Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAdmitted-Finance 100 33 1 R G S ROAD USHAGRAM SALANPUR 713303 WEST BENGAL INDIA | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | 713303 | ₹13.1 L | L1 | Admitted-Finance |
| 2 | L2₹16.2 LAdmitted-Finance 0 SHANKERPURI COLONY SAHARANPUR BEHAT ROAD NEAR DEHAT KOTWALI SAHARANPUR UTTAR PRADESH 247001 UDYAM UP 64 0001066 09DFQPR2451E1Z4 B R | SAHARANPUR | UTTAR PRADESH | 247001 | ₹16.2 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | ELECTRO TRADING CO. L2 | ELECTRO POWER INDUSTRIES L1 |
|---|---|---|---|---|---|
| 1.01 | Dismantling & Shifting of existing Transformer of capacity 10MVA, 33KV/6.6KV with all accessories | 1 | WORK | 15,000 ₹15,000 | 10,000 ₹10,000 |
| 1.02 | Placement, Installation, testing & Commissioning of 10MVA, 33KV/6.6KV Power Transformer after assembled of all cooling fins, Radiator tank, interconnection of all control Cables such as WTI & OTI protection and alarm, Buchholz Relay protection & Alarm oil level protection etc | 1 | WORK | 3,00,000 ₹3 L | 2,50,000 ₹2.5 L |
| 1.03 | Supply of 2” dia. Chemical earth electrode | 8 | NO | 60,000 ₹4.8 L | 50,000 ₹4 L |
| 1.04 | Supply of 8 polybags(25kgs in a polybag) of backfill chemicals compound(bentonite and marconite powder) 25 Kg. per electrode | 1 | WORK | 30,000 ₹30,000 | 20,000 ₹20,000 |
| 1.05 | Commissioning and testing of the chemical earth pits. | 1 | WORK | 30,000 ₹30,000 | 20,000 ₹20,000 |
| 1.06 | Supply of galvanized G.I. Earth Strip | 380 | KG | 150 ₹57,000 | 100 ₹38,000 |
| 1.07 | fabrication & laying of Hot deep galvanized G.I. Earth Strip for earthing of Transformer body as well as neutral of the Transformer. | 1 | WORK | 6,500 ₹6,500 | 5,700 ₹5,700 |
| 1.08 | 7 core x 2.5 sq.mm from Marceline box to C.R. Panel – 80 m | 1 | WORK | 60,000 ₹60,000 | 50,000 ₹50,000 |
| 1.09 | 4 core x 2.5 sq.mm from Marceline box to C.R. Panel – 60 m | 1 | WORK | 50,000 ₹50,000 | 34,500 ₹34,500 |
| 1.10 | 7 core x 2.5 sq.mm from outdoor 33KV CT to C.R. Panel – 140 m | 1 | WORK | 80,000 ₹80,000 | 70,000 ₹70,000 |
Tender Value
₹15.7 L
EMD Value
₹19,600
Closing Date
21 Nov 2025, 11:00 amClosed
Area Engineer EnM, Jhanjra ARea
Office of the General Manager, Jhanjra Area, ECL, 713385
Installation and other associated works for Newly procured Powerware make 10 MVA, 33/6.6 kV Oil cooled Transformer Sl no. 25010050 at main substation MIC, JPC
2025_ECL_346895_1
ECL/GM/JNR/EnM/A2/25-26/84 dated 04.11.2025
Open Tender
Miscellaneous Works
30 days
Jhanjra Underground
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,600
19 Dec 2025
10 Nov 2025
22 Nov 2025
10 Nov 2025
21 Nov 2025
11 Nov 2025
10 Nov 2025 - 17 Nov 2025
Amount
Dismantling & Shifting of existing Transformer of capacity 10MVA, 33KV/6.6KV with all accessories
Placement, Installation, testing & Commissioning of 10MVA, 33KV/6.6KV Power Transformer after assembled of all cooling fins, Radiator tank, interconnection of all control Cables such as WTI & OTI protection and alarm, Buchholz Relay protection & Alarm oil level protection etc
Supply of 2” dia. Chemical earth electrode
Supply of 8 polybags(25kgs in a polybag) of backfill chemicals compound(bentonite and marconite powder) 25 Kg. per electrode
Commissioning and testing of the chemical earth pits.
Supply of galvanized G.I. Earth Strip
fabrication & laying of Hot deep galvanized G.I. Earth Strip for earthing of Transformer body as well as neutral of the Transformer.
7 core x 2.5 sq.mm from Marceline box to C.R. Panel – 80 m
4 core x 2.5 sq.mm from Marceline box to C.R. Panel – 60 m
7 core x 2.5 sq.mm from outdoor 33KV CT to C.R. Panel – 140 m
7 core x 2.5 sq.mm from 33kV/110V/1Tr to Marceline box – 140 m
Supplying & laying of 1.1KV grade Armoured copper control cable
Pre-commissioning testing job of 1 No. 10MVA 33KV/6.6KV oil cooled type outdoor transformer. (the following Tests are to be carried out) a) Insulation resistance test b) Measurement of voltage ratio c) Magnetic balance test d) Measurement of winding resistance e) High voltage pressure test. f) Vector group test. g) Di-electric strength test of transformer oil. h) No load & load test. i) Buchholz relay function test. j) WTI, OTI function test
Refitting of connectors, IPS tube Secondary side cable for input 3 phase 33KV Supply to primary bushing and to receive 6.6KV Power from secondary side bushing.
De-hydration & Filtration of Transformer Oil to improve the di-electric strength of oil up to required value
Transportation of tools, tackles & transformer oil filter machine, all testing apparatus, from our WORKshop to your site vice versa
Total impact of GST for the purpose of CTC
ELECTRO TRADING CO. (BID ID -1197170)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.73 MB
Tendernotice_2.pdf
PDF • 1.20 MB
BOQ_359589.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid