Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.7 L+₹22,380 (1.00%)Rejected-Finance | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹26.7 L+₹4.3 L (19.0%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L3 | Rejected-Finance Other than lowest. |
Tender Value
₹25.5 L
EMD Value
₹51,000
Closing Date
11 Jan 2023, 6:00 pmClosed
GE AF ADampur
Garrison Engineer Military Engineer Services AF Stn Adampur 144103
REPAIR / REPLACEMENT OF ELECTRIC WIRING, LIGHT FITTINGS AND ELECTRIC FANS IN CAMP AREA AT AF STN ADAMPUR
2022_MES_569150_1
GE/AF/ADM-42/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Under GE AF Adampur
Refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE AF Adampur
₹51,000
Yes
28 Jan 2023
14 Dec 2022
12 Jan 2023
14 Dec 2022
11 Jan 2023
29 Dec 2022
15 Dec 2022 - 28 Dec 2022
Amount
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One light point controlled by two way switch or one fan point controlled by two switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC heavy duty concealed conduit all as specified.
One socket outlet, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet, 6/16 Amp, independent, with 4 Sq. mm (nominal area) cable & 4 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with base frame & cover plate suitable for fixing modular switch/sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One light point controlled by two way switch or one fan point controlled by two switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC heavy duty concealed conduit all as specified.
One socket outlet, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet, 6/16 Amp, independent, with 4 Sq. mm (nominal area) cable & 4 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
NOTES APPLICABLE FOR SERIAL ITEM NO. 1& 2: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
Switch piano flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole two way, 6 Amp complete all as specified.
Switch piano, bell/buzzer push, flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole one way, 16 Amp complete all as specified.
Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified.
Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
Lamp (angle) holder, insulated body, cord grip pattern, complete, all as specified.
Electric buzzer AC 230 volt, single pole, Ding Dong type complete, all as specified.
Fan regulator (electronic) suitable for 48”/56” sweep fan, step type, single phase, IN REPLACEMENT complete all as specified.
Switch modular type single pole one way, 6 Amp, complete all as specified.
Switch modular type single pole two way, 6 Amp, complete all as specified.
Bell push switch modular type single pole one way, 6 Amp, complete all as specified.
Switch modular type single pole one way, 16 Amp,complete all as specified.
Socket outlet modular type multipurpose having provision for 2&3 pin, 6 Amp, complete all as specified.
Socket outlet modular type multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, complete all as specified.
Fan regulator modular type (electronic) suitable for 48”/56” sweep fan, step type, two module, IN REPLACEMENT complete all as specified.
MAKE FOR SERIAL ITEM 13 TO 19: HAVELLS, LEGRAND or equivalent compatible make mentioned in Appendix 'B'.
Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
2 runs of 2.5 Sq. mm main cable + 1 run of 2.5 Sq. mm earth cable
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
Rigid non metallic, PVC concealed conduit, 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: -
SPN, 2 way with 200 Amp rated bus bar, 240 V, single door type
SPN, 4 way with 200 Amp rated bus bar, 240 V, double door type.
SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type.
SPN, 12 way with 200 Amp rated bus bar, 240 V, double door type.
TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type.
TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type having housing and including MCCB 4 pole 63 Amp, 16kA.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, IN REPLACEMENT complete all as specified.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp, IN REPLACEMENT complete all as specified.
MCB suitable for 415 volt AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 63 Amp, IN REPLACEMENT complete all as specified.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, IN REPLACEMENT complete all as specified.
Blanking plate to cover unused space in DB's complete all as specified..
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead including test point complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 3.3.3.1 of contract, IN REPAIR. NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made precast PCC pit with cover shall be fixed at least 500 mm away from earth pit.
Surface mounted envirnment friendly decorative ultra slim round profile LED 10 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. ENDURALINEARNEOBS10WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted envirnment friendly decorative ultra slim round profile LED 22 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. ENDURALINEARNEOBS22WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Recess mounted bottom opening LED 36W cool day light luminaire (2x2) CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. DROPDOWNFLAT2X2PLR36WLED857 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Recess mounted round shape bottom opening LED 10W cool day light luminaire CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. EDGEPRONEORDDLR12WLED865S or equivalent in makes mentioned in Appendix 'B' here-in-after.
Recess mounted round shape bottom opening LED 12W cool day light luminaire CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. EDGEPRONEORDDLR10WLED840S or equivalent in makes mentioned in Appendix 'B' here-in-after.
Collecton of items like ceiling fans, exhaust fans, wall mounted fans, cabin/table fans, flame proof ceiling fans from EM store yard for repair, transporting to workshop, opening and reassembling after including necessary cleaning greasing oiling etc, testing and depositing back to EM store yard of GE (AF) Adampur including necessary loading unloading and transporting etc. complete. NOTE: Supply only spares & rewinding of fan(s) shall be measured & paid for separately under respective items of BoQ.
Rewinding fan of any description with super enamelled copper winding wire of size, gauge & weight as per original specifications providing insulating material and varnishing with synthetic varnish, oiling, greasing and replacement of bearing, condenser of suitable rating to the entire satisfaction of Engineer-in-Charge including taking out burnt winding wire after opening the ceiling fan of size: -
Ceiling fan 1200 mm sweep
Ceiling fan 1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Wall mounted fan 650 mm sweep
Cabin/table fan 450 mm sweep
NOTE: Collecton of fan items from EM store yard, transporting to workshop and back including loading unloading shall be measured & paid for separately under respective items of BoQ.
PVC flexible Copper wire size 23/.0076 twin core, required length as directed, complete all as specified.
Weather proof flat twin core, cable of size 10 sq.mm with multi stranded aluminium conductor alongwith GI wire 4 sq.mm and spacer / insulator complete all as specified.
Electric meter box, out door type, made out of MS CRCA sheet not less than 2 mm thick of size 650x900x250 mm with cable gally at centre and six compartments (for fixing electric meters) each have separate hinged door including provision of glass of size 90x90mm for taking reading, weather/ vermen proof IP-46 protection including provision of high quality rubber bedding on panel door, cable entry arrangements at bottom, all surfaces duly powder coated of shade approved by Eng-In-Charge and fixed in position with cement mortor (1:4), IN REPLACEMENT complete. NOTE:- Cost of taking down of existing electric meter and re-fixing and re-connecting of the same is included in this item.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc. and making good surface as per existing, complete all as specified.
Taking down carefully light fitting of any description, complete all as specified.
Taking down carefully electric bell/buzzer of any description, complete all as specified.
M/S RAJESH CONSTRUCTION COMPANY
Northern cable fault locatoers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .