Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹67.0 L+₹3.1 L (4.91%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹67.5 L+₹3.7 L (5.83%)Rejected-Finance NO 18 8 254 26 RAKSHAPURAM SAIDABAD POST HYDERABAD 500 005 | HYDERABAD | HYDERABAD | TELANGANA | 500005 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹68.2 L+₹4.4 L (6.82%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹68.4 L+₹4.6 L (7.15%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
2 Mar 2021, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
ADDITION / ALTERATION/ REFURBISHMENT OF ELECTRICAL/ CIVIL WORKS FOR AUTOCLAVE FACILITY (BLDG NO.29) AT ASL KANCHANBAGH, HYDERABAD
2021_MES_418481_1
GE I KBAGH TOKEN 80 OF 2020 2021
Open Tender
Civil Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE I R and D Kanchanbagh
₹1.4 L
Yes
20 Mar 2021
3 Feb 2021
4 Mar 2021
3 Feb 2021
2 Mar 2021
16 Feb 2021
3 Feb 2021 - 10 Feb 2021
Amount
Demolition of brick/stone masonry built in cement mortar including all quins arches, pillars etc complete all as directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness below or above ground level, removal fo rubbish and debris and depositing in low lying areas complete all as directed.
Dismantling of Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as directed.
Taking down chowkhats or frames not exc 1.50 sqm (without taking shutters from the frame) complete all as directed.
Taking down chowkhats or frames exc 1.5 sqm but not exc 4.00 sqm (without takng off shutters from the frame) complete all as directed.
Dismantling of framed timber scantlings 40 sq. cm and over in section, in any position complete all as directed.
Dismantling boarding, any description, fixed any position with nails complete all as directed.
Taking down cement plaster on brick/stone masonry walls, ceilings etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing removing serviceable tiles to store and rubbish off the premises complete all as directed by Engr-in-charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as directed.
Taking down existing roof treatment of any description, any position with bituminous felt including plaster/loose concrete and removing rubbish to a distance exceeding 500m but not exceeding 1000m and roughening the surfaces of old concrete by picking, scraping, cleaning and washing down with water to remove all dust etc complete specified and directed.
M&L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in padding concrete, coving of vertical junctions, coping of vertical junctions, coping and and plateform for OH water tanks etc on roof top, complete all as directed.
M&L for brushing neat cement slurry with 3 Kg of cement per Sqm over the RCC slab and sides complete all as directed.
M&L for rendering 10mm in CM 1:3 over concrete surfaces on RCC roof slab and parapets mixed with WPC @ 3% by weight of cement shall be carried out complete all as specified and directed. Note : WPC will be measured under separate item of this schedule.
M&L water proofing treatment with polymeric standard membrane of weight not less than 3kg per sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150gms/sqm) laid over primed surface by forced application complete. Shall be fused uniformly by LPG torch flame on horizontal/vertical/slope surface on roof complete all as specified and directed by Engr-in-Charge. Water proof treatment consist of as under: - (i) Applying one coat of bitumous primer conforming to IS 3384 @ 0.3 ltrs per sqm (ii) Laying APP based memberane as specified thickness and weight. (iii) Appplying one coat of bitumen grade 85/25 @1.20Kg per sqm. (iv) Applying a coat of bituminous aluminium paint.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick or any colour having tensile strenght of 5510 Mpa as in roof coverings/ cladding to wall, fixed with self tapping screws as specified.
S&F of 600mm dia stainless Steel Turbo ventiletors with Polycarbonate base fixed on roof with self tapping screws ete complete all as directed.
M&L Preparation of old painted surfaces of steel or iron surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M & L for Fly Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, rendering is to be finished even and smooth without using extra cement complete all as directed.
Rendering 15mm thick on brick or concrete surfaes in CM 1:4 using integral waterproofing compound finished even and smooth without using extra cement complete all as specified and directed. Note:- Intergal waterproofing compound shall be measured and paid separately.
Supply only integral waterproofing compound.
S&F IInd class hard wood plain, solid, straight chowkats and frams wrought, framed rebated on solid, rounded or chamfered put together with glue pinned at joints complete all as directed.
S&F 2nd Class HW rail and style 35mm Thickness Factory made shutters Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as directed.
S& F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing
S&F Factory made solid panel pace door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S&F mild steel butt hinges, medium weight cold rolled 100mm size complete.
S&F 200 mm aluminium anodized, barrel tower bolts of extruded section. Make : CROWN/JYOTHI/PRESTIGE
S&F 150 mm aluminium anodized, barrel tower bolts of extruded section. Make : CROWN/JYOTHI/PRESTIGE
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodized complete.
S&F 300mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy complete.
S&F floor door stopper 150 mm of aluminium alloy body and tongue anodized with hard drawn steel spring fixed complete all as directed.
S&F mild steel work as Bands, straps, hold fasts and similar small articles conforming to Fe410-0 or Fe 310-0
S&f of Anodised aluminium snap grid frame work 'Size of grid 605x605mm for false ceiling all as specified.
S&F Perforated particle board/tiles for insulation and acoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid including two coats of synthetic enamel paint over pink primer complete all as directed.
M&L 100mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate)as in floor including finished floor surface even and smooth with using extra cement complete all as directed.
M & L for 75mm thick plain cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in floor, Plinth Protection,Including finishing surface even and smooth with out using extra cement, complete all as directed.
Treating cement concrete or granolithic concrete surfaces with three dressings or sodium silicate solution complete all as directed.
S & F of 48 mm width Glass dividing strips, 3mm thick and and inserted in position to conform to design complete all as directed.
S&F vitrified tiles 10mm thick (Square/rectangular) polished area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm in floors etc laid over 15mm thick screed bed in CM 1:6 and pointed in white cement or coloured cement to match with colour of tiles complete all as specified and directed.
All as per item No.40 above but as in skirting /Dado, set and jointed in neat cement slurry and pointed in coloured cement to match with tiles laid on and including 10 mm thick rendering in CM 1:4 as backing layer complete all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc over 15mm thick screed bed in CM 1:6, jointed and pointed in white or coloured cement to match with the colour of tiles complete all as directed.
M&L for glazed multi coloured glazed ceramic tiles incl border of size 350x250x7mm/450x 350 x 7mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in CM 1:3 on fair faces of brick/ concrete surfaces complete all as specified and directed.
M&L for preparation of new plaster surface of existing treatment and applying two coats of distemper oil emulsion over a coat of alkali resistant priming paint on surfaces of walls over a two coats of wallputty (1.5mm each) to make surfaces smooth complete all as directed.
M&L for preparation of new or previously untreated surfaces of wood or wooden based sufaces of any description, not otherwise described, over 10 cm width or girth and applying Two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Supplied and fixing in repairs of Steel rolling shutters of 1.25 mm Thickness of laths with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; gear operated type with chain wheel and hand chain complete all as directed.
S&F ball bearing for rolling shutter complete all as directed.
M&L for complete removal of existing treatment of steel sufaces of any description, not otherwise described, over 10 cm width or girth and applying Two coat of Aluminium paint over a coat of Aluminium over a coat of red oxide primer complete all as specified and as directed.
S/F of 5.5mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as directed.
Removing building materials etc., (other than spoil payable under items 03028 to 03031 in Section 3--Earthwork) to a distance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination (Up to 1.0 km total distance) complete all as directed.
S & F in repairs vitreous china wash hand basin, white, flat back of size 550x400 mm excluding taps, waste, chain and plug and procelain stopper but including bracket and waste fittings, brass, CP 32 mm dia complete all as directed.
S & F in repairs vitreous china wash down water closet pan (pedestal pattern) (EWC), white including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device and fixing bolts complete all as directed.
S & F in repairs vitreous china urinal, half stall type, white, with urinal spreader of chromium type fixing with 15mm dia pipe, bracket, including necessary connection to flush pipe and waste pipe complete all as directed.
S & F in repairs 10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as directed.
S&F in repairs towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleats (Minimum weight 190gms) complete all as directed.
S & F repairs 15 mm dia Bib taps, cast copper alloy chromium plated Fancey type with capston head handle, screwed down, screwed for iron pipeplete all as directed.
S & F in repairs 15 mm dia stop valves, Fancey type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as directed.
S & F in repais 15 mm dia Fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shank and fly nuts, screwed for iron pipe complete all as directed.
S & F PVC connections 15mm size with PTMT nuts of length 450mm long.all as specified and as directed
S&F 32mm dia High density polyethylene pipes (HPDE) of pressure rating 6Kgf/cm2 fixed complete to walls, ceiling or in floors etc., complete all as directed.
S&F in repiars steel tubing and connections 15mm dia GI steel tubes, medium grade with all fitting and fixed complete to walls and ceiling or laid in floors complete all as directed.
S&F in repiars steel tubing and connections 20mm dia GI steel tubes, medium grade with all fitting and fixed complete to walls and ceiling or laid in floors all as specified and as directed.
S&F in repiars steel tubing and connections 25mm dia GI steel tubes, medium grade with all fitting and fixed complete to walls and ceiling or laid in floors all as specified and as directed.
S&F in repiars ball brass valves of 25mm dia, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule complete.
S&F 1000 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
S&F 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as directed.
S&F 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as directed.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as directed.
S&F Grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as directed.
S&F Grating square 150 mm size of PTMT (Minimum weight 100 gms) complete all as directed.
S&F in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as directed.
S&F in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as directed.
S&F 110mm dia PVC bends/shoes suitable to PVC rain water pipe including necessary clamps etc fixed on wall all as specified and directed.
S&F 75mm dia PVC bends/shoes suitable to PVC rain water pipe including necessary clamps etc fixed on wall all as specified and directed.
S&F 110mm bore PVC (SWR) vent cowl complete all as directed.
S&F factory made UPVC white colour sliding window three track made of extruded profile with wall thickness of 2.3mm (+) -0.2mm area exc 2.00 sqm each. Window profile with hollow sectionwith multy chamber. Frame (88mmx 52mm). Sliding sash (42mm x 67mm). Sliding mesh sash (42mm x57mm) sliding inter lock one vertical length in each shutters) 45.5mmx28mm). glazing bead (24,5mmx16mm). will be mitered cut and fusion welded at all corners. including railing of holes for fixing hardware and drainage of water etc.making arrangement for fixing of hardware,EPDM gasket, 1.2+ -0.2mm thick galvanized steel frame (30mm x 18mm) 2 n0s, sliding sash (30mmx 18mm). Sliding mesh sash (26mmx 10mm) profile to be inserted in required profile.Frame will be fixed to the wall with 8mmx 100mm long fasteners.Hardware Touch lock of Zinc alloyed (white powder coated). Steel roller system. Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm including provision of float glass of 4.8mm and required accessories. Note :- The unit rate quoted by the contractor include cost of glass wire mesh all other connected accessories. Net opening will be measured for payment purpose.
All as per item No.76 above but area n exc 2.00 sqm each complete all as directed.
S&F for rectangular aluminium hollow section of size 101.6 x 44 x 2mm thick as in partition (including fixing with nut and bolt in floor and wall by drilling holes), powder coated of approved colour for both vertical and horizontal member including 5.5mm thick glass, 12mm thick particle board prelaminated on both side, aluminium legs, aluminium glazing channel, rubber beading as required complete all as directed.
Same all as per item No 78 above but as in door, powder coated, approved colour, including 5.5mm thick glass, 12mm thick particle board prelaminated on both side, rubber beading, aluminium glazing channel, two Nos handles, three Nos extruded aluminum hinges 100 mm long, two Nos 200 mm aluminium anodized, barrel tower bolts of extruded section, one floor door stopper 150 mm of aluminium alloy body, 100mm size brass mortice lock, 4 levers with two keys and floor door spring as required for door complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness below or above ground level, removal of rubbish and debris and depositing in low lying areas complete all as directed.
M/L 100 mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) including finishing surfaces of concrete topping even and rough to receive the topping layer, including necessary form work, Complete all as specified and directed.
M/L PCC (1:2:4) Type B-1 using 20mm aggrigate as in coping, kerb wall including necessary form work weathering,slightly rounded or chamfered angles and throating, complete all as specified and directed.
M/L for Sand cushioning under floors or in foundation including watering and consolidation complete all as directed.
S/F Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade laid with grey cement and no pigment complete all as directed.
Taking down old unserviceable point wiring (Light,Fan,bell,Socket or power) complete including fixture and fittings such as switches, ceiling roses,regulators, sockets, light fittings etc and making good to the disturbed surfaces of walls,ceilings and floor match the existing shade complete all as specified and directed.
Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated unsheathed multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit not less than 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, surface/ concealed type on any type walls, roofs, floors etc by means of saddles and clamps etc including shrink type MS terminal boxes fabricated out of 1.6mm thick MS sheet ISI marked suitable for modular switches & sockets of necessary modules as per site requirement including providing of 1.5 Sqmm PVC insulated FRLS multistranded unsheathed copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified for the following:-
One light/ fan point controlled by one, one way switch/bell push
All as per item No. 86 above but for 5 Amps socket on independent board
All as per item No. 86 above but for 5 Amps socket on same board
All as per item No. 86 above but wiring with 2.5 Sqmm for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly.
S&F white cover plate with frame 8 module.
S&F white cover plate with frame 4 module.
S&F white cover plate with frame 3 module.
Supply and Fixing Modular switch single pole, one way 6 Amps one module all as specified and directed.
Supply and Fixing Modular switch single pole, one way 16 Amps one module all as specified and directed.
Supply and Fixing Modular socket 6 Amps multipurpose 2 in 1- 2/3 pin combined 2 module complete all as specified and directed.
Supply and Fixing Modular socket 6/16 Amps multipurpose 2 in 1 -2/3 combined 2 module complete all as specified and directed.
Supply and Fixing ceiling rose three terminals Poly carbonated isolated body complete all as specified and directed. Make for item Nos.88 to 95:- Legrand/L&T/Schneider/Crabtree
S&F recess mounting 36W LED edge-lit luminaire suitable for armstrong/grid ceiling complete for low ceiling application made with CRCA sheet metal with premium white high translucent frosted wide diffuser of size 2'x2', luminaire efficacy >120lm/w, color temp. 5700 K confirming IS 15885 part 2 provided with surge protector electronic driver complete with all accessories three core felxible cable all as specified. Make: Havells Cat Part: PLANO2X2PLR36WLED857S or equivalent in Wipro/Philips
Supply and fix High bay 80W LED light fittings IP65 protected luminaire robust open type vertical Highbay/Mediumbay LED IP65 luminaire with high power SMD LEDs as light source of luminous efficiency not less than 120 lm/w, color temp 5700Kinclduing fixing to the ceiling/ trusses using necessary fastner/hook for hanging the lights and connecting with three core 2.5Sqmm round copper cable from ceiling rose to the connector of the fitting all as specified and directed. Make : Havells Cat No. FLARENEOCA80WLED757PSYMLTG or equivalent of Wipro/Philips/Crompton
S&F LED security light fiitting 20W,IP-66 protection, 5700K color temp, made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC lens having complete fixing with GI bracket made out of 40mm bore GI pipe light grade 1.5Mtr long bend to shape and fixed to pole/wall with necessary MS clamp accessories complete all as specified . Make: Havells Cat Part: ENDURA PEARLSL20WLED757SASYTOPCMP or equvalnet in Wipro/ Philips
S&F 1x22W,230V surface and wall mounted LED batten,with extended aluminium housing along with industrial heavy duty driver having THD <10% lumen out put not less than 100 lm/w including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified. Make:- Havells Cat part No. ENDURALINEARNEOBS22WLED865SPCWH or equivalent in Wipro/ Philips
Material and Labour for sub main wiring with 4 runs of 6 Sqmm single core PVC FRLS insulated unsheathed cable 1100 Volts grade multistranded with copper conductor drawing through rigid PVC conduit medium grade not less than of 25 mm dia including conduit and conduit accessories such as bends,tees,junction boxes concealed/surface type on walls, roof, floors etc including 2 run of 6 Sqmm PVC insulated FRLS copper conductor cable as earth continuity wire including taking down unserviceable sub main wiring and conduit all as specified and directed. Note: 4 Runs of 6 sqmm cable and 2 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit.
Material and Labour for sub main wiring with 2 runs of 4 Sqmm single core PVC FRLS insulated unsheathed cable 1100 Volts grade multistranded with copper conductor drawing through rigid PVC conduit medium grade of 25 mm dia including conduit and conduit accessories such as bends,tees,junction boxes concealed/surface type on walls, roof, floors etc including 1 run of 4 Sqmm PVC insulated FRLS copper conductor cable as earth continuity wire including taking down unserviceable sub main wiring and conduit all as specified and directed. Note: 2 Runs of 4 sqmm cable and 1 run of 4 sqmm cable and 1 run of PVC conduit shall measured as one unit.
Supply and Fixing Modular step type fan regulator 230 Volts, 120 watt 2 module complete all as specified and directed.
Supply and fixing in repairs factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB ) MCCB TPN as In comer, with metal door IP-43 protection, IK-09 as per IES-61439-3 fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and 200Amps copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified Make/Model of VTPN DB : Legrand Cat part: 5077 45 or equivalent in L&T / Siemes Note: MCBs will be measured and paid seperately under respective Sch A item in the schedule
Supply and fixing in repairs factory made epoxy powder coated Distribution Board TP & N 8 way double door ( MCB DB ) MCB TPN as In comer, with metal door (IP-30 protection, IK-08) as per IES-61439-3 fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified (Make/Model of TPN DB : Legrand Cat part: 5077 70 or equivalent in L&T /Siemens) Note:MCBs will be measured and paid seperately under respective Sch A item in the schedule
S&F in repairs MCCB with rating of 100 Amps,415Volts 4pole with 16kA breaking capacity,thermal magnetic adjustable of overload & short circuit release confirming IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu).MCCB should be with suitable spreaders and phase barriers for each terminals. Make: Legrand Cat part: 4200 15 or equivalent in L&T/Siemens
Supply and fix in repairs C Curve MCB TPN 63 Amps working on 415 volts, 50 HZ,10 KA all as specified and directed. Make: Legrand/L&T/Siemens
Supply and fix in repairs C Curve MCB SP 6-32 Amps working on 240 volts,50 Hz 10 KA complete all as specified and directed. Make: Legrand/L&T/Siemens
Supply and Fix in repairs single pole and neutral metal clad enclosure with a 2 pin and earth plug & socket with 20 Amps MCB SP complete all as specified and directed.
Taking down ceiling/exhaust/wall mounted/pedestal fans/ air circulators of any sweep of any make with down rods, blades canopy etc by disconnecting the electric connections, replacing worn out bearings, capacitor, bushes and including replacement of minor parts like split pins, nuts, screws, washers etc and other worn out spare parts as required, greasing, reassembling, painting and reconnecting with 3 core new flexible cord from ceiling rose to fan complete all as specified and directed.
Disconnecting and taking down indoor and outdoor unit of split AC of any make and capacity upto 2 Ton with stabiliser from the existing position, servicing, gas top up minor repair and refixing with nitrile rubber insulatiing pipe for suction discharge pipe the same after renovation of the building
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m deep below normal ground level with top edge of earth plate, not less than 1.5 m below normal ground level connected to galvanised iron earth lead of size 4.0 mm dia by means of bolts, nuts/check nuts and washers etc of galvanised iron, protected by galvanised iron pipe light grade 15 mm dia upto a length of 7.5 m away from earth electrode and connected to main switch/control board including necessary excavation earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40 mm thick RCC cover slab 1:2:4 type B1 with 6 mm dia TMT Bars at 140 mm cc both ways, watering pipe 20 mm dia light grade GI, funnel, wire mesh, lugs, charcoal and salt etc complete all as shown in Electrical plate No. 3 SSR Part I and testing complete including removing unserviceable items all as specified and directed.
S&F in repairs GI earth wire of 4 mm dia fixed on walls/floor as earth continuity conductor connected to DBs/ panels etc.
Design, supply, erect, testing & commissioing of motorization including motor & mechanisation equipment for existing mechanical rolling shutter (any size upto 600 Kg lifting capacity) in one single unit with 600 Kg lifting capacity by replacing the rolling spring assembly with new cylindrical type rolling assembly and chain crant in absence of power complete with ball bearing and springs which enable minimum cost of maintenance with single phase push button starter with all connection, copper wiring complete, limit switches, control wiring with copper conductor including necessary dismantling / refixing of rolling shutter, addition / alteration civil works etc., complete all as specified and directed.
Disconnecting the electric supply and Dismantling & Removing of old unserviceable LT Panels complete all as directed.
Supply , install test & commission of LT Panel in door, Cubicle type, free standing floor/plint mounting confirming IEC 61439 - 1 & 2 factory fabricated out of CRCA Sheet of 2.0 mm thick dust, vermin & weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing aluminium bus bar of capacity 600 Amps rating for 415 V 50 Hz 3 Phase 4 wire system, cotated with RAL7032 after 7 tank process with thickness of min 80 mircons including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable along with ferouts. The panel should be mounted on 'C' channel base of required size duly coated with anti corrosive paint. the circuit distribution lines to be marked over the panel using poly venyl reflective stickering (Where necessary) complete with following:-.
(a) On Load change over switch 400Amps 4pole confirming IS : 13947 -01No. (b) MCCB 400 Amps 4 pole 35 KA with microprocessor release, 36 KA Ics=100% of Icu with electronic earth leakage module (minimum 70% to 100%) -01 (c) MCCB 200 A, 4P, 25KA thermal magnetic release and adjustable over load & short circuit settings - 01 No (OG) (d) MCCB 100 A, 4P, 16KAthermal magnetic release and adjustable over load & short circuit settings - 01 Nos (OG) (e) MCCB 63 A, 4P, 16KA thermal magnetic release and adjustable over load & short circuit settings - 01 Nos (OG) (f) MCB 32 A, TPN, 10KA 'C' Curve - 08 Nos (OG)
S&F APFC panel of capacity 150 KVAR confirming IEC 61439 - 1 & 2 with 10% fixed capaicty & 90% of variable capacity all as per IEC standards including the power factor control module with internal wiring, panel made with 2mm thick CRCA sheet metal enclosure indoor type, dust & vermin proof free standing mounted on 'C' channel base completa all as specified and directed.
Taking down old unseviceable UG cable of any size/capacity including making good to the disturbed area complete all as specified and directed.
Supply, Laying, Test & Commissioning LT UG cable of size 400 sqmm; 3.5 core XLPE insulated, armoured, multistranded heavy duty, aluminium conductor electric cable of 1100 volts grade laid in ground, through trench/pipes including caution tape, connecting with aluminium lugs, necessary cable glands etc and including removing old unserviceable cable all as specified and directed.
All as per Item No. 119 above but of size 3.5 core 50 sqmm
All as per Item No. 119 above but of size 3.5 core 120 sqmm
Taking down old unseviceable sub main wiring of any size/capacity including making good to the disturbed area complete all as specified and directed.
Material and Labour for sub main wiring with 2 runs of 1.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit 20 mm dia including conduit accessories concealed/surface type on walls, roof, floors etc including one run of 1.5 Sqmm PVC copper conductor as earth continuity wire including taking down unserviceable sub main wiring including conduit all as specified and directed. Make of Gang Boxes: GM/Havells/Legrand Note : 2 Runs of 1.5 sqmm cable 1 run of 1.5 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment.
Supply & Fix Triple pole and earth enclosure with a three pin and earth plug metal clad socket 415 Volts, AC, complete with one triple pole MCB 32Amps including taking down unserviceable triple pole and earth enclouser and making good to the disturbed surfaces of wall as directed.
Supply & Fix Triple pole and earth enclosure with a three pin and earth plug metal clad socket 415 Volts, AC, complete with one triple pole MCB 63Amps including taking down unserviceable triple pole and earth enclouser and making good to the disturbed surfaces of wall as directed.
Excavation in trenches not exc.1.5 Mtr in width and not exceeding 1.5 Mtr in depth for laying of cables and getting out in hard/dense soil etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick using soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point all as specified.
Supply and filling Dry river sand for cushioning to cables in trenches including spreading, levelling complete all as specified and directed. Note:- Only punned thickness will be considered for measurement purpose.
Supply and lay well burnt brick class 'B' of locally available as protection of cable in trenches all as specified and directed.
Supply and Fix GI tubing 100 mm dia light grade for protection of earth conductor on wall/burried in earth and all as specified and directed.
S&F FRP chequerred Plate of 6mm thick cover for cable duct complete all as specified & directed.
Supply and fixing on wall / pole / in panel single phase timer with necessary fittings, power contactor, Analog timer & MCB SP 20 A complete consisting the following enclosed in CRCA enclosure box of suitable size made out of 2mm thick MS sheet dully painted with 2 coats of synthetic enamel paint over a coat of red oxide and pre wired with suitable size copper conductor cable including locking arrangement all as specified and directed.
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron 32 x 6 mm strip as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 50mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed including removal of old earthing complete all as specified and directed.
Supply and Fix in repairs galvanised iron strip of size 32x6 mm burried in ground/ on wall as earth continuity conductor and all as specified and directed.
Dismantling & taking down existing down conductor, roof conductor, test point termination rods from the building complete all as specified and directed.
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron 32 x 6 mm strip as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 50mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed including taking down old earthing complete all as specified and directed.
Supply and fixing in repairs GI strip of size 32x6mm complete all as specified and directed.
All as per item No. 138 above but aluminium strip of size 25x3mm complete all as specified and directed.
S&F in repairs test point consisting of terminal box, drilled and screwed with 22 swg GI cover including 2 Nos 12mm dia 25mm long hexagonal head screws jointing GI and aluminium strips with bolts, nuts and washers on and including jointing plate made of gun metal or phosphor bronze of size 90x32x8mm complete enclosure/terminal block assy grouted in wall at 600 mm height from the length protection level by means of two nos 75x75x25mm MS plate with 6mm dia anchored bolts embedded in wall including nuts and washers all as specified and directed.
Supply and fix single pointed air termination aluminium rod 12mm dia 300mm long and including 40mm dia GI Medium grade support pipe 600mm long, 25x6mm MS flat iron clamps, bolts/nuts and washers etc lower end of pipe fitted in a 40mm dia GI socket screwed and welded on and including MS base plate of size 300x300x6mm thick grouted on top surface of the wall with 4 Nos 12mm dia regged MS bolts/nuts washer etc on GI pipe secured firmly laterally on the wall surface in a vertical manner by means of rugged bolts grouted on the walls including nuts and washers etc upper end of pipe duly plugged lower end of Air termination rod duly jointed/welded with down/ horizontal conductor complete all as specified and directed.
SHAH ENTERPRISES
saradhi construction combines
M/s ANUSHA ENTERPRISES
M/s K Venkateswara Rao
rahi consultant
M/S VASU ENGINEERS
Sai construction & services
PAVAN ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .