Loading…
Loading…
Tender Value
₹10.9 Cr
EMD Value
₹11 L
Closing Date
18 Mar 2026, 3:00 pmClosed
MR Kamlesh Kumar Verma(DFLT)
NRDA, NAYA RAIPUR
“Design, Supply,and Installation, including Replacement of Existing HPSV Street Light with LED Street Light at Various Sectors of Nava Raipur Atal Nagar, Raipur (C.G.)”(1st Call)
186698
NIT No: 97/RF-HPSV-LED/EEE/CE/NRANVP/2025-26, Nava Raipur Atal Nagar Dist. Raipur Dated:25.02.2026
OPEN TENDER
WORKS
12 days
NRDA, NAYA RAIPUR
Required Past Technical Experience: AS PER DNIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
16 documents required · 16 mandatory
Nava Raipur Atal Nagar Vikas Pradhikaran (NRANVP)
WORKS
MR Kamlesh Kumar Verma(DFLT)
OPEN TENDER
PERCENTAGE
OPEN TO ALL
NRDA, NAYA RAIPUR
ENGINEERING
CHIEF ENGINEER OFFICE
90
12.00
No
0
186698
18 Mar, 2026 3:00:00 PM IST
19 Mar, 2026 4:00:00 PM IST
5 Mar, 2026 11:58:00 PM IST
NIT No: 97/RF-HPSV-LED/EEE/CE/NRANVP/2025-26, Nava Raipur Atal Nagar Dist. Raipur Dated:25.02.2026
“Design, Supply,and Installation, including Replacement of Existing HPSV Street Light with LED Street Light at Various Sectors of Nava Raipur Atal Nagar, Raipur (C.G.)”(1st Call)
1100000.00 INR
BANK GUARANTEE (OFFLINE) Demand Draft (OFFLINE) Fixed Deposit Receipt (OFFLINE)
108558629.00
2
19 Mar, 2026 3:00:00 PM IST
108558629
AS PER NIT
AS PER NIT
AS PER DNIT
11800.00 INR
12d 12h 54m
16 documents required · 16 mandatory
₹11,800
₹11 L
25 Feb 2026
25 Feb 2026
19 Mar 2026
5 Mar 2026
18 Mar 2026
5 Mar 2026
19 Mar 2026
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 63 mm outer dia and 50 mm inner dia
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification.. 90 mm outer dia and 75 mm inner dia
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification.. 200 mm outer dia and 170 mm inner dia
Supplying and laying following sizes one number FRLS PVC insulated , PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 9537 (2000, Part 5). 3.5 x 25 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated , PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 9537 (2000, Part 5). 3.5 x 50 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated , PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 9537 (2000, Part 5). 3.5 x 150 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated , PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 9537 (2000, Part 5). 3.5 x 240 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated , PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 9537 (2000, Part 5). 4 x 10 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated , PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 9537 (2000, Part 5). 4 x 16 sq. mm.
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3½ X 25 sq. mm (25 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3½ X 50 sq. mm (32 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3½ X 150 sq. mm (45 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3½ X 240 sq. mm (57 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 4 X 10 sq. mm (22 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 4 X 16 sq. mm (22 mm)
Supplying and making straight through joint with heat shrinkable joint kit including aluminium ferrules for following size of FRLS PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as per specification. 3½ X 25 sq. mm
Supplying and making straight through joint with heat shrinkable joint kit including aluminium ferrules for following size of FRLS PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as per specification. 3½ X 50 sq. mm
Supplying and making straight through joint with heat shrinkable joint kit including aluminium ferrules for following size of FRLS PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as per specification. 4 X 16 sq. mm
Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. 10 sq. mm
Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. 16 sq. mm
Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. 25 sq. mm
Supplying, Installation, testing and commissioning for the following (0-10v) 10 step dimmable driver based LED Street Light fixture with PLC reciever, IP66 protected Die-Cast Aluminum housing and Heat resistive Toughened Glass. LED shall having LM80 complied as per L70 standard LEDs minimum tested for 10,000 burning hours with 5700-6000K CCT with minimum life cycle 50000 hrs burning hours at 50”C. Luminaire shall have PLC reciever for communication through CCMS. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be operatable at voltage range of 120-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60V DC. Driver Power factor shall be 0.95 and above and THD shall be less than 10%. Nominal system efficacy ratio shall be ≥140 lumen/watt. Not more than 45 Watt
Supplying, Installation, testing and commissioning for the following (0-10v) 10 step dimmable driver based LED Street Light fixture with PLC reciever, IP66 protected Die-Cast Aluminum housing and Heat resistive Toughened Glass. LED shall having LM80 complied as per L70 standard LEDs minimum tested for 10,000 burning hours with 5700-6000K CCT with minimum life cycle 50000 hrs burning hours at 50”C. Luminaire shall have PLC reciever for communication through CCMS. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be operatable at voltage range of 120-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60V DC. Driver Power factor shall be 0.95 and above and THD shall be less than 10%. Not more than 90 Watt
Supplying, Installation, testing and commissioning for the following (0-10v) 10 step dimmable driver based LED Street Light fixture with PLC reciever, IP66 protected Die-Cast Aluminum housing and Heat resistive Toughened Glass. LED shall having LM80 complied as per L70 standard LEDs minimum tested for 10,000 burning hours with 5700-6000K CCT with minimum life cycle 50000 hrs burning hours at 50”C. Luminaire shall have PLC reciever for communication through CCMS. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be operatable at voltage range of 120-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60V DC. Driver Power factor shall be 0.95 and above and THD shall be less than 10%. Not more than 120 Watt
Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 10 KV surge protection on pole bracket, including connection, earthing etc complete as per specification and furnishing 5 Yrs Warranty certificate from manufacturer. P.F. should be greater than 0.9. Nominal system efficacy ratio ≥ 140 lumens /watt. 400 Watt
Supply, installation, testing and commissioning of GPRS/GSM based communication module for Street Light Automation System, complete in all respects as per approved drawings and technical specifications. The module shall be suitable for remote monitoring, control and data transmission of street lighting feeders and shall support SIM-based GSM/GPRS connectivity. The system shall have dual communication capability, including wireless (GSM/GPRS) and wired (Ethernet/Fiber) internet connectivity for reliable and uninterrupted operation. It shall enable real-time monitoring, remote switching control, energy data logging, fault detection and reporting through both mobile devices (Android/iOS) and desktop/web-based platforms via a dedicated portal. The module shall be compatible for integration with the Integrated Command and Control Centre (ICCC) and support standard communication protocols required for seamless integration. The module shall be properly housed inside the existing feeder pillar with suitable mounting arrangement, and all necessary power, control and communication wiring shall be carried out for complete and functional operation of the system. The scope shall include supply of power supply units, antennas, communication cables, glands, terminations, configuration, programming, testing and commissioning, ensuring full completeness and reliable performance of the street lighting automation network.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification.
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043-1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: With 3 metre long GI Pipes and 50 kg back filling compound.
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3). 6 metre high, dia 130mm at bottom and 90mm at top, base plate size 220x220x12mm, foundation bolts 600mm long
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 4mm thick anchor plate, 4 nos 24mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3). 9 metre high, dia 155mm at bottom and 90mm at top, base plate size 260x260x16mm, foundation bolts 750mm long
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 4mm thick anchor plate, 4 nos 24mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3). 10 metre high, dia 175mm at bottom and 90mm at top, base plate size 275x275x16mm, foundation bolts 750mm long
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification.
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification. Single Over Hang 1.50 metre Long
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification. Double Over Hang 1.50 metre Long
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification. Double Over Hang 1.50 metre Long
Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 6 metre high
Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 9 metre high
Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 10 metre high
Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification.
Providing and making suitable CC pole collar (muffing) in Cement Concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) of size 0.4 m dia and 0.4 m height from existing CC foundation.
Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, unarmoured, copper conductor control /power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 9537 (2000, Part 5). 4 x 1.5 sq. mm
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps
Supplying erection testing and commissioning of hot dipped galvanised (single dip, minimum 86 micron) 25 metre High mast pole on existing RCC foundation with all accessories and equipments, main detailed as below to withstand max wind pressure as per IS 875 Part-3: a) HM shaft made of approved no of sections (not more than 3) having suitable sectional lengths with slip joints between sections without any circumpherencial welding sheet thickness 3 mm top & 4 mm middle and bottom section, nominal dia 460mm on bottom and 150 mm on top, base plate 25mm thick 670mm dia, PCD of foundation bolts 590mm. b) Double drum winch with Integral single phase power tool (electrical) for lowering & raising of lantern carriage on high mast with separate handle for manual operation of winch with a torque limiting device for safe locking of carriage. c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box. d) Top pulley assemble with weather proof cover. e) 2 Nos suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & rising of lantern carriage. f) Suitable size and length multicore flexible copper power trailing cable (minimum 3 core 4 sqmm) g) Hinged service door in base section h) Base plate earthing terminal. i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. j) Lightning conductor finial made of 25mm dia 300 mm long G.I.tube having single prong. k) Anchor plate, tem-plates, GI foundation bolts min 12 Nos of 30 mm dia 850 mm long (EN 8 Grade) along with nuts washers etc. (RCC fooundation and luminaries will be paid separately)
Supply and installation of pole cover and junction box assembly for existing street light pole. The pole cover shall be fabricated from heavy-duty GI sheet, hot-dip galvanized, weather-proof and suitable for outdoor use, with hinged arrangement and provision for anti-theft locking system (tamper-proof lock/bolt arrangement). The junction box shall be made of flame-retardant material with suitable terminals, neutral link and earth stud for loop-in/loop-out wiring. The assembly shall include a round protection clamp permanently fixed/welded to the pole structure to prevent detachment and ensure anti-theft protection
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.07 MB
1532727357942785363_185082_02 Affidavit p.pdf
NIT • 0.16 MB
2609246711831988313_185082_Guidelines_To_Bidders_EPS_v1.pdf
NIT • 0.52 MB
3645478550534049361_67966_03 NRANVP-GCC2011 - e Modified R3.pdf
NIT • 1.69 MB
8282150794799010266_186698_01 NRANVP F-1.pdf
NIT • 11.09 MB
1639107748561515681_186698_05 BOQ.xlsx
BOQ • 0.07 MB
Download all tender documents and submit your bid