Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC 11 97 SADALATLIGUDA CHOWDARIGUDA HYDERABAD TELANGANA 500088 | MEDCHAL MALKAJGIRI | TELANGANA | 500088 | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹35.5 L+₹1.9 L (5.56%)Rejected-Finance | L2 | Rejected-Finance High rate | |
| 3 | L3₹36.4 L+₹2.8 L (8.21%)Rejected-Finance | L3 | Rejected-Finance High rate | |
| 4 | L4₹36.4 L+₹2.8 L (8.44%)Rejected-Finance | L4 | Rejected-Finance High rate | |
| 5 | L5₹36.5 L+₹2.9 L (8.49%)Rejected-Finance | L5 | Rejected-Finance High rate |
Tender Value
₹48.7 L
EMD Value
₹97,400
Closing Date
4 May 2021, 6:00 pmClosed
GE NDA KHADAKWASLA
GE NDA KHADAKWASLA
REPAIR/MAINT OF INTERNAL ELECTRIFICATION INCLUDING FANS AND GEYSERS AT JCOS, NCOS AND FOLLOWERS MD ACCN INCLUDING OTMS AT ZONE C AT NDA KHADAKWASLA
2021_MES_436771_1
GE (K) 04 OF 2021-2022
Open Tender
Civil Works
Item Rate
270 days
GE NDA KHADAKWASLA
As per Tender documents
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADAKWASLA
₹97,400
Yes
10 Jul 2021
16 Apr 2021
6 May 2021
17 Apr 2021
4 May 2021
27 Apr 2021
18 Apr 2021 - 24 Apr 2021
Amount
Repair / maintenance of internal light fitting of any type like tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the compenents / parts, wiring, switch, sockets etc, identifying and replacing the defective components like tube rod, side holders, holders, lamps etc all as directed by Engr-in-charge. Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like capacitor, holder, connector, connection wire, bearing etc. replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following day before 0900hrs to the JE E/M. (iv) The contractor shall rectify the defects and make the light fittings functional within 24 hours from the time the list of defective lights is handed over to him / his rep by the concerned JE E/M. In case the light fitting is not made functional for whatsoever reason within the specified time limit, an amount of Rs 50/- per such defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairer for each at JCOs,ORs,Followers and OTM Accn area. (v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the S&F in replacement of items here-in-below.
Supply only following spares for light fittings of branded make as mentioned in the list of make enclosed with Particular specifications for replacement :- Spring loaded G13 side holders (set of 2) suitable for 36/40W FTL fitting
Ditto all as per item No. 2 above but PVC / polycarbonate lamp holders batten/Angle type
S&F in replacement modular step type fan regulator suitable for 1200/1400 mm sweep fan, 2 module Make- Vinay/Anchor Roma/Legrand
S&F in replacement modular switch piano type 6 amps one way one module Make - Vinay/ Anchor Roma/Legrand
S&F in replacement modular switch piano type 16 amps one way one module Make - Vinay/ Anchor Roma/Legrand
S&F in replacement modular Socket, 6A - 2/3 pin 2 module Make - Vinay/Anchor Roma
S&F in replacement modular Socket, 6/16A - 2/3 pin 2 module Make - Vinay/Anchor Roma
S&F in replacement of socket 5/6 Amps flush mounted 3 pin all as specified.
S&F in replacement of Switch socket combination 5/6 Amps flush mounted 3 pin multi purpose all as specified.(Make:Anchor/Vinay)
S&F in replacement of switch socket combination 5/15 Amps flush mounted 3/5 pin multi purpose all as specified.(Make:Anchor/Vinay)
S&F in replacement of switch piano flush type 5 Amps SP one way all as specified. (Make:-Anchor/Vinay)
S&F in replacement bell push, flush type 5 Amps all as specified and directed.(Make:-Anchor / Vinay)
S&F in replacement of fan regulator electronic step type suitable for 1200/1400 mm sweep fan (Make:Anchor/Vinay)
S&F in replacement for ceiling rose, 2 to 3 terminals /PVC/Polycarbonate, isolated body.
S&F in replacement junction box one/two/three/four way suitable as per site requirement all as specified and directed
S&F in replacement of door bell AC 230 volts single phase ding dong type all as specified and directed. Make:Anchor/Vinay
S&F in replacement of switch socket combination with box 5/6 Amps flush mounted 5 pin multi purpose all as specified.
S&F in replacement of switch socket combination with box 5/15 Amps flush mounted 3/5 pin multi purpose all as specified.
S&F in replacement of 1 module Blanking plates complete all as specifed and directed by Engr-In-Charge. Make: Vinay/Anchor Roma
Taking down carefully copper/aluminium point wiring (light/fan/socket) including all accessories wire, casing caping/conduit, screws etc and making good the disturbed surfaces all as directed
M&L point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unsheathed cable and including surface, PVC conduit/PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLS cable size 1.0 sq mm copper conductor as earth wire to common earth dolly including PVC box suitable for switches, sockets, fan regulator etc for following :- One light/Fan point controlled by one way switch 6 Amps 240 volts
Ditto all as per item No 22 above but One 3 pin 6 Amps socket out let point on independent board.
Ditto all as per item no 22 above but One 3 pin 6 Amps socket out let point on same board.
Ditto all as per item no 22 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size.
M&L for point wiring with 2.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable and including surface, PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FR cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box suitable for 15 Amps socket and switch outlet power point independent circuit
S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified Note: MCCBs and MCBs will be measured and paid seperately under respective Sch A item in the schedule
S&F in replacement MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced.
S&F in replacement MCB DB 08 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site.
S&F in replacement MCB DB 04 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site.
S&F in replacement MCB DB 04 way SPN (Single door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site.
S&F in replacement MCB DB 02 way SPN (single door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site.
S&F in replacement MCCB with rating of 100 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu). MCCB should be with suitable spreaders and phase barriers for each terminals complete all as speicified.
S&F in replacement of C Curve MCB SP 6-32 Amps working on 240 volts,50 Hz 10 KA complete all as specified and directed.
S&F in replacement of C Curve MCB DP 6-32 Amps working on 240 volts, 50 HZ,10 KA complete all as specified and directed.
S&F in replacement of C Curve MCB SPN 40-63 Amps working on 240 volts, 50 HZ,10 KA complete all as specified and directed.
S&F in replacement MCB TPN 40- 63 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing.
Taking down carefully sub main wiring of any type and size and making good disturbed surfaces complete all as directed.
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including casing caping/Conduit medium grade not less than 25 mm complete with accessories and copper cable 6 sqmm continuous earth wire complete all as specified and directed (Two runs of 6 Sqmm cable with 01run of 06 Sqm m earth wire along with casing caping shall be measured as one RM)
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25mm complete with accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed (Two runs of 04 Sqmm cable with 01run of 04 Sqmm earth wire along with casing caping shall be measured as one RM)
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including casing caping medium grade not less than 25 mm complete with conduit accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and directed (Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with casing caping shall be measured as one RM)
M&L for secruing loose wiring and repair to point wiring with necessary PVC Conduit/ PVC casing caping double lock type ISI marked of size not less than 25mm inclusive all accessories complete as specified and directed.
S&F in replacement of GI pipe bracket of 25 mm dia 1.2 mtr long bend to shape for street light fitting made out of 25 mm dia GI light grade pipe fixed on pole using suitable FI clamp including necessary new nut, bolt and washer complete all as specified and directed.
S&F in replacement sleek body LED building security light fiitting of wattage not less than 20 W,IP-65 protection made up of die cast aluminium housing with lens covered high power LED as lighting source complete all as specified and directed Make Luker Cat part no. LSTE20 or equivalent in Philips
S&F Stationary type electric water heater closed/vented type , inner body made out of copper of capacity 25 Litres suitable for 230 volts, single phase AC 50 HZ Supply ISI marked to IS;2082 (Part /1993) (reffirmed 2004) with latest amendments and having BEE Star (5 Star Rating) complete with all accessories and fittings as per requirement and depositing old water heater of any type and capacity to MES Store yard complete all as specified and directed by Engr-in-charge. Make: Havells/Racold/V-Guard
Taking down ceiling fan/exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as directed. Note : 1.Cost of spares such as capacitors, bearings etc will be measured and paid for separately under respective Item of sch A as Supply only. Note No (iii) to (vi) below Item No 1 of this schedule are equally applicable to this item too.
Supply only capacitor of 2.5 mfd for ceiling fan/exhaust fan. Make:Tibcon/Epcos
Supply only capacitor of 4 mfd for air circulator/exhaust fan. Make:Tibcon/Epcos
Supply only of bearing No.6201/6202/6203 or any other No. matching to the existing size and suitable for ceiling fan/exhaust fan/wall mounted fan.Make:SKF
Disconnecting electric connection and taking down carefully fan of any type and size/sweep as described below, removing the burnt winding of fan motor rewinding with super enarneled copper winding wire of suitable gauge or of matching size to the exisiting wires including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and reflxing to original position complete all as directed Celling fan of size 1200 sweep.
Ditto all as per item no 50 above but Exhaust fan of 300 mm sweep.
M&L for painting the ceiling fan of any sweep with two coats of synthentic enamel paint by rubbing/removing the old paint carefully without any damage to the fan or fan blades complete all as specified.
Ditto all as per item No 52 above but exhaust fan of size 12" (300 mm)sweep
Dismantling and removing rusted louvers suitable for any sweep exhaust fan supply and fix MS louvers duly painted gray coloured suitable for any sweep heavy duty exhaust fan alongwith four number mounting bracket with bolts, nuts washers etc complete all as directed.
S&F in replacment aluminum fan blades sutable for heavy duty exhaust fan of any sweep as per the sample given by the site-in-charge
S&F fan hook of suitable size complete all as specified and directed.
S&F Heavy-Duty Pin anchor fastener of suitable size for fixing fan hook/Geyser complete all as specifed and directed
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc complete all as specified
S&F in replacement PVC insulated round cable 2 core stranded copper conductor 1 sqmm all as specified and directed
S&F in replacement 1x10 watt,230V surface and wall mounted LED batten, including connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified .
S&F in replacement of 18/20watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose complete all as specified and directed
S&F in replacement of 18/20 watt of LED retrofit tube light with high efficiency suited for installation in existing T8 tube light with G13 lamp holders complete all as specified and directed.
S&F in replacement 1x18/20W,230V surface and wall mounted batten suitable for installing LED Tube including connecting up with twin core twisted flexible copper condctor cable from ceiling rose complete all as specified .
S&F in replacement recess mounted 2' x 2' LED Panel lights 40 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver. Make: Luker Cat Part: LPS40 or equivalent in Philips/Havells
S&F in replacement surface mounted LED Panel lights size of 600mm x 600MM x 35mm 40 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver. Make:Luker cat part no LNPSRS40 or equivalent in Philips/Havells
S&F in replacement of 150 watt integral SMD LED Highbay luminaire with aluminium reflector light fitting incl with inbuilt electronic drivers, necessary hanging arrangements as per site requirement all as specified and directed. Make Luker Cat part No. LOHY150 or equivalent in Havells/Philips Note: 1. Ladders /Cranes shall be used and will be provided by contractor for dismantling /fixing of light fittings at roof of AFTT hanger/ETT and cost for the same is deemed to be included.
S&F honor board LED (warm white) fitting of 1x12 Watt individual LED lenses, chorme coloured. Make: Luker Cat part No. LMCL12 or equivalent in Havells/Philips
M&L for replacing the down rod of ceiling fans with 5 feet GI ceiling fan hanging down rod with necessary clamp accessories all as directed.
S&F ceiling fan of sweep 1200mm,240volts, of not less than 5 star BEE rating milk white coloured connecting up with twin core 1.0 Sqmm cable from ceiling rose including required length of down rod as per the site requirement complete all as specified.
Disconnecting and taking down existing userviceable geyser of 25 ltrs capacity, taking it to civil workshop for repairing. Opening the geyser and dismanting all parts and taking out inner tank/container, removing dents making to shape including welding / brazing the leakage portion, filling the portion between inner tank and out casing of geyser with new glass wool heat insulating material . Reassembling and painting the outer casing of geyser with two coats of superior quality synthetic enameled paint and re fixing to original place complete all as directed
Supply and fix in replacement NRV valve of size 15mm dia of Brass complete all as specified and directed.
M&L in replacement thermostat 0-85ºC suitable for geyser of 25 ltrs capacity.
M&L in replacement heating element of capacity 2 KW of any type and shape suitable for 25 ltrs capacity geysers as per sample provided
M&L in replacement heating element of capacity 3 KW,ISI marked of any type and shape suitable for solar water heater system as per sample provided
S&F in replacement heating element of capacity 3 KW of any type and shape suitable for Existing 100 ltrs capacity geysers as per sample provided by Engr-in-Charge
M&L in replacement flow unit (inner pipe assembly) suitable for geyser of 25 ltrs capacity vertical type including rubber ring/gasket.
Supply and fix in replacement metallic flexible hot water connection 600 mm long including necessary washers suitable for geysers of 25 ltr capacity complete all as specified and directed.
Supply & fix neon lamp indicator square/round type after taking out old including taking down old one.
Supply & Fix in replacement PVC insulated round cable 3 core stranded copper conductor 2.5 sqmm complete all as specified and directed.
S&F in replacement sheet metal enclosures Single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB single pole 20 Amps, 240 volts complete with all accessories etc complete all as directed
S&F in replacement plug top 3 pin, 15/16 amps, 230 volts, ISI marked heavy duty for geyser connection cord.
S&F in replacement metal clad plug top 3 pin,20 Amps, 230 volts, ISI marked heavy duty for geyser connection cord.
S&F Electronic driver suitable for 15/20/25 watts LED building security light fittings as per existing make complete all as specified and directed.
S&F Surge protection device suitable for 15/20/25 watt LED building security lights/other LED fixtures as per the existing make all as specified and directed.
S& F PVC unbreakable surface boxes of size 4x4. Make - Press Fit/Anchor
S& F PVC unbreakable surface boxes of size 6x6. Make - Press Fit/Anchor
S& F PVC unbreakable surface boxes of size 4x7. Make - Press Fit/Anchor
S& F PVC unbreakable surface boxes of size 6x8. Make - Press Fit/Anchor
S& F PVC unbreakable surface boxes of size 8x10. Make - Press Fit/Anchor
S&F in replacement for white cover plate with frame 3 module. Make: As per the sample given
S&F in replacement for white cover plate with frame 6 module.Make:As per the sample given
S&F in replacement for white cover plate with frame 8 module.Make:As per the sample given
S&F in replacement for white cover plate with frame 12 module.Make:As per the sample given
S& F in replacement PVC unbreakable surface boxes suitable for modular switches 3 module.
S& F in replacement PVC unbreakable surface boxes suitable for modular switches 6 module.
S& F in replacement PVC unbreakable surface boxes suitable for modular switches 8 module.
S& F in replacement PVC unbreakable surface boxes suitable for modular switches 12 module.
Supplying and fixing 1100 volts grade heavy duty cable 4 Sqmm PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular
S&F in replacement of high speed wall mounted fan of sweep 400 mm,,Full copper motor,auto thermal overload protection,compact style and powder coated gurads & pull cord switch for speed regulation and oscillation control including connectng up the power cord to the socket and necessary fixing accessories all as specified and directed. (Note: Old wall fan should be deposited in MES store yard) Make:Crompton or equivalent in Havells/Usha
S&F in replacement of Plastic ventilation fan of 200 mm sweep inclduing replacing the plywood as per the site requirement. (Note: Old Exhuast fan should be deposited in MES store yard)
S&F in replacement of metal body ventilation fan of 225/230 mm sweep inclduing replacing the plywood as per the site requirement. (Note: Old Exhuast fan should be deposited in MES store yard)
S&F energy saving, surface mounted, decorative hexagon 10 W bulk head LED luminaire comprising of high brightness LEDs., IP66 protection including all connection all as specified and directed by Engr-in-charge. Make: Havells Cat Part no. HEXAFT10WLED857SSYMBOPC or equivalent in Philips/Jaquar
S&F in replacement Decorative, wall mounting fixture, in durable plastic body & designer mesh in gold finish suitable for upto 14 W Retrofitt LED (B-22 base) including 01x10 W LED bulb and connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified. Make:Havells Cat part no LHFOECE1TZ1B014 or equivalent in Luker/Philips
S&F in replacement 40 W suspended LED Light with high efficiency providing soft-light and glare free symmetrical illumination including suspension kit including connecting up with twin core twisted flexible copper cable from ceiling rose to fitting complete all as specified and directed. Make: Havells Cat part No. CONSTA1144LP40WLED840SPCWH or equivalent in Luker/Philips
Fixing only 25 L Geyser and connecting up including with suitable fastner as per ground requirement complete all as specified and directed. (Note:Geyser will be issued under Sch 'B' store free for fixing only)
Fixing only ceiling fan of 1200 mm sweep and connecting up including provision of twin core flexible copper cable from ceiling rose or connector to fan all as specified. (Note:Ceiling fan will be issued under Sch 'B' store free for fixing only)
Fixing only Exhaust fan of any sweep and connecting up including provision of twin core flexible copper cable from ceiling rose or connector to fan all as specified. (Note:Exhaust fan will be issued under Sch 'B' store free for fixing only)
Supply & fix in replacement environment friendly, energy efficient, aesthetically designed, surface ornamented with rings, moulded body, ceiling light LED fixture with diffuser to give glare free light 15 watt LED. Make -Luker Cat Pt No LIPSRS15 or equivalent in Philips or Havells
S&F electrical meter box compartmentalized design suitable for 4 x energy meter and 4 x Two way SPN DB, outdoor wall mounted type, weather proof fabricated out of not less than 2.0 mm thick CRCA sheet, powder coated in siemens grey colour, double door. The enclosure shall be front openable with locking arrangement and provided with 5 mm thick bakelite sheet for mounting the energy meters and MCB DB. The enclosure shall be provided with suitable size PVC cable glands for incoming and outgoing cables/wires. The overall size of the meter box should be as per site requirement complete with all accessories prewired twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.( For NCO Qtrs) (Note: quoted rate shall deemed to including for disconnecting existing circuits from DB's and energy meter and same has been refixed in new meter box)
S&F electrical meter box compartmentalized design suitable for 1x energy meter and 1 x Four way SPN DB, outdoor wall mounted type, weather proof fabricated out of not less than 2.0 mm thick CRCA sheet, powder coated in siemens grey colour, double door. The enclosure shall be front openable with locking arrangement and provided with 5 mm thick bakelite sheet for mounting the energy meters and MCB DB. The enclosure shall be provided with suitable size PVC cable glands for incoming and outgoing cables/wires. The overall size of the meter box should be as per site requirement complete with all accessories prewired twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.( For JCO Qtrs) (Note: quoted rate shall deemed to including for disconnecting existing circuits from DB's and energy meter and same has been refixed in new meter box)
SONU ENTERPRISES
G V HAGAWANE
Tejas Enterprises
M/S SHREE CONSTRUCTIONS
Sparkh Electricals & Works
KESARI AND SONS
KSP ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .