wall and making Each
Supplying all materials, labour, T&P and fixing standard sized
Long way body bib cock etc complete including cutting the wall
and making good the damages, including cost of all materials
190 4 complete as per PH specification complete as per direction of Er-in- 14 2315.04 32,410.59
charge. 15mm dia CP Two way bib cock with Flange.
Supplying all materials, labour, T&P and fixing standard sized
concealed stop cock etc complete including cutting the wall and
making good the damages, including cost of all materials complete
191 5 as per PH specification complete as per direction of Er-in-charge. 14 1698.37 23,777.24
15mm dia CP Two way bib cock with Flange.
Supplying all materials, labour, T&P and fixing standard sized
Chromium Plated brass Towel Rail complete with Chromium
Plated brass brackets fixed to wooden plugs with Chromium
Plated brass screws as per specification and direction of the
Engineer in charg
C.P. Soap Dish holder.
Supplying all materials, labour, T&P and fixing standard sized
Robe Hook of complete with all as per specification and direction 14 924.61
of the Engineer in charge.
Supplying all materials, labour T&P and fixing of Under Counter
wash basins in all floor of approved quality including cutting the
walls & floor and making good the damags with cement concrete
196 10 e.t.c including all tsxes,duties,transportation e.t.c. All complete as
per specification and direction of the Engineer-In-Charge.
190X550X430 MM Wash Basin
Supplying all materials, labour T&P and fixing of Waste coupling
198 11 32 mm size Half thread with 80mm height (Half Threaded) 11 728.77 8,016.45
Supplying all materials, labour, T&P and fixing mirror of superior
glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed
to wooden plugs with CP screws and washers complete as per
specification and direction of the Engineer-in-charge. 11 970.90 10,679.94
600mmx450mm size B.E.mirror
Supplying all materials, labour, T&P and fixing standard sized pillar
cock of Hindware/Jaquar/Parryware of approved make etc
complete including cutting the wall and making good the damages,
200 13 including cost of all materials complete as per PH specification 11 2197.16 24,168.76
and direction of Engineering-in-charge. 15mm dia fus Jaquar,Cat
Supplying all materials, labour, T&P and fixing standard sized
Chromium Plated soap dispenser complete with Chromium Plated
brass brackets fixed to wooden plugs with Chromium Plated
201 14 brass screws as per specification and direction of the Engineer in 5.5 5298.79 29,143.35
charge. soap dispenser jaquar ACN-1137N
Supplying all materials, labour, T&P and fixing standard sized
15mm dia angular Stop cock complete including cutting the wall
and making good the damages, including cost of all materials
202 15 complete as per PH specification complete as per direction of Er-in- 26 1471.46 38,257.96
charge. 15mm dia CP angle stop cock with wall flange .jaquar,Cat
Matrix Set-1 (Wash Basin 46x36 cm with one pair mounting
brackets, EWC & cistern complete with fittings & seat cover, one
203 16 no hinged rail 76 cm and 4 nos of grab rail 60cm) 2 76546.60 1,53,093.20
Overhead shower 120 mm Round shape Multi Flow (ABS Body)
chrome plated with Gray Face Plate)with Rubit Cleaning System.
15 mm dia C.P revolving shower with arm
Supplying and installing ARISTO Plastic Dustbin Black 120 L with
Lid & Wheel, weight-7.5kg,Size (HxWxD-980x490x550mm),
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying, fixing and testing PVC muilty floor trap without SS
frame and cover 75mm dia outlet fixed on a bed of cement
concrete with (Heavy duty type) etc., complete
Supplying, fixing and testing PVC Nahani floor trap without SS
frame and cover 75mm dia outlet fixed on a bed of cement
concrete with (Heavy duty type) etc., complete.
209 22 Supplying, fixing SS floor trap grating . 21 548.70 11,522.70
210 A.II EXTERNAL P.H. & SANITARY WORK.
Supplying, fixing and testing PVC soil, waste, Rain and vent pipes
(SWR) supreme confirming to IS13592 : 2013, type B with rubber
ring/Solvent (confirming toIS5382) joint inclusive of allnecessary
specials like bends, tees,offsets, door bends, junctions, cowls,
etc.,laid underfloor/ fixed on walls,and in pipe shafts etc.,
211 1 complete.The rate shall include necessary GI supports, GI grip
bolts, angle brackets, hangers, supports as with suitable GI U-
clamps, bolts, nuts and washers etc., The clamps shall be painted
with two coats of enamel (approved) paint over a coat of primer
etc., complete.
Earthwork in excavation in all types of soil for 200mm dia site
leveling, and forming the bottom surface foundation, pits, trenches
and other civil works upto and including 1.5metre depth and
stacking the soil upto a lead of 100 metre and including
dewatering, removing slush, shoring and strutting (as required), 80 259.60 20,768.00 0.00
complete as per specification and as directed by the Engineer-In-
Supplying all materials, labour, T & P and constructing Gully Trap
chamber of the following inside size with 8 cm thick R.C.C. precast
cover slab in CC (1:2:4) mix using 12mm size h.g. chips,
foundation concrete (1:4:8) using 40mm size h.g. metal on bed
aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside
215 3 12mm thick cement plastering (1:3) finished with a floating coat of 0.00
neat cement including fixing 100mm x100mm size gully trap,
150mm x150mm C.I gratig etc. all complete as per aproved
drawing, specification and direction of Engineer-in-charge.
216 a 300mmx300mm with RCC cover Each 7 2220.05 15,540.36
Supplying all materials, labour, T & P and constructing of
Inspection chamber of the following inside size with 8 cm thick
R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g.
chips, foundation concrete (1:4:8) using 40mm size h.g. metal on
bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside
217 4 12mm thick cement plastering (1:3) finished with a floating coat of
neat cement including fixing 100mm x100mm size gully trap,
150mm x150mm C.I gratig etc. all complete as per aproved
drawing, specification and direction of Engineer-in-charge.
Inside size 900mm x800mm x450mm with Cast iron Manhole Each
OPEN WELL SUBMERSIBLE PUMPS FOR DOMESTIC WATER
219 TRANSFER FROM UGR TO OHR 0.00
Supply, installation, testing and commissioning Open well
submersible pump of required drive (Motor HP), having
discharge capacity and pumping head as described below with all
electrical accessories viz.main switch and starter, auto on/off
220 1 system with float arm (with fixed or flexible arm), over load 0.00 0.00
protection relay, power cable and control cable from main switch
and starter with auto on-off with dry running protection to
respective motors, earthing having required M.S. galvanised
supporting stay/ clamp etc. complete operational.
221 a RPM : 2900 (LOCATED AT UGR ). EACH 1 97,296.90 0.00
222 A. 10 KLD DOMESTIC WATER UGR TANK AND PUMP HOUSE 0.00
Earthwork in excavation in hard soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre lift
and stacking the soil upto a lead of 100 metre and including
223 1 dewatering, removing slush, shoring and strutting (as required), 0.00
complete as per specification and as directed by the Engineer-In-
Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
226 2 ramming & watering with all leads & lifts including cost of all 16.09 2,920.08 0.00
labour,T&P completed as directed by the Engineer-in-charge.
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying and filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools,
227 3 taxes etc. all complete as per the specification and direction of 1.52 1595.71 2,425.49 0.00
Engineer-In-Charge.
Providing and laying plain cement concrete 1:3:6 (1 cement: 3
sand: 6 stone agregate 40mm nominal size) as levelling course
228 4 in foundation and plinth etc. including tempering, curring 1.52 8812.12 13,394.43 0.00
,shuttering etc.complete all depth and height
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square cm.
in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
a) Footings :- 3.04
Cutting, straightening coiled or bent up M.S. Rod or tor steel of
SAIL/ TATA / RINL (VIZAG) make including bending, binding,
welding and joining if necessary and tying the grills and placing in
position as required for R.C.C. Work and for providing fan hooks
as required, hoisting, lowering, laying including cost, conveyances,
taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge
and labour required for the work for bending, binding and tying the
grills in all floors (Linear measurement will be taken and quantity
will be calculated basing on the standard weight of B.I.S. for M.S.
Rods or tor steel only. Wastage if any, including weight of binding
wire will not be considered for measurement) etc. complete as per
specification & direction of Engineer-in-charge.
Providing & applying SikaTop seal 109 hi, Two Component Acrlic
Cementations waterproofing coating over the injected & prepared surface
@ 2.2 Kg/sqm in two coats at the dry areas as per the site condition. Lose
234 7 Plaster to be removed up to the mother substrate present if any in SQM 52.5 649.00 34,072.50
retaining wall prior to the application of waterproofing coating.
12mm cement plaster on external RCC/brick surfaces in cement
mortar 1:4 (1 cement : 4 coarse sand) with a floating coat of neat
235 8 cement punning including necessary scaffolding, curing etc. all SQM 35.00 232.58 8,140.23
complete at all floors and all heights.
Supplying all materials labour, T&P and fitting and fixing RCPC
Cover all compete as per specification and direction of the
Engineer in charge. 2.00 1847.29 3,694.58
( DOMESTIC OHT TANK 5 KLD AND FIRE OHT TANK-5 KLD)
Providing, lifting, hoisting and laying Reinforced cement concrete of M-
25 grade as per approved designs and drawings having a minimum
compressive strength (in work test) 250 Kg. / Square cm. in 15 cm.
cubes at 28 days after mixing and test conducted in accordance with I.S.
516 using 12 mm. to 20 mm. size black hard crushed broken granite
stone chips and screened and washed sharp sand for mortar of approved
quality from approved quarry, washed and cleaned ( 20mm. size chips
not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag
cement (PSC) including hoisting, lowering, laying and compaction
concrete by using vibrators, watering and curing for 28 days, centering
and shuttering then after dismantling and removing debris from the work
site and finishing the exposed surface smooth providing grooves or beads
wherever necessary including cost, conveyance, loading, unloading,
royalties and taxes of all materials and cost of all labours, sundries, T & P
required of the work etc. complete in all respect as directed by the
Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or
Tor steel and binding wires and labour charges for straightening, cutting,
bending etc. of M.S. rods or tor steel tying the grills and placing in proper
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Cutting, straightening coiled or bent up M.S. Rod or tor steel of
SAIL/ TATA / RINL (VIZAG) make including bending, binding,
welding and joining if necessary and tying the grills and placing in
position as required for R.C.C. Work and for providing fan hooks
as required, hoisting, lowering, laying including cost, conveyances,
taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge
243 2 and labour required for the work for bending, binding and tying the 13.38 10682.42 1,42,930.81 0.00
grills in all floors (Linear measurement will be taken and quantity
will be calculated basing on the standard weight of B.I.S. for M.S.
Rods or tor steel only. Wastage if any, including weight of binding
wire will not be considered for measurement) etc. complete as per
specification & direction of Engineer-in-charge.
12mm cement plaster to out side of brick surfaces with cement mortar
244 3 of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, 30.54 255.47 7,802.05 0.00
curing etc. all complete at all floors and all heights.
12mm cement plaster on external RCC/brick surfaces in cement mortar
1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement
punning including necessary scaffolding, curing etc. all complete at all
floors and all heights. SQM
Priming one coat with wall cement primer (water bound) to make an
even finished surface in all floors and heights to wall surface of approved
make and shade including sand papering, applying putty wherever
246 5 necessary & cost of scaffolding, staging charges with cost, conveyance, 39.70 102.19 4,056.86 0.00
taxes of all materials, cost of all labour,labour cess T&P etc. complete as
per the direction of the Engineer-in-charge.
Painting two coats with approved anti-fungal weather seal paints
(ISI) of approved colour, shade on wall surface over a coat of wall
primer(ISI) water bound including sand papering, polishing the
247 6 surface, cost, conveyances of all materials and cost of all 30.54 3,910.04 0.00
labour,labour cess with T&P etc, complete as per specification &
direction of Engineer-in-charge. Sqm 128.03
2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm &
down grades size hard granite crusher broken chips on new work
in Terrace Floor
249 C SEPTIC TANK
Earth work in excavation of foundation in all kinds of soil within
50m initial lead and 1.5m initial lift including rough dressing &
breaking clods to maximum 5cm to 7cm and laying in layers not
250 1 exceeding 0.30m in depth and as per direction of the Engineer-in- 24.71 8,888.41 0.00
Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in
251 2 all kinds of embankments and road works and ordinary earthwork 4.94 1,894.29 0.00
in general. Cum 383.38
Excavation of foundation in laterite rock or any hard rock (other than
granite or disintegrated rock) removed by chiselling including dressing
252 3 and levelling the bed not exceeding 1.50 mtr. in depth and depositing the 11.53 2,368.26 27,306.04 #REF!
soil within initial lead of 50 mtr. and as per specification approved by the
Department. Cum
Supplying all materials, labour, T&P and filling in foundation and plinth
with sand well watered and rammed including conveyance of all
materials to worksite, payment of royalty, taxes etc.all complete as per
direction of the Engineer in charge. Cum
Supplying all materials, labour, T&P and providing cement
concrete (1:3:6) with 4cm size hard granite metal including
254 5 watering, curing, conveyance of all materials to worksite, payment 3.29 8,812.12 28,991.88
of royalty, taxes etc all complete as per specification and direction
of the Engineer in charge Cum
Supplying all materials, labour, T&P and providing 6mm thick cement
plaster (1:4) on RCC work including watering, curing, conveyance of all
materials to worksite, payment of royalty, taxes etc all complete as per
255 6 specification and direction of the Engineer in charge 39.68 257.95 10,235.38
Supplying all materials, labour, T&P and providing cement punning
including watering, curing, conveyance of all materials to worksite,
256 7 payment of royalty, taxes etc all complete as per specification and 44.96 48.38 2,175.16 #REF!
direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth
centering and shuttering for R.C.C works including false work and
257 8 dismantling them after casting including conveyance of all materials to 0.00 0.00
worksite, payment of royalty, taxes etc all complete as per specification
and direction of the Engineer in charge
258 a R.C.C floor and roof slabs up to 4.30m height Sqm 10.05 899.28 9,037.74
259 b R.C.C beams,columns,girder and bressmer etc. Sqm 70.44 1421.31 1,00,117.08
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying all materials, labour, T&P and providing M.S
reinforcement for R.C.C work including cutting, bending, binding,
and tying the grills and placing in position including cost of binding
260 9 wire 18 to 20 gauge, conveyance of all materials to worksite, 14.25 10601.47 1,51,071.00
payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement
concrete (1:1:2) with 12mm size hard broken granite chips for
R.C.C works including hoisting, laying, watering, curing,
conveyance of all materials to worksite, payment of royalty, taxes
etc all complete as per specification and direction of the Engineer
in charge Cum 9339.58
Supplying all materials, labour, T&P and providing cement
concrete (1:2:4) with 12mm size hard broken granite chips
262 11 including watering, curing, conveyance of all materials to worksite, 0.8 10652.69 8,522.15
payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge Cum
Supplying all materials, labour, T&P and providing 12mm thick
cement plaster (1:4) on brickwork including watering, curing,
263 12 conveyance of all materials to worksite, payment of royalty, taxes 5.28 257.95 1,361.97
etc all complete as per specification and direction of the Engineer
Supplying all materials, labour, T&P and providing brick work with
Fly ash bricks having crushing strength not less than 75kg/cm²
with dimensional tolerance ± 8 percent in cement mortar (1:4)
264 13 including watering, curing, conveyance of all materials to worksite, 0.6 7066.08 4,239.65
payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge
Supplying all materials, labour, T&P and making MS step iron in
20mm diameter MS steel bars and fixing into walls of man
265 14 hole/septic tank duly embedded in cement concrete (1:3:6) 6 333.70 2,002.22
complete as per specification and direction of the Engineer in
Filling in foundation and plinth with excavated materials, moorum
266 15 including watering and ramming as directed by the Engineer in 9.84 177.59 1,747.49
Supplying all materials, labour,T&P and providing 25mm thick
grading concrete (1:2:2) on roof slab with 6mm size hard granite
chips on new work including watering, curing, conveyance of all
materials to worksite, payment of royalty, taxes etc all complete as
per specification and direction of the Engineer in charge
upplying all materials, labour, T&P and providing shoring and
shuttering foundation trenches, pits etc with close wooden planks
268 17 or sheets shuttering etc all complete as per direction of the 44.01 385.15 16,950.54
Engineer in charge.
269 a Dewatering with 5 H.P diesel engine pump during excavation per hour 30 69.62 2,088.60
Supplying all materials, labour, T&P and providing, fitting and fixing
U-PVC SWR Tee in wall including filling the recess with cement
concrete (1:3:6) with 12mm size h.g chips all complete including
270 18 watering, curing, conveyance of all materials to worksite, payment 2 284.14 568.29
of royalty all complete as per specification and direction of the
Engineer in charge
160mm U-PVC plain Tee Each
Supplying all materials, labour, T&P and constructing vent base as
per P.H.D specification etc all complete. Each
Supplying all materials, labour, T&P and fitting and fixing U-PVC
SWR soil waste ventilating pipes and fittings of the following
outside diameter conforming to ISI No 13592/1992 to walls with
nails, bobbins and wooden plugs or laying in trenches including
272 20 jointing with supply of approved rubber lubricant by non-heat
application method/as per manufacturer's specification, testing,
earthwork in excavation in all kinds of soil and refilling of trenches
as per specification and direction of the engineer in charge.
273 a 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) Mtr 2.2 585.63 1,288.39
274 b 110mm U-PVC cowl Each 1 68.68 68.68
275 D SOAK PIT
1 Earthwork in excavation in all types of soil for site
leveling, foundation, pits, trenches and other civil
works upto and including 1.5metre lift and stacking the
276 soil upto a lead of 100 metre and including dewatering,
removing slush,shoring and strutting (as required),
complete as per specification and as directed by the
Engineer-In-Charge.
Filling at all depth with available excavated earth
(excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 15cm in depth:
consolidating each deposited layer by ramming and
watering complete (lead upto 100m) as directed by the
Engineer-In-charge. Cum
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying of filling sand in foundation and over areas
including watering,ramming, consolidating and
dressing, labours, tools, taxes etc., all complete as per
the specification and direction of E.I.C. Cum
Providing and laying plain cement concrete 1:3:6 (1
cement: 3 sand: 6 stone agregate 40mm nominal
size) as levelling course in foundation and plinth etc.
including tempering, curring ,shuttering etc.complete
all depth and height.
Brick work with Fly Ash. Bricks in cement mortar (1:6)
in foundation having crushing strength not less than
75.00 kg/cm2 immerging the bricks in water not less
than six hours before use in masonary. Cum
Providing, lifting, hoisting and laying Reinforced cement
concrete of M-250 grade as per approved designs and
drawings having a minimum compressive strength (in
work test) 250 Kg. / Square cm. in 15 cm. cubes at 28
days after mixing and test conducted in accordance
with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and
washed sharp sand for mortar of approved quality from
approved quarry, washed and cleaned ( 20mm. size
chips not to exceeds 25 % ) to be mixed in concrete
mixture with Portland slag cement (PSC) including
hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days,
283 8 centering and shuttering then after dismantling and
removing debris from the work site and finishing the
exposed surface smooth providing grooves or beads
wherever necessary including cost, conveyance,
loading, unloading, royalties and taxes of all materials
and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the
Engineer-in-Charge. But excluding cost and
conveyance of M.S. rods or Tor steel and binding wires
and labour charges for straightening, cutting, bending
etc. of M.S. rods or tor steel tying the grills and placing
in proper position.
Supplying, straightening, cutting, bending, placing in
position and binding reinforcement steel work in
RCC/reinforced brick works as per drawing and
specification including preparation of respective bar 1.05 10601.47
bending schedule and binding ( Binding wire to be
used as per the IS code) etc. all complete as per
direction of Engineer-in-charge.Cold Twisted bars,
Thermo-Mechanically-treated bars. Qntl
286 E C. BORE WELL (for 1 nos bore well)
Construction of 1 no production wells including scientific source
finding through consolidated and unconsolidated rock with down
287 1 the hamer drilling rig or combination rig with pvc pipe and
installation of submersible pump set with all acessories
Labour for drilling a perfectly vertical bore hole of specified dia for
a specified depth below ground level through consolidated and
unconsolidated rock with down the hole hammer drilling rig or
combination rig as required to suit the site condition as per the
direction of the engineer in charge including use of own rig with its
accessories ,tools and plant and consumables etc for lowering of
200mm/150mm dia G.I.P.V C/M.S casing pipes for housing fitted
288 2 with socket and with or without well screen as for the necessity for
soft ,medium,hard and boulder formation( G.I/P.V.C/M.S casing
pipes if required to prevent collapse of overburden is to be
provided by the contractor including lowering and withdrawing
after completion of the tube well) 200mm dia to 400mm dia in
overburden portion including packing of gravel supplied by the
contractor for 400mm dia bore only
289 3 Drilling of 200mm dia bore MTR 60 934.32 56,059.44
290 #REF! Drilling of 150mm dia bore MTR 60 934.32 56,059.44
Lowering the following size of G.I/P.V.C/M.S housing pipes with or
without slotted pipes as per the necessity form ground level up to
45.00m depth and fitted and fixed up in perfectly vertical position
including cutting and threading of pipes and dotted pipes and
291 #REF! supplying and fixing all jointing materials, tools and plant etc all
complete and keeping the top of casing pipe threaded including
plugging tube wells to prevent entry of foreign materials
292 #REF! Lowering of 200mm dia P V C casing pipes MTR 60 216.29 12,977.64
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having
threads in accordance with DIN 2999 part-1/DIN-42225 PART-II
specification length of pipe (laying length) will be 3 mtrs.The pipes
shall be supplied with both external threaded with free socket. The
pipe having external thread at one end i.e. female & or belled end .
The female end having internal thread is to be belled in order to
293 #REF! accept the male end while jointing pipes with a bore threading shall
be provided with a greave at the roof of the male thread
accomodate flexible PVC/Rubber 'O' ring to make the joint water
tight color of the pipe shall be blue The name of the manufacture
along with batch.No class of pipe shall be stranded legibly of each
294 #REF! 200mm dia PVC (sch-80) pipe (As Per SoR -2022) MTR 60 2781.38 1,66,882.68
Supplying all materials, labour, T & P and providing sanitary
sealing by cement concrete grouting of annular space around
295 #REF! GI/PVC/MS housing pipe upto 5m below ground level (as per 1 1384.97 1,384.97
drawing) to plug the bore hole excluding cost of cement all com
Cleaning & developing the tube well with supply of compressor
worked till clear & adequqte discharge is obtained from the tube
296 #REF! well including supply & use of all necessary equipment & labour as
per directin of the Engineer in charge
297 #REF! By DTH Rig EACH 1 7771.48 7,771.48
submersible pump with squirrel cage induction type submersible
type submersible electric motor to run on 3 phase /1 phase line
voltage ranging from 320 volt to 450 volt conforming to Si 8034/89
with following specifications with suitable control panel ,jointing
with GI/PVC/HDPE pipes,electrification,testing, commissioning
298 #REF! ,trial running, conveyance of all materials to worksite , payment of
taxex etc all complete as per specification & direction of the
Engineer in charge
2HP Single phase 3 stage vertical/Horizontal submersible pump
299 #REF! set at head renge of 60 mtr with discharge capacity 200 L P.M with 1 19618.21 19,618.21
outlet dia 32 mm EACH
Dol Control panel
301 #REF! 40mm dia steel short piece EACH 2 238.36 476.72
302 #REF! Well cap EACH 1 179.71 179.71
303 #REF! 50mm size CI bracket PAIR 2 107.73 215.47
304 #REF! 25 sqmm flat cable MTR 65 151.16 9,825.27
305 #REF! 20 mm dia rigid UPVC pipes for cable 69 8.14 561.80
306 #REF! Steel ropes with cover MTR 35 31.51 1,102.71
307 #REF! Labour charges for lowering including transportation EACH 1 2360.00 2,360.00
Supplying all materials ,labour, T&P and providing and fixing to
wall or celling and floor HDPE pipes and pipe fiting conforming to
IS: 4984/2000(10KGF/SQCM) of the following nominal bore with
308 #REF! clamps & joining by Fusion welding method including testing
making good the wall celling & floor all complete as per
specificaations 7 direction of the engineer in charge
309 #REF! 32mm dia HDPE pipe MTR 30 117.76 3,532.92
310 Borewell Chamber.
Supplying all materials, labour, T&P and constructing Bore well
protection chamber of the inside size 650x650x1000hight with
cement concrete (1:3:6) using 40mm size hard granite metal on
foundation, 1st class Fly ash brickwork in cement mortar (1:3),
with base cement concrete (1:2:4) using 12mm size h.g
chips,12mmthick cement plaster (1:4) inside and outside, R.C.C
311 1 cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in
excavation in all kinds of soil and refilling the cavity around the
chamber including watering, curing, conveyance of all materials to
worksite, payment of royalty, taxes etc all complete as per
approved specification and direction of the Engineer in charge.
313 Sub-Total of Plumbing Works TOTAL 34,20,513.60
314 Electrical Works
315 Sub-Head I (modular Wiring Items)
Recessed wirring to light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI
marked with 20 mm dia HMS FRLS PVC conduit ISI marked 6A
modular type switch ISI marked (vision) and ceiling rose ISI marked of
modular type G.I box with metallic cover plate (both side) (vision) of
suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single
316 1 core multistandard copper conductor as earth wire including all 0.00 0.00
accessories and connection as per direction of Engineer -in -Charge. . All
the switches & sockets should be warrantied for a replacement period
of 2 years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of product
& to avail free after sales service within warranty period for acceptance
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying ,fixing of 6A Plug on the same board in existing switch board
with complete fitting by 01 no of 6A switch & socket (modular type)(
(flame retradant type)) & other required accessories of ISI marked as
approved as per direction of Engg. -in -Charge. .(Maximum 02 nos
point in one circuit).All the switches & sockets should be warrantied for
a replacement period of 2 years against defects with ncessary test
report & Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free aftersales service within warranty
period for acceptance of materials.
Supplying,fixing of 6A Plug on the separate board with complete fitting
by 01 no of 6A switch & socket(modular type)( (flame retradant type))
with suitable size modular box & cover( flame retradant type) including
supplying of all required accessories of ISI marked as approved as per
direction of engg-in-charge. .(Maximum 02 nos point in one circuit).All
the switches & sockets should be warrantied for a period of 2 years
321 6 against manufacturing defects against which ncessary test report & Nos 20 650.18 13,003.60 0.00
Warrnaty certificate to be submitted to the department for genuinity of
product & to avail free aftersales service within warranty period for
acceptance of materials.
Supplying,fixing of 1x16A Plug on the separate board with complete
fitting by 01 no of 16A switch & socket(modular type)((flame retradant
type)) with suitable size modular box & cover(flame retradant type)
including supplying of all required accessories of ISI marked as
approved as per direction of engg-in-charge.. (For equipement
322 7 power)All the switches & sockets should be warrantied for a Nos 6 810.66 4,863.96 0.00
replacement period of 2 years against defects with ncessary test
report & Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free aftersales service within warranty
period for acceptance of materials.
Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with
complete fitting by 01 no of 16A+1 no 6A switch & socket(modular
type) ( (flame retradant type) with suitable size modular box & metallic
cover plate (both side)( flame retradant type)including supplying of all
required accessories of ISI marked as approved as per direction of
engg-in-charge. (For equipement power)(Maximum 02 nos point in one
323 8 circuit).All the switches & sockets should be warrantied for a Nos 8 1,518.66 12,149.28 0.00
replacement period of 2 years against defects with ncessary test
report & Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free aftersales service within warranty
period for acceptance of materials.
Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with
complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular
type) ( (flame retradant type) with suitable size modular box & metallic
cover plate (both side)( flame retradant type)including supplying of all
required accessories of ISI marked as approved as per direction of
engg-in-charge (For equipement power). (Maximum 02 nos point in one
circuit).All the switches & sockets should be warrantied for a
replacement period of 2 years against defects with ncessary test
report & Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free after sales service within warranty
period for acceptance of materials.
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single core
cable in recessed HMS FRLS PVC conduit of mentioned size as
required as per direction of Engg.-in-Charge.
325 10 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 Mtr 350 187.62 65,667.00 0.00
no of single core 1.5 sq. mm copper wire for earth continuty conductor.
In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT
copper conductor, single core cable in recessed HMS FRLS PVC
conduit of mentioned size as required as per direction of Engg.-in-
326 11 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 Mtr 500 204.14 1,02,070.00 0.00
no of single core 1.5 sq. mm copper wire for earth continuty conductor
in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT
CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single core
cable in recessed HMS FRLS PVC conduit of mentioned size as
required as per direction of Engg.-in-Charge.
2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no
of single core 1.5 sq. mm copper wire for earth continuty conductor in
20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER
POINT/AC POINT) (2X4+1X1.5)
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single core
cable in recessed HMS FRLS PVC conduit of mentioned size as
required as per direction of Engg.-in-Charge.
2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no
of single core 2.5 sq. mm copper wire for earth continuty conductor in
25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB)
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single core
cable in recessed HMS FRLS PVC conduit of mentioned size as
required as per direction of Engg.-in-Charge.
329 14 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 Mtr 65 376.42 24,467.30 0.00
nos of single core 4 sq. mm copper wire for earth continuty conductor
in 32 mm dia non metallic heavy duty conduit.(LFDB TO
LBDB/Medical equipement) (4X6+2X4)
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single core
cable in recessed HMS FRLS PVC conduit of mentioned size as
required as per direction of Engg.-in-Charge.
330 15 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 Mtr 65 526.28 34,208.20 0.00
nos of single core 6 sq. mm copper wire for earth continuty conductorin
32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL
TO TPN BDB power) (4X10+2X6)
Supplying and installation of 25A AC starter Modular type,
Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of
suitable size including modular coveras required as per direction of
Engg.-in-Charge .All the Components should be warrantied for a
331 16 replacement period of 2 years against defects with ncessary test Nos 7 739.86 5,179.02
report & Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free aftersales service within warranty
period for acceptance of materials.
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing
switch box/cover .as required as per direction of Engg.-in-Charge.All the
Components should be warrantied for a replacement period of 2 years
332 17 against defects with ncessary test report & Warrnaty certificate to be mtrs 2 252.52 505.04 0.00
submitted to the department for genuinity of product & to avail free
aftersales service within warranty period for acceptance of materials.
S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or
equievalant reputed make A catagory ISI marked as approved )of ISI
marked conforming to IS-1258/1987 in place of ceiling rose as per
direction of Engg.-in-Charge .All the Components should be warrantied
for a replacement period of 2 years against defects with ncessary test
report & Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free aftersales service within warranty
period for acceptance of materials.
S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all
connection complete in all respect as per direction of Engineer in
335 B Sub-Head II (Light fitting Fixture & Fan)
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400
rpm with louvers of exhaust fan in the existing wall, including fixing &
conntection as required as per direction of Engg.-in-Charge. Replacement
Warranty will be 2 years.
Supplying, installation, of exhaust fan of heavy duty 380 mm
sweep 1400 rpm with louvers of exhaust fan in the existing
wall, including fixing & conntection as required as per
337 2 direction of Engg.-in-Charge. Replacement Warranty will be 2 Nos 2 4,573.68 0.00 9,147.36
Supplying, installation, testing and commssioning of 1200
mm sweep white/milky colour BLDC ceiling fan with
aluminium blades having wattage not more than 28W and air
delivery ≥215m3/min including wiring the down rod of
standard length (upto 30 cm) with 1.5 sq mm PVC insulated,
copper conductor, single core cable etc. as required as per
direction of Engg.-in-Charge,Replacement Warranty will be 4
years.(With fan Regulator)
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying an fixing of recess/surface mounted 2'x2' 36
W(595mmx595mmx70mm) square shaped LED with lumen
efficacy not less than 130lm/W, CRI not less than 80, CCT of
5700-6500 degree K, THD less than 10%,internal surge
protection of 3 KV, complete with Non integrated isolated
electronic driver (protects the output /secondary side from
any disturbance on the input / primary side ensuring safe
339 4 operation)and all other accessories suitable for operation Nos 15 5,574.32 0.00 83,614.80
on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years
warranty) as required as per direction of Engg.-in-Charge.
The luminaire must be Replacement Warranty will be 5
Supplying and fixing of Energy efficient surface /recess mounted
square /round shape 18 W LED luminaire of dimension of consists of
white powder coated , die-cast Alluminium housing with high quality
frosted diffuser for glare-free uniform lighting distribution with wattage
not more than 18 watt and lumen output of 1800 lumens, , CRI not less
than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, Nos 80 1,817.20 0.00 1,45,376.00
internal surge protection of 3 KV , L70 B50: 50000 hrs and all other
accessories suitable for operation on 220 V to 240 V supply as required
as per direction of Engg.-in-Charge..The luminaire should be
Replacement Warranty will be 2 years
SITC of energy efficient LED tube light fittings with decorative
alluminium batten and LED tube light having power rating not
more than 20 watt and lumen output not less than 2200
lumen complete with electronic driver and all other
341 6 accessories with diffuser having 2 years warranty i/c Nos 30 859.04 0.00 25,771.20
connection etc as required as per direction of Engg.-in-
Charge. . The luminaire should be Replacement Warranty will
SITC of Sleek LED 10 watt mirror light fitting with extruded
polycarbonate housing,High optically efficient diffuser,above
wash basin complete with all accessoriesetc. directly on wall,
including connection with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and earthing etc. as required as per
direction of Engg.-in-Charge.
.The luminaire should be Replacement Warranty will be 2 years
Supplying and fixing extra conduit down rod of 20 cm length G.I.
pipe 15 mm dia, heavy gauge including painting etc. as requiredas
required as per direction of Engg.-in-Charge .
(Note : More than 5 cm length shall be rounded to the nearest 10
cm and 5 cm or less shall be ignored)of ISI mark as approved.
344 BDBS,DB,AC DB,FLOOR PANELS,MCBS 0.00
Supplying and fixing of following mentioned way, three pole/single
pole and neutral, sheet steel,double door MCB distribution board, 415
volts/240 volts shall be as per IEC 61439-3,integrated door earthing
system offering additional safety to the user,High quality polyurethane
Gasket,the box and cover shall be fabricated to withstand IK09,the DB
should be properly pre-treated with 7 tank process and duly powder
coated, phosphatized with powder coated finish, on surface/recess, 0.00 0.00
complete with terminal blocks,with suitable size FR PVC insulated
copper conducter up to terminal blocks, tinned copper busbar, neutral
busbar, earth bar, din bar. as per direction of Engg.-in-Charge. The
Distribution boards should be Replacement Warranty will be 3 years.
4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC
61439-3 suitable for Flush mounting and Surface mounting with
100A Copper Bus Bar for each phase, with neutral Bus bar, Earth
346 2 Bar & Cable ties for cable management, prefitted masking sheet, 6 5,038.60 0.00 30,231.60
IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-
PH,POWER LOAD) Warranty on DB is 3 years.
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supply and fixing of 12 way DD single pole and neutral sheet
steel MCB distribution board 250V on surface/recess complete
with tinned copper bus bar, neutral bus bar, earth bar, din bar,
detachable gland plate, interconnections, phosphatized and
powder painted including earthing etc. as required (but with out
347 3 MCB/ RCCB/ Isolator) (ALL LIGHT WITH 2 2,321.06 0.00 4,642.12
CORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM
LOAD LIGHT LOAD,POWER LOAD ) Warranty on DB is 3 years.
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C
series, single poles MCB of . the existing MCB DB complete with
connections as per direction of Engg.-in-Charge.Warranty on MCB
Supplying and fixing 40 Amps rating, 4P, 415 volts, MCB . Make-
LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB
200 in the existing MCB DB complete with connections, testing
and commissioning etc. as required as per direction of Engg.-in-
349 5 Charge. .(4W TPN BDB IC). The MCB should be Replacement 2 3499.88 0.00 6,999.76
Warranty will be 3 years
Supplying and fixing 40 Amps rating, 4P, 415 volts, RCCB 30mA .
Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti
9/ABB FB 200 in the existing MCB DB complete with connections,
350 6 testing and commissioning etc. as required as per direction of 3 6182.02 0.00 18,546.06
Engg.-in-Charge. .(4W TPN BDB IC). The MCB should be
Replacement Warranty will be 3 years
Supplying and fixing 40Amps DP 240 volts, RCCB 30 mA Make-
LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB
200 in the existing MCB DB in the existing MCB DB complete
with connections as per direction of Engg.-in-Charge. The MCB
should be Replacement Warranty will be 3 years
Supplying and fixing 40Amps DP 240 volts, MCB in the existing
MCB DB in the existing MCB DB complete with connections as
352 8 per direction of Engg.-in-Charge. The MCB should be 3.00 1799.50 0.00 5,398.50
Replacement Warranty will be 3 years
Supplying and fixing 63Amps 4P 415 volts MCB SB 200 in the
existing MCB DB in the existing MCB DB complete with
353 9 connections as per direction of Engg.-in-Charge.(for power BDB , 3.00 3499.88 0.00 10,499.64
4 way TPN BDB IC).The MCB should be Replacement Warranty
will be 3 years
Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA in the
existing MCB DB in the existing MCB DB complete with
354 10 connections as per direction of Engg.-in-Charge.(for power BDB , 3.00 6182.02 18,546.06
4 way TPN BDB IC).The MCB should be Replacement Warranty
will be 3 years Nos
355 (Earthing) INSTALLATION
Supplying,installation,testing & commissioning of materials and
installation of GI earth plate 600mmx600mmx6mm thick ISI
marked with G. I. nut bolts & washers including cost of burnt
wood charcoal, salt, foreign soil, water pouring arrangements, 2.00 7670.00
brick masonary enclosure on top with removable RCC cover
complete with labour for excavation of pit in all kinds of soil & rock
as required and as per direction of Engineer-in-charge.
Providing and fixing 6SWG GI wire on surface or in recess for
357 2 loop earthing as required.as per direction of Engg.-in-Charge. 140.00 29.50 0.00 4,130.00
Providing and fixing 25mm x 5 mm GI strip on surface or in recess
358 3 for connections etc. as required as per direction of Engg.-in- 140.00 179.36 0.00 25,110.40
359 e) CABLING AND END TERMINATION MAIN AREA
Supplying of one number PVC insulated armoured and PVC sheathed
XLPE property AL. conductor power cable of 1.1 KV grade
360 4 following size cables as per direction of Engg.-in-Charge. 0.00
Supplying of one number PVC insulated armoured and PVC sheathed
XLPE property AL. conductor power cable of 1.1 KV grade of
following size cables as per direction of Engg.-in-Charge. Ncessary
test report & Warrnaty certificate to be submitted to the department
362 6 for genuinity of product & to avail free after sales service within 0.00 0.00
warranty period for acceptance of materials
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
366 10 LAYING OF CABLE 0.00
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade
size not exceeding 25 SQ. MM direct in ground in the trench in one
horizental formation including excavation ,sand coushing protection
367 11 covering and refilling the trench etc as required as per direction of Engg.- 15 185.26 2,778.90 0.00
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade
size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in
ground in the trench in one horizental formation including excavation
,sand coushing protection covering and refilling the trench etc as
required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade
size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in
ground in the trench in one horizental formation including excavation
369 13 ,sand coushing protection covering and refilling the trench etc as 30 236.00 7,080.00 0.00
required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade
size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc
as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade
size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in
371 15 ground in the EXISTING PIPE etc as required as per direction of Engg.-in - 21 93.22 1,957.62 0.00
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade
size not exceeding 25 SQ. MM in open duct etc as required as per
372 16 direction of Engg.-in -charge. 10 54.28 542.80 0.00
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade
size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in
the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade
size not exceeding 25 SQ. MM in surface with shaddle and screw etc as
374 18 required as per direction of Engg.-in -charge. 12 1,486.80 0.00
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade
size not exceeding 120 SQ. MM From 25 SQ. MM in surface with
shaddle and screw etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade
size not exceeding 400 SQ. MM From 120 SQ. MM in surface with
shaddle and screw etc as required as per direction of Engg.-in -charge.
Supplying and making end termination with brass compression gland and
377 21 aluminium lugs for following mentioned size cable.as per direction of 0.00 0.00
Engg.-in-Charge.
Providing,fixing and laying of following dia G.I. pipe (medium class) in
382 22 ground complete with G.I fitting incl. trenching(75 mm depth)and refilling 0.00
as per direction of Engg.-in-Charge.
Providing,fixing and laying of following dia HDPE pipe (medium class) in
384 23 ground complete with fitting incl. trenching(75 mm depth)and refilling as 0.00 0.00
per direction of Engg.-in-Charge.
386 MAIN CONTROL PANEL AT GF -
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical
main panel (for both light and power circuit) made out by 2mm CRCA
steel sheet duly derusted & painted by simens grey powder cote paint is
designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING
MAIN)as per direction of Engg.-in-Charge. Warrentee period of
387 1 replacement of panel & accessories must be 1 year & compelete test 1 116466 1,16,466.00
certificate must be submitted along with panel board including
component list. 2 nos of 3P+N Type 1+2 SPD 65 kA with 63A 4P
MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate
Aluminium Earth bus bar should be installed.. Set
In commer-1-01 number of 160A 4P Icu=100%Ics,36Ka LSIG
388 MCCB with micro processor based release Electrical locking 0.00
for normal & DG
In commer-2-01 number of 100A(100-80) 4P
Icu=100%Ics,25kA LSIG MCCB with micro processor based
release Electrical locking for normal & DG From DG
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
In commer-2- 01 no of 100A 4P onload changeover switch
Busbar- 04 numbers of 200 Amps al. bus bar busbar duly
391 sleeved by color coded PVC sleeve & supported by suitable size
Out going- 01 numbers of 63A 4P MCCB,25Ka MCCB with
TMR based release with adjustable overload ,Icu=100%Ics
393 Out going- 4 numbers of 32A 4P MCB10kA,C series.
394 Out going- 6 numbers of 63A 4P MCB 10kA,C series.
Instrument- (i) 06 numbers phase indicating lamp with toggle
switch & HRC fuse.
(ii) Digital Meter Displays Current, line to neutral & line to line
Voltages, frequency & Power Factor. (VA & PF - Phase Wise &
Average) (SECURE/ Legrand )
397 CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER 0.00
Supplying,fixing of perforated cable trays with horizental &
vertical bends,reducers ,tees,crossover,brakets & other
accessories ar requited confirming to IS-IEC -61537 ,the cable tray
shall be galvanised for corrosion protection confirming to DIN EN
Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays
should be minimum of 104.8Kg/meter at the span of 1.5Meter
as per UL specifications as required as per direction of Engg.-in-
Supplying,fixing of perforated cable trays with horizental &
vertical bends,reducers ,tees,crossover,brakets & other
accessories ar requited confirming to IS-IEC -61537 ,the cable tray
shall be galvanised for corrosion protection confirming to DIN EN
Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays
should be minimum of 104.8Kg/meter at the span of 1.5Meter
as per UL specifications as required as per direction of Engg.-in-
GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY WITH
JUNCTION with internal dimensions of size 38mm(H) x
225mm(W), of MAKE- Profab/OBO/Neidax .(With all
accessories,bend,cover,supporter)WITH REQUIRED SIZED
JUNCTION BOX ,COVER CONNECTOR as required as per direction
of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT mtrs
401 LIGHTENING PROTECTION 0.00
Lightning Protection :- Supply of 8 mm Aluminum Round
402 1 Conductor.Tested as per IEC 62561. as per direction of engineer in Mtr 230 175.82 0.00 40,438.60
Supply of Roof conductor holder for parapet- Polyamide
Conductor holder:With M8 female thread or diameter 7mm, M8
Screw to connect the conductor holder.Weather and
temperature resistant from -35 to +90 degree Celsius tested.
Conductor holder @ 1 meter distance.Tested as per IEC 62561. as
per direction of engineer in charge
Supply of Polyamide roof cable holder for flat roof:
DIN 48829 Form B1. Closed form with bottom. Filling weight
1Kg (frost-resistant concrete). Sleeve from polyethylene, black
@ 1 meter distance. Tested as per IEC 62561.
Supply of Connector: For T cross and parallel connectors. Quick
405 4 installation using hexagonal bolt M10X30 high-grade hot dip No 20 239.54 0.00 4,790.80
galvanised. Tested as per IEC 62561.(2nos/expansion piece ).
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supply of 1 mtr vertical air terminal with mounting accessories
on the flat surface to meet the requirements of IS/IEC 62305.
Tested for Electrical , mechanical and chemical as per IEC
62561. Tested for 100kA lightning current.
Supply of Vertical air terminal with accessories:Providing of Air
as per IS-IEC -62305 part-3
407 6 Nominal size Ø10/16 mm aluminium rod: No 5 3,724.08 0.00 18,620.40
3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN
48801) Suitable for high wind load.
Tested as per IEC 62561.
Supply for Providing of Stand for Fang Fix system 16 kg with base
clamp ,made up of frost resistant concrete and clamp tested
upto 100KA lightning current
Supply for Providing of Stand for Fang Fix system 16 kg made up
resistant concrete.
Supply of Test Joint (Folding Clamp) suitable to connect 8mm
round conductor and max by 30x3 mm GI strip as specified in
drawing and directed by Engineer.
Tested for 100kA lightning current.
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr
For Test Joint .Internal dimensions: 100x100x48 mm
Supply of Galvanised Steel Flat 30X3 mm thickness from earth
412 11 electrode directly in ground as required. Flat conductor Hot Mtr 120 318.60 0.00 38,232.00
Dipped Galvanized. Tested as per IEC 62561
Supply for Providing of Cross connector for Flat: Suitable for
30mm Galvanised steel strip. Installed with 4 nos of hexagonal
plate. Tested for 100kA lightning current. Make-
OBO/Dehn/ABB/Equivalent
Supply of flat conductor holder- Fit: FL 30, With mounting hole
6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from
hot-dip galvanised steel, Bottom section from polyamide, black.
Tested as per IEC 62561.
Supply for Providing of Plastic Corrosion Protection strip: Approx
415 14 1.1 mm thick. Width 50mm. Made of petrolatum- coated No 2 1,037.22 0.00 2,074.44
chemical fibre fabric.
Supply of UL Listed maintenance free ,Low carbon copper
coated earth rod of 3 metre electrode having diameter of 17.2
mm with copper coating thickness of 250micron tested as per
Supply of universal clamp made of SS to connect rod with flat
Supply of Earth conductivity enhancing mineral compound shall
kg/pit tested as per IEC 62561-7,TCLP tested
Supply of The above arrangements shall be provided with Heavy
earth champer of 5000kg load bearing capacity to ensure the
safety of earthing system
Installation of The above arrangements including all accessories as
per Direction of Engg. In charge.
421 EPABX, LAN, CCTV & INVERTER SYSTEM 0.00
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing
surface/ recessed steel/ PVC conduit as required: The 4 pair
Unshielded Twisted Pair cable shall be UL Listed,exceeds the
requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4
twisted pairs separated by internal PE Cross Separator. Full
separator. Half shall not be accepted. Rip Cord is must,Insertion
Loss of 32.8 db/100m at 250 MHz ,Cable should support operating
temperature from -20° to +70°C Cable support Conductor
Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45
ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100
MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL
Verified 4 connector channel performance up to 700 MHz , RoHS
SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or
exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, &
EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT,
PSELFEXT and return loss should be verified for CAT6 @ 250Mhz
423 2 & CAT6A @ 500Mhz. The information outlet connector shall be of Nos 6 1,195.34 0.00 7,172.04
gold/nickel, thickness of gold > 0.8 μm. The connectors shall be
compatible as per IEEE 802.3af standard for POE application. The
PVC material of Face plate should complie ABS /UL94-V-O
SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or
exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, &
EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT,
PSELFEXT and return loss should be verified for CAT6 @ 250Mhz
424 3 & CAT6A @ 500Mhz. The information outlet connector shall be of Nos 4 808.30 0.00 3,233.20
gold/nickel, thickness of gold > 0.8 μm. The connectors shall be
compatible as per IEEE 802.3af standard for POE application. The
PVC material of Face plate should complie ABS /UL94-V-O
SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should
accommodate Cat6 with Rear Cable Management and Front
removable Tooless Information outlet. Should have easy clip
425 4 management with labels and clear label covers, Made with of Nos 2 11,585.24 0.00 23,170.48
Dicast Aluminium Alloy Material and Non Corrosive with Cat6
toolless RJ45 x 24 ports with color code front panel with patch
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch
Cords are Factory Tested for Better Quality and Suitable for the
High Speed Data Transmission. Complies to the Standard
ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds
426 5 Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Nos 6 403.56 0.00 2,421.36
Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2
FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested ,
Transparent Boot Cable Assemblies.
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch
Cords are Factory Tested for Better Quality and Suitable for the
High Speed Data Transmission. Complies to the Standard
ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds
427 6 Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Nos 6 480.26 0.00 2,881.56
Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2
FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested ,
Transparent Boot Cable Assemblies.
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber
cable through existing conduit: The Fiber should be OS2 Single
Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated
Steel tape Central loose tube. ( Standard Approved: ISO 11801
class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation
G.652.D - the oder ITU designations A, B and C are also fulfilled /
OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are
fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket.
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
SITC of Rack mount Draw Type Loaded 6 port LIU available in
Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled
Steel as Raw Material , Consist of Top Cover and Bottom Panel ,
Easy to Assemble and Dissemble , Three Types of Input Holes
429 8 Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or nos 2 9,848.28 0.00 19,696.56
LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray
,Adaptor, SM, Duplex SC, PC Type ,Support the TIA/EIA
Telecommunication Wiring Standards. Compact Design ,
Telcordia GR-326-Core .
SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type,
3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in
LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max nos 2 2,715.18 0.00 5,430.36
0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db,
431 10 Supply & Installation of 1000Base LX Fiber Transceiver. nos 2 6,636.32 0.00 13,272.64
SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000
Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45
port console port ,Switching Capacity 128 Gbps , Throughput 96
Mpps ,MAC Address 16k , Switch should support IEEE 802.3af
(15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above ,
Switch should support DHCP server/relay/client, DHCP
snooping/option82 , Switch should support Console, Telnet, SSH
v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP,
ZTP, SPAN, RSPAN,Switch should support support ICMPv6,
DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power
Supply AC: 100-240V.
SITC of 9U/500D Wall Mount Rack with Accessories: The rack size
should be 600W x 500D, Front frame integrated with top, bottom,
front and two side panels for better rigidity and strength, Front
Glass Door with Lock loaded, Compliance with standards shall be
UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-
2-11 , ISO 9001:2008 including Power Distribution Unit (06/16
Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable
/ 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with
Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC -
90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable
loops and H/W screw.
SITC of 24U 600/650D UL Listed Floor mount Rack with Front
perforated door with 3 point lock, Rear mesh door with Cam lock
and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-
Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp
434 13 MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable nos 1 47,347.50 0.00 47,347.50
2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with
Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray -
Ventilation - 495W - 375D and H/W screw920sets).
Supplying and fixing of following sizes of Heavy class PVC FRLS
conduit ISI marked along with accessories in surface/recess
435 14 including cutting the wall and making good the same in case of 0.00 0.00
recessed conduit as required as per direction of Engg.-in-Charge
Subhead- 3 (IP-CCTV System)
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supply, Installation, Testing & Commissioning of 5MP IP Network
TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8" CMOS or
better, 5MP (2592 x 1944) @ 25fps or better, triple stream at
various resolution & Frame Rates, Min. Illumination required
0.007 lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 50m
IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N
Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video
Compression technology such as H.265, H.264 & MJPEG , Fixed
Lens 2.8mm, Field of View FoV H:90°, V:62°, BLC, HLC, WDR,
3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence
439 1 Video Analytics : Video Motion Detection, Tampering, Loitering, Nos 10 17,638.64 0.00 1,76,386.40
Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of
Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet
closed, Stream Encryption, 2-Way Audio Full Duplex Line IN/Out,
256GB SD card support, Alarm: 1In/1out, PoE (802.3 af) and 12V
DC, Max 5W, IP 66/67 & IK10 with Die Cast Aluminium Housing,
Having Operating temp range : –40°C to 60° C. Certifications:
ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN
55032 & RoHS (EN63000)/NDA compliant.
Supply, Installation,Testing & Commisioning of Surveliance 10 TB
SITC of 55" UHD IPS Commercial Digital Display for Small Size
Discussion & Chambers: Brightness (440 nits or higher), Dynamic
Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static
(Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms,
441 3 Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Nos 1 1,10,777.22 0.00 1,10,777.22
Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C
Broadcasting System, Commercial Smart UX, webOS version
(webOS 6.0), BIS Certification with 3 years onsite warrenty.
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supply , Installation, testing , commissioning of 32 Channel NVR
with 4 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels
Resolution Display and Recording, H.265 video compression
technology with real time encoding, Full function CMS (Central
monitoring software) supported, Two way audio supported, Dual
streaming technology to encode recording stream and network
stream separately, Supports remote monitoring on Mobile Client
(Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP,
SMTP, Time/ Date, Alarm, Motion Detection & Exact Search
(accurate to second), Record Snapshot, FTP, Preset Calling, Email
notification supported, Manual/ Alarm/ Motion Detection/
Continuous, CE, FCC, RoHS).
443 Sub-Total of Electrical Works 12,47,936.05 15,29,051.08
444 A PUMPS AND APPURTENANCES
Supplying, installation, testing and commissioning of Electric Motor
Driven Pressurization Terrace Pump having discharge of 450
445 1 LPM at 35 Mtr head complete with Pump Set, Electric Motor Nos 1 77,266.40 0.00 77,266.40
suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base
SITC of FRLS,PVC outer sheateh, steel armoured, aluminium ,
446 2 1100v grade power cables with glands etc.The minimum size of 0.00 0.00
the cables shall as mentioned below,
Supply, installation, testing and commissioning of Floor/Wall
mounted sectionalised, front operated top entry dust and vermin
proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4
wire, 50Hz distribution system fabricated out of 2.0 mm thick
CRCA sheet, insulated busbar with heat shrienkable PVC sleeve,
base frame, complete with all accessories including
interconnections, earth bus etc as required comprising of One (1)-
63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating
lamps with control fuse/ MCB, Digital Voltmeter with selector
switch. DOL starter with O/L and Single Phasing Preventor
suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual
switch and ON/OFF push button.as per direction of engineer in
charge Control panel for fire pumps for auto action
450 B PIPE & VALVES ETC.
(as per IS 1239 upto 100 mm NB and IS 3589 for above 100 mm
6.33mm thick) with flanges and fitting such as bends, tees,
reducers, rubber insertions and galvanized nuts and bolts of
following size on surface along wall / shaft with MS bracket,
451 1 suspended from ceiling/ beam with suspenders duly painted with
two coats of primer and finished with enamel paint of approved
colour laid through pipe or in trench after wrapping with hassen
cloth after applying coal tar primer as required as per direction of
Engineer-in- charge
Providing, fixing, testing and commissioning of following size
manually operated hand lever type cast iron double flanged slim
seal wafer type Butterfly valves with EPDM iron disc as per IS-
13095 having pressure ratting PN -1.60 including fixing the same
with supply of required jointing materials like rubber insertion, MS
nuts & bolts, paint etc. and testing the joints with required water
pressure etc. all complete as per specification & direction of E.I.C
Providing, fitting & fixing of following size cast iron double flanged
type dual plate Non return Valve as per IS- 5312 (Part 1): 2004
with ISI mark of pressure ratting PN-1.60 including fixing the same
with supply of required jointing materials like flanges, rubber
insertion, MS nuts & bolts, paint etc. and testing the joints with
required water pressure etc. all complete as per specification &
direction of Engineer-in-charge.
SITC of Gun metal chrome finished Ball valves with fittings of
screwed end type.
Supply,Installation,Testing & Commissioning of Pressure gauge of
0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable
size with all accessories as per direction of Engineer-in-charge.
Supply,Installation,Testing & Commissioning of Pressure Switch
with cut-off bronze ball valves with integral strainer & flare nut
(mixed ends) of suitable size with all accessories as per direction
of Engineer-in-charge.
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supply,Installation,Testing & Commissioning of stainless steel
strainer fabricated out of 1.6 mm thick stainless steel sheet Y
Stainer with 3 mm dia hloes with stainless steel flange as required.
466 C DOWN COMER SYSTEM
Supply,Installation,Testing & Commissioning of Stainless steel
Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single
headed , oblique type, as per IS :5290/93 and as per direction of
Engineer-in-charge.
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supply,Installation,Testing & Commissioning of SS short branch
468 2 pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 Nos 2 2,808.40 5,616.80
and as per direction of Engineer-in-charge.
Supply,Installation,Testing & Commissioning of 63 mm NB and
15meter long RRL Fire Hose fitted with 63mm intstantaneous
469 3 stainless steel male & female SS coupling, complete by GI wire Nos 4 6,926.60 27,706.40
binding for Internal Hydrant as per direction of Engineer-in-charge
Providing supply & fixing of MS Hose Box for of suitable
size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr
long fire hose and a branch pipe, wall mounted type as per
direction of Engineer-in-charge
Supply,Installation,Testing & Commissioning of Swinging pattern
wall fixing first aid hose reel made from MS sheet and waterways
and moving parts with rubber hose of 20 mm dia. and 30 mtrs.
long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585
Type-I., complete with all accessories as per direction of Engineer-
Providing, fitting and fixing of C.I. 25 MM single air relief valve with
stop cock confirming to IS:14845/2000 with ISI mark for water
works purpose including fixing the same with hydrant riser
including testing & commissioning the system etc. all complete as
per approved specification & direction of Engineer-in-charge.
Providing, fitting & fixing of 2-Way GM fire brigade connection
consisting of 63 mm dia instantaneous type male couplings with
built-in check valves, 150mm dia flanged outlet complete with
473 7 bolts, nuts and rubber insertions confirming to IS:904 with ISI mark Nos 1 6,974.98 6,974.98
including testing & commissioning the system etc. all complete as
per apporoved specification & direction of EIC.
474 D EXTINGUISHER SYSTEM
Supply,Installation,Testing and Commisioning of ISI marked
475 1 (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg nos 4 9,086.00 36,344.00
with all accessories
Supply,Installation,Testing and Commisioning of ISI marked
476 2 (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all nos 4 3,851.52 15,406.08
Fire buckets (FILLED WITH SAND) round bottom type enamel
477 3 painted, white inside & Red out side and Letter "FIRE" in black out nos 2 5,000.84 10,001.68
side and handle with mounting bracket.
478 E SIGNAGES
SIGNAGES:-Providing and installing in position the following type Sqinch
of sign boards made out of 3mm thick flexyle photoluminescent
based glow in dark sheeting with luminous properties enclosed in
a weather proof Uvstabilized film with UV screen printing by
imported links pasted over3 mm thick cast acrylic from front side
479 1 with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, 350 21.24 7,434.00
greenish yellow, glow visible upto 4-6 hr in total darkness.
Supply, Installation,Testing & Commisioning of Manual based
Addresable fire alarm control panel , fully networkable with each
loop capable of taking 99 devices, 8 line x 40 character alpha-
numeric liquid crystal display .The panel shall be soft addressable
type . The panel shall be able to give pin point location of all
fire/fault conditions. Further, the panel must be able to
480 2 automatically switch off respective control switches when ever any
alarm is triggered. The panel shall have integral SMF lead acid
batteries with sealed cells of 24 V capable of running for a
minimum of 8 hours with integral battery charger complete as
required and as per specification. The fire alarm panel shall be
suitable for software integration with BMS & PA system.
Supplying, installing, testing and commissioning of Addressable
Manual Call Point with back box.
Supplying, installing, testing and commissioning of Analogue
Addressable Loop powered Sounder with strobe light.
Supplying, installing, testing and commissioning of 2C x 1.5 mm²,
armoured, single stand, outer sheathed, FRLS, PVC insulated
copper conductor cable confirming to specified IS standards .
485 F PA SYSTEM
Supplying, installation, testing & commissioning of 2 zone,voice
alarm controller with USB, MP3 player (including 2 zone button
486 1 paging station) with seamless integration facility with main fire Nos. 1 65,724.82 0.00 65,724.82
alarm panel for voice evacuation complete as required
Supplying, installation, testing & commissioning of digital audio
amplifier 250 Watt, 25V rms operating at 240 Volt AC Supply
487 2 complete as required. Nos. 1 46,680.80 0.00 46,680.80
Supplying, installation, testing & commissioning of ceiling/wall
mounted loud speaker, 3/15 Watt in ABS enclosure complete as
Digitally signed by DIWAKAR
BoQ : CENTRE FOR INDIGENOUS KNOWLEDGE & LANGUAGE
Abs. Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Schedule Amount
Sr. Rate Amount
Supplying and drawing of speaker cable Single pair, 2-core, 1.5
489 4 sqmm in existing conduits Mtr. 140.00 76.70 0.00 10,738.00
490 Sub-Total of Fire Fighting Works TOTAL 7,12,003.74
491 FAÇADE WORK
Providing & Installation of GFRC GFRC JALI (Glass Fiber
Reinforced Concrete) thickness of 25-30 mm & Border thickness
of 50 mm with Pattern, design, and colour of approved make to be
fixed on/between RCC /Block work Column or structural work with
Dry Fixing method with appropriate SS Pipe & Cleats frame work,
using fasteners, and necessary hardware etc. The element shall
be made from '53 grade' Portland Cement make Birla/ 'JK Cement'
or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass fibre
492 1 make 'Owens Corning' or equivalent, Super plasticizers / Additives Sqm 86.96 6785.00 0.00 5,90,003.25
make by 'BASF' or equivalent, Polymers make 'BASF' or
equivalent and U.V resistant Synthetic inorganic pigments shall be
used for pigmentation make 'BAYFERROX (Germany)' or
equivalent. The material casting shall take place in Synthetic
Rubber / FRP Mould manufactured by Mould / Tool / Mould Grade
Resin of Revex/ 'Reckli' or equivalent.
493 Sub-Total of Facade Works TOTAL 5,90,003.25
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Civil Works 0.00 0.00
Earth work in excavation of foundation trenches in hard soil
including dressing of sides and levelling the bed up to the required
depth and depositing the excavated materials away from the work
1 1 site within 50m initial lead & 1.5m initial lifts with sundries & T&P
required for the work complete including cost of all labour,labour
cess,T&P,sundries etc. as directed by the Engineer in charge.
Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
ramming & watering with all leads & lifts including cost of all
labour,T&P completed as directed by the Engineer-in-charge.
Supplying and filling in foundation and plinth with good quality river
sand including watering, ramming with cost, conveyances,
royalties of all materials and cost of all labour with T&P required
5 5 for the work etc. complete as per specification & direction of 0.00
Engineer-in-charge
Providing & applying of pre constructional anti-termite treatment
by drilling 12mm dia holes at distance of 30cm @ junction of wall
& floor about 300mm apart deep enough to reach the soil below &
chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr
water) pumped these holes to soak the soil @ 1 ltr solution of
7 7 each hole as per manufactures specification & the holes should Sqm 347.00 123.31 0.00 42,788.57
be pluged the filling materials including cost of all materials,
labour,conveyance, T&P , all taxes and hire charges of
machinaries as per direction of Engineer-in-charge.
Cement concrete of proportion (1:3:6) in foundation and floors
using 4cm size clean hard black crusher broken granite stone
metal of approved quality and from approved quarry including
hoisting, lowering and laying concrete in layers not exceeding 15
cm. (6") thick to the required level ramming, watering, curing etc.
8 8 complete including cost, conveyance, royalties of all materials with 0.00
all labour and T&P required for the work etc. complete in all
respect and as per the direction of the Engineer-in-charge.
Plain cement concrete (1:2:4) using 12mm size black hard crusher
broken granite chips of approved quality from approved quarry
including hoisting, lowering and laying concrete in layers,
watering, curing etc. complete including cost, conveyance,
royalties of all materials with labour,labour cess and T&P etc.
10 10 required for the work complete as per the direction of the Engineer- Cum 19.34 10652.69 2,06,022.95 0.00
Fly Ash brick masonry in cement mortar (1:6) in foundation &
plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a
crushing strength of not less than 75 kg./sqcm with dimensional
tolerance ± 2% including splays cutting circular moulding
chamfering and corbelling and similar such type of works with all
11 11 necessary projections watering and curing after immersing the Cum 16.13 6792.08 1,09,556.25 0.00
bricks in water at least for six hours before use including cost,
conveyance, and royalties of all materials with all labour,labour
cess and T & P required for the work complete in all respect as
per direction of Engineer-in-Charge
Fly Ash brick masonry in cement mortar (1:6) in super structure
using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing
strength of not less than 75 kg./sqcm with dimensional tolerance ±
2% including splays cutting circular moulding chamfering and
corbelling and similar such type of works with all necessary
projections watering and curing after immersing the bricks in water
at least for six hours before use including cost, conveyance,
royalties and taxes of all materials with all labour,labour cess and
T & P required for the work complete in all respect as per direction
of Engineer-in-Charge.arge.
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Fly Ash brick masonry in cement mortar (1:4) in super structure
using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing
strength of not less than 75 kg./sqcm with dimensional tolerance ±
2% including splays cutting circular moulding chamfering and
corbelling and similar such type of works with all necessary
projections watering and curing after immersing the bricks in water
at least for six hours before use including cost, conveyance,
royalties and taxes of all materials with all labour,labour cess and
T & P required for the work complete in all respect as per direction
of Engineer-in-Charge
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
19 19 shuttering then after dismantling and removing debris from the 0.00 0.00
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
20 20 Ground Floor 0.00 0.00
30 30 1st floor 0.00
37 37 Terrace floor 0.00 0.00
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor
steel of primary steel producers such as SAIL / TATA / RINL /
JINDAL STEEL / SHYAM STEEL/ SEL Tiger (grade Fe-500D) etc.
including bending, binding, welding and jointing if necessary and
tying the grills and placing in position as required for R.C.C. Work
and for providing fan hooks as required, hoisting, lowering, laying
including cost, conveyances of M.S. Rod or tor steel and binding
wires of 18 to 20 gauge and labour required for the work for
bending, binding and tying the grills in all floors with labour cess
etc. (payment will be made on standard weight of B.I.S. for M.S.
Rods or tor steel only) etc. complete as per specification &
direction of Engineer-in-charge.
Providing 12 mm thick cement plaster with cement mortar of mix
(1:6) with screened and washed sharp sand for mortar and
finished smooth to the rough surface of walls in all heights after
racking out joints including watering and curing, rounding of
46 46 corners, providing grooves where ever necessary with cost, 0.00 0.00
conveyance, royalties of all materials with cost of all labour,labour
cess, T&P, and scaffolding required for the work etc. complete in
all respect as directed by the Engineer in charge.
Providing 16 mm thick cement plaster with cement mortar of mix
(1:6) with screened and washed sharp sand for mortar and
finished smooth to the rough surface of walls in all heights after
racking out joints including watering and curing, rounding of
50 50 corners, providing grooves where ever necessary with cost, 0.00 0.00
conveyance, royalties of all materials with cost of all labour,labour
cess, T&P, and scaffolding required for the work etc. complete in
all respect as directed by the Engineer in charge.
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Providing 6 mm thick cement plaster with cement mortar of mix
(1:4) with screened and washed sharp sand for mortar and
finished smooth to R.C.C. work after closed deep chipping & slurry
treatment including watering and curing, rounding of corners,
54 54 providing grooves where ever necessary with cost, conveyance, 0.00 0.00
royalties of all materials with cost of all labour,labour cess, T&P,
and scaffolding required for the work etc. complete in all respect
as directed by the Engineer in charge.
Fixing granite tiles of approved dimension area above 0.4 sqm
(20mm thick) in floor, treads of steps and landing on 20mm thick
bed of cement mortar (1:4) jointed with neat cement slurry mixed
58 58 with pigment to match the shades of the tiles including rubbing 0.00 0.00
and polishing etc. complete with cost, conveyance, royalties and
taxes of all materials complete in all respects as per direction of
Engineer-in-Charge.
Fixing granite tiles of approved dimension area above 0.1 up to
0.4 sqm (10mm thick) in Dados, treads of steps and landing on
12mm thick cement mortar (1:3) jointed with neat cement slurry
61 61 mixed with pigment to match the shades of the tiles including 0.00 0.00
rubbing and polishing etc. complete with cost, conveyance,
royalties and taxes of all materials complete in all respects as per
direction of Engineer-in-Charge.
Providing full body matt finish vitrified tile flooring using vitrified
tiles having thickness of min 10mm conforming to IS 13755 of
1200x600 (shade to be decided as per Ama Hospital scheme)
(homogeneous) of premium quality in floors, treads on steps and
landings on 20mm thick bed of cement mortar of mix (1:4) laid in
proper slope and gradient with screened and washed sharp sand
for mortar and fixing with neat white cement slurry,grouting the
64 64 joints with neat white cement slurry mixed with required quantities 0.00 0.00
of pigments of approved make to match the shades of the vitrified
tile if required , watering and curing for 21 days, including cost,
conveyance, loading, unloading, royalties and taxes of all
materials, cost of all labour,Labour cess , sundries, T&P required
for the work, complete in all respect as per specification and
direction of Engineer-in-charge.
Providing, fitting, fixing vitrified tiles of premium grade having
thickness 8mm to 10mm confirming to IS 13756 of size 600mm x
600mm Plain (Ivory) of approved as directed by Engineer-in-
charge in dados skirting and risers of steps on 12mm thick
67 67 cement plaster (1:3) jointed with neat cement slurry mixed with 0.00 0.00
pigment to match the shades of the tiles including rubbing and
polishing etc. complete with cost, conveyance, royalties of all
materials all labour,labour cess complete in all respects.
Supplying, fitting & fixing of 8-10 mm thick & size of 600x600
mm Anti-skid vertified floor tile of with veilcraft (VC/FT ) shield(
Scratch free/stain free) with water absorption limit between
0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid
70 70 on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) 0.00 0.00
and filling joints with white cement of approved quality including
cost of all materials, labour T&P etc. required for the work all
complete as per direction of the Engineer-in-charge (for New
Supplying, fitting & fixing of 600mm x 300mm Ceramic wall tiles
having thickness 6.5mm to 7.0 mm confirming to IS 13753 in
dadoes, skirting and risers of steps laid on 12 mm thick cement
mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed
with pigment to match the shades of the tiles etc. complete
including cost of all materials, labour T&P etc. required for the
work all complete as per direction of the Engineer-in-charge
Supplying, fitting and fixing vetrified Industrial tiles in floors of
premium grade having thickness 8mm to 10mm of size 300mm x
300mm confirming to IS 4457 with colour / printed series of
76 76 approved make on 20mm thick bed of C.M. (1:4) including cost of 0.00 0.00
all materials, labour, T&P etc. required for the work in all respect
as directed by the Engineer in charge.
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Providing & Fixinng factory made 100% Solid WPC ( Wood
Polymer Composite )- Door Frame 125 mm x 65 mm Single
Rebated, made from Wood Polymer Composite ( Single Extruded
Process ) material comparising of virgin PVC polymer of K Value
57-60 ( Suspension Grade ), Calcium Carbonate and Natural Fibers
( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives
fabricated with meter Joints after applying PVC solvent Cement &
screwed with full body treaded star headed screws having
minimum frame density of 780 kg/ cbm & an ISO 9001 - 2015
Certified Company, having good screw holding capacity ( Screw
Withdrawal strength of ( Min. 990 N ),Minimum Compressive
Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and
resistance to spread of flame of class A category with property of
being termite / borer proof , water / Moisture Proof & Fire
retardant & Fixed in position with SS Dash Fasteners / Hold Fast
of reuired dia and lenght, , all as per specifications drawings as
directed by the Engineer-In-Charge. Material test certificate and
authentication should be compulsory provided by the
manufacturing company.
Supplying, fitting and fixing of 32mm thick flush door shutter with
approved quality of 30mm thick BWR block board pasted with
1mm thick sunmica on both side of approved design and quality
81 81 including cost of all door fittings and fixtures etc. complete in all 0.00
respect as per the direction of the Engineer-in-Charge.
Factory made FRP( Altematly called GRP) door frame of size
75mm x 100mm fabricated using E - glass chopped strand mat
(CSM) U.V stabilised inopathalic Gel coat and impregnated with
inopathalic resin The thickness of the GRP skins shall not be less
then 2.0 mm . The door frame consists of four segments which
are provided with plug in socket arrrangement in-situ-in mould.
The segments are plugged in and are joined together by means of
srew. The GRP frame shall be provided with wooden
reinforcement on six locations for high srew holding capacity for
fixing metalic hold fast and shall be consolidated by filling with
medium density foam / plaster of paris with fibre reinforcement ,
six number of 260mm x 25mm x 5mm size 'S' shaped M.S flat
hold fast shall be provided with the frame. The material and
process for manufacturing the finish of door frame shall conform
to RV-TIFAC composites Design centre's standards and
specifications . The finish of door frame will be plain colour white
/Ivory/Beige/Light grey / Golden brown / Mahogany/ Teak wood
/sand stone Champagne/Pastel blue or any other colour using
high quality pigment complete in all respect as per specification
and direction of the Engineer in Charge. etc. complete
Factory made GIRID FRP or called GRP sandwich composite
door shutter of 32mm thick laminated with two GRP skin with
good grain finish fabricated using UV stabilised isoppthalic gel
coat and one layer of 450 gsm E-glass chopped strand mat (CSM)
impregnated with ortopathilic resin The thickness of the skins shall
not be less than 1.50mm . Expanded polysryne ( EPS) structural
foam panel of 29 mm tickness and a density of 20kg/cu.mts shall
be used as core material wooden reinforcements made of
sesasoned sal wood block of cross section not less than 28mm x
32mm and also necessary sal wood reinforcements for fitting the
metal fittings such as lower bolts ,aldrops, handles etc. shall be 0.00
provided . A structural adhesive compatible with (EPS)foam shall
be used for bending the core material. the sal wood
reinforcements and the skin The material and process for
manufactuing te door shutter shall conform to RV -TIFAC
components design centre's standards and specification and the
door shutters tested in conformation to IS 4020-1998. The Finish
of door shutter will be plain colour as per specification and
direction of the Engineer in Charge. etc. complete
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supplying and fixing of Powder coated 50-60 microns approved
colour of Aluminium 40mm Casement series Door Unit with
suitable aluminium extrude profiles. the system is designed to
accommodate 12mm clear toughened glass of make-Saint
gobain/AIS/Gardian/modi. the rate quoted inclusive of hardwares
like antilift,roller, Espag lock cum handle,epdm gaskets,T mullion
,Fly Mullion ,bottom adopter ,mid transom ,glazing clip for 12 mm
glass felt along with all accessories etc complete. the gap
between the wall and window will be filled with silicon weather 0.00
sealant in the outer side. Casement Door Outer frame - 40mm x
45.3mm Series x 1.4mm thickness, Fly mullion - 44 x 60 mm x
1.4mm thickness, T Mullion 40 x 78.4mm x 1.4mm thickness,
Transom - 40.28 x 125.8 x 1.75 mm thickness, Bottom adopter -
34.6 x 26 x 1.5mm thickness, including cost of all materials, all
labour, sundries, T&P etc. complete in all respect as per direction
of Engineer-in-Charge
Supplying and installing UPVC- 3 tracks sliding windows and 2
sashes (shutters) with ss mesh sash dimension of 58 mm x 32
mm and sash dimension of 61mm x 37mm for windows with
corners fusion welded, fully reinforced with Galvanized steel of
1.2 mm to 2 mm. The sash will be fitted with 5mm reflective
toughened glass of make - Saint gobain/AIS/Gardian/modi . The
windows must be installed complete with all kinds of ironmongery
(including EPDM gaskets,bridging wedges and glass packers)
and with suitable water draining system. Application of Silicon
sealant from Inside / Outside of Dowcorning / GE or equivalent
including cost of all materials, all labour, sundries, T&P etc.
complete in all respect as per approved drawing & direction of
Engineer-in-Charge.
Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S.
gates, garage door, collapsible gates with top and bottom rails,
steel windows, critical frames for windows, stair case and parapet
railing made out of M.S Square bar/ flat including stair case hand
railing with 40mm. dia G.I.pipe etc. including painting two coats
96 96 over a coat of redoxide primer as per approved drawing and
design with cost of all materials & labour, labour cess, T&P,
sundries etc. complete in all respect as per specification &
direction of the Engineer-in-Charge.
Priming one coat with wall cement primer (water bound) to make
an even finished surface in all floors and heights to wall surface of
approved make and shade including sand papering, applying putty
wherever necessary & cost of scaffolding, staging charges with
cost, conveyance, cost of all labour,labour cess T&P etc.
complete as per the direction of the Engineer-in-charge.
Wall painting two coats with Antifungal weather coat paint (1st
quality) exterior grade of approved make & approved shade over a
coat of primer to make an even finished surface in all floors and
104 104 heights with all scaffolding and staging charges including cost,
conveyance, cost of all labours, T & P, sundries etc. as required
for the work complete in all respect as per the direction of the
Engineer-in-Charge.
Finishing plastered surfaces of walls with cement based wall putty
(Water based) of approved and finishing the surface smooth and
even by sand papering to receive painting in walls, at all heights
108 108 with staging wherever necessary with cost, conveyance, cost of
all labour,labourcess, all T&P etc. required for the work complete
in all respect as per the direction of the Engineer-in-charge.
Painting two coats with plastic emulsion paint with a approved
quality primer to make an even finished surface in all floors and
heights to wall surface of approved make and shade including
sand papering, applying putty wherever necessary & cost of
112 112 scaffolding, staging charges with cost, conveyance, cost of all
labour,labour cess, T&P etc. complete as per the direction of the
Engineer-in-charge.
Engineer-in-charge.
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Painting two coat with approved synthetic enamel paint to new
wood work over a coat of Red oxide primer including cost,
conveyances, royalties, taxes of all materials and cost of all labour
116 116 with T&P required for the work etc. complete as per specification
& direction of Engineer in charge.
Painting two coat with approved synthetic enamel paint to new
iron work over a coat of Red oxide primer including cost,
conveyances, royalties, taxes of all materials and cost of all labour
with T&P required for the work etc. complete as per specification
& direction of Engineer in charge.
Supplying, fitting and fixing of Stainless steel of 304 grade in hand
railing using 50mm dia of 2mm thick circular pipe with Balustrade
of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless
square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in
123 123 stair case as per approved design and specification, buffing,
polishing etc with cost, conveyance, cost of all labour,labour cess,
T&P etc. required for the work complete in all respect as per
direction of the Engineer-in-charge.
Supply and Installation of System comprises of Semi unitized
extruded aluminum Structural Glazing wall panels comprising of
extruded Vertical Aluminium mullions and Horizontal transoms
(JINDAL/HINDALCO/EQUEVALENT ) with super Durable Powder
Coating finish of minimum 60 Microns confirming standards to
withstand wind pressure. The mullions and transoms are installed
on locations as indicated in the architectural drawings. The
framing members provide no structural support for the building
and the Structural Glazing wall is deemed to be a lightweight
façade which is intended to separate the external from the internal
of the building and provides natural light into the building. The
curtain wall system is designed to have internal drainage system
within the extruded sections with 6MM Blue toughened glass.
126 126 Gaskets are employed as water barrier between the aluminum 0.00
gridwork and the glazed sashframe, which are fully drained in the
event of leakage past the primary seal. The external grooves are
covered with application of backer rod with weather sealant of
approved make as indicated in the concept drawing. Fabricating
and supplying Mild Steel ( HDG coated ) Brackets to
accommodate 3 Dimensional movement for achieving perfect
verticality and proper fixing of structural glazing system with the
RCC/ masonry/structural steel framework of building structure,
using stainless steel (chemical/mechanical) anchor fasteners/
bolts, Teflon separator to prevent bimetallic contacts with nuts
and washers etc. of stainless steel Grade 316, of the required
capacity and in required numbers
Supply and Installation of 14 mm GRG Tiles steppe edge ceiling
tile of size 595 x 595 x 14 mm on the edge & 7 mm in the center
having all edges encapsulated with chemical treated paint &
having densified tegular edge ,weight 5 kg/m2 having random
circular semi perforated in dual diameter / Random fissure semi
perforated in variable length which is suspended by using 0.3 mm
thick and 15 mm wide pre coated metal T 15 grid system. The
technical parameters are as follows : Core - GRG Silicate, Fire –
Class 1 & P , Acoustics – NRC 0.5,Climate (degree C, RH) – 50,
99, STC - 30, Termite resistance ,Light reflectance – 85 %,Green
(RC %) – 25, Hygiene (VoC, Clean room) – Low, , Load capacity
(Kg) - Antisag. The T 15 Grid system of 600 x 600 mm module
shall include wall angle(WA 15) with unequal flanges of size 14 x
20 x 3000 mm wide, length 3000 mm, 0.43 mm thick fixed along
the perimeter of wall with the help of nylon sleeves and suitable
129 129 fasteners at 300 mm centers. Then suspend the Main T15 (MT15
W36) having flange width 15 mm /24 mm , height 32/38 mm and
length 3600 mm thickness 0.30 mm from the soffit with help of
soffit cleat and wire at 1200 mm c/c. Cross T15 (CT15 W12) with
flange width 15 mm, height 32 mm and length 1200 mm is then
interlocked into the pre-cut slots in the Main T15 at 600 mm
centers in the direction perpendicular to the Main T15. Finally,
Cross T15 (CT15 W06) having flange width 15 mm, height 32 mm
and length 600 mm are then interlocked into the pre cut slots in
the 1200 mm Cross T15 at 1200 mm centers and in direction
parallel to the Main T15. GRG Tile of size 595 x 595 x 14 mm
thick shall be placed into the grid size of 600 x 600 mm. Ensure
arrow marks behind panels are oriented in one direction to
achieve uniform shade. Test certificate will be submitted after
procurement of materials
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Providing and laying water proofing treatment in sunken portion of
WCs, bathroom etc., by applying cement slurry mixed with water
proofing cement compound consisting of applying : (a) First layer
of slurry of cement @ 0.488 kg/sqm mixed with water proofing
cement compound @ 0.253 kg/ sqm. This layer will be allowed to
air cure for 4hours. (b) Second layer of slurry of cement @ 0.242
132 132 kg/sqm mixed with water proofing cement compound @ 0.126 0.00
kg/sqm. This layer will be allowed to air cure for 4 hours followed
with water curing for 48 hours. The rate includes preparation of
surface, treatment and sealing of all joints,corners, junctions of
pipes and masonry with polymer mixed slurry.
Providing 2.5cm thick Grading Concrete over roof slab with
cement concrete (1:2:2) using 6mm size black hard granite
crusher broken chips and screened & washed sharp sand for
mortar and finished smooth to the rough surface of slab including
135 135 watering and curing with cost, conveyance, royalties of all
materials with cost of all labour, labour cess and T&P required for
the work etc. complete in all respect as directed by the Engineer
Waterproofing application:- Providing and application of two
component polymer modified flexible cementitious waterproofing
coating at a thickness of 1.5 -2.5 mm The membrane should have
Elongation equal or more than: 30%
Crack Bridging ability : Up to 1 mm
Adhesive strength: 1.0 N/mm² @ 28d
137 137 Tensile elongation: 60% @ 20°C 0.00 0.00
Shore A Hardness >85 (between 3 - 7 days)
etc. as per direction of E.I.C (For longer span, in terrace panel of
4m*4m should be done by groove cutting, and filling with PU
139 139 EXTERNAL DEVELOMENT
140 140 DRAINAGE WORKS.
Earth work in excavation of foundation trenches in hard soil
including dressing of sides and levelling the bed up to the
required depth and depositing the excavated materials away
141 141 from the work site within 50m initial lead & 1.5m initial lifts with
sundries & T&P required for the work complete including cost of
all labour,labour cess,T&P,sundries etc. as directed by the
Engineer in charge.
Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
ramming & watering with all leads & lifts including cost of all
labour,T&P completed as directed by the Engineer-in-charge.
Supplying and filling in foundation and plinth with good quality
river sand including watering, ramming with cost, conveyances,
144 144 royalties of all materials and cost of all labour with T&P required Cum 20.21 1595.71 32,249.38
for the work etc. complete as per specification & direction of
Engineer-in-charge
Cement concrete of proportion (1:4:8) in foundation and floors
using 4cm size clean hard black crusher broken granite stone
metal of approved quality and from approved quarry including
hoisting, lowering and laying concrete in layers not exceeding 15
145 145 cm. (6") thick to the required level ramming, watering, curing Cum 20.21 8335.87 1,68,468.01
etc. complete including cost, conveyance, royalties of all
materials with all labour and T&P required for the work etc.
complete in all respect and as per the direction of the Engineer-
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted
in accordance with I.S. 516 using 12 mm. to 20 mm. size black
hard crushed broken granite stone chips and screened and
washed sharp sand for mortar of approved quality from approved
quarry, washed and cleaned ( 20mm. size chips not to exceeds
25 % ) to be mixed in concrete mixture with Portland slag
cement (PSC) including hoisting, lowering, laying and
compaction concrete by using vibrators, watering and curing for
28 days, centering and shuttering then after dismantling and
removing debris from the work site and finishing the exposed
surface smooth providing grooves or beads wherever necessary
including cost, conveyance, loading, unloading, royalties and
taxes of all materials and cost of all labours, sundries, T & P
required of the work etc. complete in all respect as directed by
the Engineer-in-Charge. But excluding cost and conveyance of
M.S. rods or Tor steel and binding wires and labour charges for
straightening, cutting, bending etc. of M.S. rods or tor steel tying
the grills and placing in proper position.
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supplying Cutting, straightening coiled or bent up M.S. Rod or
tor steel of primary steel producers such as SAIL / TATA / RINL /
JINDAL STEEL / SHYAM STEEL/ SEL Tiger (grade Fe-500D) etc.
including bending, binding, welding and jointing if necessary and
tying the grills and placing in position as required for R.C.C.
Work and for providing fan hooks as required, hoisting, lowering,
150 150 laying including cost, conveyances of M.S. Rod or tor steel and Qntl 39.39 10601.47 4,17,592.06
binding wires of 18 to 20 gauge and labour required for the work
for bending, binding and tying the grills in all floors with labour
cess etc. (payment will be made on standard weight of B.I.S. for
M.S. Rods or tor steel only) etc. complete as per specification &
direction of Engineer-in-charge.
151 151 INTERNAL ROAD
Earthwork in excavation in hard soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre
lift and stacking the soil upto a lead of 100 metre and including
152 152 dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
Filling at all depth with available excavated earth (excluding
rock) in trenches, plinth, sides of foundations etc. in layers not
154 154 exceeding 15cm in depth: consolidating each deposited layer by 107.20 181.48 19,455.08
ramming and watering complete (lead upto 100m) as directed by
the Engineer-In-charge. Cum
Supplying of filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools,
taxes etc., all complete as per the specification and direction of
Engineer-In-charge. Cum
Loosening levelling & compacting original ground suppourting
embankment to facilitate a placement of 1st layer of
embankment up to a depth of 150mm mixed with water at OMC
& then and then compacted by rolling as per Clause 300.20 for
embankment construction as per Clause No- 305.3.4 of MoRTH
specifiction. Cum
Providing close graded granular subbase with Grading-lll
Providing and laying 80 mm thick factory made cement concrete
interlocking paver block of M-40 grade made by block making
machine with storng vibratory compaction of approved size,
158 158 design & shape, laid in required colour and pattern over and 400.00 717.91 2,87,164.80
including 75mm thick sand filling.as per drawing, specification
and direction of Engineer-In-charge. Sqm
Construction of cement concrete kerb with top and bottom width
115 and 165 mm respectively, 250 mm high in M 20 grade PCC
on M-10 grade foundation 150mm thick, foundation having
50mm projection beyond kerb stone, kerb stone laid with kerb
laying machine, foundation concrete laid manually, all complete
as per clause 408
Providing & Painting with synthetic enamel paint of approved
brand and manufacture to give an even shade as per the
161 161 instruction of Engineer-In-Charge at all floors and all heights
including all material & labour complete.
163 163 Sub-Total of Civil Works TOTAL 1,87,29,499.73 34,36,909.78
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
164 Plumbing Works
INTERNAL PH WORK-SUPPLY & DRAINAGE PIPING &
166 2 WATER SUPPLY. 0.00 0.00
Supplying, installing, fixing, jointing, testing and commissioning of
approved make. Chlorinated Polyvinyl Chloride pipes (CPVC)
SDR.11 pipes confirming to ASTM standards with necessary
fittings for inetrnal toilet water supply upto 50 dia , and above
50mm dia pipe schedule 80 with fitting shall be schedule 80
ASTM IPS. The fittings and specials such as tees,
elbows,couplers, bends, enlargers etc.,m with CPVC brass
threaded combination / transition specials such as male adapters
brass threaded female adapters, brass FPT Tee, Brass FPT
elbow etc., where connection with metal is to be made including
necessary drilling holes, chasing walls and making the same good
167 3 in cement martor 1:1 restore the same original condition neately 0.00 0.00
as directed by the Engineer in-charge. Joints to be made with
CPVC solvent cement up to 50mm dia as per ASTM D-2846 and
above 50mm dia primer P-70, and solvent confirming to ASTM F-
4931 / 724 All exposed pipe shall be painted with latex paint. (for
shafts, basement ceiling ringmain Terrace & PRM).The rate shall
include necessary GI supports, GI grip bolts, angle brackets,
hangers, supports as with suitable GI U-clamps, bolts, nuts and
washers etc., The clamps shall be painted with two coats of
enamel (approved) paint over a coat of primer etc., complete.
168 4 GROUND FLOOR 0.00 0.00
169 5 20 mm dia C-PVC pipe SDR.11 Mtr 40 330.40 13,216.00
Providing all materials, labour, T&P for fitting & fixing of following
CPVC Ball Valves(CTS Sockets) confirming to IS-15778 with ISI
mark as per ASTM D-2846 in all floor & fixing with the pipes after
cutting the pipes to required shape & size including wastage etc.
175 11 of following nominal diameter, all complete including testing the 0.00 0.00
joints with required water pressure.The cost inclusive of
transportation scaffolding etc. all complete as per specification
excluding GST and direction of Engineer-in-charge.
176 12 25 mm dia CPVC ball valve Each 8 637.77 5,102.13 0.00
177 13 32 mm dia CPVC ball valve Each 5 816.77 4,083.86 0.00
Supplying, installing, testing and commissioning butterfly valves
with standard lever confirming to IS 13039 with necessary
178 14 connecting fittings like flanges ,nuts and bolts etc., complete. 65 Each 1 4796.35 4,796.35
Supplying all materials, labour, T&P and cutting holes through
existing brick work including making good the damages in cement
179 15 mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and Each 20 78.04 1,560.79
fittings etc. all complete as per P.H. specification and direction of
Engineer-in-charge. 250 mm thick wall
Supplying all materials, labour, T&P and cutting hole in R.C.C
floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C
pipes and fittings etc and repairing the holes after insertion of
180 16 pipes etc with cement concrete (1:2:4 ) including finishing Each 14 269.866 3,778.12
complete so as to make it leak proof as per direction of the
Engineer-in-charge.
Supplying, fitting and Outing of PVC pipes as per
(IS:4985-2000) with heavy duty solvent cement (manufacture's
made) joint for basin and sink waste Class-3 (6 kg/sqcm) with
necessary fittings like bends, tees, reducers, sockets etc.
181 17 & specials viz. MS clamp as per design, screws with 0.00
washer includuing cutting holes in floor & walls & making
good the same, cutting chases & filling the same with PCC
(1:2:4) & then cement morter (1:6).
Supplying, fixing and testing PVC soil, waste, Rain and vent pipes
(SWR) supreme confirming to IS13592 : 2013, type B with rubber
ring/Solvent (confirming toIS5382) joint inclusive of allnecessary
specials like bends, tees,offsets, door bends, junctions, cowls,
etc.,laid underfloor/ fixed on walls,and in pipe shafts etc.,
complete.The rate shall include necessary GI supports, GI grip
184 20 bolts, angle brackets, hangers, supports as with suitable GI U- 0.00
clamps, bolts, nuts and washers etc., The clamps shall be painted
with two coats of enamel (approved) paint over a coat of primer
etc., complete.
Providing ,fixing , testing and commissioning of approved make
187 23 PVC vent cowl with necessary accessories etc., complete. 0.00
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supplying all materials, labour, T&P and fixing the following
vitreous china Wash Down Water Closet (European type W.C.
pan) with integral 'p' or 's' trap to the floor with wooden plug and
chromium plated pedestal screws including jointing the trap with
soil pipe in cement mortar (1:1) fixing plastic seat and cover for
wash down water closet with chromium plated brass hinges and
189 25 rubber buffers including polishing etc all complete as per Each 11 6679.98 73,479.78
specification and direction of the Engineer-In-Charge. (EWC with
Wall Hung Cistern, Drainage L Bend Pipe, Gasket and Installation
Kit with PP normal close seat cover, Hinges, Fixing Accessories
and Accessories set, Size: 350x480x395 mm, STrap)
Supplying all materials, labour, T&P and fixing Health Faucet
complete with Chromium plated brass brackets fixed to wooden
plugs with Chromium plated brass screws as per specification and
direction of the Engineer-In-Charge.
Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long
191 27 Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) Each 12 2608.39 31,300.68
Supplying all materials, labour, T&P and fixing standard sized Two
way Bib cock of approved make etc complete including cutting
the wall and making good the damages, including cost of all
192 28 materials complete as per PH specification complete as per Each 12 2749.4 32,992.80
direction of Er-in-charge. 15mm dia CP Two way bib cock with
Supplying all materials, labour, T&P and fixing standard sized
Long way body bib cock of approved make etc complete
including cutting the wall and making good the damages, including
cost of all materials complete as per PH specification complete as
per direction of Er-in-charge. 15mm dia CP Two way bib cock
Supplying all materials, labour, T&P and fixing standard sized
concealed stop cock of approved make etc complete including
cutting the wall and making good the damages, including cost of
194 30 all materials complete as per PH specification complete as per Each 12 1698.374 20,380.49
direction of Er-in-charge. 15mm dia CP Two way bib cock with
Supplying all materials, labour, T&P and fixing standard sized
Chromium Plated brass Towel Rail complete with Chromium
195 31 Plated brass brackets fixed to wooden plugs with Chromium 0.00
Plated brass screws as per specification and direction of the
Engineer in charge
197 33 C.P. Soap Dish holder. Each 12 1439.836 17,278.03
Supplying all materials, labour, T&P and fixing standard sized
198 34 Robe Hook complete with all as per specification and direction of Each 12 924.614 11,095.37
the Engineer in charge.
Supplying all materials, labour T&P and fixing of Under Counter
wash basins of approved make in all floor of approved quality
including cutting the walls & floor and making good the damags
with cement concrete e.t.c including all tsxes,duties,transportation 0.00
e.t.c. All complete as per specification and direction of the
Engineer-In-Charge.
Size : 190X550X430 MM Wash Basin Cat No-FNS-WHT-40701
Supplying all materials, labour T&P and fixing of Waste coupling
201 37 32 mm size Half thread with 80mm height (Half Threaded) Nos 13 728.768 9,473.98
Supplying all materials, labour, T&P and fixing mirror of superior
glass mounted on 6mm thick A.C.sheet or plywood sheet and
fixed to wooden plugs with CP screws and washers complete as
per specification and direction of the Engineer-in-charge.
600mmx450mm size B.E.mirror
Supplying all materials, labour, T&P and fixing standard sized
pillar cock of approved make etc complete including cutting the
wall and making good the damages, including cost of all materials
203 39 complete as per PH specification and direction of Engineering-in- Each 13 2197.16 28,563.08
charge. 15mm dia fus Jaquar,Cat No- PRS-031
Supplying all materials, labour, T&P and fixing standard sized
Chromium Plated soap dispenser complete with Chromium
Plated brass brackets fixed to wooden plugs with Chromium
204 40 Plated brass screws as per specification and direction of the Each 6.5 5298.79 34,442.14
Engineer in charge. soap dispenser jaquar ACN-1137N
Supplying all materials, labour, T&P and fixing standard sized
15mm dia angular Stop cock of approved make etc complete
including cutting the wall and making good the damages, including
205 41 cost of all materials complete as per PH specification complete as Each 25 1471.46 36,786.50
per direction of Er-in-charge. 15mm dia CP angle stop cock with
wall flange .jaquar,Cat No-CQT-23059
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Matrix Set-1 (Wash Basin 46x36 cm with one pair mounting
brackets, EWC & cistern complete with fittings & seat cover, one
206 42 no hinged rail 76 cm and 4 nos of grab rail 60cm) Set- Code- Each 1 76546.60 76,546.60 0.00
Overhead shower 120 mm Round shape Multi Flow (ABS Body)
chrome plated with Gray Face Plate)with Rubit Cleaning System.
207 43 (As per Cat no.OHS-1789 of Jaquar). Each 12 3060.92 36,731.04 0.00
208 44 15 mm dia C.P revolving shower with arm Each 12 1909.24 22,910.88
Supplying and installing ARISTO Plastic Dustbin Black 120 L with
209 45 Lid & Wheel, weight-7.5kg,Size (HxWxD-980x490x550mm), Each 2 5462.22 10,924.44 0.00
Supplying, fixing and testing PVC muilty floor trap without SS
frame and cover 75mm dia outlet fixed on a bed of cement
210 46 concrete with (Heavy duty type) etc., complete. Each 2 304.44 608.88
Supplying, fixing and testing PVC Nahani floor trap without SS
frame and cover 75mm dia outlet fixed on a bed of cement
concrete with (Heavy duty type) etc., complete.
212 48 Supplying, fixing SS floor trap grating . Each 16 548.70 8,779.20 0.00
Providing and fixing stainless Single bowl kitchen sink stainless
steel Bowl Size- 540mm X 410mm, Depth-230mm (Cera, Cat no.-
213 49 B4711501) with C.I. brackets and stainless steel plug 40 mm, Each 0 22546.26 0.00 0.00
including painting of fittings and brackets, cutting and making
good the walls wherever required :
Supplying, Installing, Testing and Commissioning Sink Cock With
Extended Swinging Spout including CP wall flanges, connectors,
214 50 adapters and all other fittings/ accessories required for Each 0 2760.02 0.00 0.00
satisfactory installation complete.
Supplying, fixing and testing PVC soil, waste, Rain and vent pipes
(SWR) supreme confirming to IS13592 : 2013, type B with rubber
ring/Solvent (confirming toIS5382) joint inclusive of allnecessary
specials like bends, tees,offsets, door bends, junctions, cowls,
etc.,laid underfloor/ fixed on walls,and in pipe shafts etc.,
215 51 complete.The rate shall include necessary GI supports, GI grip
bolts, angle brackets, hangers, supports as with suitable GI U-
clamps, bolts, nuts and washers etc., The clamps shall be painted
with two coats of enamel (approved) paint over a coat of primer
etc., complete.
Earthwork in excavation in all types of soil for 200mm dia site
leveling, and forming the bottom surface foundation, pits, trenches
and other civil works upto and including 1.5metre depth and
218 54 stacking the soil upto a lead of 100 metre and including Cum 80 259.60 20,768.00
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
Supplying all materials, labour, T & P and constructing Gully Trap
chamber of the following inside size with 8 cm thick R.C.C.
precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips,
foundation concrete (1:4:8) using 40mm size h.g. metal on bed
219 55 aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside Each 7.00 2220.05 15,540.36
12mm thick cement plastering (1:3) finished with a floating coat of
neat cement including fixing 100mm x100mm size gully trap,
150mm x150mm C.I gratig etc. all complete as per aproved
drawing, specification and direction of Engineer-in-charge.
Supplying all materials, labour, T & P and constructing of
Inspection chamber of the following inside size with 8 cm thick
R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g.
chips, foundation concrete (1:4:8) using 40mm size h.g. metal on
bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside
220 56 12mm thick cement plastering (1:3) finished with a floating coat of Each 15.00 17449.49 2,61,742.29
neat cement including fixing 100mm x100mm size gully trap,
150mm x150mm C.I gratig etc. all complete as per aproved
drawing, specification and direction of Engineer-in-charge.
Supply, installation, testing and commissioning Open well
submersible pump of required drive (Motor HP), having
discharge capacity and pumping head as described below with all
electrical accessories viz.main switch and starter, auto on/off
221 57 system with float arm (with fixed or flexible arm), over load EACH 1 97296.90 97,296.90
protection relay, power cable and control cable from main switch
and starter with auto on-off with dry running protection to
respective motors, earthing having required M.S. galvanised
supporting stay/ clamp etc. complete operational.
Earthwork in excavation in hard soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre
lift and stacking the soil upto a lead of 100 metre and including
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
225 61 ramming & watering with all leads & lifts including cost of all CUM 16.087 181.48 2,919.56
labour,T&P completed as directed by the Engineer-in-charge.
Supplying and filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools,
taxes etc. all complete as per the specification and direction of
Engineer-In-Charge.
Providing and laying plain cement concrete 1:3:6 (1 cement: 3
sand: 6 stone agregate 40mm nominal size) as levelling course
in foundation and plinth etc. including tempering, curring
,shuttering etc.complete all depth and height.
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and 0.00
shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
Cutting, straightening coiled or bent up M.S. Rod or tor steel of
make including bending, binding, welding and joining if necessary
and tying the grills and placing in position as required for R.C.C.
Work and for providing fan hooks as required, hoisting, lowering,
laying including cost, conveyances, taxes of M.S. Rod or tor steel
and binding wires of 18 to 20 gauge and labour required for the
232 68 work for bending, binding and tying the grills in all floors (Linear QTL 17.468 10601.47 1,85,183.02
measurement will be taken and quantity will be calculated basing
on the standard weight of B.I.S. for M.S. Rods or tor steel only.
Wastage if any, including weight of binding wire will not be
considered for measurement) etc. complete as per specification &
direction of Engineer-in-charge.
Providing & applying SikaTop seal 109 hi, Two Component Acrlic
Cementations waterproofing coating over the injected & prepared
surface @ 2.2 Kg/sqm in two coats at the dry areas as per the site
233 69 condition. Lose Plaster to be removed up to the mother substrate SQM 52.5 649.00 34,072.50
present if any in retaining wall prior to the application of
waterproofing coating.
12mm cement plaster on external RCC/brick surfaces in cement
mortar 1:4 (1 cement : 4 coarse sand) with a floating coat of neat
cement punning including necessary scaffolding, curing etc. all
complete at all floors and all heights.
Supplying all materials labour, T&P and fitting and fixing RCPC
235 71 Cover all compete as per specification and direction of the Each 2 1847.29 3,694.58
Engineer in charge.
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Cutting, straightening coiled or bent up M.S. Rod or tor steel
including bending, binding, welding and joining if necessary and
tying the grills and placing in position as required for R.C.C. Work
and for providing fan hooks as required, hoisting, lowering, laying
including cost, conveyances, taxes of M.S. Rod or tor steel and
binding wires of 18 to 20 gauge and labour required for the work
241 77 for bending, binding and tying the grills in all floors (Linear QTL 13.38 10682.42 1,42,930.81
measurement will be taken and quantity will be calculated basing
on the standard weight of B.I.S. for M.S. Rods or tor steel only.
Wastage if any, including weight of binding wire will not be
considered for measurement) etc. complete as per specification &
direction of Engineer-in-charge.
12mm cement plaster to out side of brick surfaces with cement
mortar of mix 1:6 (1 cement : 6 fine sand) including necessary
scaffolding, curing etc. all complete at all floors and all heights.
12mm cement plaster on external RCC/brick surfaces in cement
mortar 1:4 (1 cement : 4 coarse sand) with a floating coat of neat
243 79 cement punning including necessary scaffolding, curing etc. all SQM 36.16 280.84 10,155.17
complete at all floors and all heights.
Priming one coat with wall cement primer (water bound) to make
an even finished surface in all floors and heights to wall surface of
approved make and shade including sand papering, applying putty
244 80 wherever necessary & cost of scaffolding, staging charges with sqm 39.7 102.19 4,056.86
cost, conveyance, taxes of all materials, cost of all labour,labour
cess T&P etc. complete as per the direction of the Engineer-in-
Painting two coats with approved anti-fungal weather seal paints
(ISI) of approved colour, shade on wall surface over a coat of wall
primer(ISI) water bound including sand papering, polishing the
245 81 surface, cost, conveyances of all materials and cost of all sqm 30.54 128.03 3,910.04
labour,labour cess with T&P etc, complete as per specification &
direction of Engineer-in-charge.
2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm &
246 82 down grades size hard granite crusher broken chips on new work sqm 16.16 598.38 9,669.79
in Terrace Floor
Earth work in excavation of foundation in all kinds of soil within Cum 24.705
50m initial lead and 1.5m initial lift including rough dressing &
247 83 breaking clods to maximum 5cm to 7cm and laying in layers not 8,888.41
exceeding 0.30m in depth and as per direction of the Engineer-in-
Charge. 359.78
Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in Cum
all kinds of embankments and road works and ordinary earthwork
in general. 1x6.10x2.70x0.30
Excavation of foundation in laterite rock or any hard rock (other Cum 11.53
than granite or disintegrated rock) removed by chiselling including
dressing and levelling the bed not exceeding 1.50 mtr. in depth
and depositing the soil within initial lead of 50 mtr. and as per
specification approved by the Department.
Supplying all materials, labour, T&P and filling in foundation and Cum 3.29
plinth with sand well watered and rammed including conveyance
250 86 of all materials to worksite, payment of royalty, taxes etc.all 5,249.90
complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement Cum 3.29
concrete (1:3:6) with 4cm size hard granite metal including
251 87 watering, curing, conveyance of all materials to worksite, payment 28,991.88
of royalty, taxes etc all complete as per specification and direction
of the Engineer in charge 8812.12
Supplying all materials, labour, T&P and providing 6mm thick Sqm 39.68
cement plaster (1:4) on RCC work including watering, curing,
252 88 conveyance of all materials to worksite, payment of royalty, taxes 10,235.38
etc all complete as per specification and direction of the Engineer
in charge 257.95
Supplying all materials, labour, T&P and providing cement Sqm 44.96
punning including watering, curing, conveyance of all materials to
253 89 worksite, payment of royalty, taxes etc all complete as per 2,175.16
specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and
smooth centering and shuttering for R.C.C works including false
work and dismantling them after casting including conveyance of
all materials to worksite, payment of royalty, taxes etc all complete
as per specification and direction of the Engineer in charge
255 91 R.C.C floor and roof slabs Sqm 10.05 899.28 9,037.74
256 92 R.C.C beams,columns,girder and bressmer etc. Sqm 70.44 1421.31 1,00,117.08
Supplying all materials, labour, T&P and providing M.S Qntl 14.25
reinforcement for R.C.C work including cutting, bending, binding,
and tying the grills and placing in position including cost of binding
257 93 wire 18 to 20 gauge, conveyance of all materials to worksite, 1,51,071.00
payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supplying all materials, labour, T&P and providing cement Cum 11.76
concrete (1:1:2) with 12mm size hard broken granite chips for
R.C.C works including hoisting, laying, watering, curing,
conveyance of all materials to worksite, payment of royalty, taxes
etc all complete as per specification and direction of the Engineer
in charge 9339.58
Supplying all materials, labour, T&P and providing cement Cum 0.8
concrete (1:2:4) with 12mm size hard broken granite chips
259 95 including watering, curing, conveyance of all materials to worksite, 8,522.15
payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 12mm thick Sqm 5.28
cement plaster (1:4) on brickwork including watering, curing,
260 96 conveyance of all materials to worksite, payment of royalty, taxes 1,361.97
etc all complete as per specification and direction of the Engineer
in charge 257.95
Supplying all materials, labour, T&P and providing brick work with Cum 0.6
Fly ash bricks having crushing strength not less than 75kg/cm²
with dimensional tolerance ± 8 percent in cement mortar (1:4)
261 97 including watering, curing, conveyance of all materials to worksite, 4,239.65
payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge
Supplying all materials, labour, T&P and making MS step iron in Each
20mm diameter MS steel bars and fixing into walls of man
262 98 hole/septic tank duly embedded in cement concrete (1:3:6) 6 333.70 2,002.22
complete as per specification and direction of the Engineer in
Filling in foundation and plinth with excavated materials, moorum Cum 9.84
263 99 including watering and ramming as directed by the Engineer in 1,747.49
Supplying all materials, labour,T&P and providing 25mm thick Sqm 11.55
grading concrete (1:2:2) on roof slab with 6mm size hard granite
chips on new work including watering, curing, conveyance of all
materials to worksite, payment of royalty, taxes etc all complete as
per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing shoring and Sqm 44.01
shuttering foundation trenches, pits etc with close wooden planks
or sheets shuttering etc all complete as per direction of the
Engineer in charge. 385.15
266 102 Dewatering with 5 H.P diesel engine pump during excavation per hour 30 69.62 2,088.60
Supplying all materials, labour, T&P and providing, fitting and Each
fixing U-PVC SWR Tee in wall including filling the recess with
cement concrete (1:3:6) with 12mm size h.g chips all complete
including watering, curing, conveyance of all materials to worksite, 2 284.14 568.29
payment of royalty all complete as per specification and direction
of the Engineer in charge
160mm U-PVC plain Tee
Supplying all materials, labour, T&P and constructing vent base each
268 104 as per P.H.D specification etc all complete. 1 244.14 244.14
Supplying all materials, labour, T&P and fitting and fixing U-PVC
SWR soil waste ventilating pipes and fittings of the following
outside diameter conforming to ISI No 13592/1992 to walls with
nails, bobbins and wooden plugs or laying in trenches including
269 105 jointing with supply of approved rubber lubricant by non-heat 0.00
application method/as per manufacturer's specification, testing,
earthwork in excavation in all kinds of soil and refilling of trenches
as per specification and direction of the engineer in charge.
270 106 110mm diameter U-PVC SWR pipes Mtr 2.2 585.63 1,288.39
Earthwork in excavation in all types of soil for site leveling,
foundation, pits, trenches and other civil works upto and including
1.5metre lift and stacking the soil upto a lead of 100 metre and
272 108 including dewatering, removing slush,shoring and strutting (as
required), complete as per specification and as directed by the
Engineer-In-Charge.
Filling at all depth with available excavated earth (excluding rock)
in trenches, plinth, sides of foundations etc. in layers not
275 111 exceeding 15cm in depth: consolidating each deposited layer by Cum 12.59 181.48 2,284.34
ramming and watering complete (lead upto 100m) as directed by
the Engineer-In-charge.
Supplying of filling sand in foundation and over areas including
watering,ramming, consolidating and dressing, labours, tools,
276 112 taxes etc., all complete as per the specification and direction of Cum 0.9 1595.71 1,436.14
Providing and laying plain cement concrete 1:3:6 (1 cement: 3
sand: 6 stone agregate 40mm nominal size) as levelling course
277 113 in foundation and plinth etc. including tempering, curring Cum 0.45 8812.12 3,965.45
,shuttering etc.complete all depth and height.
Brick work with Fly Ash. Bricks in cement mortar (1:6) in
foundation having crushing strength not less than 75.00 kg/cm2
278 114 immerging the bricks in water not less than six hours before use in Cum 11.96 6792.08 81,250.26
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-250 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
Supplying, straightening, cutting, bending, placing in position and
binding reinforcement steel work in RCC/reinforced brick works as
per drawing and specification including preparation of respective
280 116 bar bending schedule and binding ( Binding wire to be used as Qntl 1.05 10601.47 11,131.55
per the IS code) etc. all complete as per direction of Engineer-in-
charge.Cold Twisted bars, Thermo-Mechanically-treated bars.
Construction of 1 no production wells including scientific source
finding through consolidated and unconsolidated rock with down
281 117 the hamer drilling rig or combination rig with pvc pipe and
installation of submersible pump set with all acessories
Labour for drilling a perfectly vertical bore hole of specified dia for
a specified depth below ground level through consolidated and
unconsolidated rock with down the hole hammer drilling rig or
combination rig as required to suit the site condition as per the
direction of the engineer in charge including use of own rig with its
accessories ,tools and plant and consumables etc for lowering of
200mm/150mm dia G.I.P.V C/M.S casing pipes for housing fitted
282 118 with socket and with or without well screen as for the necessity for
soft ,medium,hard and boulder formation( G.I/P.V.C/M.S casing
pipes if required to prevent collapse of overburden is to be
provided by the contractor including lowering and withdrawing
after completion of the tube well) 200mm dia to 400mm dia in
overburden portion including packing of gravel supplied by the
contractor for 400mm dia bore only
Lowering the following size of G.I/P.V.C/M.S housing pipes with or MTR 60
without slotted pipes as per the necessity form ground level up to
45.00m depth and fitted and fixed up in perfectly vertical position
including cutting and threading of pipes and dotted pipes and
285 121 supplying and fixing all jointing materials, tools and plant etc all 12,977.64
complete and keeping the top of casing pipe threaded including
plugging tube wells to prevent entry of foreign materials
Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having MTR 60
threads in accordance with DIN 2999 part-1/DIN-42225 PART-II
specification length of pipe (laying length) will be 3 mtrs.The pipes
shall be supplied with both external threaded with free socket. The
pipe having external thread at one end i.e. female & or belled end
. The female end having internal thread is to be belled in order to
286 122 accept the male end while jointing pipes with a bore threading 1,66,882.68
shall be provided with a greave at the roof of the male thread
accomodate flexible PVC/Rubber 'O' ring to make the joint water
tight color of the pipe shall be blue The name of the manufacture
along with batch.No class of pipe shall be stranded legibly of each
Supplying all materials, labour, T & P and providing sanitary EACH
sealing by cement concrete grouting of annular space around
287 123 GI/PVC/MS housing pipe upto 5m below ground level (as per 1 1384.97 1,384.97
drawing) to plug the bore hole excluding cost of cement all com
Cleaning & developing the tube well with supply of compressor EACH 1
worked till clear & adequqte discharge is obtained from the tube
288 124 well including supply & use of all necessary equipment & labour 7,771.48
as per directin of the Engineer in charge
Supplying all materials, labours, T&P and providing fitting & fixing
submersible pump with squirrel cage induction type submersible
type submersible electric motor to run on 3 phase /1 phase line
voltage ranging from 320 volt to 450 volt conforming to Si 8034/89
with following specifications with suitable control panel ,jointing
with GI/PVC/HDPE pipes,electrification,testing, commissioning
,trial running, conveyance of all materials to worksite , payment of
taxex etc all complete as per specification & direction of the
Engineer in charge
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
2HP Single phase 3 stage vertical/Horizontal submersible pump EACH 1
290 126 set at head renge of 60 mtr with discharge capacity 200 L P.M 19618.21 19,618.21
with outlet dia 32 mm
291 127 Dol Control panel EACH 1 4494.03 4,494.03
292 128 40mm dia steel short piece EACH 2 238.36 476.72
294 130 50mm size CI bracket PAIR 2 107.73 215.47
296 132 20 mm dia rigid UPVC pipes for cable MTR 65 8.14 529.23
297 133 Steel ropes with cover MTR 35 31.51 1,102.71
298 134 Labour charges for lowering including transportation EACH 1 2360.00 2,360.00
Supplying all materials ,labour, T&P and providing and fixing to MTR 30
wall or celling and floor HDPE pipes and pipe fiting conforming to
IS: 4984/2000(10KGF/SQCM) of the following nominal bore with
299 135 clamps & joining by Fusion welding method including testing 3,532.92
making good the wall celling & floor all complete as per
specificaations 7 direction of the engineer in charge
Supplying all materials, labour, T&P and constructing Bore well
protection chamber of the inside size 650x650x1000hight with
cement concrete (1:3:6) using 40mm size hard granite metal on
foundation, 1st class Fly ash brickwork in cement mortar (1:3),
with base cement concrete (1:2:4) using 12mm size h.g
chips,12mmthick cement plaster (1:4) inside and outside, R.C.C
300 136 cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in Each 1 15423.66 15,423.66
excavation in all kinds of soil and refilling the cavity around the
chamber including watering, curing, conveyance of all materials to
worksite, payment of royalty, taxes etc all complete as per
approved specification and direction of the Engineer in charge.
Earth work in Normal soil within 50m initial lead and 1.5m initial
lift including rough dressing & breaking clods to maximum 5cm to
7cm and laying in layers not exceeding 0.3m in depth and Back
301 137 Filling with excavated soil including manpower and machinary as
per direction of the Engineer-in-Charge.
302 138 (3x2)M+0.5M(For Wall)+0.9 (clearance for construction) CUM 50.160 326.74 16,389.38
Supplying of filling sand in foundation and over areas including CUM
watering,ramming, consolidating and dressing, labours, tools,
304 140 taxes etc.all complete as per the specification and direction of 2.562 1595.71 4,088.22
Engineer-In-charge.
Supplying all materials, labour, T&P and providing cement
concrete (1:4:8) with 4cm size hard granite metal including
305 141 watering, curing, conveyance of all materials to worksite, payment CUM 2.56 8335.87 21,339.84
of royalty, taxes etc all complete as per specification and direction
of the Engineer in charge.
RCC work M-25 grade as per approved designs and drawings
having a minimum compressive strength (in work test) 200 Kg./
Sqcm.in 15 cm. cubes at 28 days after mixing and test conducted
in accordance with I.S.456 and I.S 516 using 12 mm. to 20 mm.
size black hard crusher broken granite stone chips, screened and
washed sharp sand for mortar of approved quality from approved
quarry, to be mixed in concrete mixture with approved quality
cement including hoisting, lowering, laying and compacting
concrete by using vibrators, watering and curing for 28 days,
306 142 centering and shuttering and finishing the exposed surface CUM 33.980 9339.58 3,17,359.00
smooth providing grooves or beads wherever necessary including
cost, conveyance, loading, unloading, royalties and taxes and
cess of all materials, cost of all labours, sundries, T&P & all other
machinaries required for the work but excluding cost and
conveyance of M.S. or Tor steel and binding wires etc.complete in
all respect as per latest specification & direction of the Engineer in
Supplying of all materials and Cutting, Straightening coiled or bent
up M.S. rods or Tor steel welding or jointing if necessary, bending,
binding, tying the grills as required for R.C.C. works, providing fan
hooks where necessary and hoisting, lowering and placing in
proper position according to approved designs and drawings
including cost, conveyance, loading, unloading, taxes of M.S. rods
or Tor steel and binding wires of 18 to 20 gauge required for the
307 143 work and cost of all labour, sundries, T&P and scaffolding QtL 25.360 10601.47 2,68,853.38
complete in all respect as directed by the Engineer in charge
(payment will be made according to the actual weight of M.S. rod /
Tor steel consumed in the work and no separate payment will be
made towards weight of binding wires which is to be borne by the
contractor at his own cost etc complete in all respect as per
direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and providing rigid and
smooth centering and shuttering for R.C.C works including false
work and dismantling them after casting including conveyance of
308 144 all materials to worksite, payment of royalty, taxes etc all complete SQM 240.93 899.28 2,16,663.05
as per specification and direction of the Engineer in charge.
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Providing fitting & fixing of SFRC man hole cover heavy duty
312 148 (560x560) over the harvesty pindi 2 Nos Nos 4 10266.00 41,064.00
Labour for drilling a perfectly vertical bore hole of specified dia for
a specified depth below ground level through consolidated and
unconsolidated rock with down the hole hammer drilling rig or
combination rig as required to suit the site condition as per the
direction of the Engineer in charge including use of own rig with its
accessories, tools and plant and consumables etc for lowering of
200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted
313 149 with socket and with or without well screen as per the necessity MTR 100 826.00 82,600.00
for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S
casing pipes if required to prevent collapse of overburden is to be
provided by the contractor including lowering and withdrawing
after completion of the tube well), 200mm dia to 400mm dia in
overburden portion including packing of gravel supplied by the
contractor for 400mm dia bore only.
Lowering the following size of P.V.C housing pipes with or without
slotted pipes as per the necessity from ground level up to 70.00m
depth and fitted and fixed up in perfectly vertical position including
cutting and threading of pipes and slotted pipes and supplying and
314 150 fixing all jointing materials, tools and plant etc all complete and 0.00
keeping the top of casing pipe threaded including plugging tube
wells to prevent entry of foreign materials.
318 154 Cutting slot in casing pipe for recharge of rain water mtr 100 737.50 73,750.00
319 155 labour for packing gravel outside the tube well 0.00
321 157 Cost of washed gravel Cum 4.054 5310.00 21,526.74
322 158 Sub-Total of Plumbing Works 48,57,370.18 0.00
323 Electrical Works
324 1 Sub-Head I (modular Wiring Items)
Recessed wirring to light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FRLS PVC insulated copper conductor
of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI
marked 6A modular type switch ISI marked (vision) and ceiling
rose ISI marked of modular type G.I box with metallic cover plate
(both side) Panasonic (vision) of suitable size, modular box with
1.5 sq. Mm FRLS PVC insulated single core multistandard copper
325 2 conductor as earth wire including all accessories and connection 0.00 0.00
as per direction of Engineer -in -Charge. . All the switches &
sockets should be warrantied for a replacement period of 2 years
against defects with ncessary test report & Warrnaty certificate to
be submitted to the department for genuinity of product & to avail
free after sales service within warranty period for acceptance of
Supplying ,fixing of 6A Plug on the same board in existing switch
board with complete fitting by 01 no of 6A switch & socket
(modular type)( (flame retradant type)) & other required
accessories of ISI marked as approved as per direction of Engg. -
in -Charge. .(Maximum 02 nos point in one circuit).All the
329 6 switches & sockets should be warrantied for a replacement period Nos 25 231.28 5,782.00
of 2 years against defects with ncessary test report & Warrnaty
certificate to be submitted to the department for genuinity of
product & to avail free aftersales service within warranty period for
acceptance of materials.
Supplying,fixing of 6A Plug on the separate board with complete
fitting by 01 no of 6A switch & socket(modular type)( (flame
retradant type)) with suitable size modular box & cover( flame
retradant type) including supplying of all required accessories of
ISI marked as approved as per direction of engg-in-charge..
.(Maximum 02 nos point in one circuit).All the switches & sockets
should be warrantied for a period of 2 years against
manufacturing defects against which ncessary test report &
Warrnaty certificate to be submitted to the department for
genuinity of product & to avail free aftersales service within
warranty period for acceptance of materials.
Supplying,fixing of 1x16A Plug on the separate board with
complete fitting by 01 no of 16A switch & socket(modular
type)((flame retradant type)) with suitable size modular box &
cover(flame retradant type) including supplying of all required
accessories of ISI marked as approved as per direction of engg-
in-charge.. (For equipement power)All the switches & sockets
331 8 should be warrantied for a replacement period of 2 years against Nos 12 810.66 9,727.92
defects with ncessary test report & Warrnaty certificate to be
submitted to the department for genuinity of product & to avail free
aftersales service within warranty period for acceptance of
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with
complete fitting by 01 no of 16A+1 no 6A switch &
socket(modular type) ( (flame retradant type) with suitable size
modular box & metallic cover plate (both side)( flame retradant
type)including supplying of all required accessories of ISI marked
as approved as per direction of engg-in-charge.. (For equipement
power)(Maximum 02 nos point in one circuit).All the switches &
sockets should be warrantied for a replacement period of 2 years
against defects with ncessary test report & Warrnaty certificate to
be submitted to the department for genuinity of product & to avail
free aftersales service within warranty period for acceptance of
Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with
complete fitting by 01 no of 16A+3 nos 6A switch &
socket(modular type) ( (flame retradant type) with suitable size
modular box & metallic cover plate (both side)( flame retradant
type)including supplying of all required accessories of ISI marked
as approved as per direction of engg-in-charge. (For equipement
333 10 power). (Maximum 02 nos point in one circuit).All the switches & Nos 6 2,351.74 14,110.44
sockets should be warrantied for a replacement period of 2 years
against defects with ncessary test report & Warrnaty certificate to
be submitted to the department for genuinity of product & to avail
free after sales service within warranty period for acceptance of
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable in recessed HMS FRLS PVC conduit of
mentioned size as required as per direction of Engg.-in-Charge.
2 nos single core 1.5 sq. mm copper wire for phase and neutral Mtr 400 187.62 75,048.00
and 01 no of single core 1.5 sq. mm copper wire for earth
continuty conductor. In 20 mm dia non metallic heavy duty
conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable in recessed HMS FRLS PVC conduit of
mentioned size as required as per direction of Engg.-in-Charge.
2 nos single core 2.5 sq. mm copper wire for phase and neutral
335 12 and 01 no of single core 1.5 sq. mm copper wire for earth Mtr 850 204.14 1,73,519.00
continuty conductor in 20 mm dia non metallic heavy duty
conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT )
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable in recessed HMS FRLS PVC conduit of
mentioned size as required as per direction of Engg.-in-Charge.
2 nos single core 4 sq. mm copper wire for phase and neutral and
336 13 01 no of single core 1.5 sq. mm copper wire for earth continuty Mtr 400 225.38 90,152.00
conductor in 20 mm dia non metallic heavy duty conduit .(PDB to
PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable Make-Finolex/Anchor/Polycab/HAVELLS/RR
KABLE/KEI in recessed HMS FRLS PVC conduit of
mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal
as required as per direction of Engg.-in-Charge.
337 14 2 nos single core 6 sq. mm copper wire for phase and neutral and Mtr 75 261.96 19,647.00
01 no of single core 2.5 sq. mm copper wire for earth continuty
conductor in 25 mm dia non metallic heavy duty conduit .(LFDB
TO LBDB/UBDB) (2X6+1X2.5)
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable in recessed HMS FRLS PVC conduit of
mentioned size as required as per direction of Engg.-in-Charge.
338 15 4 nos single core 6 sq. mm copper wire for phase and neutral and Mtr 75 376.42 28,231.50
02 nos of single core 4 sq. mm copper wire for earth continuty
conductor in 32 mm dia non metallic heavy duty conduit.(LFDB
TO LBDB/Medical equipement) (4X6+2X4)
Recessed wiring for circuit/submain wiring with the following
mentioned size PVC FRLS insulated, copper conductor, single
core cable in recessed HMS FRLS PVC conduit of
mentioned size as required as per direction of Engg.-in-Charge.
4 nos single core 10 sq. mm copper wire for phase and neutral
and 02 nos of single core 6 sq. mm copper wire for earth continuty
conductorin 32 mm dia non metallic heavy duty conduit .(LFDB
TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supplying and installation of 25A AC starter Modular type,
Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod
Box of suitable size including modular coveras required as per
direction of Engg.-in-Charge .All the Components should be
340 17 warrantied for a replacement period of 2 years against defects Nos 12 739.86 0.00 8,878.32
with ncessary test report & Warrnaty certificate to be submitted to
the department for genuinity of product & to avail free aftersales
service within warranty period for acceptance of materials.
Supply and fixing CALL bell (Ding dong type) /Buzzer on the
existing switch box/cover.(vision) .as required as per direction of
Engg.-in-Charge.All the Components should be warrantied for a
replacement period of 2 years against defects with ncessary test
341 18 report & Warrnaty certificate to be submitted to the department for Nos 2 252.52 0.00 505.04
genuinity of product & to avail free aftersales service within
warranty period for acceptance of materials.
S/F of Bakelite angle holder/batten holder or equievalant reputed
make A catagory ISI marked as approved )of ISI marked
conforming to IS-1258/1987 in place of ceiling rose as per
direction of Engg.-in-Charge .All the Components should be
342 19 warrantied for a replacement period of 2 years against defects each 6 89.68 538.08 0.00
with ncessary test report & Warrnaty certificate to be submitted to
the department for genuinity of product & to avail free aftersales
service within warranty period for acceptance of materials.
S/F of 5 step type Modular electronic Fan Regulator ISI Marked
343 20 with all connection complete in all respect as per direction of each 40 441.32 17,652.80 0.00
Engineer in charge
Supplying, installation, of exhaust fan of heavy duty 300 mm
sweep 1400 rpm with louvers of exhaust fan in the existing wall,
344 21 including fixing & conntection as required as per direction of Engg.- Nos 3 3,693.40 0.00 11,080.20
in-Charge. Replacement Warranty will be 2 years.
Supplying, installation, of exhaust fan of heavy duty 380 mm
sweep 1400 rpm with louvers of exhaust fan in the existing wall,
including fixing & conntection as required as per direction of Engg.-
345 22 in-Charge. Replacement Warranty will be 2 years. Nos 3 4,573.68 0.00 13,721.04
Supplying, installation, testing and commssioning of 1200 mm
sweep white/milky colour BLDC ceiling fan with aluminium blades
having wattage not more than 28W and air delivery ≥215m3/min
including wiring the down rod of standard length (upto 30 cm) with
1.5 sq mm PVC insulated, copper conductor, single core cable
etc. as required as per direction of Engg.-in-Charge,Replacement
Warranty will be 4 years.(With fan Regulator)
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supplying an fixing of recess/surface mounted 2'x2' 36
W(595mmx595mmx70mm) square shaped LED with lumen
efficacy not less than 130lm/W, CRI not less than 80, CCT of
5700-6500 degree K, THD less than 10%,internal surge
protection of 3 KV, complete with Non integrated isolated
347 24 electronic driver (protects the output /secondary side from any No 76 5,574.32 0.00 4,23,648.32
disturbance on the input / primary side ensuring safe
operation)and all other accessories suitable for operation on140-
270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as
required as per direction of Engg.-in-Charge . The luminaire must
be Replacement Warranty will be 5 years.
Supplying and fixing of Energy efficient surface /recess
mounted square /round shape 18 W LED luminaire of dimension
of consists of white powder coated , die-cast Alluminium
housing with high quality frosted diffuser for glare-free uniform
lighting distribution with wattage not more than 18 watt and lumen
output of 1800 lumens, , CRI not less than 80,CCT of 6000
348 25 degree K,THD less than 10%, with electronic driver, internal surge Nos 30 1,817.20 0.00 54,516.00
protection of 3 KV , L70 B50: 50000 hrs and all other
accessories suitable for operation on 220 V to 240 V supply as
required as per direction of Engg.-in-Charge. (Make:
Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The
luminaire should be Replacement Warranty will be 2 years
SITC of energy efficient LED tube light fittings with decorative
alluminium batten and LED tube light having power rating not
more than 20 watt and lumen output not less than 2200 lumen
complete with electronic driver and all other accessories with
diffuser having 2 years warranty i/c connection etc as required as
per direction of Engg.-in-Charge. The luminaire should be
Replacement Warranty will be 2 years .
SITC of Sleek LED 10 watt mirror light fitting with extruded
polycarbonate housing,High optically efficient diffuser,above wash
basin complete with all accessoriesetc. directly on wall, including
connection with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and earthing etc. as required as per
direction of Engg.-in-Charge.
The luminaire should be Replacement Warranty will be 2 years
Supplying and fixing extra conduit down rod of 20 cm length G.I.
pipe 15 mm dia, heavy gauge including painting etc. as requiredas
required as per direction of Engg.-in-Charge .
(Note : More than 5 cm length shall be rounded to the nearest 10
cm and 5 cm or less shall be ignored)of ISI mark as approved.
Supplying and fixing of following mentioned way, three pole/single
pole and neutral, sheet steel,double door MCB distribution board,
415 volts/240 volts shall be as per IEC 61439-3,integrated door
earthing system offering additional safety to the user,High quality
polyurethane Gasket,the box and cover shall be fabricated to
withstand IK09,the DB should be properly pre-treated with 7 tank
process and duly powder coated, phosphatized with powder
352 29 coated finish, on surface/recess, complete with terminal 0.00 0.00
blocks,with suitable size FR PVC insulated copper conducter up to
terminal blocks, tinned copper busbar, neutral busbar, earth bar,
din bar. Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-
Charge. The Distribution boards should be Replacement
Warranty will be 3 years.
4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC
61439-3 suitable for Flush mounting and Surface mounting with
100A Copper Bus Bar for each phase, with neutral Bus bar, Earth
353 30 Bar & Cable ties for cable management, prefitted masking sheet, Nos 8 5,038.60 40,308.80 0.00
IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-
PH,POWER LOAD) Warranty on DB is 3 years.
Supply and fixing of 12 way DD single pole and neutral sheet
steel MCB distribution board 250V on surface/recess complete
with tinned copper bus bar, neutral bus bar, earth bar, din bar,
detachable gland plate, interconnections, phosphatized and
354 31 powder painted including earthing etc. as required (but with out Nos 5 2,321.06 11,605.30 0.00
MCB/ RCCB/ Isolator) (ALL LIGHT WITH
CORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM LOAD
LIGHT LOAD,POWER LOAD ) Warranty on DB is 3 years.
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C
series, single poles MCB of Schneider- Acti 9/ABB SB 200. the
existing MCB DB complete with connections as per direction of
Engg.-in-Charge.Warranty on MCB is 3 years.
Supplying and fixing 40 Amps rating, 4P, 415 volts, MCB .
Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete
with connections, testing and commissioning etc. as required as
356 33 per direction of Engg.-in-Charge. .(4W TPN BDB IC). The MCB Nos 5 3,499.88 17,499.40 0.00
should be Replacement Warranty will be 3 years
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supplying and fixing 40 Amps rating, 4P, 415 volts, RCCB 30mA .
Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete
with connections, testing and commissioning etc. as required as
per direction of Engg.-in-Charge. .(4W TPN BDB IC). The MCB
should be Replacement Warranty will be 3 years
Supplying and fixing 40Amps DP 240 volts, RCCB 30 mA
Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the
existing MCB DB complete with connections as per direction of
358 35 Engg.-in-Charge. The MCB should be Replacement Warranty Nos 5 5,405.58 27,027.90 0.00
will be 3 years
Supplying and fixing 40Amps DP 240 volts, MCB Schneider- Acti
9/ABB SB 200 in the existing MCB DB in the existing MCB DB
complete with connections as per direction of Engg.-in-Charge.
359 36 The MCB should be Replacement Warranty will be 3 years Nos 5 1,799.50 8,997.50 0.00
Supplying and fixing 63Amps 4P 415 volts MCB Schneider- Acti
9/ABB SB 200 in the existing MCB DB in the existing MCB DB
360 37 complete with connections as per direction of Engg.-in-Charge.(for Nos 5 3,499.88 17,499.40 0.00
power BDB , 4 way TPN BDB IC).The MCB should be
Replacement Warranty will be 3 years
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA
Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the
361 38 existing MCB DB complete with connections as per direction of Mtr 5 6,182.02 30,910.10 0.00
Engg.-in-Charge.(for power BDB , 4 way TPN BDB IC).The MCB
should be Replacement Warranty will be 3 years
Supplying,installation,testing & commissioning of materials and
installation of GI earth plate 600mmx600mmx6mm thick ISI
marked with G. I. nut bolts & washers including cost of burnt
wood charcoal, salt, foreign soil, water pouring arrangements,
362 39 brick masonary enclosure on top with removable RCC cover Nos 3 7,670.00 23,010.00 0.00
complete with labour for excavation of pit in all kinds of soil & rock
as required and as per direction of Engineer-in-charge.
Providing and fixing 6SWG GI wire on surface or in recess for
363 40 loop earthing as required.as per direction of Engg.-in-Charge. Mtr 175 29.50 5,162.50 0.00
Providing and fixing 25mm x 5 mm GI strip on surface or in recess
364 41 for connections etc. as required as per direction of Engg.-in- Mtr 175 179.36 31,388.00 0.00
Supplying of one number PVC insulated armoured and PVC
sheathed XLPE property AL. conductor power cable of 1.1 KV
365 42 grade of following size cables as per direction of Engg.-in- Mtr 85 676.14 57,471.90 0.00
Supplying of one number PVC insulated armoured and PVC
sheathed XLPE property AL. conductor power cable of 1.1 KV
grade POLYCAB/HAVELLS/Finolex or equievalant reputed make
ISI marked as approved of following size cables as per direction
366 43 of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to 0.00 0.00
be submitted to the department for genuinity of product & to avail
free after sales service within warranty period for acceptance of
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 25 SQ. MM direct in ground in the
370 47 trench in one horizental formation including excavation ,sand Mtr 18 185.26 3,334.68 0.00
coushing protection covering and refilling the trench etc as
required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM
direct in ground in the trench in one horizental formation including
371 48 excavation ,sand coushing protection covering and refilling the Mtr 100 210.04 21,004.00 0.00
trench etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size exceeding 120 SQ. MM but not exceeding 400 SQ.
MM direct in ground in the trench in one horizental formation
including excavation ,sand coushing protection covering and
refilling the trench etc as required as per direction of Engg.-in -
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 25 SQ. MM direct in ground in the
EXISTING PIPE etc as required as per direction of Engg.-in - Mtr 35 67.26 2,354.10 0.00
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM
374 51 direct in ground in the EXISTING PIPE etc as required as per Mtr 30 93.22 2,796.60 0.00
direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 25 SQ. MM in open duct etc as required
375 52 as per direction of Engg.-in -charge. Mtr 15 54.28 814.20 0.00
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size exceeding 25 SQ. MM in open duct 400 SQ. MM
direct in ground in the EXISTING PIPE etc as required as per Mtr 15 74.34 1,115.10 0.00
direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 25 SQ. MM in surface with shaddle and
screw etc as required as per direction of Engg.-in -charge. Mtr 15 123.90 1,858.50 0.00
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 120 SQ. MM From 25 SQ. MM in
378 55 surface with shaddle and screw etc as required as per direction of Mtr 15 188.80 2,832.00 0.00
Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv
grade size not exceeding 400 SQ. MM From 120 SQ. MM in
379 56 surface with shaddle and screw etc as required as per direction of Mtr 10 192.34 1,923.40 0.00
Engg.-in -charge.
Supplying and making end termination with brass compression
380 57 gland and aluminium lugs for following mentioned size cable.as 0.00 0.00
per direction of Engg.-in-Charge.
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Providing,fixing and laying of following dia G.I. pipe (medium
385 62 class) in ground complete with G.I fitting incl. trenching(75 mm mtr 15 529.82 0.00 7,947.30
depth)and refilling as per direction of Engg.-in-Charge.
Providing,fixing and laying of following dia HDPE pipe (medium
386 63 class) in ground complete with fitting incl. trenching(75 mm mtr 50 1025.42 0.00 51,271.00
depth)and refilling as per direction of Engg.-in-Charge.
S/I/T&Commissioning of LT indoor floor mounted cubical type
electrical main panel (for both light and power circuit) made out by
2mm CRCA steel sheet duly derusted & painted by simens grey
powder cote paint is designed as G.A drawing. (FOR ALL MAIN
CONNECTED LOAD) BUILDING MAIN)as per direction of Engg.-
in-Charge. Warrentee period of replacement of panel &
387 64 accessories must be 1 year & compelete test certificate must be set 1 116466.00 0.00 1,16,466.00
submitted along with panel board including component list. 2 nos
of 3P+N Type 1+2 SPD 65 kA with 63A 4P MCB,10kA, Cseries
shall be installed in the incomer. 20X10MM Separate Aluminium
Earth bus bar should be installed..
In commer-1-01 number of 160A 4P Icu=100%Ics,36Ka LSIG
388 65 MCCB with micro processor based release Electrical locking for 0.00 0.00
In commer-2-01 number of 100A(100-80) 4P Icu=100%Ics,25kA
389 66 LSIG MCCB with micro processor based release Electrical locking 0.00 0.00
for normal & DG
390 67 In commer-2- 01 no of 100A 4P onload changeover switch 0.00 0.00
Busbar- 04 numbers of 200 Amps al. bus bar busbar duly
391 68 sleeved by color coded PVC sleeve & supported by suitable size 0.00 0.00
Out going- 01 numbers of 63A 4P MCCB,25Ka MCCB with TMR
392 69 based release with adjustable overload ,Icu=100%Ics 0.00 0.00
393 70 Out going- 4 numbers of 32A 4P MCB10kA,C series. 0.00 0.00
394 71 Out going- 6 numbers of 63A 4P MCB 10kA,C series. 0.00 0.00
Instrument- (i) 06 numbers phase indicating lamp with toggle
switch & HRC fuse.
(ii) Digital Meter Displays Current, line to neutral & line to line
396 73 Voltages, frequency & Power Factor. (VA & PF - Phase Wise & 0.00 0.00
Average) (SECURE/ Legrand )
Supplying,fixing of perforated cable trays with horizental & vertical
bends,reducers ,tees,crossover,brakets & other accessories ar
requited confirming to IS-IEC -61537 ,the cable tray shall be
galvanised for corrosion protection confirming to DIN EN
bearing capacity of the Cable Trays should be minimum of
104.8Kg/meter at the span of 1.5Meter as per UL specifications
as required as per direction of Engg.-in-Charge.
Supplying,fixing of perforated cable trays with horizental & vertical
bends,reducers ,tees,crossover,brakets & other accessories ar
requited confirming to IS-IEC -61537 ,the cable tray shall be
galvanised for corrosion protection confirming to DIN EN
bearing capacity of the Cable Trays should be minimum of
104.8Kg/meter at the span of 1.5Meter as per UL specifications
as required as per direction of Engg.-in-Charge.
GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY
WITH JUNCTION with internal dimensions of size 38mm(H) x
225mm(W), of .(With all
399 76 accessories,bend,cover,supporter)WITH REQUIRED SIZED mtr 25 2101.63 0.00 52,540.68
JUNCTION BOX ,COVER CONNECTOR as required as per
direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM
Lightning Protection :- Supply of 8 mm Aluminum Round
400 77 Conductor.Tested as per IEC 62561. as per direction of engineer Mtr 188 175.82 0.00 33,054.16
Supply of Roof conductor holder for parapet- Polyamide
Conductor holder:With M8 female thread or diameter 7mm, M8
Screw to connect the conductor holder.Weather and
temperature resistant from -35 to +90 degree Celsius tested.
Conductor holder @ 1 meter distance.Tested as per IEC 62561.
as per direction of engineer in charge.Make-
OBO/Dehn/ABB/Equivalent
Supply of Polyamide roof cable holder for flat roof:
DIN 48829 Form B1. Closed form with bottom. Filling weight
1Kg (frost-resistant concrete). Sleeve from polyethylene, black
@ 1 meter distance. Tested as per IEC 62561. Make-
OBO/Dehn/ABB/Equivalent
Supply of Connector: For T cross and parallel connectors. Quick
installation using hexagonal bolt M10X30 high-grade hot dip
403 80 galvanised. Tested as per IEC 62561.(2nos/expansion piece ). No 12 239.54 0.00 2,874.48
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supply of 1 mtr vertical air terminal with mounting accessories
on the flat surface to meet the requirements of IS/IEC 62305.
404 81 Tested for Electrical , mechanical and chemical as per IEC No 6 1373.52 0.00 8,241.12
62561. Tested for 100kA lightning current.
Supply of Vertical air terminal with accessories:Providing of Air
terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm
405 82 aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 No 5 3724.08 0.00 18,620.40
corresponds to DIN 48801) Suitable for high wind load.
Tested as per IEC 62561.
Supply for Providing of Stand for Fang Fix system 16 kg with base
406 83 and clamp ,made up of frost resistant concrete and clamp tested No 5 2902.80 0.00 14,514.00
upto 100KA lightning current .
Supply for Providing of Stand for Fang Fix system 16 kg made up
of frost resistant concrete.
Supply of Test Joint (Folding Clamp) suitable to connect 8mm
round conductor and max by 30x3 mm GI strip as specified in
drawing and directed by Engineer.
Tested for 100kA lightning current.
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr
For Test Joint .Internal dimensions: 100x100x48 mm
Supply of Galvanised Steel Flat 30X3 mm thickness from earth
electrode directly in ground as required. Flat conductor Hot
Dipped Galvanized. Tested as per IEC 62561.
Supply for Providing of Cross connector for Flat: Suitable for
411 88 30mm Galvanised steel strip. Installed with 4 nos of hexagonal No 12 297.36 0.00 3,568.32
plate. Tested for 100kA lightning current.
Supply of flat conductor holder- Fit: FL 30, With mounting hole
6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from
412 89 hot-dip galvanised steel, Bottom section from polyamide, black. No 12 307.98 0.00 3,695.76
Tested as per IEC 62561.
Supply for Providing of Plastic Corrosion Protection strip: Approx
413 90 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical No 2 1037.22 0.00 2,074.44
Supply of UL Listed maintenance free ,Low carbon copper
coated earth rod of 3 metre electrode having diameter of 17.2
mm with copper coating thickness of 250micron tested as per
Supply of universal clamp made of SS to connect rod with flat
Supply of Earth conductivity enhancing mineral compound shall be
kg/pit tested as per IEC 62561-7,TCLP tested
Supply of The above arrangements shall be provided with Heavy
417 94 duty earth champer of 5000kg load bearing capacity to ensure the No 2 2559.42 0.00 5,118.84
safety of earthing system
Installation of The above arrangements including all accessories
418 95 as per Direction of Engg. In charge. Job 1 16816.18 0.00 16,816.18
SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing
surface/ recessed steel/ PVC conduit as required: The 4 pair
Unshielded Twisted Pair cable shall be UL Listed,exceeds the
requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4
twisted pairs separated by internal PE Cross Separator. Full
separator. Half shall not be accepted. Rip Cord is must,Insertion
Loss of 32.8 db/100m at 250 MHz ,Cable should support
operating temperature from -20° to +70°C Cable support
Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay
Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ±
15 Ω @100 MHz. and Propagation Delay @250 MHz : 536
ns/100m, ETL Verified 4 connector channel performance up to
700 MHz , RoHS Compliant.
SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or
exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, &
EN50173. The information outlet NEXT, PSNEXT, FEXT,
ELFEXT, PSELFEXT and return loss should be verified for CAT6
@ 250Mhz & CAT6A @ 500Mhz. The information outlet connector
shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors
shall be compatible as per IEEE 802.3af standard for POE
application. The PVC material of Face plate should complie ABS
/UL94-V-O certified.
SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or
exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, &
EN50173. The information outlet NEXT, PSNEXT, FEXT,
ELFEXT, PSELFEXT and return loss should be verified for CAT6
@ 250Mhz & CAT6A @ 500Mhz. The information outlet connector
shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors
shall be compatible as per IEEE 802.3af standard for POE
application. The PVC material of Face plate should complie ABS
/UL94-V-O certified.
SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should
accommodate Cat6 with Rear Cable Management and Front
removable Tooless Information outlet. Should have easy clip
management with labels and clear label covers, Made with of
422 99 Dicast Aluminium Alloy Material and Non Corrosive with Cat6 Nos 2 11585.24 23,170.48
toolless RJ45 x 24 ports with color code front panel with patch
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch
Cords are Factory Tested for Better Quality and Suitable for the
High Speed Data Transmission. Complies to the Standard
ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds
423 100 Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Nos 6 403.56 2,421.36
Reduced Toxic Gasses Emitted During Combustion , RJ45,
8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested
, Transparent Boot Cable Assemblies.
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch
Cords are Factory Tested for Better Quality and Suitable for the
High Speed Data Transmission. Complies to the Standard
ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds
424 101 Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Nos 6 480.26 2,881.56
Reduced Toxic Gasses Emitted During Combustion , RJ45,
8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested
, Transparent Boot Cable Assemblies.
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber
cable through existing conduit: The Fiber should be OS2 Single
Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated
Steel tape Central loose tube. ( Standard Approved: ISO 11801
425 102 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation Mtr 44 145.14 6,386.16
G.652.D - the oder ITU designations A, B and C are also fulfilled /
OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are
fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket.
SITC of Rack mount Draw Type Loaded 6 port LIU available in
Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled
Steel as Raw Material , Consist of Top Cover and Bottom Panel ,
Easy to Assemble and Dissemble , Three Types of Input Holes
Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or
426 103 LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray Nos 2 9848.28 19,696.56
,Adaptor, SM, Duplex SC, PC Type ,Support the TIA/EIA
Telecommunication Wiring Standards. Compact Design ,
Telcordia GR-326-Core .
SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC
Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are
427 104 offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 Nos 2 2715.18 5,430.36
db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db,
UPC>=50db, APC>=60db.
428 105 Supply & Installation of 1000Base LX Fiber Transceiver. Nos 2 6636.32 13,272.64
SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000
Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45
port console port ,Switching Capacity 128 Gbps , Throughput 96
Mpps ,MAC Address 16k , Switch should support IEEE 802.3af
(15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above
, Switch should support DHCP server/relay/client, DHCP
429 106 snooping/option82 , Switch should support Console, Telnet, SSH Nos 1 90907.20 90,907.20
v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP,
NTP, ZTP, SPAN, RSPAN,Switch should support support
ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C
,Power Supply AC: 100-240V.
SITC of 9U/500D Wall Mount Rack with Accessories: The rack
size should be 600W x 500D, Front frame integrated with top,
bottom, front and two side panels for better rigidity and strength,
Front Glass Door with Lock loaded, Compliance with standards
shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC
EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit
430 107 (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Nos 2 13257.30 26,514.60
Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin
Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling
Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager
with Plastic cable loops and H/W screw.
SITC of 24U 600/650D UL Listed Floor mount Rack with Front
perforated door with 3 point lock, Rear mesh door with Cam lock
and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-
Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp
MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable Nos 1 47347.50 47,347.50
2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with
Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray -
Ventilation - 495W - 375D and H/W screw920sets).
Supplying and fixing of following sizes of Heavy class PVC FRLS
conduit ISI marked along with accessories in surface/recess
432 109 including cutting the wall and making good the same in case of
recessed conduit as required as per direction of Engg.-in-Charge
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supply, Installation, Testing & Commissioning of 5MP IP Network
TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8" CMOS
or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at
various resolution & Frame Rates, Min. Illumination required 0.007
lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 50m IR
distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N
Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video
Compression technology such as H.265, H.264 & MJPEG , Fixed
Lens 2.8mm, Field of View FoV H:90°, V:62°, BLC, HLC, WDR,
3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence
435 112 Video Analytics : Video Motion Detection, Tampering, Loitering, Nos 12 17638.64 0.00 2,11,663.68
Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of
Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256,
SSH/Telnet closed, Stream Encryption, 2-Way Audio Full Duplex
Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE (802.3
af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast
Aluminium Housing, Having Operating temp range : –40°C to 60°
C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-
4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA compliant.
Supply, Installation,Testing & Commisioning of Surveliance 10 TB
SITC of 55" UHD IPS Commercial Digital Display for Small Size
Discussion & Chambers: Brightness (440 nits or higher), Dynamic
Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static
(Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms,
437 114 Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Nos 1 110777.22 0.00 1,10,777.22
Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C
Broadcasting System, Commercial Smart UX, webOS version
(webOS 6.0), BIS Certification with 3 years onsite warrenty.
Supply , Installation, testing , commissioning of 32 Channel NVR
with 4 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels
Resolution Display and Recording, H.265 video compression
technology with real time encoding, Full function CMS (Central
monitoring software) supported, Two way audio supported, Dual
streaming technology to encode recording stream and network
438 115 stream separately, Supports remote monitoring on Mobile Client Nos 1 43160.86 0.00 43,160.86
(Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP,
NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search
(accurate to second), Record Snapshot, FTP, Preset Calling,
Email notification supported, Manual/ Alarm/ Motion Detection/
Continuous, CE, FCC, RoHS).
439 116 Sub-Total of Electrical Works 13,95,331.12 18,55,192.46
440 1 Firefighting Works
Supplying, installation, testing and commissioning of Electric
Motor Driven Pressurization Terrace Pump having discharge of
439 2 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor Nos 1 77266.40 0.00 77,266.40
suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base
SITC of FRLS,PVC outer sheateh, steel armoured, aluminium ,
440 3 1100v grade power cables with glands etc.The minimum size of 0.00 0.00
the cables shall as mentioned below,
Supply, installation, testing and commissioning of Floor/Wall
mounted sectionalised, front operated top entry dust and vermin
proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4
wire, 50Hz distribution system fabricated out of 2.0 mm thick
CRCA sheet, insulated busbar with heat shrienkable PVC sleeve,
base frame, complete with all accessories including
interconnections, earth bus etc as required comprising of One (1)-
63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating
lamps with control fuse/ MCB, Digital Voltmeter with selector
switch. DOL starter with O/L and Single Phasing Preventor
suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual
switch and ON/OFF push button.as per direction of engineer in
charge Control panel for fire pumps for auto action.
Supply,Installation,Testing & Commissioning of 'C' Class heavy
duty MS pipe (as per IS 1239 upto 100 mm NB and IS 3589 for
above 100 mm 6.33mm thick) with flanges and fitting such as
bends, tees, reducers, rubber insertions and galvanized nuts and
bolts of following size on surface along wall / shaft with MS
444 7 bracket, suspended from ceiling/ beam with suspenders duly 0.00 0.00
painted with two coats of primer and finished with enamel paint of
approved colour laid through pipe or in trench after wrapping with
hassen cloth after applying coal tar primer as required as per
direction of Engineer-in- charge.
Providing, fixing, testing and commissioning of following size
manually operated hand lever type cast iron double flanged slim
seal wafer type Butterfly valves with EPDM iron disc as per IS-
13095 having pressure ratting PN -1.60 including fixing the same
448 11 with supply of required jointing materials like rubber insertion, MS nos 2 6289.40 0.00 12,578.80
nuts & bolts, paint etc. and testing the joints with required water
pressure etc. all complete as per specification & direction of E.I.C.
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Providing, fitting & fixing of following size cast iron double flanged
type dual plate Non return Valve as per IS- 5312 (Part 1): 2004
with ISI mark of pressure ratting PN-1.60 including fixing the same
with supply of required jointing materials like flanges, rubber
insertion, MS nuts & bolts, paint etc. and testing the joints with
required water pressure etc. all complete as per specification &
direction of Engineer-in-charge.
SITC of Gun metal chrome finished Ball valves with fittings of
screwed end type.
Supply,Installation,Testing & Commissioning of Pressure gauge of
0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable
size with all accessories as per direction of Engineer-in-charge
Supply,Installation,Testing & Commissioning of Pressure Switch
with cut-off bronze ball valves with integral strainer & flare nut
(mixed ends) of suitable size with all accessories as per direction
of Engineer-in-charge.
Supply,Installation,Testing & Commissioning of stainless steel
strainer fabricated out of 1.6 mm thick stainless steel sheet Y
Stainer with 3 mm dia hloes with stainless steel flange as
required. Make-Zoloto/Audco/Leader
Supply,Installation,Testing & Commissioning of Stainless steel
Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single
headed , oblique type, as per IS :5290/93 and as per direction of
Engineer-in-charge.
Supply,Installation,Testing & Commissioning of SS short branch
457 20 pipe with 63 mm male inlet and 19 mm outlet nozzle, as per nos 2 2808.40 0.00 5,616.80
IS:903 and as per direction of Engineer-in-charge.
Supply,Installation,Testing & Commissioning of 63 mm NB and
15meter long RRL Fire Hose fitted with 63mm intstantaneous
458 21 stainless steel male & female SS coupling, complete by GI wire nos 4 6926.60 0.00 27,706.40
binding for Internal Hydrant as per direction of Engineer-in-charge.
Providing supply & fixing of MS Hose Box for of suitable
size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30
mtr long fire hose and a branch pipe, wall mounted type as per
direction of Engineer-in-charge.
Supply,Installation,Testing & Commissioning of Swinging pattern
wall fixing first aid hose reel made from MS sheet and waterways
and moving parts with rubber hose of 20 mm dia. and 30 mtrs.
long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585
Type-I., complete with all accessories as per direction of Engineer-
Providing, fitting and fixing of C.I. 25 MM single air relief valve with
stop cock confirming to IS:14845/2000 with ISI mark for water
works purpose including fixing the same with hydrant riser
including testing & commissioning the system etc. all complete as
per approved specification & direction of Engineer-in-charge.
Providing, fitting & fixing of 2-Way GM fire brigade connection
consisting of 63 mm dia instantaneous type male couplings with
built-in check valves, 150mm dia flanged outlet complete with
462 25 bolts, nuts and rubber insertions confirming to IS:904 with ISI nos 1 6974.98 0.00 6,974.98
mark including testing & commissioning the system etc. all
complete as per apporoved specification & direction of EIC.
Supply,Installation,Testing and Commisioning of ISI marked
463 26 (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg nos 4 9086.00 0.00 36,344.00
with all accessories
Supply,Installation,Testing and Commisioning of ISI marked
464 27 (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all nos 4 3851.52 0.00 15,406.08
Fire buckets (FILLED WITH SAND) round bottom type enamel
465 28 painted, white inside & Red out side and Letter "FIRE" in black out nos 2 5000.84 0.00 10,001.68
side and handle with mounting bracket.
SIGNAGES:-Providing and installing in position the following type
of sign boards made out of 3mm thick flexyle photoluminescent
based glow in dark sheeting with luminous properties enclosed in
a weather proof Uvstabilized film with UV screen printing by
imported links pasted over3 mm thick cast acrylic from front side Sqinch 350 21.24 0.00 7,434.00
with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use,
greenish yellow, glow visible upto 4-6 hr in total darkness
Supply, Installation,Testing & Commisioning of Manual based
Addresable fire alarm control panel , fully networkable with each
loop capable of taking 99 devices, 8 line x 40 character alpha-
numeric liquid crystal display .The panel shall be soft addressable
type . The panel shall be able to give pin point location of all
fire/fault conditions. Further, the panel must be able to
467 30 automatically switch off respective control switches when ever any No. 1 40710.00 0.00 40,710.00
alarm is triggered. The panel shall have integral SMF lead acid
batteries with sealed cells of 24 V capable of running for a
minimum of 8 hours with integral battery charger complete as
required and as per specification. The fire alarm panel shall be
suitable for software integration with BMS & PA system.
Supplying, installing, testing and commissioning of Addressable
Manual Call Point with back box.
Supplying, installing, testing and commissioning of Analogue
Addressable Loop powered Sounder with strobe light.
Digitally signed by DIWAKAR
BoQ : CENTRAL INSTRUMENTATION FACILITY BUILDING(G+1)
Abs. Schedule Non-Schedule Non-Schedule
Head Description of Item Unit Qnty. Schedule Amount
Sr. Rate Rate Amount
Supplying, installing, testing and commissioning of 2C x 1.5 mm²,
armoured, single stand, outer sheathed, FRLS, PVC insulated
copper conductor cable confirming to specified IS standards .
Supplying, installation, testing & commissioning of 2 zone,voice
alarm controller with USB, MP3 player (including 2 zone button
471 34 paging station) with seamless integration facility with main fire Nos. 2 65724.82 0.00 1,31,449.64
alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of digital audio
472 35 amplifier 250 Watt, 25V rms operating at 240 Volt AC Supply Nos. 2 46680.80 0.00 93,361.60
complete as required.
Supplying, installation, testing & commissioning of ceiling/wall
473 36 mounted loud speaker, 3/15 Watt in ABS enclosure complete as Nos. 6 3363.00 0.00 20,178.00
Supplying and drawing of speaker cable Single pair, 2-core, 1.5
sqmm in existing conduits
475 38 Sub-Total of Fire Fightening Works 0.00 7,96,614.46
476 AIR CONDITIONER 0.00 0.00
SITC of Air Cooled Cassette type Air conditioners complete with
Indoor unit(IDU),Out door unit (ODU), R-32/R410A/R-407 Green
Refrigerant, wireless Remote, inbuilt drain pump, suitable for
400/230V, 50Hz, 1/3 phase AC supply. the system shall be
capable of performing cooling, dehumidification, Air circulation,
filtration & ventilation of following capacity with Scroll/ rotary
compressor with min 5 year Original Equipment Manufacturer
(OEM) warranty both compressor and Printed Circuit Board (PCB)
as specified. The system shall be able to deliver 100% of the
rated capacity asper relevant IS Code. The lab testing reports as
per IS: 1391shall be submitted from National Accreditation Board
for Testing and Calibration Laboratories (NABL) accredited as per
International Electro technical Commission (IEC) 17025
standards/ Central Power Research Institute (CPRI)/ Electrical
Research and Development Association (ERDA) with Original
Equipment Manufacturer (OEM) etc. complete as per IS: 1391 as
required. 5 Star Inverter Type- Cooling only (Category I
Supply,installation, testing and commissioning of Air Cooled HI
Wall split type Air conditioners complete with Indoor unit (IDU),
Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant,
wireless Remote control, suitable for working between 180-260V
with low & high voltage cut off and50 hz ,1 phase AC Supply
capable of performing cooling, dehumidification, air circulation of
following capacity with Scroll /rotary compressor. The system shall
be able to deliver 100% of the rated capacity upto 42 Degree
Celsius. Min 5 year Original Equipment Manufacturer (OEM)
warranty both compressor and Printed Circuit Board (PCB). Must
comply : Electrical cable IS694 or IS 9968 temperature sensing
476 2 control IS/ International Electro technical Commission (IEC) 0.00 0.00
60730, hermetic compressor IS 10617, heat exchanger IS 11329,
capacitor IS 2993 and motor IS 12615. Complete as per IS :1391
Part II 2023. The system shall be able to operate up to 50 Degree
C (out door ambient temperature). The indoor outdoor must be
Blue Fin coated. The unit price included with 3mtr Copper piping
with insulation, drain Pipe and copper Power cable. The indoor
should have 4 way swing .
1.5 TR with 5 Star BEE Rating (LG-AS-Q20JWZE/ O General-
2.0 TR with 5 Star BEE Rating (O General-ASGG24CGWA-B/
Daikin-FTKM60XV16)
Supply,installation of hard/soft ISI marked copper refrigerant
piping of size 5/8 inch and 1/4 inch for suction and liquid line with
3 corex4 sqmm FRLS Copper control cable alongwith 25 mm
weather proof closed cell nitrile insulation ,complete with fitting of
bends and other nesessary material to complete the job.
Supply & Installation of interconnecting following sizes of
refrigerant copper pipe work of following outer diameter, insulated
with 25mm thick closed cell electrometric Nitrile rubber tubular
insulation between each set of indoor & outdoor units . The pipe
480 6 dia upto 25 shall be soft seamless & above 25mm dia shall be 0.00 0.00
hard seamless . All piping inside the room shall be properly
fixed/supported with suitable size of clamp/ M.S. hanger and all
external piping shall run in GI. cable tray etc. as reqd.
Supply,installation & fabrication of MS base frame for outdoor unit
483 9 and other nesessary material to complete the job. nos 8 2124.00 0.00 16,992.00
Supply,installation & fabrication of Insulated drain water piping
484 10 from indoor to nearestdrain point separate to all and other mtr 118.5 179.36 0.00 21,254.16
nesessary material to complete the job.
485 11 Supply and fixing of 4kVA Voltage stabilizer no 3 9383.36 0.00 28,150.08
486 12 Supply and fixing of 5kVA Voltage stabilizer no 4 10466.60 0.00 41,866.40
487 13 Sub-Total of Air Conditioner Works TOTAL 0.00 11,79,948.08
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Civil Works - -
Earth work in excavation of foundation trenches in ordinary soil
including dressing of sides and levelling the bed up to the required
depth and depositing the excavated materials away from the work
1 1 site within 50m initial lead & 1.5m initial lifts with sundries & T&P Cum 1420.98 326.74 4,64,294.89
required for the work complete including cost of all labour,labour
cess,T&P,sundries etc. as directed by the Engineer in charge.
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc., in layers not exceeding 20 cm in
depth, consolidating each deposited layers by ramming and
watering, lead up to 50 m and lift up to 1.5 m.
Supplying and filling in foundation and plinth with good quality river
sand including watering, ramming with cost, conveyances,
3 3 royalties of all materials and cost of all labour with T&P required Cum 1050.81 1,595.71 16,76,792.23 -
for the work etc. complete as per specification & direction of
Engineer-in-charge
Providing & applying of pre constructional anti-termite treatment
by drilling 12mm dia holes at distance of 30cm @ junction of wall
& floor about 300mm apart deep enough to reach the soil below &
chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr
water) pumped these holes to soak the soil @ 1 ltr solution of
each hole as per manufactures specification & the holes should
be pluged the filling materials including cost of all materials,
labour,conveyance, T&P , all taxes and hire charges of
machinaries as per direction of Engineer-in-charge.
Cement concrete of proportion (1:3:6) in foundation and floors
using 4cm size clean hard black crusher broken granite stone
metal of approved quality and from approved quarry including
hoisting, lowering and laying concrete in layers not exceeding 15
5 5 cm. (6") thick to the required level ramming, watering, curing etc. Cum 261.29 8,812.12 23,02,519.36 -
complete including cost, conveyance, royalties of all materials with
all labour and T&P required for the work etc. complete in all
respect and as per the direction of the Engineer-in-charge.
Plain cement concrete (1:2:4) using 12mm size black hard
crusher broken granite chips of approved quality from approved
quarry including hoisting, lowering and laying concrete in layers,
watering, curing etc. complete including cost, conveyance,
6 6 royalties of all materials with labour,labour cess and T&P etc. 106.13 10,652.69 11,30,569.57 -
required for the work complete as per the direction of the Engineer-
Fly Ash brick masonry in cement mortar (1:6) in foundation &
plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a
crushing strength of not less than 75 kg./sqcm with dimensional
tolerance ± 2% including splays cutting circular moulding
chamfering and corbelling and similar such type of works with all
7 7 necessary projections watering and curing after immersing the 70.73 6,724.35 4,75,613.13 -
bricks in water at least for six hours before use including cost,
conveyance, and royalties of all materials with all labour,labour
cess and T & P required for the work complete in all respect as
per direction of Engineer-in-Charge
Fly Ash. brick masonry of size 23 cm. x 11 cm. x 8 cm. having
crushing strength not less than 75 kg. Per Sqr. Cm. in cement
mortar of mix (1:6) with approved grade cement and screened &
washed sand for mortar after immersing the bricks for 6 (Six)
hours in water before use in Superstructure including splays
cutting, circular moulding, corbelling, chamfering and similar such
type of works, watering and curing etc. including cost,
conveyance, loading, unloading, royalties and taxes of all
materials, cost of all labour, scaffolding, sundries, T&P required
for the works etc. complete in all respect as directed by the
Engineer-in-charge
Fly Ash brick masonry in cement mortar (1:4) in super structure
using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing
strength of not less than 75 kg./sqcm with dimensional tolerance ±
2% including splays cutting circular moulding chamfering and
corbelling and similar such type of works with all necessary
13 9 projections watering and curing after immersing the bricks in water - -
at least for six hours before use including cost, conveyance,
royalties and taxes of all materials with all labour,labour cess and
T & P required for the work complete in all respect as per direction
of Engineer-in-Charge.
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
17 10 shuttering then after dismantling and removing debris from the - -
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
18 A Ground floor - -
20 b B) Column upto plinth Cum 37.72 20,710.06 7,81,183.54 -
22 d c) Column up to ceiling level Cum 57.57 20,710.06 11,92,278.27 -
27 B 1st floor -
28 a a) Column up to ceiling level Cum 57.57 23,128.35 13,31,499.34 -
33 C 2nd floor - -
34 a a) Column up to ceiling level Cum 57.57 26,023.13 14,98,151.59
39 D Terrace floor - -
40 a a) Column up to ceiling level Cum 20.21 29,488.55 5,95,963.68
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor
steel of primary steel producers such as (grade Fe-500D) etc.
including bending, binding, welding and jointing if necessary and
tying the grills and placing in position as required for R.C.C. Work
and for providing fan hooks as required, hoisting, lowering, laying
including cost, conveyances of M.S. Rod or tor steel and binding
wires of 18 to 20 gauge and labour required for the work for
bending, binding and tying the grills in all floors with labour cess
etc. (payment will be made on standard weight of B.I.S. for M.S.
Rods or tor steel only) etc. complete as per specification &
direction of Engineer-in-charge.
Providing 12 mm thick cement plaster with cement mortar of mix
(1:6) with screened and washed sharp sand for mortar and
finished smooth to the rough surface of walls in all heights after
racking out joints including watering and curing, rounding of
49 12 corners, providing grooves where ever necessary with cost, - -
conveyance, royalties of all materials with cost of all labour,labour
cess, T&P, and scaffolding required for the work etc. complete in
all respect as directed by the Engineer in charge.
Providing 16 mm thick cement plaster with cement mortar of mix
(1:6) with screened and washed sharp sand for mortar and
finished smooth to the rough surface of walls in all heights after
racking out joints including watering and curing, rounding of
54 13 corners, providing grooves where ever necessary with cost, - -
conveyance, royalties of all materials with cost of all labour,labour
cess, T&P, and scaffolding required for the work etc. complete in
all respect as directed by the Engineer in charge.
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Providing 6 mm thick cement plaster with cement mortar of mix
(1:4) with screened and washed sharp sand for mortar and
finished smooth to R.C.C. work after closed deep chipping & slurry
treatment including watering and curing, rounding of corners,
59 14 providing grooves where ever necessary with cost, conveyance, - -
royalties of all materials with cost of all labour,labour cess, T&P,
and scaffolding required for the work etc. complete in all respect
as directed by the Engineer in charge.
Fixing granite tiles of approved dimension area above 0.4 sqm
(20mm thick) in floor, treads of steps and landing on 20mm thick
bed of cement mortar (1:4) jointed with neat cement slurry mixed
64 15 with pigment to match the shades of the tiles including rubbing - -
and polishing etc. complete with cost, conveyance, royalties and
taxes of all materials complete in all respects as per direction of
Engineer-in-Charge.
Fixing granite tiles of approved dimension area above 0.1 up to
0.4 sqm (10mm thick) in Dados, treads of steps and landing on
12mm thick cement mortar (1:3) jointed with neat cement slurry
mixed with pigment to match the shades of the tiles including
rubbing and polishing etc. complete with cost, conveyance,
royalties and taxes of all materials complete in all respects as per
direction of Engineer-in-Charge.
Providing full body matt finish vitrified tile flooring using vitrified tiles
having thickness of min 10mm conforming to IS 13755 of 1200x600
(shade to be decided as per Ama Hospital scheme) (homogeneous)
of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) in
floors, treads on steps and landings on 20mm thick bed of cement
mortar of mix (1:4) laid in proper slope and gradient with screened
and washed sharp sand for mortar and fixing with neat white
cement slurry,grouting the joints with neat white cement slurry
73 a mixed with
Ground required quantities of pigments of approved make to
Providing, fitting, fixing vitrified tiles of premium grade having thickness
8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Plain
(Ivory) of approved make (JOHNSON / SOMANY/ KAJARIA/ RAK) as
directed by Engineer-in-charge in dados skirting and risers of steps on
12mm thick cement plaster (1:3) jointed with neat cement slurry mixed
with pigment to match the shades of the tiles including rubbing and
polishing etc. complete with cost, conveyance, royalties of all materials all
labour,labour cess complete in all respects.
Supplying, fitting & fixing of Chequered tiles in floors of approved
make laid on 20 mm thick cement mortar (1:4) (1 cement : 4
80 19 course sand) and filling joints with slurry including cost of all
materials, labour T&P etc required for the work all complete as per
direction of the Engineer-in-charge
81 a Ground floor Sqm 51.10 752.60 38,458.06
Supplying, fitting & fixing of 8-10 mm thick & size of 600x600 mm
Anti-skid vertified floor tile of with veilcraft (VC/FT ) shield( Scratch
free/stain free) with water absorption limit between 0.08% to 3%
and conforming to IS : 15622:2006 (Group B Ib). laid on 20 mm
82 20 thick cement mortar (1:4) (1 cement : 4 course sand) and filling - -
joints with white cement of approved quality including cost of all
materials, labour T&P etc. required for the work all complete as per
direction of the Engineer-in-charge (for New Work only )
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Supplying, fitting & fixing of 600mm x 300mm Ceramic wall tiles
having thickness 6.5mm to 7.0 mm confirming to IS 13753 in
dadoes, skirting and risers of steps laid on 12 mm thick cement
mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed
86 21 with pigment to match the shades of the tiles etc. complete - -
including cost of all materials, labour T&P etc. required for the
work all complete as per direction of the Engineer-in-charge
Providing and fixing seasoned sal wood work in frames at any
locations including doors, windows,cupboard, clerestory and other
frames fixing in position including cost of hinges, M.S. flat (30mm
x 6mm) hold fasts lugs or dash fasteners of required dia and
length as per drawing / specification, at all floors and all heights.
Supplying, fitting and fixing of 32mm thick flush door shutter with
approved quality of 30mm thick BWR block board pasted with
1mm thick sunmica on both side of approved design and quality
94 23 including cost of all door fittings and fixtures etc. complete in all -
respect as per the direction of the Engineer-in-Charge.
Factory made single leaf rigid FRP(alternately called GRP)
sandwich composite door shutter of 32mm thick laminated with
two GRP skins with wood grain finish fabricated using UV-
stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass
Chopped Strand Mat (CSM) impregnated with orthopthalic
palyester resin. The thickness of the skins shall not be less than
3.00mm Expanded Polystyrone(EPS) structural foam panel of
29mm thickness and a density of 20kg/cu.mtr shall be used as
core material. Wooden reinforcements made of seasoned sal
wood block of cross section not less than 28mmx32mm and also
necessary sal wood reinforcements for fitting the metal fittings
such as tower bolts, aldrops, handles etc shall be provided. A
structural adhesive compatible with (EPS) foam shall be used for
bending the core material, the sal wood reiforcements and the
skins. The material and process for manufacturing the door
shutters shall conform to RV-TIFAC composites Design Centre's
standards and specifications and the door shutters tested in
conformation to IS: 4020-1998. The finish of door shutter will be
plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood
or any other colour using high quality pigments. Three heavy
whight mild steel butt hinges type-I(ISI marked) size 100mm are to
be fitted on one side of shutter with FRP frame of size 45x90mm.
Supplying and fixing of Powder coated 50-60 microns approved
colour of Aluminium 40mm Casement series Door Unit with
suitable aluminium extrude profiles. the system is designed to
accommodate 12mm clear toughened glass of make-Saint
gobain/AIS/Gardian/modi. the rate quoted inclusive of hardwares
like antilift,roller, Espag lock cum handle,epdm gaskets,T mullion
,Fly Mullion ,bottom adopter ,mid transom ,glazing clip for 12 mm
glass felt along with all accessories etc complete. the gap
between the wall and window will be filled with silicon weather
sealant in the outer side. Casement Door Outer frame - 40mm x
45.3mm Series x 1.4mm thickness, Fly mullion - 44 x 60 mm x
1.4mm thickness, T Mullion 40 x 78.4mm x 1.4mm thickness,
Transom - 40.28 x 125.8 x 1.75 mm thickness, Bottom adopter -
34.6 x 26 x 1.5mm thickness, including cost of all materials, all
labour, sundries, T&P etc. complete in all respect as per direction
of Engineer-in-Charge.
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Providing and fixing ISI Marked un-insulated fire rated door
confirming to IS 3614:2021,& tested to IS17518,and shall carry a
unique label with certification/test report number.The fire rating
shall be for 120minutes integrity only.Material shall be galvanised
steel conforming to IS 277, made out of minimum 1.2(18 SWG)
for both frame and shutter, G.I. sheet (zinc coating 120
gsm/sqm).Frame shall be 125 x 55 grooved profile with built in
rebate for fire rated smoke seal. Frame shall be mitered and field
assembled. EPDM smoke seal to be provided along with frame as
standard. Door shutter shall be double skin of 46mm thick with
required fire rating and with vision panel. The infill material shall
be resin bonded honeycomb core. All doorset shall be factory
prepped for receiving appropriate hardware and provided with
necessary reinforcement for hinges, locks and door closers.The
door stiles should be interlocked, for pairs of doors integral
astragals has to be provided on the meeting stile for both active
and inactive leaf. Vision lite, minimum 5mm clear fire rated glass
of size 150 x 750mm (max 0.12sq.mt) on both shutters, fixing with
clipon arrangement.
All frame and door shutter shall be finished polyster powder
coated to minimum 50microns, of approved colour as per the
direction of the engineer incharge. Cost of double leaf doorset
shall include following hardware and accessories as a complete
assembly. SS ball bearing hinges of SS-304 grade of
size100x75x3mm,1no Fire rated mortise dead lock, 55mm BS,
20mm sq. forend, including escutheion, sss as per EN 12209 with
both side key cylinder on active leaf and 2nos flush bolt on the
inactive leaf in case of double leaf door along with dust proof
socket at bottom, 1pairs Pull handle D type, 22dia, CTC 300mm,
back to back per leaf, with spindle,SS 304, SS finish. 1no of Door
closer with spring size of EN 2- 4, as per EN1154 and CE marked
per leaf. Suitable anchor fastners for fixing on different type of wall
construction as per manufacturer recommendation.Once frames
is installed it shall be filled with fire rated PUF. Manufacturer test
certificates shall covers complete door set as a un-latched
assembly with a valid test certificate not exceeding 5 years from
the date of issue of report. for more info refer doors details
drawings, including cost of all materials, all labour, sundries, T&P
etc. complete in all respect as per direction of Engineer-in-
Supplying and installing UPVC- 3 track 3 shutter sliding windows
with Outer dimension - 104 x 49 sash dimension of 61mm x 39mm
for windows with corners fusion welded, fully reinforced with
Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with
5mm reflective toughened glass . The windows must be installed
complete with all kinds of ironmongery (including EPDM
109 28 gaskets,bridging wedges and glass packers) and with suitable -
water draining system. Application of Silicon sealant from Inside /
Outside of Dowcorning / GE or equivalent including cost of all
materials, all labour, sundries, T&P etc. complete in all respect as
per approved drawing & direction of Engineer-in-Charge.
Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S.
gates, garage door, collapsible gates with top and bottom rails,
steel windows, critical frames for windows, stair case and parapet
railing made out of M.S Square bar/ flat including stair case hand
railing with 40mm. dia G.I.pipe etc. including painting two coats
over a coat of redoxide primer as per approved drawing and
design with cost of all materials & labour, labour cess, T&P,
sundries etc. complete in all respect as per specification &
direction of the Engineer-in-Charge.
Priming one coat with wall cement primer (water bound) to make
an even finished surface in all floors and heights to wall surface of
approved make and shade including sand papering, applying
putty wherever necessary & cost of scaffolding, staging charges
with cost, conveyance, cost of all labour,labour cess T&P etc.
complete as per the direction of the Engineer-in-charge.
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Finishing wall with textured exterior paint of required shade :
New work (two or more coats appplied @3.28litre/10sqm)over and
including priming coat of exterior primer applied @2.20kg/10Sqm
128 d Terrace Floor Sqm 205.00 185.85 38,099.25
Finishing plastered surfaces of walls with cement based wall putty
(Water based) of approved make duly approved by Engineer-in-
Charge) and finishing the surface smooth and even by sand
papering to receive painting in walls, at all heights with staging
wherever necessary with cost, conveyance, cost of all
labour,labourcess, all T&P etc. required for the work complete in
all respect as per the direction of the Engineer-in-charge.
133 d Terrace Floor Sqm 962.43 100.54 96,758.86
Painting two coats with plastic emulsion paint with a approved
quality primer to make an even finished surface in all floors and
heights to wall surface of approved make and shade including
sand papering, applying putty wherever necessary & cost of
134 33 scaffolding, staging charges with cost, conveyance, cost of all
labour,labour cess, T&P etc. complete as per the direction of the
Engineer-in-charge.
Painting two coat with approved synthetic enamel paint to new
wood work over a coat of Red oxide primer including cost,
conveyances, royalties, taxes of all materials and cost of all labour
139 34 with T&P required for the work etc. complete as per specification &
direction of Engineer in charge.
Painting two coat with approved synthetic enamel paint to new
iron work over a coat of Red oxide primer including cost,
conveyances, royalties, taxes of all materials and cost of all labour
with T&P required for the work etc. complete as per specification &
direction of Engineer in charge.
147 d Terrace Floor Sqm 6.34 240.13 1,522.42
Supplying, fitting and fixing of Stainless steel of 304 grade in hand
railing using 50mm dia of 2mm thick circular pipe with Balustrade
of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless
square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in
stair case as per approved design and specification, buffing,
polishing etc with cost, conveyance, cost of all labour,labour cess,
T&P etc. required for the work complete in all respect as per
direction of the Engineer-in-charge.
Supply of all materials & laying the waterproofing material of torch
shield P3160(3mm)with its primer 2 coats or equivalent water
proofing material after drying cleaning the concrete surface over
the concrete floor/roof/ balcony/sunken and dado upto 1'6" in wall
including cleaning,applying and mending as per specification
including cost,conveyance,taxes,royalities of all materials to work
Ground complete as per the direction of the Engineer-in-
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Providing 2.5cm thick Grading Concrete over roof slab with
cement concrete (1:2:2) using 6mm size black hard granite
crusher broken chips and screened & washed sharp sand for
mortar and finished smooth to the rough surface of slab including
156 38 watering and curing with cost, conveyance, royalties of all
materials with cost of all labour, labour cess and T&P required for
the work etc. complete in all respect as directed by the Engineer in
Supply and Installation of System comprises of Semi unitized
extruded aluminum Structural Glazing wall panels comprising of
extruded Vertical Aluminium mullions and Horizontal transoms
(JINDAL/HINDALCO/EQUEVALENT ) with super Durable Powder
Coating finish of minimum 60 Microns confirming standards to
withstand wind pressure. The mullions and transoms are installed
on locations as indicated in the architectural drawings. The
framing members provide no structural support for the building
and the Structural Glazing wall is deemed to be a lightweight
façade which is intended to separate the external from the internal
158 39 of the building and provides natural light into the building. The
curtain wall system is designed to have internal drainage system
within the extruded sections with 6MM Blue toughened glass.
Gaskets are employed as water barrier between the aluminum
gridwork and the glazed sashframe, which are fully drained in the
event of leakage past the primary seal. The external grooves are
covered with application of backer rod with weather sealant of
approved make as indicated in the concept drawing. Fabricating
and supplying Mild Steel ( HDG coated ) Brackets to
accommodate 3 Dimensional movement for achieving perfect
verticality and proper fixing of structural glazing system with the
Supply and Installation of 14 mm GRG Tiles steppe edge ceiling tile
of size 595 x 595 x 14 mm on the edge & 7 mm in the center having
all edges encapsulated with chemical treated paint & having
densified tegular edge ,weight 5 kg/m2 having random circular semi
perforated in dual diameter / Random fissure semi perforated in
variable length which is suspended by using 0.3 mm thick and 15
mm wide pre coated metal T 15 grid system. The technical
parameters are as follows : Core - GRG Silicate, Fire – Class 1 & P
, Acoustics – NRC 0.5,Climate (degree C, RH) – 50, 99, STC - 30,
Termite resistance ,Light reflectance – 85 %,Green (RC %) – 25,
Hygiene (VoC, Clean room) – Low, , Load capacity (Kg) - Antisag.
The T 15 Grid system of 600 x 600 mm module shall include wall
angle(WA 15) with unequal flanges of size 14 x 20 x 3000 mm wide,
length 3000 mm, 0.43 mm thick fixed along the perimeter of wall
with the help of nylon sleeves and suitable fasteners at 300 mm
centers. Then suspend the Main T15 (MT15 W36) having flange
width 15 mm /24 mm , height 32/38 mm and length 3600 mm
thickness 0.30 mm from the soffit with help of soffit cleat and wire at
1200 mm c/c. Cross T15 (CT15 W12) with flange width 15 mm,
height 32 mm and length 1200 mm is then interlocked into the pre-
cut slots in the Main T15 at 600 mm centers in the direction
perpendicular to the Main T15. Finally, Cross T15 (CT15 W06)
having flange width 15 mm, height 32 mm and length 600 mm are
then interlocked into the pre cut slots in the 1200 mm Cross T15 at
1200 mm centers and in direction parallel to the Main T15. GRG
Tile of size 595 x 595 x 14 mm thick shall be placed into the grid
164 a size of 600
Ground x 600 mm. Ensure arrow marks behind panels are
Waterproofing application:- Providing and application of two
component polymer modified flexible cementitious waterproofing
coating at a thickness of 1.5 -2.5 mm The membrane should have
Elongation equal or more than: 30%
Crack Bridging ability : Up to 1 mm
Adhesive strength: 1.0 N/mm² @ 28d
167 41 Tensile elongation: 60% @ 20°C -
Shore A Hardness >85 (between 3 - 7 days)
etc. as per direction of E.I.C (For longer span, in terrace panel of
4m*4m should be done by groove cutting, and filling with PU
Sub-Total of Civil Works TOTAL 10,04,64,114.63 1,76,78,492.53
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
169 EXTERNAL DEVELOPMENT WORK
170 A Drainage Work
Earth work in excavation of foundation trenches in hard soil
171 1 including dressing of sides and levelling the bed up to the required Cum 172.90 326.74 56,493.69
depth and depositing the excavated materials away from the work
Filling in foundation trenches and plinth, with excavated earth
including laying the earth in layers not exceeding 23.5 cm thick
ramming & watering with all leads & lifts including cost of all
labour,T&P completed as directed by the Engineer-in-charge.
Supplying and filling in foundation and plinth with good quality river
sand including watering, ramming with cost, conveyances,
173 3 royalties of all materials and cost of all labour with T&P required Cum 29.06 1,595.71 46,371.45
for the work etc. complete as per specification & direction of
Engineer-in-charge
Cement concrete of proportion (1:4:8) in foundation and floors
using 4cm size clean hard black crusher broken granite stone
174 #REF! metal of approved quality and from approved quarry including 29.06 8,335.87 2,42,240.50
hoisting, lowering and laying concrete in layers not exceeding 15
cm. (6") thick to the required level ramming, watering, curing etc. Cum
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
175 4 accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
176 a Drain Bottom slab Cum 23.20 9,779.84 2,26,892.29
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor
steel of primary steel producers such as SAIL / TATA / RINL /
179 5 JINDAL STEEL / SHYAM STEEL/ SEL Tiger (grade Fe-500D) etc. 10,601.47 6,89,837.91
including bending, binding, welding and jointing if necessary and
tying the grills and placing in position as required for R.C.C. Work Qntl 65.07
180 B Internal Road
Earthwork in excavation in hard soil for site leveling, foundation,
pits, trenches and other civil works upto and including 1.5metre
lift and stacking the soil upto a lead of 100 metre and including
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
Filling at all depth with available excavated earth (excluding rock)
in trenches, plinth, sides of foundations etc. in layers not
exceeding 15cm in depth: consolidating each deposited layer by
ramming and watering complete (lead upto 100m) as directed by
the Engineer-In-charge.
Supplying of filling sand in foundation and over areas including
watering, ramming, consolidating and dressing, labours, tools,
taxes etc., all complete as per the specification and direction of
Engineer-In-charge.
Loosening levelling & compacting original ground suppourting
184 4 embankment to facilitate a placement of 1st layer of embankment 42.53 12,758.16
up to a depth of 150mm mixed with water at OMC & then and then
compacted by rolling as per Clause 300.20 for embankment
Providing close graded granular subbase with Grading-lll
Providing and laying 80 mm thick factory made cement concrete
interlocking paver block of M-40 grade made by block making
186 6 machine with storng vibratory compaction of approved size, 717.91 - 14,35,824.00
design & shape, laid in required colour and pattern over and
including 75mm thick sand filling.as per drawing, specification and
direction of Engineer-In-charge.
Construction of cement concrete kerb with top and bottom width
187 7 115 and 165 mm respectively, 250 mm high in M 20 grade PCC 504.62 2,27,076.84
on M-10 grade foundation 150mm thick, foundation having 50mm Rmt 450.00
Providing & Painting with synthetic enamel paint of approved
brand and manufacture to give an even shade as per the
instruction of Engineer-In-Charge at all floors and all heights
including all material & labour complete.
189 Sub-Total of Civil Works TOTAL 47,98,746.67 14,35,824.00
190 Plumbing Works
191 INTERNAL PH WORK
Supplying, installing, fixing, jointing, testing and commissioning of
approved SDR.11 pipes confirming to ASTM standards with
necessary fittings for inetrnal toilet water supply upto 50 dia , and
above 50mm dia pipe schedule 80 with fitting shall be schedule 80
ASTM IPS. The fittings and specials such as tees, elbows,couplers,
bends, enlargers etc.,m with CPVC brass threaded combination /
transition specials such as male adapters brass threaded female
adapters, brass FPT Tee, Brass FPT elbow etc., where connection
193 A GROUND FLOOR - -
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Providing all materials, labour, T&P for fitting & fixing of following
CPVC Ball Valves(CTS Sockets) confirming to IS-15778 with ISI mark
as per ASTM D-2846 in all floor & fixing with the pipes after cutting
the pipes to required shape & size including wastage etc. of
200 2 following nominal diameter, all complete including testing the - -
joints with required water pressure.The cost inclusive of
transportation scaffolding etc. all complete as per specification
excluding GST and direction of Engineer-in-charge.
201 a 25 mm dia CPVC ball valve Each 12.000 637.78 7,653.31 -
202 b 32 mm dia CPVC ball valve Each 9.000 816.78 7,351.05 -
Supplying, installing, testing and commissioning butterfly
valves with standard lever confirming to IS 13039 with
203 3 necessary connecting fittings like flanges ,nuts and bolts etc., Each 4,796.35 -
complete. 65 mm dia.
Supplying all materials, labour, T&P and cutting holes through
existing brick work including making good the damages in cement
mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and
fittings etc. all complete as per P.H. specification and direction of
Engineer-in-charge. 250 mm thick wall
Supplying all materials, labour, T&P and cutting hole in R.C.C floors,
roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and
fittings etc and repairing the holes after insertion of pipes etc with
cement concrete (1:2:4 ) including finishing complete so as to
make it leak proof as per direction of the Engineer-in-charge.
Supplying, fitting and Outing of PVC pipes as per
(IS:4985-2000) with heavy duty solvent cement (manufacture's
made) joint for basin and sink waste Class-3 (6 kg/sqcm) with
necessary fittings like bends, tees, reducers, sockets etc. &
206 6 specials viz. MS clamp as per design, screws with washer
includuing cutting holes in floor & walls & making good the
same, cutting chases & filling the same with PCC (1:2:4) & then
cement morter (1:6).
Supplying, fixing and testing PVC soil, waste, Rain and vent pipes
(SWR) supreme confirming to IS13592 : 2013, type B with rubber
ring/Solvent (confirming toIS5382) joint inclusive of allnecessary
specials like bends, tees,offsets, door bends, junctions, cowls,
etc.,laid underfloor/ fixed on walls,and in pipe shafts etc.,
209 7 complete.The rate shall include necessary GI supports, GI grip -
bolts, angle brackets, hangers, supports as with suitable GI U-
clamps, bolts, nuts and washers etc., The clamps shall be painted
with two coats of enamel (approved) paint over a coat of primer
etc., complete.
Providing ,fixing , testing and commissioning of approved make
212 8 PVC vent cowl with necessary accessories etc., complete. 18.000 180.07 3,241.22
213 SANITARY FIXTURES. -
Supplying all materials, labour, T&P and fixing the following
vitreous china Wash Down Water Closet (European type W.C.
pan) with integral 'p' or 's' trap to the floor with wooden plug and
chromium plated pedestal screws including jointing the trap with Each 30.000 6,679.98
soil pipe in all
Supplying cement mortar
materials, (1:1) fixing
labour, T&P plastic seat Health
and fixing and cover for of
complete with Chromium plated brass brackets fixed to wooden
215 2 plugs with Chromium plated brass screws as per specification and 93,902.04 -
direction of the Engineer-In-Charge.
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Supplying all materials, labour, T&P and fixing standard sized Two
way Bib cock of approved make etc complete including cutting the
wall and making good the damages, including cost of all materials
complete as per PH specification complete as per direction of Er-in-
charge. 15mm dia CP Two way bib cock with Flange.
Supplying all materials, labour, T&P and fixing standard sized
concealed stop cock of approved make etc complete including
217 4 cutting the wall and making good the damages, including cost of all 40,760.98 -
materials complete as per PH specification complete as per
direction of Er-in-charge. 15mm dia CP Two way bib cock with
Supplying all materials, labour, T&P and fixing standard sized Robe
218 5 Hook complete with all as per specification and direction of the 33,286.10
Engineer in charge. Each 36.000 924.61
Supplying all materials, labour T&P and fixing of Under Counter
wash basins of approved make in all floor of approved quality Ech No 21.000 6,877.04
Supplying all materials, labour T&P and fixing of Half pedestal Each
wash basins of approved make in all floor of approved quality
including cutting the walls & floor and making good the damags
220 7 with cement concrete e.t.c including all tsxes,duties,transportation 24.00 8,900.74 2,13,617.76 -
e.t.c. All complete as per specification and direction of the
Engineer-In-Charge.
Supplying, installing, testing and commissioning of approved Each
make White Viterous urinals CI/MS bracket duly painted,
including CP brass waste with dome type grating, CP cast brass
221 8 bottle trap with extension piece, wall flanges,, comprising of all 9.00 2,178.75 19,608.77
plumbing, electronic and electrical items. CP brass flush pipe with
CP brass elbow, CP brass spreader, CP wall flange etc, complete.
Including necessary wall cutting/chasing and making good, as
Supplying all materials, labour, T&P and fixing vitreous china
water closet, squatting pan (Indian type W.C pan/Orissa pattern
squatting pan conforming to IS:2556-part-3-2004) duly embedded
in cement concrete (1:5:10) using 4cm size hard granite metal
including fixing a pair of vitreous china 250mm x 130mm x 30mm
222 9 footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm Each 6.00 4,107.70 24,646.19 -
dia horn) for water closet squatting pan including jointing the trap
with pan in cement mortar (1:1), cutting the floor and mending
good the damages etc all complete as per specification and
direction of the Engineer in charge.Popular indian water closet,
Supplying all materials, labour T&P and fixing of Waste coupling 32
mm size Half thread with 80mm height (Half Threaded) Nos
Supplying all materials, labour, T&P and fixing mirror of superior
glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed
to wooden plugs with CP screws and washers complete as per
specification and direction of the Engineer-in-charge. Each
Supplying all materials, labour, T&P and fixing standard sized pillar
cock of approved make etc complete including cutting the wall and
225 12 making good the damages, including cost of all materials complete 46.00 2,197.16 1,01,069.36 -
as per PH specification and direction of Engineering-in-charge.
Supplying all materials, labour, T&P and fixing standard sized
Chromium Plated soap dispenser complete with Chromium Plated
226 13 brass brackets fixed to wooden plugs with Chromium Plated brass 34.50 5,298.79 1,82,808.26 -
screws as per specification and direction of the Engineer in charge.
soap dispenser Each
Supplying all materials, labour, T&P and fixing standard sized
15mm dia angular Stop cock of approved make etc complete
227 14 including cutting the wall and making good the damages, including 96.00 1,471.46 1,41,260.16 -
cost of all materials complete as per PH specification complete as
per direction of Er-in-charge. 15mm dia CP angle stop cock with Each
Matrix Set-1 (Wash Basin 46x36 cm with one pair mounting
brackets, EWC & cistern complete with fittings & seat cover, one
no hinged rail 76 cm and 4 nos of grab rail 60cm)
Supplying and installing ARISTO Plastic Dustbin Black 120 L with
Lid & Wheel, weight-7.5kg,Size (HxWxD-980x490x550mm), Each
Supplying, fixing and testing PVC muilty floor trap without SS 39.00
frame and cover 75mm dia outlet fixed on a bed of cement
concrete with (Heavy duty type) etc., complete.
Supplying, fixing and testing PVC Nahani floor trap without SS
frame and cover 75mm dia outlet fixed on a bed of cement
231 18 concrete with (Heavy duty type) etc., complete. 6 18.00 218.30 3,929.40 -
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Supplying, fixing SS floor trap grating .
Providing and fixing stainless Single bowl kitchen sink stainless
steel Bowl Size- 540mm X 410mm, Depth-230mm with C.I.
233 20 brackets and stainless steel plug 40 mm, including painting of 1.00 22,546.26 -
fittings and brackets, cutting and making good the walls wherever
required : Each 22,546.26
Supplying, Installing, Testing and Commissioning Sink Cock With
Extended Swinging Spout including CP wall flanges, connectors,
adapters and all other fittings/ accessories required for satisfactory
installation complete. Each 2,760.02
235 EXTERNAL P.H. & SANITARY WORK. -
Supplying, fixing and testing PVC soil, waste, Rain and vent pipes
(SWR) supreme confirming to IS13592 : 2013, type B with rubber
ring/Solvent (confirming toIS5382) joint inclusive of allnecessary
specials like bends, tees,offsets, door bends, junctions, cowls,
etc.,laid underfloor/ fixed on walls,and in pipe shafts etc.,
236 1 complete.The rate shall include necessary GI supports, GI grip - -
bolts, angle brackets, hangers, supports as with suitable GI U-
clamps, bolts, nuts and washers etc., The clamps shall be painted
with two coats of enamel (approved) paint over a coat of primer
etc., complete.
200 mm dia . mtr
Earthwork in excavation in all types of soil for 200mm dia site
leveling, and forming the bottom surface foundation, pits,
trenches and other civil works upto and including 1.5metre depth
239 2 and stacking the soil upto a lead of 100 metre and including Cum 120.00 259.60 31,152.00 -
dewatering, removing slush, shoring and strutting (as required),
complete as per specification and as directed by the Engineer-In-
Supplying all materials, labour, T & P and constructing Gully Trap Each
chamber of the following inside size with 8 cm thick R.C.C. precast
cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation
concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly
Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement
plastering (1:3) finished with a floating coat of neat cement
including fixing 100mm x100mm size gully trap, 150mm x150mm
C.I gratig etc. all complete as per aproved drawing, specification
and direction of Engineer-in-charge.
Supplying all materials, labour, T & P and constructing of Each
Inspection chamber of the following inside size with 8 cm thick
R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g.
241 4 chips, foundation concrete (1:4:8) using 40mm size h.g. metal on 20.00 3,48,989.72 -
bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside
12mm thick cement plastering (1:3) finished with a floating coat of
neat cement including fixing 100mm x100mm size gully trap, 17,449.49
OPEN WELL SUBMERSIBLE PUMPS FOR DOMESTIC WATER
TRANSFER FROM UGR TO OHR
Supply, installation, testing and commissioning Open well
submersible pump of required drive (Motor HP), having discharge
capacity and pumping head as described below with all electrical
accessories viz.main switch and starter, auto on/off system with
float arm (with fixed or flexible arm), over load protection relay,
power cable and control cable from main switch and starter with
auto on-off with dry running protection to respective motors,
earthing having required M.S. galvanised supporting stay/ clamp
etc. complete operational.
244 2 DOMESTIC -
245 3 No. of Pumps : 1 working +1 stand by -
246 4 Flow : 5 cum/hr -
249 EXTRENAL PH WORKS
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Earthwork in excavation in all types of soil for site leveling,
foundation, pits, trenches and other civil works upto and including
1.5metre lift and stacking the soil upto a lead of 100 metre and
251 1 including dewatering, removing slush,shoring and strutting (as 64.06 359.78 23,047.63
required), complete as per specification and as directed by the
Engineer-In-Charge.
Filling at all depth with available excavated earth (excluding rock)
in trenches, plinth, sides of foundations etc. in layers not
exceeding 15cm in depth: consolidating each deposited layer by
ramming and watering complete (lead upto 100m) as directed by
the Engineer-In-charge.
Supplying of filling sand in foundation and over areas including
watering,ramming, consolidating and dressing, labours, tools,
253 3 taxes etc., all complete as per the specification and direction of 3.31 1,595.71 5,281.81
Providing and laying plain cement concrete 1:3:6 (1 cement: 3
sand: 6 stone agregate 40mm nominal size) as levelling course
254 4 in foundation and plinth etc. including tempering, curring 1.68 8,812.12 14,804.36
,shuttering etc.complete all depth and height.
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-25 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
255 5 be mixed in concrete mixture with Portland slag cement (PSC) -
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Cutting, straightening coiled or bent up M.S. Rod or tor steel of
SAIL/ TATA / RINL (VIZAG) make including bending, binding,
welding and joining if necessary and tying the grills and placing in
position as required for R.C.C. Work and for providing fan hooks
as required, hoisting, lowering, laying including cost,
259 6 conveyances, taxes of M.S. Rod or tor steel and binding wires of 19.07 10,601.47 2,02,159.51
18 to 20 gauge and labour required for the work for bending,
binding and tying the grills in all floors (Linear measurement will be
taken and quantity will be calculated basing on the standard
weight of B.I.S. for M.S. Rods or tor steel only. Wastage if any,
including weight of binding wire will not be considered for QTL
12mm cement plaster on external RCC/brick surfaces in cement
plaster 1:6(1 cement : 6 coarse sand) including necessary
scaffolding, curing etc. all complete at all floors and all heights.
Coving 25x25 to be done with with Sika micrete 4/Sika Grout 214
261 8 after applying a slurry coat of Sika Latex in the grove @ 1: 4 : 6( 1 23.20 649.00 15,056.80 -
part Latex: 4 Part Water: 6 Part Cement) by weight.
Providing & applying SikaTop seal 109 hi, Two Component Acrlic
Cementations waterproofing coating over the injected & prepared
surface @ 2.2 Kg/sqm in two coats at the dry areas as per the site
condition. Lose Plaster to be removed up to the mother substrate
present if any in retaining wall prior to the application of
waterproofing coating.
Supplying all materials labour, T&P and fitting and fixing RCPC
263 10 Cover all compete as per specification and direction of the 2.00 1,847.29 3,694.58 -
Engineer in charge. Nos
264 B O.H.T PUMP -
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-250 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
shuttering then after dismantling and removing debris from the
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
Supplying, straightening, cutting, bending, placing in position and
binding reinforcement steel work in RCC/reinforced brick works as
270 2 per drawing and specification including preparation of respective 16.49 10,725.96 1,76,828.24
bar bending schedule and binding (Binding wire to be used as per
the IS code) etc. all complete as per direction of Engineer-In- Qntl
12mm cement plaster on internal & outside smooth side of
RCC/brick surfaces with cement mortar of mix 1:4 (1 cement : 4
fine sand) including neat cement punning & necessary
scaffolding, curing etc. all complete at all floors and all heights.
Coving 25x25 to be done with with Sika micrete 4/Sika Grout 214
after applying a slurry coat of Sika Latex in the grove @ 1: 4 : 6( 1
272 4 part Latex: 4 Part Water: 6 Part Cement) by weight. 27.60 649.00 17,912.40 -
Providing & applying SikaTop seal 109 hi, Two Component Acrlic
Cementations waterproofing coating over the injected & prepared
273 5 surface @ 2.2 Kg/sqm in two coats at the dry areas as per the site 50.09 649.00 32,508.41 -
condition. Lose Plaster to be removed up to the mother substrate
present if any in retaining wall prior to the application of Sqm
SEPTIC TANK coating.
Earth work in excavation of foundation in all kinds of soil within
50m initial lead and 1.5m initial lift including rough dressing &
275 1 breaking clods to maximum 5cm to 7cm and laying in layers not 214.28 326.74 70,014.28
exceeding 0.3m in depth and as per direction of the Engineer-in-
Earth work in excavation of foundation in all kinds of soil with in
1.5m initial lift including dressing and leveling of bed and breaking
276 2 the clods and the excavated materials with in 50m initial lead as 142.38 359.78 51,225.76
per direction of Engineer in charge with 1 extra lift of 1.50 m
over initial laft.
Supplying all materials,labour ,T&P and filling in foundation and
plinth with sand well watered and rammed including cost,
277 3 conveyance of all materials to work site ,payment of royalty,taxes 22.94 1,595.71 36,605.68
etc. all complete as per direction of the Engineer-in -charge
Supplying all materials, labour, T&P and providing cement
concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal
including watering, curing, cost of all materials,conveyance of all 18.08 8,335.87 1,50,712.60
materials to work site with payment of royalty, all taxes etc all
complete as per P.W.D specification and direction of Engineer-in-
Supplying all materials, labour, T&P and providing cement
concrete ( 1:2:4 ) with 12mm size crusher broken hard black
279 5 granite chips including watering, curing,cost of all materials, 8.00 10,652.69 85,221.49
conveyance of all materials to work site with payment of royalty, all
taxes etc all complete as per P.W.D specification and direction of
Engineer-in-charge Cum
Supplying all materials, labour, T&P and providing cement
concrete (1:1:5:3) with 12mm size hard broken granite chips for
280 6 R.C.C works including hoisting, laying, watering, curing, 87.34 10,651.74 9,30,323.15
conveyance of all materials to worksite, payment of royalty, taxes
etc all complete as per specification and direction of the Engineer Cum
Supplying all materials, labour, T&P and providing rigid and
smooth centering and shuttering for R.C.C works including false
281 7 work and dismantling them after casting including conveyance of -
all materials to worksite, payment of royalty, taxes etc all complete
as per specification and direction of the Engineer in charge
282 a RCC floor roof, chajja etc 90.36 890.90 80,501.72 -
283 b RCC Beam, Column, wall etc 265.40 1,403.37 3,72,455.46 -
284 c RCC Plinth bend/ Raft 30.42 672.95 20,471.26 -
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Supplying all materials, labour, T&P and providing M.S
reinforcement for R.C.C work including cutting, bending, binding,
and tying the grills and placing in position including cost of binding
285 8 wire 18 to 20 gauge, conveyance of all materials to worksite, 87.34 10,601.47 9,25,932.74 -
payment of royalty, taxes etc all complete as per specification and
direction of the Engineer in charge
Supplying all materials,labour,T&P and providing 6mm thick
cement plaster(1:4) on RCC work including watering,curing,cost
of all materials, conveyance of all materials to worksite,payment
286 9 of royalty,all taxes etc.all complete as per PWD specification and 151.86 257.95 39,171.98 -
direction of the Engineer-in-charge.
Supplying all materials,labour,T&P and providing 12mm CP (1:4)
with cement punning on brick work including watering,curing,cost
287 10 of all materials, conveyance of all materials to worksite,payment 16.20 261.96 4,243.75 -
of royalty,all taxes etc.all complete as per PWD specification and
direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and providing,fitting and fixing
100mm x 100mm x 100mm SW Tee in wall including filling the
recess with cement concrete (1:3:6) with 12mm size h.g chips all
complete including watering, curing, conveyance of all materials to
worksite, payment of royalty all complete as per specification and
direction of the Engineer in charge Each
Supplying all materials, labour, T&P and making MS step iron in
20mm diameter MS steel bars and fixing into walls of man
289 12 hole/septic tank duly embedded in cement concrete (1:3:6) 24.00 325.33 7,807.82 -
complete as per specification and direction of the Engineer in
Filling in foundation and plinth with excavated materials, moorum
including watering and ramming as directed by the Engineer in
291 D SOAK PIT-2NOS - -
Earthwork in excavation in all types of soil for site leveling,
foundation, pits, trenches and other civil works upto and including
1.5metre lift and stacking the soil upto a lead of 100 metre and
including dewatering, removing slush,shoring and strutting (as
required), complete as per specification and as directed by the
Engineer-In-Charge.
Filling at all depth with available excavated earth (excluding rock)
in trenches, plinth, sides of foundations etc. in layers not
295 2 exceeding 15cm in depth: consolidating each deposited layer by 25.18 181.48 4,569.77 -
ramming and watering complete (lead upto 100m) as directed by
the Engineer-In-charge. Cum
Supplying of filling sand in foundation and over areas including
watering,ramming, consolidating and dressing, labours, tools,
296 3 taxes etc., all complete as per the specification and direction of 1.80 1,595.71 2,872.29 -
Providing and laying plain cement concrete 1:3:6 (1 cement: 3
sand: 6 stone agregate 40mm nominal size) as levelling course
297 4 in foundation and plinth etc. including tempering, curring 0.90 8,812.12 7,930.91 -
,shuttering etc.complete all depth and height.
Brick work with Fly Ash. Bricks in cement mortar (1:6) in
298 5 foundation having crushing strength not less than 75.00 kg/cm2 23.92 6,792.08 1,62,466.55 -
immerging the bricks in water not less than six hours before use in Cum
Providing, lifting, hoisting and laying Reinforced cement concrete
of M-250 grade as per approved designs and drawings having a
minimum compressive strength (in work test) 250 Kg. / Square
cm. in 15 cm. cubes at 28 days after mixing and test conducted in
accordance with I.S. 516 using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and screened and washed
sharp sand for mortar of approved quality from approved quarry,
washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to
be mixed in concrete mixture with Portland slag cement (PSC)
including hoisting, lowering, laying and compaction concrete by
using vibrators, watering and curing for 28 days, centering and
299 6 shuttering then after dismantling and removing debris from the - -
work site and finishing the exposed surface smooth providing
grooves or beads wherever necessary including cost,
conveyance, loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-
Charge. But excluding cost and conveyance of M.S. rods or Tor
steel and binding wires and labour charges for straightening,
cutting, bending etc. of M.S. rods or tor steel tying the grills and
placing in proper position.
Digitally signed by DIWAKAR
BoQ : ACADEMIC(SCIENCE BLOCK) BLOCK (G+2)
Abs. Non-Schedule
Head Description of Item Unit Qnty. Schedule Rate Schedule Schedule Amount
Supplying, straightening, cutting, bending, placing in position and
binding reinforcement steel work in RCC/reinforced brick works as
per drawing and specification including preparation of respective
bar bending schedule and binding ( Binding wire to be used as
per the IS code) etc. all complete as per direction of Engineer-in- 2.10 10,601.47 22,263.10 -
charge.Cold Twisted bars, Thermo-Mechanically-treated bars.
302 E BORE WELL-1NOS - -
Construction of 1 no production wells including scientific source
finding through consolidated and unconsolidated rock with down
303 1 the hamer drilling rig or combination rig with pvc pipe and - -
installation of submersible pump set with all acessories
Labour for drilling a perfectly vertical bore hole of specified dia for
a specified depth below ground level through consolidated and
unconsolidated rock with down the hole hammer drilling rig or
combination rig as required to suit the site condition as per the
direction of the engineer in charge including use of own rig with its
accessories ,tools and plant and consumables etc for lowering of
200mm/150mm dia G.I.P.V C/M.S casing pipes for housing fitted
with socket and with or without well screen as for the necessity
305 a Drilling of 200mm dia bore - -
307 c Drilling of 150mm dia bore - -
Lowering the following size of G.I/P.V.C/M.S housing pipes with
or without slotted pipes as per the necessity form ground level up
309 3 to 45.00m depth and fitted and fixed up in perfectly vertical 60.00 216.29 12,977.64 -
position including cutting and threading of pipes and dotted pipes
and supplying and fixing all jointing materials, tools and plant etc MTR
Supplying and keeping
polyvinyl thepipes
chloride top ofascasing pipe threaded having
per ASTM-D-1785-89
threads in accordance with DIN 2999 part-1/DIN-42225 PART-II
specification length of pipe (laying length) will be 3 mtrs.The
pipes shall be supplied with both external threaded with free
socket. The pipe having external thread at one end i.e. female &
or belled end . The female end having internal thread is to be MTR
Supplying all materials, labour, T & P and providing sanitary
311 5 sealing by cement concrete grouting of annular space around 1.00 1,384.97 1,384.97 -
GI/PVC/MS housing pipe upto 5m below ground level (as per
drawing) to plug the bore hole excluding cost of cement all com
Cleaning & developing the tube well with supply of compressor
worked till clear & adequqte discharge is obtained from the tube
well including supply & use of all necessary equipment & labour
as per directin of the Engineer in charge EACH
Supplying all materials, labours, T&P and providing fitting &
fixing submersible pump with squirrel cage induction type
313 7 submersible type submersible electric motor to run on 3 phase /1 - -
phase line voltage ranging from 320 volt to 450 volt conforming
to Si 8034/89 with following specifications with suitable control
2HP Single phase 3 stage vertical/Horizontal submersible pump
314 8 set at head renge of 60 mtr with discharge capacity 200 L P.M 1.00 19,618.21 19,618.21 -
with outlet dia 32 mm EACH
316 b 40mm dia steel short piece 2.00 238.36 476.72 -
318 d 50mm size CI bracket 2.00 107.73 215.47 -
320 f 20 mm dia rigid UPVC pipes for cable 65.00 8.14 529.23 -
321 g Steel ropes with cover 35.00 31.51 1,102.71 -
322 h Labour charges for lowering including transportation 1.00 2,360.00 2,360.00 -
Supplying all materials ,labour, T&P and providing and fixing to
wall or celling and floor HDPE pipes and pipe fiting conforming to
IS: 4984/2000(10KGF/SQCM) of the following nominal bore with 30.00 117.76 3,532.92
clamps & joining by Fusion welding method including testing MTR
Borewellgood the wall celling & floor all complete as per
Supplying all materials, labour, T&P and constructing Bore well
protection chamber of the inside size 650x650x1000hight with
325 1 cement concrete (1:3:6) using 40mm size hard granite metal on 1.00 15,423.66 15,423.66 -
foundation, 1st class Fly ash brickwork in cement mortar (1:3),
with base cement concrete (1:2:4) using 12mm size h.g
326 F RECHARGE PIT-8NOS - -
Digitally signed by DIWAKAR
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT MSCBU.pdf
Tender Document
BoQ.pdf
Tender Document
Integrity Pact.pdf
Tender Document
Physical Milestone.pdf
Tender Document
Technical Specification.pdf
Tender Document
Tender Drawings.pdf
Tender Document
GCC Construction Works 2026 Contracting.pdf
Tender Document
Technical Circulars upd upto 33.pdf
Tender Document
List of Approved Makes.pdf
Tender Document
SCC.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].