Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
22 Jun 2026, 6:00 pm
CWE Karanja
CWE Karanja Naval Station Karanja Uran, Navi Mumbai - 400 704
PERIODICAL MAINTENANCE AND ESSENTIAL REPAIRS TO FIRE ALARM PANEL SMOKE DETECTOR MCP HOOTER AND OTHER CONNECTED ITEMS AT INS TUNIR SAILOR MD ACCN CHUKAR SQN AND COMMON AREA AT NAVAL STATION KARANJA
2026_MES_768959_1
84535-K/E8
Open Tender
Electrical and Maintenance Works
330 days
Naval Station Karanja
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW Karanja
₹98,000
1 Jun 2026
1 Jun 2026
24 Jun 2026
1 Jun 2026
22 Jun 2026
15 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and Labour for periodical maintenance of fire alarm system by attending fault, testing of system, periodical checking of system. chaking MCP,Hooter, smockdetector and connecting all items including testing on monthly basis in presence of users representative, etc including attending system fault on emergency, preventive maintenance by replacing minor spares parts as per reqiurment for smoothly function of fire alarm system installed at Armoury store room bldg-441 at INS Tunir complete as per existing conventional / addressable type make,type Zone & loop etc main control panel comprising of the following complete all as specified and as directed:- (a) 8 to 12 Zone main control panel with zone card battery charger and 230 V power unit. (b) Ionisation type smoke detector, heat detector, response indicator, manual call point and hooters etc.
(c) All cable connections from main control panel to items
(d) Lead acid battery any capacity
(e) Electric Hooter
NOTE:- (i) Cost of Minor spare parts replaced other than as given in BOQ hereinafter shall be deemed to be included in the quoted unit rate quoted by the contractor.
(ii) Testing kit (Solo Smoke and heat detector kit) will be provided by the contractor for testing of system and report will be submitted to the Engineer in charge. | 11 | Per month | - | - |
| 2 | All as per BoQ Serial Item No.1 above but for MP shop tunir near nbcd hard but for as per existing main control panel with electric siren etc. | 11 | Per month | - | - |
| 3 | All as per BoQ Serial Item No.1 above but for storage hanger 13 and 14 tunir Area main control panel with electric hooter etc. | 11 | Per month | - | - |
| 4 | All as per BoQ Serial Item No.1 above but for Maharana pratap TP 3 and 4 tunir Area main control panel with electric hooter etc. | 11 | Per month | - | - |
| 5 | All as per BoQ Serial Item No.1 above but for Fire HQ tunir Area main control panel with electric hooter etc. | 11 | Per month | - | - |
| 6 | All as per BoQ Serial Item No.1 above but for Admin block tunir Area main control panel with electric hooter etc. | 11 | Per month | - | - |
| 7 | All as per BoQ Serial Item No.1 above but for Maharana pratap TP 3 and 4 tunir Area main control panel with electric hooter etc. | 11 | Per month | - | - |
| 8 | All as per BoQ Serial Item No.1 above but for Maharana pratap TP 3 and 4 tunir Area main control panel with electric hooter etc. | 11 | Per month | - | - |
| 9 | Ditto- all as per serial item No 1.00 here-in-before but for Maurya Hanger for 15 Zone main control panel | 11 | Per month | - | - |
| 10 | Ditto- all as per serial item No 1.00 here-in-before but for Harshawardhan Hanger (MRF P-20) for 15 Zone main control panel | 11 | Per month | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
SOC.pdf
Additional Documents • 0.29 MB
Tenderpages.pdf
Tender Documents • 1.24 MB
BOQ_861142.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid