Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAdmitted-Finance FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | ₹35.0 L | L1 | Admitted-Finance |
| 2 | L2₹37.6 L+₹2.6 L (7.53%)Admitted-Finance | ₹37.6 L+₹2.6 L (7.53%) | L2 | Admitted-Finance |
| 3 | L3₹38.0 L+₹3.1 L (8.76%)Admitted-Finance | ₹38.0 L+₹3.1 L (8.76%) | L3 | Admitted-Finance |
| 4 | L4₹40.4 L+₹5.4 L (15.5%)Admitted-Finance | ₹40.4 L+₹5.4 L (15.5%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ESKIMO COOL WORLD L3 | BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS L4 | Maruti Abhiyantriki L2 | Chaulya Enterprises L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M & L for attending emergant complaints by experienced refregeration machanic i.e. pertaining to Centre AC Plant / Packages Type AC plant/ VRF / Type AC plant of any Capacity including carry out minor repairs and identification of fault etc as required to system in order/functional complete all as specified and direted by Engr-in-Charge. Note: - Major Spare parts will measured and paid seperately under relavent item, complaints as supply and fixing should be attended within 24 Hrs ,complete all as specified and directed by Engr-in-charge. | 200 | Each Job | 800 ₹1,60,000 | 1,200 ₹2,40,000 | 400 ₹80,000 Lowest | 700 ₹1,40,000 |
| 2.00 | M&L for replacement of unserviceable fan blade of outdoor condenser unit of air cooled package/ central type AC plant (5 to 7.5TR) as per existing make, model and type,complete all as specified and directed by Engr-in-charge. | 2 | Each Job | 3,000 ₹6,000 | 3,000 ₹6,000 | 600 ₹1,200 | 500 ₹1,000 Lowest |
| 3.00 | S&F for in replacement of existing unsv VLRP controller of chiller unit 15 to 36 TR cap testing, calibrating the functions with plant after replacement complete all as specified and directed by Engr-in-charge. | 4 | Each Job | 22,500 ₹90,000 | 35,000 ₹1,40,000 | 19,000 ₹76,000 | 11,500 ₹46,000 Lowest |
| 4.00 | M&L for servicing of pan type humidifier floor mounted/ installed at duct of capacity 6 /12 kW including cleaning of tank, checking of all inlet & outlet connection, checking and repair of all electrical control connections and making the pan type humidifier functional including replacement of heating elements of existing make & model, replacment of minor parts complete all as specified and directed by Engr-in-charge. | 8 | Each | 950 ₹7,600 | 2,500 ₹20,000 | 500 ₹4,000 Lowest | 500 ₹4,000 Lowest |
| 5.00 | M&L for replacement of HP/LP cut out suitable for compressor (5 to 18 TR) of package/central type AC plant including cutting, brazing and leakage testing complete as required at site and testing after replacement complete all as specified and directed by Engr-in-charge | 6 | Each | 1,000 ₹6,000 | 1,000 ₹6,000 | 1,100 ₹6,600 | 900 ₹5,400 Lowest |
| 6.00 | Supply & fixing PVC fills of cooling tower 5 TR to 200 TR as per OEM standard fixing secquance including cutting & filling the gaps so that the water of cooling tower spread equally includng refixing motor, pipe, sprinkler complete all as specified and directed by Engr-in-charge. | 10 | Each Job | 14,000 ₹1,40,000 | 14,000 ₹1,40,000 | 8,000 ₹80,000 | 4,500 ₹45,000 Lowest |
| 7.00 | M&L for replacement of defective temp sensor of chiller line as per existing make & model ,complete all as specified & directed by Engr-in-Charge. | 20 | Each | 850 ₹17,000 | 1,050 ₹21,000 | 400 ₹8,000 Lowest | 500 ₹10,000 |
| 8.00 | M&L for replacment of defective temperature controller with sensor including making proper wiring & connections complete all as specified suitable for existing & directed by Engr -in-Charge. | 4 | Each | 1,500 ₹6,000 | 1,500 ₹6,000 | 1,050 ₹4,200 | 1,000 ₹4,000 Lowest |
| 9.00 | M&L for replacmnet of defective humidity controller with sensor including making proper wiring & connections ,complete all as specified & directed by Engr-in-Charge. | 4 | Each | 3,000 ₹12,000 Lowest | 3,000 ₹12,000 Lowest | 3,600 ₹14,400 | 3,900 ₹15,600 |
| 10.00 | M&L for replacment of unsv flow switch of chiller & condensor line 63 to 200mm dia line , including making all control conections suitable for existing ,complete all as specified & directed by Engr-in-Charge. | 3 | Each | 1,500 ₹4,500 Lowest | 1,500 ₹4,500 Lowest | 3,200 ₹9,600 | 2,600 ₹7,800 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
17 Aug 2026, 6:00 pmClosed
Kiran Gajrani, IDSE
Commander Works Engineers (AF), Khese Park, Lohegaon, Pune-411032
MAINTENANCE REPAIR AND REPLACEMENT OF UNSERVICEABLE ITEMS OF AIR CONDITION PLANTS OF STORAGE ACCN INCLUDING ELECTRICAL PANEL DUCTING AND MISC ITEMS OF AC PLANTS AT 2 WING AF STN PUNE UNDER GE AF LOHEGAON
2026_MES_779680_1
83022/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF Lohegaon
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF Lohegaon
₹84,000
Yes
27 Aug 2026
20 Jul 2026
24 Aug 2026
20 Jul 2026
17 Aug 2026
3 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for attending emergant complaints by experienced refregeration machanic i.e. pertaining to Centre AC Plant / Packages Type AC plant/ VRF / Type AC plant of any Capacity including carry out minor repairs and identification of fault etc as required to system in order/functional complete all as specified and direted by Engr-in-Charge. Note: - Major Spare parts will measured and paid seperately under relavent item, complaints as supply and fixing should be attended within 24 Hrs ,complete all as specified and directed by Engr-in-charge. | 200 | Each Job | - | - |
| 2 | M&L for replacement of unserviceable fan blade of outdoor condenser unit of air cooled package/ central type AC plant (5 to 7.5TR) as per existing make, model and type,complete all as specified and directed by Engr-in-charge. | 2 | Each Job | - | - |
| 3 | S&F for in replacement of existing unsv VLRP controller of chiller unit 15 to 36 TR cap testing, calibrating the functions with plant after replacement complete all as specified and directed by Engr-in-charge. | 4 | Each Job | - | - |
| 4 | M&L for servicing of pan type humidifier floor mounted/ installed at duct of capacity 6 /12 kW including cleaning of tank, checking of all inlet & outlet connection, checking and repair of all electrical control connections and making the pan type humidifier functional including replacement of heating elements of existing make & model, replacment of minor parts complete all as specified and directed by Engr-in-charge. | 8 | Each | - | - |
| 5 | M&L for replacement of HP/LP cut out suitable for compressor (5 to 18 TR) of package/central type AC plant including cutting, brazing and leakage testing complete as required at site and testing after replacement complete all as specified and directed by Engr-in-charge | 6 | Each | - | - |
| 6 | Supply & fixing PVC fills of cooling tower 5 TR to 200 TR as per OEM standard fixing secquance including cutting & filling the gaps so that the water of cooling tower spread equally includng refixing motor, pipe, sprinkler complete all as specified and directed by Engr-in-charge. | 10 | Each Job | - | - |
| 7 | M&L for replacement of defective temp sensor of chiller line as per existing make & model ,complete all as specified & directed by Engr-in-Charge. | 20 | Each | - | - |
| 8 | M&L for replacment of defective temperature controller with sensor including making proper wiring & connections complete all as specified suitable for existing & directed by Engr -in-Charge. | 4 | Each | - | - |
| 9 | M&L for replacmnet of defective humidity controller with sensor including making proper wiring & connections ,complete all as specified & directed by Engr-in-Charge. | 4 | Each | - | - |
| 10 | M&L for replacment of unsv flow switch of chiller & condensor line 63 to 200mm dia line , including making all control conections suitable for existing ,complete all as specified & directed by Engr-in-Charge. | 3 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
83022TD.pdf
Tender Documents • 0.74 MB
83022PS.pdf
Tender Documents • 0.65 MB
BOQ_873297.xls
BOQ • 1.25 MB
corri-1-83022RevPAGE.pdf
PDF • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .