Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC RAJEEV NAGAR KUTIA GHUSIYANA KHARIKA TELIBAGH LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.8 L+₹80,500 (2.78%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹29.9 L+₹95,915 (3.31%)Rejected-Finance NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L3 | Rejected-Finance Being Higher Bidder | |
| 4 | L4₹30.7 L+₹1.7 L (5.78%)Rejected-Finance | L4 | Rejected-Finance Being Higher Bidder | |
| 5 | L5₹33.1 L+₹4.1 L (14.3%)Rejected-Finance | L5 | Rejected-Finance Being Higher Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Dec 2022, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT OF LT OH CONDUCTORS, UG CABLE, LT PANEL, TIMER AND OTHER ALLIED WORKS AT MD/OTM ACCN, GFA, NVL, OVL, 71 MOUNTAIN BDE, CARRIAPPA MARG AND OTHER ADJOINING AREA WEST OF MG ROAD UNDER GE E/M LUCKNOW
2022_MES_565893_1
GE/EM/LKO/EXT(ELECT)/T-57 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹80,000
Yes
15 Mar 2023
29 Nov 2022
28 Dec 2022
29 Nov 2022
26 Dec 2022
13 Dec 2022
Amount
Supply & in replacement, installing, testing and commissioning of factory made , tested , CPRI approved powder coated LT Panel board, cubical/enclouser should not less than (1400mmx1200mmx500mm) compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50x50x6mm thick MS angle iron frame work, the cubical have bottom channel of size 75x40mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :- (a) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release Ics= 100% Icu as per IEC - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release Ics= 100% Icu as per IEC - 03 Nos (ii) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release Ics= 100% Icu as per IEC - 02Nos.
All as per item No 1 above but comprising with following:- (a) Incoming :- (i) ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type high mechanicals & electrical operating life,front operated with thermal magnetic release for adjustable over current, short circuit and earth fault protection with in built tempraure protection. (ii) On load changeover switch 400 A, 4P, 50 Hz-01 Nos (iii) Digital VAF+PF meter with RS 485 CL1 -01No (iv) CTs ratio 800/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three (vi) Four Pole , Aluminium bus bar 1200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 315 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release Ics= 100% Icu as per IEC - 01 Nos (ii) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release Ics= 100% Icu as per IEC - 06 Nos
All as per item No 1 above but comprising with following:- (a) Incoming :- (i) MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release Ics= 100% Icu as per IEC - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 800/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 1000 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (vi) On load change over switch open execution type , 400 Amps , 4 pole , 415 volt , 50 Hz-01 No (b) Outgoing (i) MCCB 4 pole , 150 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release Ics= 100% Icu as per IEC - 03 Nos (ii) MCCB 4 pole , 125 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release Ics= 100% Icu as per IEC - 04 Nos
All as per item No 1 above but comprising with following:- (a) Size of panel (1200mmx1000mmx500mm) (b) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release Ics= 100% Icu as per IEC - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release Ics= 100% Icu as per IEC - 04 Nos
All as per item No 1 above but comprising with following:- (a) Incoming :- (b) Size of panel (1200mmx1000mmx500mm) (i) MCCB 4 pole , 315 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release Ics= 100% Icu as per IEC - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 125 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release Ics= 100% Icu as per IEC - 04 Nos
All as per item No 1 above but comprising with following:- (a) Size of panel (800mmx600mmx400mm) (b) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release Ics= 100% Icu as per IEC - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. ( c) Outgoing (i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release Ics= 100% Icu as per IEC - 01 Nos (ii) MCCB 4 pole , 125 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release Ics= 100% Icu as per IEC - 02 Nos
All as per item No 1 above but comprising with following:- (a) Size of panel (1200mmx1000mmx500mm) (b) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release Ics= 100% Icu as per IEC - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 1000/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (vi) On load change over switch 200 Amp.- 01 Nos. (c) Outgoing (i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 50 KA thermal magnetic release Ics= 100% Icu as per IEC - 04 Nos
M & L in replacement for Earthing complete with galvanised steel earth plate electrode 6mm thick of size 600x600 mm buried directly and vertically in ground with top edge of the plate not less than 2.25 mtr from GL, connected with galvanised iron strip 32x6mm all as shown in Plate No-3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx50mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 50 mm dia light grade GI tubing for protection of GI Strip 32x6mm, charcoal and salt in alternate 150mm thick layers around GI earth plate, including necessary returning filling in & removal all as specified or indicated in electric plate No 3 of SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion, complete all as specified and directed.
Supply & in replacement, laying jointing and testing LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core, laid in trench/laid under floor or fixed naked with wall/on wall/in ducts/in GI pipes etc. with and includings MS Clamps, nuts,bolts,washers complete all as specified and directed. Note- (Excation, earth works,and sand cushioning,protection bricks/tiles/blocks and pipe shall be measured and paid seprately under approlriate items)
All as per item No 9 above but size 240 sq mm 3.5 core
All as per item No 9 above but size 35 sq mm 3.5 core
All as per item No 9 above but size 120 sq mm 3.5 core
All as per item No 9 above but size 95 sq mm 3.5 core
All as per item No 9 above but size 70 sq mm 3.5 core
All as per item No 9 above but size 50 sq mm 3.5 core
All as per item No 9 above but size 16 sq mm 4 core
All as per item No 9 above but size 10 sq mm 2 core
All as per item No 9 above but size 6 sq mm 2 core
Excavation in trenches in soft/Loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick fly ash bricks as per IS 12894 -2002 laying in trenches perpendicular to axis of the cable complete all as specified and directed.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5 core 25 to 50 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5 core 70 to 95 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5 core 120 to 150 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 185 to 240 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
Supply and fix 4 pole MCCB 63 Amp, 50 Hz,415 V with repturing capacity 25 KA thermal magnetic release Ics= 100% Icu as per IEC, complete all as specified and directed.
Supply and fix 4 pole MCCB 100 Amp, 50 Hz,415 V with repturing capacity 25 KA thermal magnetic release Ics= 100% Icu as per IEC, complete all as specified and directed.
Supply and fix 4 pole MCCB 125 Amp, 50 Hz,415 V with repturing capacity 25 KA thermal magnetic release Ics= 100% Icu as per IEC, complete all as specified and directed.
Supply and fix 4 pole MCCB 160 Amp, 50 Hz,415 V with repturing capacity 25 KA thermal magnetic release Ics= 100% Icu as per IEC, complete all as specified and directed.
Supply and fix 4 pole MCCB 200 Amp, 50 Hz,415 V with repturing capacity 25 KA thermal magnetic release Ics= 100% Icu as per IEC, complete all as specified and directed.
Supply and fix 4 pole MCCB 250 Amp, 50 Hz,415 V with repturing capacity 25 KA thermal magnetic release Ics= 100% Icu as per IEC, complete all as specified and directed.
Supply and fix 4 pole MCCB 315 Amp, 50 Hz,415 V with repturing capacity 36 KA thermal magnetic release Ics= 100% Icu as per IEC, complete all as specified and directed.
Supply and fix 4 pole MCCB 400 Amp, 50 Hz,415 V with repturing capacity 36 KA thermal magnetic release Ics= 100% Icu as per IEC, complete all as specified and directed.
Supply and fix 4 pole MCCB 630 Amp, 50 Hz,415 V with repturing capacity 35 KA thermal magnetic release Ics= 100% Icu as per IEC, complete all as specified and directed.
Supply and fix 4 pole Isolator 63 Amp, 50 Hz,415 V with repturing capacity 16 KA, complete all as specified and directed.
Supply and fix 4 pole MCCB 100 Amp, 50 Hz,415 V with repturing capacity 16 KA, complete all as specified and directed.
Supply and fix 4 pole MCCB 125 Amp, 50 Hz,415 V with repturing capacity 16 KA, complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 40 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 50 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 80 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 100 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Boring/drilling (Horizontly) manually/mechanically under existing road max 10 M in depth) suitable for passing GI Tubing 40 to 100 mm bore complete all as specified and directed.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
M/s A.K Construction
NEXT POWER ENTERPRISES
M/s ARPIT ENTERPRISES
MTR GROUP & COMPANY
M/S S.B. Singh and Sons
Eco Creations
Prime power system
Unnati Engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .