| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC | ₹35.7 L Quoted ₹36.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹37.4 LRejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹37.4 L | L2 | Rejected-Finance L2 |
| 3 | L3₹38.4 LRejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA | HARYANA | 133001 | ₹38.4 L | L3 | Rejected-Finance L3 |
| 4 | L4₹39.1 LRejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹39.1 L | L4 | Rejected-Finance L4 |
| 5 | L5₹39.7 LRejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | ₹39.7 L | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | Arun enterprises L1 | M/S Sonu Traders L4 | Jawandha Enterprises L6 | Esha Engineers L3 | HARISH SALES CORPORATION L5 | SUN MANN ENGINEERS L2 | bharat contrectors L7 | Truly Technos LLP L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling old feeder pillar boxes and LT pannels any size complete all as specified and as directed by Engineer-in-charge. | 8 | Each | 50.05 ₹400.40 | 1,000 ₹8,000 | 1,000 ₹8,000 | 500 ₹4,000 | 500 ₹4,000 | 100 ₹800 | 100 ₹800 | 3,000 ₹24,000 |
| 2.00 | Supplying, installing, testing and commissioning of 415 Volts 3 Phase 4 Wire LT panel , 3.15 mm thick factory fabricated and tested all as per existing IEC 60439 Part 1, floor mounted, IP 55 grade, sheet Outdoor double door Partially Type Tested Assembly Type (PTTA) LT cubical panel made out of CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with TPN PVC sleeved aluminium bus bar of size 250 Amps incld. angle iron base frame of suitable size. Including Panel mounted/grouted on 150 mm thick PCC (1:4:8) type D2 1 Mtr above ground level and with 500 mm offsets on all 04 sides of the panel complete and including spiral HDPE pipes for all cables under the PCC of panel inclusive of following in accessories fitted in the panel complete all as specified and directed :-
(A). INCOMING: - (i) MCCB 160 Amps ,415 V 3 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable , Microprocessor release type including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 01 Nos
(B).OUTGOING: -
(i) MCCB 125 Amps ,415 V 3 pole 16 KA 50 Hz with Ics =100% Icu & spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 01 Nos
(ii) MCCB 100 Amps ,415 V 3 pole 16 KA 50 Hz with Ics =100% Icu & including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 01 Nos
(iii) MCB TPN 32 Amp - 01 No.
(iv) Spare cubicles for expansion as per MCCB 4P - 01 Nos.
(v) LED indicators - R/Y/B 240 V AC - 03 Sets of 03 Nos.( for incoming & 2 outgoings)
(vi) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as and including suitable size CTs (set of 3) - 01 No. (for Incoming feeder)
(vii) MCB SP 'C' series 10kA 6-32 Amps as protection for LED lamps and multifunction meter - 2 Nos.
(viii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. | 1 | Each Job | 1,50,004 ₹1.5 L | 90,000 ₹90,000 | 1,15,000 ₹1.1 L | 1,05,000 ₹1.1 L | 80,000 ₹80,000 | 74,420 ₹74,420 | 2,50,000 ₹2.5 L | 96,026 ₹96,026 |
| 3.00 | Supplying, installing, testing and commissioning of 415 Volts 3 Phase 4 Wire LT panel , 3.15 mm thick factory fabricated and tested all as per existing IEC 60439 Part 1, floor mounted, IP 55 grade, sheet Outdoor double door Partially Type Tested Assembly Type (PTTA) LT cubical panel made out of CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with TPN PVC sleeved aluminium bus bar of size 250 Amps incld. angle iron base frame of suitable size. Including Panel mounted/grouted on 150 mm thick PCC (1:4:8) type D2 1 Mtr above ground level and with 500 mm offsets on all 04 sides of the panel complete and including spiral HDPE pipes for all cables under the PCC of panel inclusive of following in accessories fitted in the panel complete all as specified and directed :-
A.INCOMING:- (i) MCCB 125 Amps ,415 V 3 pole 16 KA 50 Hz with Ics =100% Icu & spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 01 Nos
B.OUTGOING :-
(i) MCCB 100 Amps ,415 V 3 pole 16 KA 50 Hz with Ics =100% Icu & including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 01 Nos
(ii) MCB SPN 32 Amp - 04 No.
(iii) Spare cubicles for expansion as per MCCB 4P - 01 Nos.
(iii) LED indicators - R/Y/B 240 V AC - 02 Sets of 03 Nos. For incoming & outgoing
(iv) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)
(v) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps and multifunction meter - 2 Nos.
(vi) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. | 1 | Each Job | 1,25,002 ₹1.3 L | 50,000 ₹50,000 | 85,000 ₹85,000 | 65,000 ₹65,000 | 70,000 ₹70,000 | 58,000 ₹58,000 | 2,50,000 ₹2.5 L | 71,740 ₹71,740 |
| 4.00 | Supplying, installing, testing and commissioning of 415 Volts 3 Phase 4 Wire LT panel , 3.15 mm thick factory fabricated and tested all as per existing IEC 60439 Part 1, floor mounted, IP 55 grade, sheet Outdoor double door Partially Type Tested Assembly Type (PTTA) LT cubical panel made out of CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with TPN PVC sleeved aluminium bus bar of size 250 Amps incld. angle iron base frame of suitable size. Including Panel mounted/grouted on 150 mm thick PCC (1:4:8) type D2 1 Mtr above ground level and with 500 mm offsets on all 04 sides of the panel complete and including spiral HDPE pipes for all cables under the PCC of panel inclusive of following in accessories fitted in the panel complete all as specified and directed :-
(A).INCOMING :- (i) MCCB 100 Amps ,415 V 3 pole 16 KA 50 Hz with Ics =100% Icu & including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 01 Nos
(B). OUTGOING :-
(i) MCCB 63 amp 16 kA, 415V 3 pole with Ics =100% Icu & including spreader terminals - set of 03 and direct rotary handle - 01 No,all as per OEM specifications - 01 No.
(ii) MCB SPN 32 Amp - 04 No.
(iii) Spare cubicles for expansion as per MCCB 4P - 01 Nos.
(iv) LED indicators - R/Y/B 240 V AC - 02 Sets of 03 Nos. per incoming & outgoing
(v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, including CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feed
(vi) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps and multifunction meter - 2 Nos.
(vii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. | 2 | Each Job | 90,001 ₹1.8 L | 45,000 ₹90,000 | 84,000 ₹1.7 L | 70,000 ₹1.4 L | 70,000 ₹1.4 L | 58,000 ₹1.2 L | 2,50,000 ₹5 L | 1,32,482 ₹2.6 L |
| 5.00 | Supplying, installing, testing and commissioning of 415 Volts 3 Phase 4 Wire LT panel , 3.15 mm thick factory fabricated and tested all as per existing IEC 60439 Part 1, floor mounted, IP 55 grade, sheet Outdoor double door Partially Type Tested Assembly Type (PTTA) LT cubical panel made out of CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with TPN PVC sleeved aluminium bus bar of size 250 Amps incld. angle iron base frame of suitable size. Including Panel mounted/grouted on 150 mm thick PCC (1:4:8) type D2 1 Mtr above ground level and with 500 mm offsets on all 04 sides of the panel complete and including spiral HDPE pipes for all cables under the PCC of panel inclusive of following in accessories fitted in the panel complete all as specified and directed :-
(A). INCOMING :- (i) MCCB 63 amp 16 kA, 415V 3 pole with Ics =100% Icu & including spreader terminals - set of 03 and direct rotary handle - 01 No, all as per OEM specifications - 01 No.
(B). OUTGOING :-
(i) MCB SPN 32 Amp - 03 No
(iii) LED indicators - R/Y/B 240 V AC - 03 Sets of 03 Nos. per incoming & outgoing
(iv) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)
(v) MCB SP 'C' series 10kA 6-32 Amps as protection for LED lamps and multifunction meter - 2 Nos
(vi) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. | 3 | Each | 60,004 ₹1.8 L | 25,000 ₹75,000 | 65,000 ₹1.9 L | 43,000 ₹1.3 L | 60,000 ₹1.8 L | 47,900 ₹1.4 L | 2,50,000 ₹7.5 L | 1,48,305 ₹4.4 L |
| 6.00 | Supplying, installing, testing and commissioning of 415 Volts 3 Phase 4 Wire LT panel , 3.15 mm thick factory fabricated and tested all as per existing IEC 60439 Part 1, floor mounted, IP 55 grade, sheet Outdoor double door Partially Type Tested Assembly Type (PTTA) LT cubical panel made out of CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with TPN PVC sleeved aluminium bus bar of size 250 Amps incld. angle iron base frame of suitable size. Including Panel mounted/grouted on 150 mm thick PCC (1:4:8) type D2 1 Mtr above ground level and with 500 mm offsets on all 04 sides of the panel complete and including spiral HDPE pipes for all cables under the PCC of panel inclusive of following in accessories fitted in the panel complete all as specified and directed :-
(A). INCOMING :- (i) MCCB 63 amp 16 kA, 415V 3 pole with Ics =100% Icu & including spreader terminals - set of 03 and direct rotary handle - 01 No,, all as per OEM specifications - 01 No.
(B).OUTGOING :-
(i) MCB SPN 32 Amp - 05 No.
(ii) Spare cubicles for expansion as per MCCB 4P Amps - 01 Nos.
(iii) LED indicators - R/Y/B 240 V AC - 03 Sets of 03 Nos. per incoming & outgoing
(iv) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)
(v) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps and multifunction meter - 2 Nos.
(vi) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. | 1 | Each | 60,004 ₹60,004 | 25,000 ₹25,000 | 75,000 ₹75,000 | 65,000 ₹65,000 | 60,000 ₹60,000 | 54,000 ₹54,000 | 2,50,000 ₹2.5 L | 63,940 ₹63,940 |
| 7.00 | Material and labour for 40 mm bore galvanized steel tubing light garde (ISI marked) for protection of cable fixed to pole/walls or laid in floors, road and duct crossing with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and as directed | 50 | RM | 100 ₹5,000 | 300 ₹15,000 | 450 ₹22,500 | 250 ₹12,500 | 250 ₹12,500 | 260 ₹13,000 | 150 ₹7,500 | 468 ₹23,400 |
| 8.00 | Material and labour for 80 mm bore galvanized steel tubing light garde (ISI marked) for protection of cable fixed to pole/walls or laid in floors, road and duct crossing with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and as directed | 120 | RM | 200.08 ₹24,009.60 | 600 ₹72,000 | 650 ₹78,000 | 400 ₹48,000 | 400 ₹48,000 | 420 ₹50,400 | 300 ₹36,000 | 810 ₹97,200 |
| 9.00 | Dismantling concrete poles/ struts, any size complete all as specified and as directed | 40 | Each | 44.88 ₹1,795.20 | 600 ₹24,000 | 500 ₹20,000 | 500 ₹20,000 | 500 ₹20,000 | 100 ₹4,000 | 100 ₹4,000 | 500 ₹20,000 |
| 10.00 | Dismantling of cross arms of MS channel or angle etc complete setting aside for reuse within 50 m or remove from site complete all as specified and as directed. | 0.6 | Qtl | 307 ₹184.20 | 400 ₹240 | 1,500 ₹900 | 100 ₹60 | 500 ₹300 | 100 ₹60 | 1,000 ₹600 | 1,000 ₹600 |
Updated dates
Tender Value
₹65.1 L
EMD Value
₹1.2 L
Closing Date
24 Jan 2026, 6:00 pmClosed
HQ CWE PATIALA
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact 01712200082
SPECIAL REPAIR TO LT DISTRIBUTION NETWORK SYSYTEM FROM MAG-23 TO CLP-A AT DAPPAR UNDER AGE (I) DAPPAR
2025_MES_745442_1
CWE/PAT/T-74/2025-26
Open Tender
Civil Works
180 days
AGE I DAPPAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
₹1.2 L
24 Feb 2026
20 Dec 2025
26 Jan 2026
20 Dec 2025
24 Jan 2026
10 Jan 2026
20 Dec 2025 - 3 Jan 2026
Dismantling old feeder pillar boxes and LT pannels any size complete all as specified and as directed by Engineer-in-charge.
Supplying, installing, testing and commissioning of 415 Volts 3 Phase 4 Wire LT panel , 3.15 mm thick factory fabricated and tested all as per existing IEC 60439 Part 1, floor mounted, IP 55 grade, sheet Outdoor double door Partially Type Tested Assembly Type (PTTA) LT cubical panel made out of CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with TPN PVC sleeved aluminium bus bar of size 250 Amps incld. angle iron base frame of suitable size. Including Panel mounted/grouted on 150 mm thick PCC (1:4:8) type D2 1 Mtr above ground level and with 500 mm offsets on all 04 sides of the panel complete and including spiral HDPE pipes for all cables under the PCC of panel inclusive of following in accessories fitted in the panel complete all as specified and directed :- (A).INCOMING :- (i) MCCB 100 Amps ,415 V 3 pole 16 KA 50 Hz with Ics =100% Icu & including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 01 Nos (B). OUTGOING :- (i) MCCB 63 amp 16 kA, 415V 3 pole with Ics =100% Icu & including spreader terminals - set of 03 and direct rotary handle - 01 No,all as per OEM specifications - 01 No. (ii) MCB SPN 32 Amp - 04 No. (iii) Spare cubicles for expansion as per MCCB 4P - 01 Nos. (iv) LED indicators - R/Y/B 240 V AC - 02 Sets of 03 Nos. per incoming & outgoing (v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, including CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feed (vi) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps and multifunction meter - 2 Nos. (vii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
Material and labour for 80 mm bore galvanized steel tubing light garde (ISI marked) for protection of cable fixed to pole/walls or laid in floors, road and duct crossing with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and as directed
Dismantling of cross arms of MS channel or angle etc complete setting aside for reuse within 50 m or remove from site complete all as specified and as directed.
Dismantling insulators any type any size complete all as specified and as directed.
Dismantling of ACSR or AAC conductor any size and any type complete all as specified and as directed .
Taking down old unserviceable cables/ service cable of any size etc from poles/struts/walls/ buildings etc complete all as specified and as directed.
Supply,laying/fixing, jointing,testing and commissioning XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2 core laid in trenches/ducts/pipes/fixed on wall/pole etc complete all as specified and as directed.
Supply,laying/fixing, jointing,testing and commissioning XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm 3.5 core laid in trenches/ducts/pipes/fixed on wall/pole etc complete all as specified and as directed.
Supply,laying/fixing, jointing,testing and commissioning XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sqmm 3.5 core laid in trenches/ducts/pipes/fixed on wall/pole etc complete all as specified and as directed.
Excavation in trenches in soft/loose soil n exc 1.5m wide and not Exc1.5m deep and getting out including forming bottom surfaces to required level or slope for taking out old cables,brick/PCC tiles covers complete all specified and all as directed .
Material and labour filling, spreading dry sand in trenches in layers for cushioning to under ground cable for protection of cable, 8cm deep before laying and 15 cm after laying the cable and punned to provide required cover complete all as specified and as directed. Note :- For payment Punned depth shall only be measured.
Material and labour for LT cable route indicator/made of RCC M-20 grade with 4 x 6mm round bar with 3 rings of size 450x300x100 mm thick duly embossed of letter likt HT/LT cable including painting with tint as directed with proper finishing and smoothing the surface and embedding of cable rote indicators in foundation concrete PCC 1:2:4 type B-1 complete all as specified and as directed by Engneer-in-charge.
Removal of surplus excavated soil to a distance exc 50 m but not exc in 100 m and deposited where directed at a level n'exc 50 m above the starting point complete all as specified and as directed.
Returning filling in soft/ loose soil in trenches including spreading, leveling watering and well ramming in 25mm thick layer complete all as specified and as specified.
irected by Engineer-in-Charge
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
TENDER742526.pdf
Tender Documents • 1.55 MB
BOQ_834704.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid